Records from 1980 to 2020. Most recent: inspection, 6 November 2020.
Construction/Loadline › Hull › Weld
Issued 26 July 2007
No resolution recorded
Found vessel not conducting dry-dock repairs in accordance with ABS rules for steel repairs. Make proper repairs in accordance with ABS rules.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Weld
Issued 26 July 2007
No resolution recorded
Found vessel not conducting dry-dock repairs in accordance with NVIC 7-68 (Notes on Inspection and Repair of Steel Hulls). Make proper repairs in accordance with NVIC 7-68.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Weld
Issued 26 July 2007
No resolution recorded
Found vessel without proper dry-dock repair plan or weld procedures. Gage all wasted hull structures including hull, deck, bulkhead plating; frames, beams, shell structures and super structures. Review results and provide and comprehensive repair plan for all structures wasted beyond 20% of the vessels original scantlings.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Weld
Issued 26 July 2007
Resolved
Found repairs previously made during this dry-dock not in accordance with ABS rules/NVIC 7-68 rules. Prove existing new weld repairs meet noted standards utilizing approved NDT processes like UT.
Action required: 705 - Other - as specified
Resolved 9 December 2008
Resolution: Ultrasonic testing was conducted on more than 50% of welds on each insert. No deficiencies noted.
Engineering › Lubricating Oil Storage/Transfer System › Vent Pipe
Issued 18 July 2007
Resolved
Renew wasted L/O vent pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: L/O vent pipe renewed.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 18 July 2007
No resolution recorded
Make proper repairs to main engine lagging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Engineering › Steering Gear System › Bracket/Clamp
Issued 18 July 2007
Resolved
Replace wasted bolts and nuts on rudder packing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Bolts have been replaced.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 18 July 2007
No resolution recorded
Make proper repairs to all expansion tanks. All are leaking and missing sight glasses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 18 July 2007
No resolution recorded
Remove plywood space fwd of generator space. Space not approved by CG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 18 July 2007
No resolution recorded
Install means for shutting down propulsion engines at pilot station IAW 46CFR184.620.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2007 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 July 2007
No resolution recorded
Install metal fasteners for wire runs every 24 inches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Structures › Cofferdam
Issued 18 July 2007
Resolved
Crop and renew containment for port and starboard fuel stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Containmnet is removed vessels has opted to use 5 gallon buckets vice installed containment.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 July 2007
Resolved
Crop and renew wasted/holed piping at port and starboard fuel stations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Piping is renewed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 18 July 2007
Resolved
Crop and renew wasted/holed plating located at port and starboard exhaust housing. Holes are allowing rainwater to fill engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Exhaust housings are renewed.
Deck/Cargo › Towing › Chocks
Issued 18 July 2007
Resolved
Crop and renew port aft bit and stbd mid bit excessive wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Bits have been cropped and renewed.
Deck/Cargo › Towing › Brake
Issued 18 July 2007
No resolution recorded
Crop and wasted anchor mounts. Prove proper operation of anchor windlass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 18 July 2007
Resolved
Make proper repairs to cagro fuel control box and shoretie connection. Repairs to be completed by qualified marine eledtrician.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Fuel Control box and shortie have been over hauled.
Engineering › Bilge Water Management System › Pump
Issued 18 July 2007
No resolution recorded
Remove all oil and debris from all bilges. Prove proper operation of bilge pump and manifold system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Structures › Superstructure
Issued 18 July 2007
No resolution recorded
Crop and renew wasted awning brackets located on 01 deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Structures › Scuttle
Issued 18 July 2007
No resolution recorded
Make proper repairs to port engine room scuttle, fwd generator QAWTD and steering space QAWTD. Prove proper operation of all scuttles and QAWTD's throughout vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Communications › Radio Communications › EPIRB
Issued 18 July 2007
Resolved
Provide EPIRB with NOAA registration.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: EPIRB is now registered with NOAA.
Lifesaving › Inflatable Liferafts › Servicing
Issued 18 July 2007
No resolution recorded
Provide servicing report for (3) 25 man inflatable life rafts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 July 2007 — due date passed with no resolution recorded
Engineering › Steering Gear System › Rudder
Issued 18 July 2007
Resolved
Crop and renew wasted gussets for stbd rudder post.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Gussest have been renewed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 July 2007
No resolution recorded
Remove all unused marine batteries. Provide battery boxes.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 July 2007
No resolution recorded
Crop and renew all wasted piping located in engine space. Prove proper operation of all systems, bilge, ballast, fire and test generaotrs and main engine. Stbd main engine missing govenor linkage and has wasted saltwater piping. Port generator lexcessive leaking. All expanison tanks need to be replaced due to excessive leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 July 2007
No resolution recorded
Provide gauging report for stbd L/O tank due to excessive wastage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Electrical › Electric Generation Source (service) › Panelboard
Issued 18 July 2007
No resolution recorded
Replace broken gauges on main switchboard. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
Resolved
Complete overhead welds for insert located in engine space. Insert is above stbd main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 March 2008
Resolved 13 March 2008
Resolution: Welds are completed.
