← All vessels
SANTA YNEZ
SANTA YNEZ is a 1963 tank barge. The Coast Guard has recorded 47 inspections since 1985, most recently in September 1995, along with 67 deficiencies.
Records from 1985 to 1995. Most recent: inspection, 10 September 1995.
- Built
- 1963
- Last inspected
- 10 September 1995
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 67 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
618372
WCM2131
52105
Flag
UNITED STATES
—
Maury page id
psix-52105
Inspections, by type
…with no type recorded23
Years with a record
11 calendar years (1985–1995)
The 47 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Tonnage as PSIX records it21136 - Regulatory (Subpart C or D), Net Ton
21136 - Regulatory (Subpart C or D), Gross Ton
21136 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WCM2131MMSI not assigned · expired · compulsorily equipped · granted 23 August 1994, cancelled 23 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 47
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878960
21 October 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372030
1 October 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 163411
17 May 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859530
28 February 1994
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435475
4 August 1993
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 647718
28 July 1993
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 55172
15 June 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840771
24 April 1993
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 60074
8 March 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1148223
16 February 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1151631
16 February 1993
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382527
3 February 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 962848
15 January 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376914
26 September 1992
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 58279
26 February 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356107
27 January 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1389543
15 August 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1250683
23 May 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 925545
30 April 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901241
19 April 1991
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228155
1 February 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996491
2 August 1990
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 915264
26 June 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1219095
1 February 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908335
24 October 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200723
28 August 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1033635
15 August 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1352546
10 March 1989
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204632
30 January 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207477
11 April 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1347112
23 March 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292863
8 March 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336663
23 February 1988
Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336654
5 March 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007094
30 January 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318239
26 September 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008220
18 September 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003376
4 March 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998772
14 January 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1299479
17 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989657
27 August 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992383
19 August 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292829
15 August 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985762
23 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978344
22 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982928
20 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288480
Deficiency record · 67
Deck/Cargo
Issued 27 January 1992
Resolved
Prove proper operation of the following pressure relief devices:_x001C_ (a) Pressurized water tank in foam room._x001C_ (b) Sullar 32 (42-302B) in machinery space #2.
Accommodation/Occupational Safety
Issued 27 January 1992
Resolved
Clean and properly stow record keeping spaces outboard of gym.
Fire Fighting
Issued 27 January 1992
Resolved
Repair leaking fire main hydrants and monitors.
Fire Fighting
Issued 27 January 1992
Resolved
Provide pull chains for ventilation dampers throughout vessel.
Deck/Cargo
Issued 27 January 1992
Resolved
Clean after pumproom ventilation ducting of oil.
Deck/Cargo
Issued 27 January 1992
Resolved
Repair PV devices on cargo pumps "C" & "D", in after pumproom.
Electrical
Issued 27 January 1992
Resolved
Install rubber matting in Motor Control Center in Main/Forward switchgear room behind MCC6.
Electrical
Issued 27 January 1992
Resolved
Provide metallic covers for panel A2-103A.
Deck/Cargo
Issued 27 January 1992
Resolved
Submit for approval, piping diagrams for regeneration system located in _x001C_ machinery space. Mail to: USCG Marine Safety Detachment_x001C_ 111 Harbor Way_x001C_ Santa Barbara, CA 93109-2315
Electrical
Issued 27 January 1992
Resolved
Provide proper marking for emergency lighting on boat deck around house.
Construction/Loadline
Issued 27 January 1992
Resolved
Crop and renew to original condition the housing for turbine room supply vent at the port side boat deck.
Lifesaving
Issued 27 January 1992
Resolved
Properly secure compressed gas bottles throughout vessel.
Construction/Loadline
Issued 27 January 1992
Resolved
Inspect and adjust all watertight doors.
Fire Fighting
Issued 1 February 1991
Resolved
Provide copy of organic foam sample analysis report to the USCG Marine Safety Detachment at 111 Harbor Way, Santa Barbara, CA 93109-2315.
Fire Fighting
Issued 1 February 1991
Resolved
Provide firefighting lifeline of adequate length in accordance with 46 CFR 35.30-20(e)
Lifesaving
Issued 1 February 1991
Resolved
Replace wasted hand crank for #1 lifeboat winch.
Lifesaving
Issued 1 February 1991
Resolved
Demonstrate satisfactory operational tests of #3 lifeboat prior to it's use. Provide approved plans of installation to the USCG Marine Safety Detachment at 111 Harbor Way, Santa Barbara, CA 93109-2315.
