MAURY USCG vessel records
← All vessels

SANTA YNEZ

SANTA YNEZ is a 1963 tank barge. The Coast Guard has recorded 47 inspections since 1985, most recently in September 1995, along with 67 deficiencies.

Records from 1985 to 1995. Most recent: inspection, 10 September 1995.

Built
1963
Last inspected
10 September 1995
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 10 September 1995
…with no type recorded23
Operational controls None recorded without a removal date
Years with a record 11 calendar years (1985–1995)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCM2131
Flag
UNITED STATES
Maury page id
psix-52105

Documentation record

Tonnage as PSIX records it21136 - Regulatory (Subpart C or D), Gross Ton
21136 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

47 inspections, each with its date, unit and type; 67 deficiencies with the resolution recorded against each; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 47

10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878960
21 October 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 372030
1 October 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 163411
17 May 1994 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859530
28 February 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1435475
4 August 1993 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 647718
28 July 1993 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 55172
15 June 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 840771
24 April 1993 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 60074
8 March 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1148223
16 February 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1151631
16 February 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1382527
3 February 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 962848
15 January 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376914
26 September 1992 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 58279
26 February 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356107
27 January 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1389543
15 August 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1250683
23 May 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 925545
30 April 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 901241
19 April 1991 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1228155
1 February 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996491
2 August 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 915264
26 June 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1219095
1 February 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 908335
24 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1200723
28 August 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1033635
15 August 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1352546
10 March 1989 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1204632
30 January 1989 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1207477
11 April 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1347112
23 March 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292863
8 March 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336663
23 February 1988 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1336654
5 March 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007094
30 January 1987 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1318239
26 September 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1008220
18 September 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003376
4 March 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998772
14 January 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1299479
17 September 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989657
27 August 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992383
19 August 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292829
15 August 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985762
23 July 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978344
22 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982928
20 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288480