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
No resolution recorded
Make proper repair to hole located in steering space in hull above the waterline. Provide repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2007 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
No resolution recorded
Gauge all hull plating, framing and bulkheads from main deck and below throughout vessel on 12 inch centers. Provide report to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
No resolution recorded
Gauge main deck forward of aftermost part of house on twelve inch centers. Provide report to USCG.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007 — due date passed with no resolution recorded
Construction/Loadline › Hull › Hull Plating
Issued 18 July 2007
No resolution recorded
Any hull plating, renewed to make vessel watertight in advance of an approved repair plan is not approved and must be cropped and renewed and the work included on the pending repair plan subject to CG approval.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2007 — due date passed with no resolution recorded
Lifesaving › Inflatable Liferafts › Servicing
Issued 19 February 2007
No resolution recorded
Provide servicing report for (3) 25 man inflatable liferafts prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 20 February 2007 — due date passed with no resolution recorded
Fire Fighting › Fire Hoses › Condition
Issued 19 February 2007
No resolution recorded
Provide fire hoses prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Due 20 February 2007 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 19 February 2007
No resolution recorded
Prove proper operation of stbd main engine. Engine fails to engage shaft.
Condition: Improper/Lack of Maintenance
Due 20 February 2007 — due date passed with no resolution recorded
Documentation › Logs/Records › Logbook (official)
Issued 15 February 2006
Resolved
Provide log entries for firefighting drills and lifesaving equipment.
Condition: Unknown
Due 27 February 2006
Resolved 25 July 2006
Fire Fighting › Fire Pumps › Pressure
Issued 15 February 2006
Resolved
Prove proper operation of fire pumps, main engines and ship generators.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 15 February 2006
Resolved
Provide 46 CG adult life jackets IAW 46CFR180.75.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Lifesaving › Lifebuoys › Quantity
Issued 15 February 2006
Resolved
Provide (3) ring lifebuoys IAW 46CFR180.70.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Lifesaving › Hand Flares › Expired
Issued 15 February 2006
Resolved
Provide (1) oraange distress signal.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Communications › Radio Communications › EPIRB
Issued 15 February 2006
Resolved
Provide EPIRB IAW 46 CFR180.64.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Lifesaving › Inflatable Liferafts › Painter
Issued 15 February 2006
Resolved
Provide sea painters and float free link IAW 46CFR180.130.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 15 February 2006
Resolved
Provide embarkation ladder IAW 46CFR180.150(2)(b).
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Documentation › Certificates/Documents › International Load Line Certificate
Issued 15 February 2006
Resolved
Provide annual endorsement for load line cert.
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 15 February 2006
Resolved
Complete underway fire and manoverobard drills for CG.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 15 February 2006
Resolved
Provide (5) B-II fire extinguishers .
Condition: Unknown
Due 15 February 2006
Resolved 25 July 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 February 2006
Resolved
Batteries were not secured in boxes with proper covers.
Due 15 February 2006
Resolved 25 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 February 2006
Resolved
Needs to make repairs to main deck exhaust units (both Port and Starboard).
Due 15 February 2006
Resolved 25 July 2006
Engineering › Pressure Vessel › Foundation
Issued 15 February 2006
Resolved
Need to make pressure vessel ready for inspection.
Due 15 February 2006
Resolved 25 July 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 February 2006
Resolved
Remove all oil from aft steering and fuel tank passageways.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Fire Fighting › Fire Hoses › Number
Issued 15 February 2006
Resolved
Provide three (3) fire hoses (1.5 diameter).
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2006
No resolution recorded
Remove or properly repair dead end wires throughout the vessel.
Condition: Improper/Lack of Maintenance
Due 15 February 2006 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Valve, Control
Issued 15 February 2006
Resolved
Provide proper operation of emergency fuel shutoff valves.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 February 2006
Resolved
Provide valid Certificate of Inspection.
Due 15 February 2006
Resolved 25 July 2006
Documentation › Certificates/Documents › FCC SSL
Issued 15 February 2006
Resolved
Provide FCC Safety Certificate.
Due 15 February 2006
Resolved 25 July 2006
Documentation › Safety Management System › Designated Person(s) Documentation
Issued 15 February 2006
Resolved
Provide Red Cross/CPR cards for 50% of crew.
Due 15 February 2006
Resolved 25 July 2006
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 February 2006
Resolved
Provide material for DAPI audit.
Due 15 February 2006
Resolved 25 July 2006
Personnel › Manning/Qualifications › Qualified Individual (VRP)
Issued 15 February 2006
Resolved
Provide 1st Mate license IAW COI.
Due 15 February 2006
Resolved 25 July 2006
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 February 2006
Resolved
Provide US Coast Pilot, CG Light list, Tide tables and Current tables.
Due 15 February 2006
Resolved 25 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 February 2006
Resolved
Prove proper operation of stern light.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Communications › Audible Communications › SPD (Other)
Issued 15 February 2006
Resolved
Provide Public Address system IAW 46 CFR 184.610.
Due 15 February 2006
Resolved 25 July 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 February 2006
Resolved
Provide adequate First Aid kit IAW 46 CFR 184.710.
Due 15 February 2006
Resolved 25 July 2006
Construction/Loadline › Structures › Scuttle
Issued 15 February 2006
Resolved
Make proper repairs to combing for engine room space escape scuttle.