Lifesaving
Issued 1 February 1991
Resolved
Provide dates of last renewal of #1 & 2 lifeboat falls.
Fire Fighting
Issued 1 February 1991
Resolved
Make permanent repair to the door latch at switchgear to turbine room, portside.
Fire Fighting
Issued 1 February 1991
Resolved
Renew structural fire protection insulation at:_x001C_ a) starboard side of transformer room near overhead._x001C_ b) aft turbine room mezanine overhead and bulkhead.
Documentation
Issued 1 February 1991
Resolved
Provide vessel with a copy of Revision #2 to Trim and Stability Booklet (USCG approval date 22OCT81).
Deck/Cargo
Issued 1 February 1991
Resolved
Provide drip pan under crane.
Deck/Cargo
Issued 1 February 1991
Resolved
Prove proper operation of bow mooring system. This includes satisfactory test of windlass and brake, as well as an inspection of anchor and chain.
Construction/Loadline
Issued 2 August 1990
Resolved
PROVIDE A COPY OF THE UNDERWATER SURVEY VIDEO TAPE TO THE MARINE SAFETY DETACHMENT IN SANTA BARBARA.
Construction/Loadline
Issued 2 August 1990
Resolved
PROVIDE A COPY OF THE ULTRASONIC GAUGINGS REPORT TAKEN DURING THE UNDER- WATER IN LIEU OF DRYDOCKING EXAM TO THE MARINE SAFETY DETACHMENT IN SANTA BARBARA.
Construction/Loadline
Issued 2 August 1990
Resolved
REPAIR FRACTURED WELD TO VERTICAL STIFFENER BRACKET ABOVE SEACHEST #20 IN AFT MACHINERY SPACE.
Construction/Loadline
Issued 2 August 1990
Resolved
OPEN FOR INSPECTION AT LEAST TWO MORE SALT WATER BALLAST TANK DISCHARGE VALVES THIS EXAM AND THE BALANCE AT NEXT DRYDOCKING OR UNDERWATER EXAM IN LIEU OF DRYDOCKING.
Construction/Loadline
Issued 26 June 1990
Resolved
EITHER PROVE #4 PORT DOUBLE BOTTOM WATER TIGHT OR WELD UP PINHOLE LEAK AT 1ST FRAME IN LONGITUDINAL BULKHEAD.
Construction/Loadline
Issued 26 June 1990
Resolved
REPAIR LEAKING PACKING IN BALLAST INTAKE SEAVALVE AT #9 STBD SALTWATER BALLAST TANK.
Construction/Loadline
Issued 26 June 1990
Resolved
PROVIDE COPY OF ULTRASONIC GUAGING REPORT TAKEN DURING INTERNAL EXAMS.
Lifesaving
Issued 1 February 1990
Resolved
CONDUCT HYDROSTATIC TEST OF LIFEBOAT AIR BOTTLES.
Construction/Loadline
Issued 1 February 1990
Resolved
INSERT ALL BOLTS IN PUMPROOM ACCESS HATCH, OR PROVIDE ALTERNATIVE MEANS OF MAKING HATCH FAST.
Electrical
Issued 1 February 1990
Resolved
PROPERLY BLOCK BATTERIES IN AUXILIARY GENERATOR BATTERY BOX.
Fire Fighting
Issued 1 February 1990
Resolved
REPAIR ALL LEAKING FIRE MONITORS ON MAIN DECK AREA.
Fire Fighting
Issued 1 February 1990
Resolved
REPAIR AND PROVE PROPER OPERATION OF EMERGENCY DIESEL DRIVEN FIRE PUMP.
Fire Fighting
Issued 1 February 1990
Resolved
PROVIDE PERMANENT STORAGE RACKS FOR ALL NITROGEN BOTTLES.
Lifesaving
Issued 1 February 1990
Resolved
RENEW GASKET ON #1 LIFEBOAT HATCH.
Electrical
Issued 1 February 1990
Resolved
CLEAN OIL FROM AUXILIARY GENERATOR CONTROL ROOM DECK.
Construction/Loadline
Issued 28 August 1989
Resolved
PROVIDE MARINE SAFETY DETACHMENT SANTA BARBARA WITH A COPY OF THE GAGING REPORT PREPARED FOR EXXON DURING THE AUGUST 1989 TANK INSPECTIONS.
Construction/Loadline
Issued 30 January 1989
Resolved
REPLACE OR REPAIR 3 DOG LATCHES ON TWO HATCHES TO THE MPDU COMPARTMENT ON SALMS.
