EXCALIBUR

EXCALIBUR is a 1980 passenger vessel (inspected). The Coast Guard has recorded 84 inspections since 1981, most recently in March 2026, along with 51 deficiencies and 3 casualty investigations between 2006 and 2016.

Records from 1981 to 2026. Most recent: inspection, 13 March 2026.

Built
1980
Last inspected
13 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC9865
Flag
UNITED STATES
367107680
Maury page id
psix-52111

Inspections, by type

…with no type recorded18
Years with a record 43 calendar years (1981–2026)
The 84 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)100.5 ft × 24.6 ft × 3.4 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS LAFITTE INC · LAFITTE, LA, UNITED STATES · built 1980
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC9865MMSI 367107680 · active · compulsorily equipped · granted 11 May 2026, expires 18 April 2036
WCW3529MMSI not assigned · expired · compulsorily equipped · granted 25 March 1996, cancelled 27 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 6

Inspection history · 84

13 March 2026 COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8325810
13 February 2026 Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8310424
17 April 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8113423
25 March 2024 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7884647
20 April 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7672461
4 April 2023 Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7662738
31 March 2022 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7425228
6 April 2021 Type not recorded
No type recorded · Station Galveston · USCG Heartland District (CGD-H) · Activity 7169599
4 March 2021 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7150516
2 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7104895
4 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7060148
9 March 2020 Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6923240
9 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6923400
11 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6660779
5 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6386033
27 March 2018 In-Service Inspection · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6381352
27 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6362344
24 January 2017 Internal Structural Exam · Damage Survey · Annual Inspection · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6076436
28 March 2016 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5845515
25 January 2016 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6012390
3 July 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4366420
5 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4209755
15 September 2011 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4175749
22 December 2010 Drydock Exam · Damage Survey · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3915070
3 March 2010 Drydock Exam · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3689487
9 February 2009 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3414688
7 March 2008 Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3160070
11 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906168
25 May 2006 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2658548
20 May 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2671931
20 April 2006 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2628970
12 July 2005 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2423199
8 July 2004 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2126359
17 June 2004 Annual Inspection · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2103572
13 May 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1792477
24 April 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1778479
6 March 2003 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1753375
8 May 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1614357
19 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068269
8 May 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417275
16 February 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059035
14 September 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365968
28 September 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1045176
16 July 1999 Re-Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444191
4 March 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400932
18 May 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457568
5 May 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125077
21 April 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 14459
7 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 54907
12 June 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113741
27 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402396
27 February 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437207
13 February 1996 COI Inspection · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390208
15 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 181394
2 May 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868670
7 February 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370991
28 April 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 859127
4 February 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370779
5 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451839
1 February 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1370524
17 June 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944558
23 May 1991 Drydock Extension · Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240184
30 January 1991 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925501
28 December 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224556
21 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 995538
16 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931509
23 January 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211252
22 December 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236229
1 June 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045321
18 November 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897582
29 May 1988 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888451
27 April 1988 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040758
19 November 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1002363
9 July 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329699
12 December 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002771
13 November 1985 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986047
13 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991630
7 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977702
10 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972183
1 November 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277220
19 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966279
21 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965550
2 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963676
20 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276879