Condition: Improper/Lack of Maintenance
Due 15 February 2006
Resolved 25 July 2006
Fire Fighting › Fire Pumps › Pressure
Issued 15 February 2006
Resolved
Provide Discharge pressure gauge for fire pumps.
Due 15 February 2006
Resolved 25 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 February 2006
No resolution recorded
Remove bondo from main diesel engine saltwater supply lines and saltwater supply lines on auxiliary generators.
Condition: Improper/Lack of Maintenance
Due 15 February 2006 — due date passed with no resolution recorded
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 15 February 2006
Resolved
Provide high water alarms in all spaces with thru-hulls IAW 46 CFR 182.530
Due 15 February 2006
Resolved 25 July 2006
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 15 February 2006
Resolved
Provide shock proof matting for switch boards.
Due 15 February 2006
Resolved 25 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 February 2006
Resolved
Install metal fasteners for wiring throughout vessel IAW 46 CFR 183.340.
Due 15 February 2006
Resolved 25 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2006
Resolved
Provide machinery guards for main engines.
Due 15 February 2006
Resolved 25 July 2006
Engineering › Bilge Water Management System › Pump
Issued 15 February 2006
Resolved
Prove proper operation of bilge pump (marked manifold).
Due 15 February 2006
Resolved 25 July 2006
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 15 February 2006
Resolved
Provide portable lighting (1) at operation station and (1) at entrance to machinery space.
Due 15 February 2006
Resolved 25 July 2006
Documentation › Logs/Records › Logbook (official)
Issued 15 February 2006
Resolved
Provide log entries for EPIRB IAW 46 CFR 185.728.
Due 15 February 2006
Resolved 25 July 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 15 February 2006
Resolved
Provide guards for lighting fixtures IAW 46 CFR 183.410.
Due 15 February 2006
Resolved 25 July 2006
Fire Fighting › Fire Pumps › Power Source
Issued 15 February 2006
Resolved
Prove fire pump capable of remote operations from operating station IAW 46 CFR 181.300(e).
Due 15 February 2006
Resolved 25 July 2006
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 15 February 2006
Resolved
Prove operation of fire monitors.
Due 15 February 2006
Resolved 25 July 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 15 February 2006
Resolved
Provide proof of Passengers to be allowed on the upper deck, and maximum number allowed.
Due 15 February 2006
Resolved 25 July 2006
Documentation › Markings/Placards › Warning Signs
Issued 15 February 2006
Resolved
Mark "Emergency Exit Keep Clear" for means of escape IAW 46 CFR 177.500.
Due 15 February 2006
Resolved 25 July 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 15 February 2006
Resolved
Provide emergency lighting for the forward berthing area IAW 46 CFR 183.432.
Due 15 February 2006
Resolved 25 July 2006
Communications › Alarms/Indicators › General Alarm
Issued 15 February 2006
Resolved
Prove operation of general alarm system IAW 46 CFR 183.550.
Due 15 February 2006
Resolved 25 July 2006
Operations/Management › Drills/Instruction › Safety Orientation
Issued 15 February 2006
Resolved
Provide passengers safety orientation announcement or pamphlet IAW 46 CFR 185.506.
Due 15 February 2006
Resolved 25 July 2006
Construction/Loadline › Markings › Load Line Mark
Issued 15 February 2006
Resolved
Make load line in contrasting colors from hull.
Due 15 February 2006
Resolved 25 July 2006
Operations/Management › Passenger Operations › Safety Orientation
Issued 15 February 2006
Resolved
Vessel cannot carry passengers until Certificate of Inspection is approved by OCMI.
Due 15 February 2006
Resolved 25 July 2006
Construction/Loadline › Structures › Door
Issued 15 February 2006
Resolved
Replace cracked bridge windows (4).
Due 15 February 2006
Resolved 25 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 15 February 2006
Resolved
Submit repair propsal to OCMI. Provide vessel survey report and hull gauging report to OCMI.
Condition: Improper/Lack of Maintenance
Due 19 April 2006
Resolved 10 May 2006
Construction/Loadline › Structures › Door
Issued 15 February 2006
Resolved
Ensure all QAWTD's are operational.
Condition: Improper/Lack of Maintenance
Due 8 May 2006
Resolved 25 July 2006
Engineering › Bilge Water Management System › Pump
Issued 15 February 2006
Resolved
Provide bilge pump and high water alarms.
Condition: Unknown
Due 8 May 2006
Resolved 25 July 2006
Deck/Cargo › Mooring/Anchoring › Brake
Issued 15 February 2006
Resolved
Renew anchor brake pad IAW 46CFR184.300 due at next dry-dock.
Condition: Improper/Lack of Maintenance
Due 23 February 2007
Resolved 13 March 2008
Resolution: Brake bad has been renewed.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 15 February 2006
No resolution recorded
Provide CG approved vessel response plan prior to carrying cargo.
Condition: Unknown
Due 25 July 2006 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 February 2006
No resolution recorded
Prove proper operation of Amp meter for port generator IAW 46CFR183.330.
Condition: Unknown
Due 22 August 2006 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 June 2005
No resolution recorded
Replace section of flexible exhaust from port main engine that is cracked.