Fire Fighting
Issued 30 January 1989
Resolved
REPLACE TIME DELAYS FOR FIXED HALON SYSTEMS AT T-8 MAIN TRANSFORMER AND DIESEL FIRE PUMP SPACE.
Deck/Cargo
Issued 30 January 1989
Resolved
PROVIDE EVIDENCE OF CARGO HOSE BEING TESTED TO 1 1/2 TIMES THE MAWP (AT LEAST 225 PSI).
Deck/Cargo
Issued 30 January 1989
Resolved
CLEAR PUMPROOM BILGES; LOCATE/REPAIR SOURCES OF OIL LEAKS.
Fire Fighting
Issued 30 January 1989
Resolved
PROVIDE SERVICE REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Electrical
Issued 23 February 1988
Resolved
LABEL ELECTRICAL PANELS IN GALLEY.
Fire Fighting
Issued 23 February 1988
Resolved
REPLACE FOUR TEN FOOT FIRE APPLICATORS WITH 4 FOOT APPLICATOR IN MACHINERY SPACES.
Construction/Loadline
Issued 23 February 1988
Resolved
PROVIDE VIDEO TAPE AND UNDERWATER SURVEY REPORT.
Fire Fighting
Issued 23 February 1988
Resolved
REPAIR LOOSE WIRING FOR SOLENOID CONTROLS TO T-7 TRANSFORMER AND EMERGENCY GENERATOR.
Fire Fighting
Issued 23 February 1988
Resolved
SERVICE FOUR OVER PRESSURIZED HALON CYLINDERS.
Fire Fighting
Issued 23 February 1988
Resolved
SERVICE FOUR UNDERPRESSURIZED HALON CYLINDERS.
Fire Fighting
Issued 23 February 1988
Resolved
REPAIR SOLENOID SWITCH AT AUX. GENERATOR.
Lifesaving
Issued 23 February 1988
Resolved
REPAIR DAMAGED LIFE RAFT SHELL NUMBER 4 LIFERAFT.
Deck/Cargo
Issued 23 February 1988
Resolved
PROVIDE ANCHOR CHAIN AND PROVE OPERATION OF BRAKE AND WINDLESS.
Accommodation/Occupational Safety
Issued 23 February 1988
Resolved
CLEAN GALLEY EXHAUST DUCT.
Fire Fighting
Issued 23 February 1988
Resolved
REPAIR LEAK TO FIRE MAIN PIPE AT STATION NUMBER 5.
Lifesaving
Issued 23 February 1988
Resolved
PROVIDE WEAK LINKS FOR LIFE RAFT NUMBER 5 AND 6.
Fire Fighting
Issued 23 February 1988
Resolved
REPAIR OR REPLACE SV15 MAIN SOLENOID SWITCH FOR T-8 HALON SYSTOM.
Navigation
Issued 30 January 1987
Resolved
REPAIR RELIEF VALVES TO MAIN AIR RECEIVER.
Navigation
Issued 30 January 1987
Resolved
REPAIR RELIEF VALVE TO FIRE WATER JOCKEY TANK.
Fire Fighting
Issued 30 January 1987
Resolved
REPAIR FIRE NOZZLES AND FIRE APPLICATORS THROUGHOUT VESSEL.
Fire Fighting
Issued 30 January 1987
Resolved
RENEW HOLED SECTION OF FIRE PIPE TO NUMBER 3 AUX. FIRE PUMP
Fire Fighting
Issued 30 January 1987
Resolved
PROVIDE SCHMATIC DRAWINGS FOR ALL HALON SYSTEMS.
Lifesaving
Issued 30 January 1987
Resolved
REPAIR OR RENEW HANGERS FOR RING BUOY LIGHTS AND LINE HOLDERS, VARIOUS LOCATIONS THROUGHOUT VESSEL.
Fire Fighting
Issued 30 January 1987
Resolved
CONDUCT TEST TO HALON SYSTEM TO AUX GENERATOR, STBD TURBINE AND GENERATOR.
Electrical
Issued 30 January 1987
Resolved
CLOSE OPENINGS ON SWITCHBOARD, OUTBOARD OF AUX. GEN., PORT SIDE.
Documentation
Issued 30 January 1987
Resolved
RENEW MARINE DOCUMENT, SHOWING CORRECT OWNER AND ADDRESS.
Electrical
Issued 30 January 1987
Resolved
REPAIR OR RENEW WIRE RUN HANGERS IN VARIOUS LOCATIONS ON MAIN DECK AND 01 DECK.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.