Deficiency record · 51

04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 March 2024 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. MI observed inadequate dim emergency lighting within the machinery and engine room spaces. Ensure emergency lighting is illuminated sufficiently enough to provide safe means of egress from spaces.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 1 April 2024
Resolution: Vessel representative provided photos showing proper emergency lighting.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2024 Resolved
An interconnected detection and alarm system must Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI observed a cover installed on the galley fire detector preventing the detector from activation. Crew removed the cover and the system was tested sat.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 March 2024
Resolved 25 March 2024
Resolution: Crew corrected deficiency on the spot
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2023 Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Vessel was missing the visual component of the interconnected fire detection system in the machinery spaces. Install visual indicator in machinery spaces to the satisfaction of USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2023
Resolved 4 May 2023
Resolution: vessel rep submitted video evidence of properly installed interconnected fire detection audible and visual in the machinery space and engine room.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 28 March 2016 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape. Install additional emergency lighting in generator room escape hatch.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 5 April 2016
Resolution: Verified e-light was installed and positioned where the emergency exit from the generator room can be properly illuminated during a power loss.
Documentation › Markings/Placards › Warning Signs
Issued 28 March 2016 Resolved
Emergency exits must be marked "EMERGENCY EXIT" and "KEEP CLEAR". Label Escape route in crew accommodation.
Action required: 705 - Other - as specified
Due 27 April 2016
Resolved 5 April 2016
Resolution: "Emergency Exit" signs have been placed in the crew accommodations spaces. All sat.
Documentation › Certificates/Documents › Stability Letter
Issued 28 March 2016 Resolved
Vessel is currently operating with COI ammendment issued back in 2012 reducing pax count inorder to meet the new AAWPP standards. Owner has been directed to contact MSC and submit required doucments for issuance of stability letter addendum.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 11 March 2021
Resolution: Vessel received stability letter addendum 23DEC2016. Addendum is posted on the vessel as required by the regulations.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 3 July 2012 Resolved
Make repairs to emergency light in crew berthing passageway.
Action required: 705 - Other - as specified
Due 17 July 2012
Resolved 7 September 2012
Resolution: Emergency light was tested and functioned correctly.
Engineering › Bilge Water Management System › Interface Detector
Issued 3 July 2012 Resolved
Bilge alarm light at operating station operational but audible alarm is not operable. Make permanent repairs.
Action required: 705 - Other - as specified
Due 17 July 2012
Resolved 7 September 2012
Resolution: All bilge alarms tested and operated properly.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 3 July 2012 Resolved
Provide fixed extinguishing system for paint storage box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 July 2012
Resolved 7 September 2012
Resolution: Fire extinguisher was correctly installed with rubber tube from nozzle penetrating paint locker.
Stability › Incline Test › General
Issued 5 December 2011 Resolved
Vessel’s stability information has not been updated to comply with the new assumed average weight per person of 185 pounds as per 46 CFR 178.310(a)(1). Vessel’s passenger count has been reduced to 43 until certified in compliance with stability regulations.
Action required: 705 - Other - as specified
Resolved 3 July 2012
Resolution: Vessel''s COI amended to reduce passenger count to 43.
Construction/Loadline › Hull › Hull Plating
Issued 22 December 2010 Resolved
Complete repairs to hull plating and associated framing in the lazarette to the satisfaction of the attending CG inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2011
Resolution: Completed satisfactory NDT on all repairs
Lifesaving › Lifebuoys › Approval
Issued 9 February 2009 Resolved
Replace life line on bridge wing buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Construction/Loadline › Structures › Door
Issued 9 February 2009 Resolved
Adjust generator water tight door to make water tight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 9 February 2009 Resolved
Ensure anchor operable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 9 February 2009 Resolved
Porvide flame screen on fuel vents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2009
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2006 Resolved
Vessel damaged in allision with offshore drilling rig. Vessel to crop and renew a 5FT X 48FT section of the hull plating (side shell-port side) along with 4 side longs IWO side shell and 3 vertical supports.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 5 June 2006
Resolution: Vessel replaced side shell, 4 sidelongs and 3 vertical supports.
Construction/Loadline › Hull › Weld
Issued 17 June 2004 Resolved
Cracked welds in peak tank, repair welds.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Construction/Loadline › Hull › Weld
Issued 17 June 2004 Resolved
Cracked weld portside amidships on shear strake stiffener
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Construction/Loadline › Hull › Weld
Issued 17 June 2004 Resolved
Cracked weld located below exhaust vent starboard side engineroom