Due 14 July 2005 — due date passed with no resolution recorded
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 6 June 2005
Resolved
Replace gooseneck stdb fuel vent on main deck just forward of stbd brow on which a soft patch that appeares to have been in place for a long time was found. Correct at next drydock
Due 30 November 2006
Resolved 13 March 2008
Resolution: Gooseneck has been replaced.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 5 June 2005
Resolved
Found port main engine had three cracked cylinder heads and one cracked cylinder. Make necessary repairs to and prove proper operation of port main engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2005
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 23 February 2005
No resolution recorded
Anchor flluke bent and joint between shank and flukes severely worn. Repair or replace anchor.
Due 25 May 2006 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 May 2004
Resolved
Post all pages of COI in a conspicuous place where observation by passengers is likely.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2004
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 May 2004
Resolved
Implement a drug and alcohol testing program for all licensed employees and persons in critical safety positions.
Due 25 July 2004
Resolved 15 December 2004
Personnel › Training › Fire Fighting Basic
Issued 24 May 2004
Resolved
Provide and begin a training logbook.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 24 May 2004
Resolved
Begin a lifesaving equipment periodic inspection, testing, and maintenance record keeping system.
Due 24 June 2004
Resolved 18 June 2004
Documentation › Logs/Records › Logbook (official)
Issued 24 May 2004
Resolved
Logbook found with pages removed. No record of March 2004 vessel grounding. Begin a new official logbook.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2004
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 24 May 2004
Resolved
Provide a SOLAS training manual. SOLAS III/18-2
Due 24 June 2004
Resolved 18 June 2004
Resolution: Vessel restricted to 12 or fewer passengers on international voyages.
Documentation › Manifests/Lists › Shipping Papers
Issued 24 May 2004
Resolved
Begin providing voyage plans of which a copy is to be left at the inter-island ferry terminal. LEGACY COMPONENT DESC: Shipping Papers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 24 May 2004
Resolved
Post emergency instructions in the wheelhouse.
Due 24 June 2004
Resolved 18 June 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 24 May 2004
Resolved
Provide up-to-date CG Light List.
Due 24 June 2004
Resolved 23 February 2005
Documentation › Certificates/Documents › Passenger Ship Safety Certificate
Issued 24 May 2004
Resolved
Vessel not authorized to make international voyages with more than 12 passengers until a valid Passenger Ship Safety Certificate is issued.
Action required: 705 - Other - as specified
Resolved 18 June 2004
Resolution: Vessel operation permanently restricted as described in details. No Passenger Ship Safety Certificate issued.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 24 May 2004
Resolved
Vessel not authorized to make foreign voyages with more than 12 passengers until operating company and vessel are in full compliance with ISM and have been issued a document of compliance and safety management certificate.
Action required: 705 - Other - as specified
Resolved 18 June 2004
Resolution: Vessel operation permanently restricted as described in details.
Lifesaving › Hand Flares › Expired
Issued 24 May 2004
Resolved
Replace 4 expired day smoke signals and 2 red hand flares. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2004
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 24 May 2004
Resolved
Provide adequate means of escape from below deck crew berth. Hatch currently unusable without a ladder.
Due 24 June 2004
Resolved 17 August 2004
Resolution: ladder installed
Stability › Watertight Integrity › General
Issued 24 May 2004
Resolved
Make necessary adjustments/repairs to watertight door into steering compartment for proper operation and closure.
Due 24 June 2004
Resolved 7 September 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 May 2004
Resolved
Install chainlink fencing between rail courses in way of passenger area deck rails located aft of wheelhouse.
Due 24 June 2004
Resolved 18 June 2004
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 24 May 2004
Resolved
Remove matresses from deck in crew spaces. Only properly constructed bunks are authorized.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2004
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 24 May 2004
Resolved
Replace both expired hydrostatic release units.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 September 2004
Lifesaving › Lifebuoys › Serviceable
Issued 24 May 2004
Resolved
Replace or clean, add retro reflective tape to, and replace deteriorated grab line on ring buoy located on port side wheelhouse.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 May 2004
Resolved
Restock/replace first aid kit
Due 24 June 2004
Resolved 20 August 2004
Fire Fighting › Fire Hydrants › Condition
Issued 24 May 2004
Resolved
Replace broken valve hand wheel on fire hydrant located on forward bulkhead of main engine space.
Due 24 June 2004
Resolved 18 June 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 May 2004
Resolved
Replace missing guards on front of main engines and on ships service air compressor pulley assemblies.
Due 24 June 2004
Resolved 18 June 2004
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 May 2004
Resolved
Properly mark emergency escape routes from engine compartments.
Due 24 June 2004
Resolved 20 August 2004
Communications › Alarms/Indicators › General Alarm
Issued 24 May 2004
Resolved
Make repairs to general alarm bell in engine room.
Due 24 June 2004
Resolved 18 June 2004
Construction/Loadline › Structures › Door
Issued 24 May 2004
Resolved
Stencil both sides of all watertight doors "KEEP CLOSED WHILE UNDERWAY"
Due 24 June 2004
Resolved 20 August 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2004
Resolved
Prove proper operation of all remote fuel shut offs.