Deficiency record · 67

Deck/Cargo
Issued 27 January 1992 Resolved
Prove proper operation of the following pressure relief devices:_x001C_ (a) Pressurized water tank in foam room._x001C_ (b) Sullar 32 (42-302B) in machinery space #2.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Accommodation/Occupational Safety
Issued 27 January 1992 Resolved
Clean and properly stow record keeping spaces outboard of gym.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Fire Fighting
Issued 27 January 1992 Resolved
Repair leaking fire main hydrants and monitors.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Fire Fighting
Issued 27 January 1992 Resolved
Provide pull chains for ventilation dampers throughout vessel.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 27 January 1992 Resolved
Clean after pumproom ventilation ducting of oil.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 27 January 1992 Resolved
Repair PV devices on cargo pumps "C" & "D", in after pumproom.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Electrical
Issued 27 January 1992 Resolved
Install rubber matting in Motor Control Center in Main/Forward switchgear room behind MCC6.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Electrical
Issued 27 January 1992 Resolved
Provide metallic covers for panel A2-103A.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Deck/Cargo
Issued 27 January 1992 Resolved
Submit for approval, piping diagrams for regeneration system located in _x001C_ machinery space. Mail to: USCG Marine Safety Detachment_x001C_ 111 Harbor Way_x001C_ Santa Barbara, CA 93109-2315
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Electrical
Issued 27 January 1992 Resolved
Provide proper marking for emergency lighting on boat deck around house.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 27 January 1992 Resolved
Crop and renew to original condition the housing for turbine room supply vent at the port side boat deck.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Lifesaving
Issued 27 January 1992 Resolved
Properly secure compressed gas bottles throughout vessel.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Construction/Loadline
Issued 27 January 1992 Resolved
Inspect and adjust all watertight doors.
Condition: Unknown
Due 27 January 1992
Resolved 27 January 1992
Fire Fighting
Issued 1 February 1991 Resolved
Provide copy of organic foam sample analysis report to the USCG Marine Safety Detachment at 111 Harbor Way, Santa Barbara, CA 93109-2315.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Fire Fighting
Issued 1 February 1991 Resolved
Provide firefighting lifeline of adequate length in accordance with 46 CFR 35.30-20(e)
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Lifesaving
Issued 1 February 1991 Resolved
Replace wasted hand crank for #1 lifeboat winch.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Lifesaving
Issued 1 February 1991 Resolved
Demonstrate satisfactory operational tests of #3 lifeboat prior to it's use. Provide approved plans of installation to the USCG Marine Safety Detachment at 111 Harbor Way, Santa Barbara, CA 93109-2315.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Lifesaving
Issued 1 February 1991 Resolved
Provide dates of last renewal of #1 & 2 lifeboat falls.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Fire Fighting
Issued 1 February 1991 Resolved
Make permanent repair to the door latch at switchgear to turbine room, portside.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Fire Fighting
Issued 1 February 1991 Resolved
Renew structural fire protection insulation at:_x001C_ a) starboard side of transformer room near overhead._x001C_ b) aft turbine room mezanine overhead and bulkhead.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Documentation
Issued 1 February 1991 Resolved
Provide vessel with a copy of Revision #2 to Trim and Stability Booklet (USCG approval date 22OCT81).
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Deck/Cargo
Issued 1 February 1991 Resolved
Provide drip pan under crane.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Deck/Cargo
Issued 1 February 1991 Resolved
Prove proper operation of bow mooring system. This includes satisfactory test of windlass and brake, as well as an inspection of anchor and chain.
Condition: Unknown
Due 1 February 1991
Resolved 1 February 1991
Construction/Loadline
Issued 2 August 1990 Resolved
PROVIDE A COPY OF THE UNDERWATER SURVEY VIDEO TAPE TO THE MARINE SAFETY DETACHMENT IN SANTA BARBARA.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Construction/Loadline
Issued 2 August 1990 Resolved
PROVIDE A COPY OF THE ULTRASONIC GAUGINGS REPORT TAKEN DURING THE UNDER- WATER IN LIEU OF DRYDOCKING EXAM TO THE MARINE SAFETY DETACHMENT IN SANTA BARBARA.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Construction/Loadline
Issued 2 August 1990 Resolved
REPAIR FRACTURED WELD TO VERTICAL STIFFENER BRACKET ABOVE SEACHEST #20 IN AFT MACHINERY SPACE.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Construction/Loadline
Issued 2 August 1990 Resolved
OPEN FOR INSPECTION AT LEAST TWO MORE SALT WATER BALLAST TANK DISCHARGE VALVES THIS EXAM AND THE BALANCE AT NEXT DRYDOCKING OR UNDERWATER EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Construction/Loadline
Issued 26 June 1990 Resolved
EITHER PROVE #4 PORT DOUBLE BOTTOM WATER TIGHT OR WELD UP PINHOLE LEAK AT 1ST FRAME IN LONGITUDINAL BULKHEAD.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Construction/Loadline
Issued 26 June 1990 Resolved
REPAIR LEAKING PACKING IN BALLAST INTAKE SEAVALVE AT #9 STBD SALTWATER BALLAST TANK.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Construction/Loadline
Issued 26 June 1990 Resolved