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Construction/Loadline › Hull › Weld
Issued 17 June 2004 Resolved
Cracked welds, both main deck braces located in aft area of engineroom
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Construction/Loadline › Hull › Weld
Issued 17 June 2004 Resolved
Cracked welds located in various sections of transom inside aft steering compartment
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 June 2004 Resolved
Upper hydraulic hose located against transom worn through to metal sheath. Replace hose
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 17 June 2004 Resolved
Main S/W cooling line to port and starboard MDE's leaking, repair leak
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 17 June 2004 Resolved
Cracked covers on two overhead lights in engineroom, replace covers
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 June 2004 Resolved
Globes on E-lighting dirty, clean globes
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 17 June 2004 Resolved
Bad weak link on BA, replace.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 June 2004 Resolved
Medical supplies in first-aid kit expired, renew expired items
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 June 2004 Resolved
COLREGS out of date, renew publication.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 8 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 8 May 2002 Resolved
Hydro test fire extinguisher in engine room. Service all extinguishers by third party. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2002 Resolved
Repair lazarette bilge alarm; demonstrate proper operation. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Electrical
Issued 8 May 2002 Resolved
Repair or replace all non-working gauges in pilot house control console. Demonstrate proper operation. LEGACY COMPONENT DESC: Guages/pilot house
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 8 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 8 May 2002 Resolved
Label fuel cut outs with directions. LEGACY COMPONENT DESC: Internal Cargo Transfer Capability
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Renew electrical wire penetration seal at aft watertight bulkhead between machinery space and lazarette. LEGACY COMPONENT DESC: Aft bulkhead
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Navigation › Piloting/Steering
Issued 8 May 2002 Resolved
Place cotter pin on starboard side of tie bar/rudder connection pin. LEGACY COMPONENT DESC: Rudderstock
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Navigation › Piloting/Steering
Issued 8 May 2002 Resolved
Tighten bolts on port and starboard side of rudderstock housing. LEGACY COMPONENT DESC: Rudderstock
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Clean out water/debris in forepeak. LEGACY COMPONENT DESC: Forepeak
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Repair 19 fractures in forepeak, as marked. LEGACY COMPONENT DESC: Forepeak
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Clad weld 5 pitts in forepeak. LEGACY COMPONENT DESC: Forepeak
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Eliminate excessive leaking from shaft packing. LEGACY COMPONENT DESC: Shaft packing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Repair 2 fractures underdeck on starboard side of generator room. LEGACY COMPONENT DESC: Generator room
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Fire Fighting › Combustible Materials
Issued 8 May 2002 Resolved
Clean out dryer lint box; reattach dryer vent. LEGACY COMPONENT DESC: Dryer
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Stability › Watertight Integrity
Issued 8 May 2002 Resolved
Readjust watertight door between generator and engine rooms; bottom starboard corner seal not adequate. LEGACY COMPONENT DESC: Watertight door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2002
Resolved 11 June 2002
Engineering
Issued 16 July 1999 Resolved
REPLACE PORT AIR RECEIVER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. _x001C_
Condition: Unknown
Due 16 July 1999
Resolved 16 July 1999
Construction/Loadline
Issued 4 February 1994 Resolved
FREE UP ALL VENT COVERS AND PROVIDE SECURING DEVICES FOR ALL COMPARTMENT VENTS.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Construction/Loadline
Issued 4 February 1994 Resolved
PROVIDE VENT COVERS FOR FOREPEAK, #2 BALLAST TANK VENT, AND PORT FUEL OIL TANK VENT PIPES.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Construction/Loadline
Issued 4 February 1994 Resolved
RENEW FOURTH VENT PIPE ON MAIN DECK AFT OF FORWARD BULKHEAD ON THE STBD SIDE.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Electrical
Issued 28 December 1990 Resolved
PROVE PROPER OPERATION OF GROUND DETECTION METER .
Condition: Unknown
Due 28 December 1990
Resolved 28 December 1990
Documentation
Issued 28 December 1990 Resolved
PROVIDE ON BOARD THE VESSEL A VALID CERTIFICATE OF DOCUMENTATION. REF 46 CFR 67.45-5 AND 67.45-7
Condition: Unknown
Due 28 December 1990
Resolved 28 December 1990
Construction/Loadline
Issued 18 November 1988 Resolved
PAINT DRAFT MARKS IN CONTRASTING COLOR.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Construction/Loadline
Issued 18 November 1988 Resolved
RENEW BOLTED FLUSH HATCH ABOVE PORT MAIN ENGINE DUE TO CRACKS PROPOGATING FROM PREVIOUS REPAIRS.
Condition: Unknown
Due 18 November 1988
Resolved 18 November 1988
Electrical
Issued 1 November 1982 Resolved
REPLACE PORT ENGINE ROOM FORCED AIR MOTOR AND VENT TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 1 November 1982
Resolved 1 November 1982

Casualty record · 3

20 May 2006Routine · role: Involved in a Marine Casualty · activity 2671931
15 October 2012Routine · role: Involved in a Marine Casualty · 1 injured · activity 4465247
25 January 2016Routine · role: Transiting Vicinity of Primary Subject · activity 6012390
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.