Due 2 June 2004
Resolved 18 June 2004
Engineering › Fuel Oil Service System › Valve, Control
Issued 24 May 2004
Resolved
Properly label fuel shut off valves
Due 24 June 2004
Resolved 20 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2004
Resolved
Properly mount wiring with metallic supports at least every 24 inches. Specifically, PA speaker located in below-deck passenger area and numerous overhead wiring runs throughout engine spaces.
Due 25 May 2005
Resolved 24 June 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2004
Resolved
Remove or repair bunk lights in below deck crew berthing in way of removed bunks.
Due 24 June 2004
Resolved 17 August 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 24 May 2004
Resolved
Provide a nonconducting mat or grating on deck in front of engine room switchboard.
Due 24 June 2004
Resolved 18 June 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2004
Resolved
Replace burned out lamps and missing light covers throughout vessel. Each light must have its cover properly installed.
Due 25 May 2005
Resolved 24 June 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 24 May 2004
Resolved
Remove unused wires and replace cover for electrical junction box located forward and above port main engine.
Due 24 June 2004
Resolved 7 September 2004
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 24 May 2004
Resolved
Stow child and adult PFDs separately. Stencil stowage accordingly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 May 2004
Resolved
Provide original Certificate of Documentation on board vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 24 May 2004
Resolved
Replace missing all-around red lights in a vertical line required for not under command condition.
Due 25 July 2004
Resolved 10 February 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 24 May 2004
Resolved
Repair/replace flood search light located on top of pilot house.
Due 25 July 2004
Resolved 20 August 2004
Resolution: Provided a 1000000 Candle Power hand held spot until fixed lights are repaired.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 24 May 2004
Resolved
Provide proof of or have portable fire extinguishers serviced.
Due 25 July 2004
Resolved 18 June 2004
Lifesaving › Inflatable Liferafts › Float Free
Issued 24 May 2004
Resolved
Reinforce deck and structure supporting inflatable liferafts and provide means of launching rafts by hand.
Due 25 July 2004
Resolved 18 June 2004
Resolution: Rafts relocated on solid deck. Removable float free bars and launch rails installed to enable allow hand launching without dropping rafts to deck below.
Lifesaving › Rescue Boat › Carriage Requirement
Issued 24 May 2004
Resolved
Provide a rescue boat in accordance with 46CFR180.210.
Due 31 August 2004
Resolved 20 August 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 24 May 2004
Resolved
Repair and exercise all machinery space vent closures. Demonstrate proper operation.
Due 25 July 2004
Resolved 23 February 2005
Fire Fighting › Means of Escape › Doorways
Issued 24 May 2004
Resolved
Make repairs to steering geer emergency escape hatch so as to achieve watertight integrity.
Due 25 July 2004
Resolved 7 September 2004
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 May 2004
Resolved
Make necessary repairs to anchor system. Demonstrate proper operation.
Due 25 May 2005
Resolved 23 February 2005
Resolution: Anchor windlass tested SAT. Found anchor to be deformed and with excessive slop where shank and flukes are pinned together.
Deck/Cargo › Cargo Stowage › General
Issued 24 May 2004
Resolved
Properly lash deck containers to prevent shifting underway.
Due 25 July 2004
Resolved 17 August 2004
Construction/Loadline › Hull
Issued 1 July 2003
Resolved
Make permanent repair: Crop and renew in kind the side shell hull plating in way of the starboard side engine room underneath the entrance hatch where wasted and holed. Crop to good steel and insert is to have radiused corners and/or 6" relief cuts. Repair area extends below the waterline. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2003
Resolved 8 July 2003
Resolution: New hull plating permanently welded in place. Examined repair and watertight integrity w/no further deficiencies note. Plating coated w/marine antifouling paint coating.
Construction/Loadline › Hull
Issued 1 July 2003
Resolved
Make permanent repair: Crop and renew in kind the side shell hull plating in way of the port side engine room underneath the entrance hatch where wasted and holed. Crop to good steel and insert is to have radiused corners and/or 6" relief cuts. Repair area extends below the waterline. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 8 July 2003
Resolution: New hull plating permanently welded in place. Examined repair and watertight integrity w/no further deficiencies note. Plating coated w/marine antifouling paint coating.
Construction/Loadline › Hull › Stiffener
Issued 1 July 2003
Resolved
Make permanent repair: Crop and renew in kind the wasted longitudinal framing and stiffeners on the starboard side sideshell, where holed and wasted. Minimum of 18" required for replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2003
Resolved 8 July 2003
Resolution: Observed permanent repairs to sideshell longitudinals and stiffeners w/no further deficiencies noted. Angle iron was 100% welded both sides.
Construction/Loadline › Hull › Stiffener
Issued 1 July 2003
Resolved
Make permanent repair: Crop and renew in kind the wasted longitudinal framing and stiffeners on the port side sideshell, where holed and wasted. Minimum of 18" required for replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2003
Resolved 8 July 2003
Resolution: Observed permanent repairs to framing and stiffeners on port side enginer room side shell; repairs were welded 100% both sides and all repairs were more than the 18" minimum.
Construction/Loadline › Penetrations › Gasket
Issued 1 July 2003
Resolved
Renew gaskets on entrance hatchways to the ship's engine room, both port and starboard sides.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2003
Resolved 8 July 2003
Resolution: Gaskets renewed w/proper material and watertight.