PROVIDE COPY OF ULTRASONIC GUAGING REPORT TAKEN DURING INTERNAL EXAMS.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Lifesaving
Issued 1 February 1990 Resolved
CONDUCT HYDROSTATIC TEST OF LIFEBOAT AIR BOTTLES.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 1 February 1990 Resolved
INSERT ALL BOLTS IN PUMPROOM ACCESS HATCH, OR PROVIDE ALTERNATIVE MEANS OF MAKING HATCH FAST.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Electrical
Issued 1 February 1990 Resolved
PROPERLY BLOCK BATTERIES IN AUXILIARY GENERATOR BATTERY BOX.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 1 February 1990 Resolved
REPAIR ALL LEAKING FIRE MONITORS ON MAIN DECK AREA.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 1 February 1990 Resolved
REPAIR AND PROVE PROPER OPERATION OF EMERGENCY DIESEL DRIVEN FIRE PUMP.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Fire Fighting
Issued 1 February 1990 Resolved
PROVIDE PERMANENT STORAGE RACKS FOR ALL NITROGEN BOTTLES.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Lifesaving
Issued 1 February 1990 Resolved
RENEW GASKET ON #1 LIFEBOAT HATCH.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Electrical
Issued 1 February 1990 Resolved
CLEAN OIL FROM AUXILIARY GENERATOR CONTROL ROOM DECK.
Condition: Unknown
Due 1 February 1990
Resolved 1 February 1990
Construction/Loadline
Issued 28 August 1989 Resolved
PROVIDE MARINE SAFETY DETACHMENT SANTA BARBARA WITH A COPY OF THE GAGING REPORT PREPARED FOR EXXON DURING THE AUGUST 1989 TANK INSPECTIONS.
Condition: Unknown
Due 28 August 1989
Resolved 28 August 1989
Construction/Loadline
Issued 30 January 1989 Resolved
REPLACE OR REPAIR 3 DOG LATCHES ON TWO HATCHES TO THE MPDU COMPARTMENT ON SALMS.
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Fire Fighting
Issued 30 January 1989 Resolved
REPLACE TIME DELAYS FOR FIXED HALON SYSTEMS AT T-8 MAIN TRANSFORMER AND DIESEL FIRE PUMP SPACE.
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Deck/Cargo
Issued 30 January 1989 Resolved
PROVIDE EVIDENCE OF CARGO HOSE BEING TESTED TO 1 1/2 TIMES THE MAWP (AT LEAST 225 PSI).
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Deck/Cargo
Issued 30 January 1989 Resolved
CLEAR PUMPROOM BILGES; LOCATE/REPAIR SOURCES OF OIL LEAKS.
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Fire Fighting
Issued 30 January 1989 Resolved
PROVIDE SERVICE REPORT FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Electrical
Issued 23 February 1988 Resolved
LABEL ELECTRICAL PANELS IN GALLEY.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
REPLACE FOUR TEN FOOT FIRE APPLICATORS WITH 4 FOOT APPLICATOR IN MACHINERY SPACES.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Construction/Loadline
Issued 23 February 1988 Resolved
PROVIDE VIDEO TAPE AND UNDERWATER SURVEY REPORT.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
REPAIR LOOSE WIRING FOR SOLENOID CONTROLS TO T-7 TRANSFORMER AND EMERGENCY GENERATOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
SERVICE FOUR OVER PRESSURIZED HALON CYLINDERS.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
SERVICE FOUR UNDERPRESSURIZED HALON CYLINDERS.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
REPAIR SOLENOID SWITCH AT AUX. GENERATOR.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Lifesaving
Issued 23 February 1988 Resolved
REPAIR DAMAGED LIFE RAFT SHELL NUMBER 4 LIFERAFT.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Deck/Cargo
Issued 23 February 1988 Resolved
PROVIDE ANCHOR CHAIN AND PROVE OPERATION OF BRAKE AND WINDLESS.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Accommodation/Occupational Safety
Issued 23 February 1988 Resolved
CLEAN GALLEY EXHAUST DUCT.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
REPAIR LEAK TO FIRE MAIN PIPE AT STATION NUMBER 5.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Lifesaving
Issued 23 February 1988 Resolved
PROVIDE WEAK LINKS FOR LIFE RAFT NUMBER 5 AND 6.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Fire Fighting
Issued 23 February 1988 Resolved
REPAIR OR REPLACE SV15 MAIN SOLENOID SWITCH FOR T-8 HALON SYSTOM.
Condition: Unknown
Due 23 February 1988
Resolved 23 February 1988
Navigation
Issued 30 January 1987 Resolved
REPAIR RELIEF VALVES TO MAIN AIR RECEIVER.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Navigation
Issued 30 January 1987 Resolved
REPAIR RELIEF VALVE TO FIRE WATER JOCKEY TANK.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Fire Fighting
Issued 30 January 1987 Resolved
REPAIR FIRE NOZZLES AND FIRE APPLICATORS THROUGHOUT VESSEL.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Fire Fighting
Issued 30 January 1987 Resolved
RENEW HOLED SECTION OF FIRE PIPE TO NUMBER 3 AUX. FIRE PUMP
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Fire Fighting
Issued 30 January 1987 Resolved
PROVIDE SCHMATIC DRAWINGS FOR ALL HALON SYSTEMS.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Lifesaving
Issued 30 January 1987 Resolved
REPAIR OR RENEW HANGERS FOR RING BUOY LIGHTS AND LINE HOLDERS, VARIOUS LOCATIONS THROUGHOUT VESSEL.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Fire Fighting
Issued 30 January 1987 Resolved
CONDUCT TEST TO HALON SYSTEM TO AUX GENERATOR, STBD TURBINE AND GENERATOR.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Electrical
Issued 30 January 1987 Resolved
CLOSE OPENINGS ON SWITCHBOARD, OUTBOARD OF AUX. GEN., PORT SIDE.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Documentation
Issued 30 January 1987 Resolved
RENEW MARINE DOCUMENT, SHOWING CORRECT OWNER AND ADDRESS.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987
Electrical
Issued 30 January 1987 Resolved
REPAIR OR RENEW WIRE RUN HANGERS IN VARIOUS LOCATIONS ON MAIN DECK AND 01 DECK.
Condition: Unknown
Due 30 January 1987
Resolved 30 January 1987

Ownership record