Construction/Loadline › Hull
Issued 1 July 2003
Resolved
Crop and renew section of wasted steel in way of the engine room centerline #3 double bottom fuel oil tank, where wasted. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 July 2003
Resolved 8 July 2003
Resolution: Permanent repairs made after fuel tank was cleaned and gas freed. A minimum 18" x 18" insert was made. NDT was performed on the welds w/no leaks indicated.
Construction/Loadline › Hull › Hull Plating
Issued 1 July 2003
Resolved
Provide hull thickness gauging report of the vessel's wind & water line, as well as thickness gaugings around repair areas: port and starboard enginer room, and #3 fuel oil double bottom tank. LEGACY COMPONENT DESC: Gauging Report
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 7 July 2003
Construction/Loadline › Hull › Hull Plating
Issued 1 July 2003
Resolved
Provide a copy of the shipyard lists of materials used, repairs documents and any other related forms pertaining to the drydocking of the vessel. LEGACY COMPONENT DESC: Shipyard Documents & Repair Forms
Action required: 705 - Other - as specified
Due 31 July 2003
Resolved 7 July 2003
Lifesaving › Rocket Parachute Flares
Issued 21 May 2002
Resolved
Provide two (2) additional rocket distress signals on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2002
Resolved 11 December 2002
Lifesaving › Buoyant Smoke Signals
Issued 21 May 2002
Resolved
Provide two (2) additional smoke distress signals on board the vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2002
Resolved 11 December 2002
Lifesaving › Inflatable Liferafts
Issued 21 May 2002
Resolved
Relocated or properly install inflatable liferafts & EPIRB so that they are float free, without any overhead obstructions.
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 May 2002
Resolved
Properly label all new PFD's and ring life buoy with the vessel's name. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 21 May 2002
Resolved
Proper stow all adult and child-sized lifejackets. Child jackets are to be kept separate from adult jackets and all closets/storage lockers are to be labeled according to type of jacket enclosed inside. LEGACY COMPONENT DESC: Storage
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Communications › Internal Communications System
Issued 21 May 2002
Resolved
Install a public address system insde of the vessel, in all appropriate passenger and crew areas.
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Engineering › Bilge Water Management System
Issued 21 May 2002
Resolved
Provide a hand portable bilge water pump on board the vessel. LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Construction/Loadline › Structures
Issued 21 May 2002
Resolved
Properly install a watertight door between the forward and aft engine room compartments. LEGACY COMPONENT DESC: Door
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Engineering
Issued 21 May 2002
Resolved
Properly install a bilge level alarm in the engineering compartment w/an audible & visual signal displayed in the pilot house.
Action required: 705 - Other - as specified
Due 21 July 2002
Resolved 11 December 2002
Navigation
Issued 7 August 2001
Resolved
Install an all-round red navigational light for night time transfers of dangerous cargoes, or provide letter indicating intent of day time transfers only; prior to conducting night transfers.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Documentation
Issued 7 August 2001
Resolved
Provide gangway warning placard/sign in accordance with 46 CFR 35.30-1.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Fire Fighting
Issued 7 August 2001
Resolved
Prior to conducting cargo operations, provide a BV semi-portable fire extinguisher on board the vessel.
Condition: Unknown
Due 7 September 2001
Resolved 21 May 2002
Resolution: BV semi-portable fire ext. brought on board when fuel oil is carried as cargo.
Documentation
Issued 7 August 2001
Resolved
Prior to conducting any transfer of cargo, provide a letter designating persons-in-charge of an oil transfer, and ensure PIC meets requirements of 33 CFR 155.710. See also 33 CFR 155.715.
Condition: Unknown
Due 26 October 2001
Resolved 5 November 2001
Deck/Cargo
Issued 7 August 2001
Resolved
Properly pressure test cargo piping in accordance with 46 CFR 38.10-10 and prior to conducting a cargo transfer.
Condition: Unknown
Due 7 September 2001
Resolved 21 May 2002
Resolution: Piping tested to 1.5 MAWP.
Deck/Cargo
Issued 7 August 2001
Resolved
Provide a cargo pump discharge pressure gauge prior to commencing cargo operations.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Deck/Cargo
Issued 7 August 2001
Resolved
Install new manifold shut-off valve prior to conducting any cargo operations.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Deck/Cargo
Issued 7 August 2001
Resolved
Provide portable oil containment for manifold flange and for each tank vent, prior to conducting any cargo operations.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Documentation
Issued 7 August 2001
Resolved
Provide and post MSDS sheet for cargo carried (diesel no. 2) prior to cargooperations.
Condition: Unknown
Due 23 October 2001
Resolved 5 November 2001
Lifesaving
Issued 27 February 2001
Resolved
Vessel is limited to 22 adult passengers until additional CG approved adultPFDs are provided.
Condition: Unknown
Due 27 February 2001
Resolved 21 May 2002
Resolution: Vessel procured more lifejackets & now has 50+ adult PFD''s on board w/lights and whisltes.
Lifesaving
Issued 27 February 2001
Resolved
Vessel is not authorized to carry children until CG approved child-sized lifejackets are provided.
Condition: Unknown
Due 27 March 2001
Resolved 21 May 2002
Resolution: Vessel has 15 approved child-sized PFD''s on board.
Construction/Loadline
Issued 4 November 1996
Resolved
Make available for inspection the starboard propeller, starboard strut, starboard cutlass bearing, and starboard aft quarter (below the waterline).
Condition: Unknown
Due 17 December 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 30 October 1996
Resolved
Crop and renew the "I" beam which supports the port steering gear ram.
Condition: Unknown
Due 30 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 30 October 1996
Resolved
Reinstall the relief valve on the out board pressure vessel located in the engineroom, port side. The pressure vessel must remain isolated, until therelief valve is installed and operationally tested to the satisfaction of aUSCG inspector.
Condition: Unknown
Due 30 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 30 October 1996
Resolved
Service both the port and starboard liferafts.
Condition: Unknown
Due 30 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 30 October 1996
Resolved
Properly service or replace the buoyant apparatus. The apparatus has several cuts that are greater then 1/2" in depth.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 8 July 1996
Resolved
Make permanent repairs to the 12" fracture located on the port bow, 1 1/2" aft of the stem, 4 1/2' above the waterline. The vessel is restricted fromoperating until the above repair is made.
Condition: Unknown
Due 8 July 1996
Resolved 5 August 1996
Construction/Loadline
Issued 24 February 1996
Resolved
MAKE PERMANENT REPAIR TO THE ACCESS PLATE IN THE INBOARD SIDE OF THE PORT STACK. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 February 1996
Resolved 24 February 1996
Lifesaving
Issued 19 October 1995
Resolved
Provide three Coast Guard Approved ring buoys.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Electrical
Issued 19 October 1995
Resolved
RE-INTALL THE EMERGENCY LIGHTING IN THE PASSENGER LOUNGE.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Lifesaving
Issued 19 October 1995
Resolved
Apply retrorefletive material to both sides of the Buoyant Apparatus.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Lifesaving
Issued 19 October 1995
Resolved
Install a Coast Guard approved weak link for the Buoyant Apparatus.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Fire Fighting
Issued 19 October 1995
Resolved
RENEW ALL (3) FIRE HOSES ON BOARD VESSEL.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Lifesaving
Issued 19 October 1995
Resolved
Provide three adult PFDs, with attached lights and whistles, for a total of46 adult PFDs.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Lifesaving
Issued 8 August 1995
Resolved
Renew as original the sea painter for the buoyant apparatus on the pilot house prior to vessel operation.
Condition: Unknown
Due 8 August 1995
Resolved 9 August 1995
Lifesaving
Issued 8 August 1995
Resolved
Prove proper operation of the waterlight for the ring buoy located aft of the pilot house on the 01 deck prior to operating the vessel.
Condition: Unknown
Due 8 August 1995
Resolved 9 August 1995
Deck/Cargo
Issued 8 August 1995
Resolved
Make permanent repair to the anchor winch no later than October 1, 1995.
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Deck/Cargo
Issued 1 August 1995
Resolved
PROVE PROPER OPERATION OF ANCHOR WINCH
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Navigation
Issued 1 August 1995
Resolved
PROVE PROPER OPERATION OF ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Fire Fighting
Issued 1 August 1995
Resolved
PROVE PROPER OPERATION OF BOTH FIRE PUMPS.
Condition: Unknown
Due 1 August 1995
Resolved 1 August 1995
Lifesaving
Issued 4 April 1995
Resolved
Provide 9 additional lifejackets to bring total number of inspected adult lifejackets to 46.
Condition: Unknown
Due 4 April 1995
Resolved 4 April 1995
Electrical
Issued 13 October 1994
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTS, PRIOR TO NEXT VOYAGE.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Construction/Loadline
Issued 13 October 1994
Resolved
PROVE OPERATION OF SHAFT ALLEY BILGE SUCTION, PRIOR TO NEXT VOYAGE.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 13 October 1994
Resolved
INSTALL SECOND 25-MAN LIFERAFT ABOARD VESSEL. VESSEL IS LIMITED TO THE CARRIAGE OF NOT MORE THAN 25 PERSONS UNTIL SECOND RAFT IS INSTALLED.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 13 October 1994
Resolved
PROVIDE LIGHTS FOR 26 ADDITIONAL LIFEJACKETS. VESSEL IS LIMITED TO TOTAL PASSENGER AND CREW COMPLENT OF 26 ADULTS AND 3 CHILDREN UNTIL LIGHTS HAVE BEEN INSTALLED.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Accommodation/Occupational Safety
Issued 13 October 1994
Resolved
PROVE SATISFACTORY OPERATION OF INSTALLED TYPE II MARINE SANITATION DEVICE.VESSEL IS REQUIRED TO CARRY OTHER MEANS FOR HANDLING SEWAGE FOR OPERATION WITHIN 3 MILES OF LAND.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 24 June 1994
Resolved
Conduct annual servicing of liferafts. Total number of passengers and crewis limited to 25 persons based on replacement liferaft placed on vessel.
Condition: Unknown
Due 24 June 1994
Resolved 24 June 1994
Deck/Cargo
Issued 8 November 1993
Resolved
REPLACE MISSING ANCHOR
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Navigation
Issued 8 November 1993
Resolved
PROVE OPERATION OF SINGLE SIDE BAND RADIO INSTALLED ON VESSEL.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Navigation
Issued 14 September 1993
Resolved
CALIBRATE MAGNETIC COMPASS IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Navigation
Issued 14 September 1993
Resolved
PROVE PROPER OPERATION OF VESSEL'S RADAR.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993
Resolved
REPLACE BATTERY AND PROVE OPERATION OF VESSEL'S EPRIB
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Navigation
Issued 14 September 1993
Resolved
PROVE OPERATION OF INSTALLED SATNAV SYSTEM
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 14 September 1993
Resolved
PROVIDE 6 HAND HELD AND 6 SMOKE FLARES.
Condition: Unknown
Due 14 September 1993
Resolved 14 September 1993
Lifesaving
Issued 22 June 1993
Resolved
PROVIDE 6 HAND ORANGE SMOKE AND 6 HAND HELD RED FLARES.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Lifesaving
Issued 22 June 1993
Resolved
REQUIRED TO REPLACE OUTDATED PFD LIGHTS WHICH EXPIRE ONE MONTH AFTER ISSUANCE OF COI.
Condition: Unknown
Due 31 August 1993
Resolved 7 July 1993
Navigation
Issued 22 June 1993
Resolved
PROVE PROPER OPERATION OF THE FATHOMETER.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Engineering
Issued 22 June 1993
Resolved
PROVE PROPER OPERATION OF THE RELIEF VALVE ON STBD SIDE AIR RECEIVER TO RELIEVE AT 175 PSI.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Electrical
Issued 22 June 1993
Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIPS ON THE PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Construction/Loadline
Issued 22 June 1993
Resolved
UNPLUG DRAIN IN ACCOMODATION AREA.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Fire Fighting
Issued 22 June 1993
Resolved
PROPERLY REPAIR AND PROVE PROPER OPERATION OF THE PLUGGED STARBOARD FIRE MONITOR PRIOR TO NEXT VOYAGE.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Fire Fighting
Issued 22 June 1993
Resolved
PROPERLY MOUNT PORTABLE DRY CHEMICAL EXTINGUISHER IN ENGINE ROOM AS PER POSTED FIRE FIGHTING GEAR PLAN.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Documentation
Issued 22 April 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Documentation
Issued 22 April 1992
Resolved
PROVIDE AN FCC SAFETY RADIOTELEPHONE CERTIFICATE._x001C_
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Navigation
Issued 23 January 1992
Resolved
MAKE RADAR OPERATIONAL.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Accommodation/Occupational Safety
Issued 23 January 1992
Resolved
REMOVE ALL PAINT AND FLAMABLE LIQUIDS FROM ACCOMIDATIONS.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Electrical
Issued 23 January 1992
Resolved
MAKE ALL EMERGENCY LIGHTS OPERATIONAL.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Accommodation/Occupational Safety
Issued 23 January 1992
Resolved
REPAIR FORWARD PORT TOILET.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Lifesaving
Issued 23 January 1992
Resolved
PROVIDE LIGHTS AND WHISTLES FOR ALL REJECTED PFD'S (16).
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Fire Fighting
Issued 23 January 1992
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Unknown
Issued 23 January 1992
Resolved
REPAIR CRACKED WINDOW (PORT LIGHT) PORT SIDE ON GALLEY DECK.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Engineering
Issued 23 January 1992
Resolved
OPERATIONALLY TEST AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Electrical
Issued 23 January 1992
Resolved
TEST OVERSPEED ON PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Lifesaving
Issued 23 January 1992
Resolved
SERVICE P/S LIFERAFTS.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Documentation
Issued 23 January 1992
Resolved
PROVIDE VALID FCC RADIO STATION LICENSE.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Lifesaving
Issued 23 January 1992
Resolved
PROVIDE FIRST AID KIT.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Documentation
Issued 23 January 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Fire Fighting
Issued 23 January 1992
Resolved
REPAIR FIRE ALARM IN ENGINE ROOM.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Unknown
Issued 23 January 1992
Resolved
PROVIDE STATION BILL.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Lifesaving
Issued 23 January 1992
Resolved
REPAIR SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Navigation
Issued 23 January 1992
Resolved
MAKE FATHOMETER OPERATIONAL.
Condition: Unknown
Due 23 January 1992
Resolved 23 January 1992
Unknown
Issued 29 January 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Unknown
Issued 29 January 1991
Resolved
Fix exhaust leak from STBD engine (in engine room).
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Unknown
Issued 29 January 1991
Resolved
Make operable the vessel's radair.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Unknown
Issued 29 January 1991
Resolved
Provide to [name withheld] a liferaft servicing report for liferaft #1 serial #25mmus9._x001C_
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Unknown
Issued 29 January 1991
Resolved
Provide onboard a valid Certificate of Documentation.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Unknown
Issued 29 January 1991
Resolved
Tighten packing on STBD rudder.
Condition: Unknown
Due 29 January 1991
Resolved 29 January 1991
Construction/Loadline
Issued 16 April 1985
Resolved
MAKE PERMANENT REPAIRS TO WORNOUT SECURING BARS (DOGS) TO QUICK ACTING WATERTIGHT DOOR ON FORWARD ENTRANCE TO ENGINEROOM.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985