MAURY USCG vessel records Sign in
← All vessels

HERCULES 251

HERCULES 251 is a 1978 mobile offshore drilling unit. The Coast Guard has recorded 93 inspections since 1982, most recently in May 2012, along with 155 deficiencies and 4 casualty investigations between 2004 and 2013.

Records from 1982 to 2013. Most recent: casualty investigation, 21 September 2013.

Built
1978
Last inspected
29 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8755522 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-52112

Inspections, by type

…with no type recorded39
Years with a record 29 calendar years (1982–2012)
The 93 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3761 - Regulatory (Subpart C or D), Net Ton
3761 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 93

29 May 2012 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4327043
12 October 2010 COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3868339
12 January 2010 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3661154
16 October 2008 COC-MODU Renew
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3378168
25 September 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3332444
12 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3163017
28 January 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3137617
18 November 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3109460
6 November 2007 COC-MODU Annual
Type not classified · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3094296
25 October 2006 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2804584
1 March 2006 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2594039
15 November 2005 COC-MODU Annual
Type not classified · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2539011
28 October 2004 COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2221785
2 October 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2249739
12 February 2004 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1954164
28 July 2003 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1859437
10 July 2003 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1842412
13 November 2002 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1704424
19 November 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1464436
22 May 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1049421
1 February 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1048081
30 November 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1457720
26 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801612
4 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793588
18 February 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130561
8 February 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127014
14 January 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 50707
1 December 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400884
19 November 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805827
19 October 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801277
6 February 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1113133
4 December 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1467524
14 October 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 13223
27 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 91884
23 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 83300
23 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115411
16 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110762
13 January 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099489
9 January 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406031
9 July 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50255
1 March 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1404082
12 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441029
6 January 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469786
29 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 59820
25 November 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 174823
6 January 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409060
24 June 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 688889
23 June 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 10431
12 February 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141880
13 January 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455029
10 December 1992 COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412462
7 October 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 941224
16 January 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006300
11 January 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141162
26 November 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 942789
10 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214262
24 April 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1232962
9 April 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239587
10 December 1990 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1238600
30 November 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1230436
15 August 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 999922
2 August 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 920183
18 June 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229581
12 December 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211579
20 September 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200918
23 January 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1207307
10 December 1988 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 897878
4 November 1988 COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1204149
19 October 1988 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1198790
29 January 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1016035
13 November 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1331480
22 May 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027391
10 April 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330814
6 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315227
22 January 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1008991
3 December 1986 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022766
29 October 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319924
8 November 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1300304
3 April 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287521
1 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978689
31 January 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286565
2 November 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1284897
26 September 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979016
14 August 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975665
30 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973459
7 December 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279557
27 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277804
16 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968223
2 June 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970251
17 May 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272733
27 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273431
29 March 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968357
19 October 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271456

Deficiency record · 155

Engineering › Pressure Vessel › Shell Plate
Issued 12 October 2010 Resolved
Provide report for 5 year pressure vessel examination.
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 17 November 2010
Resolution: Received UT report for review. Report resulted in the issue of two additional CG-835 requirements under this same activity.
Operations/Management › Drills/Instruction › Fire
Issued 12 October 2010 Resolved
Prove crew proficiency during fire drills to include proper operation/training with new SCBAs, communications, and methodology.
Action required: 705 - Other - as specified
Due 27 October 2010
Resolved 17 November 2010
Resolution: Proved crew proficiency during fire drills to include proper operation/training with new SCBAs, communications, and methodology.
Engineering › Pressure Vessel › Shell Plate
Issued 12 October 2010 Resolved
Provide local OCMI office with a repair/replacement proposal for Cement Tanks 1 & 3, Barite Tanks 1, 2, 3 & 4 and Rig Air Receiver.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Provided local OCMI office with a repair/replacement proposal for Cement Tanks 1 & 3, Barite Tanks 1, 2, 3 & 4 and Rig Air Receiver.
Engineering › Pressure Vessel › Shell Plate
Issued 12 October 2010 Resolved
Provide U1A for HP Rig Air Receivers 1 & 2 and LP Bulk Air Receiver.
Action required: 705 - Other - as specified
Resolved 17 January 2011
Resolution: Rig will change out the Rig Air Receivers 1 & 2 and LP Bulk Air Receiver. They could not locate the U1As.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Crankcase
Issued 12 January 2010 Resolved
Auxilliary engine exhibited major oil leak. Find and repair leak IAW 46 CFR Subchapter F.
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 9 February 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 12 January 2010 Resolved
Burned, exposed wires next to ladder to mud pits. Repair IAW 46 CFR.
Action required: 705 - Other - as specified
Due 10 February 2010
Resolved 9 February 2010
Fire Fighting › Structural - B Class Divisions › Doors
Issued 6 November 2007 Resolved
Replace missing B Class door on crew's TV Room.
Condition: Improper/Lack of Maintenance
Due 20 November 2007
Resolved 9 November 2007
Resolution: Proper door installed
Lifesaving › Lifeboat › Propulsion Starting System
Issued 6 November 2007 Resolved
Properly charge starting accumulators for both lifeboats to provide for adequate starting capacity.
Condition: Improper/Lack of Maintenance
Due 20 November 2007
Resolved 12 December 2007
Stability › Watertight Integrity › General
Issued 6 November 2007 Resolved
Provide report detailing repairs completed on watertight bulkhead MCTs where packing blocks are missing.
Condition: Improper Installation
Due 20 November 2007
Resolved 28 December 2007
Resolution: Received signed verification from OIM.
Lifesaving › Lifebuoys › Size
Issued 6 November 2007 Resolved
Provide proper weighted ring buoys for both quick release ring buoy stations.
Condition: Improper Installation
Due 20 November 2007
Resolved 13 November 2007
Resolution: Received signed verification from OIM that ring buoys were installed.
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 November 2007 Resolved
Repair rig floor eye wash station to provide proper flow.
Condition: Improper/Lack of Maintenance
Due 20 November 2007
Resolved 13 November 2007
Resolution: Received signed verification from OIM that item was completed.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 November 2007 Resolved
Provide accurate, class approved, fire control plan for rig.
Condition: Improper/Lack of Maintenance
Due 6 December 2007
Resolved 12 February 2008
Fire Fighting › Fire Main › Condition
Issued 15 November 2005 Resolved
Make permanent repairs to holed saltwater manifold supplying fire pumps to the satisfaction of Flag/class. Obtain Flag/class approval of temporary repairs to manifold prior to 22NOV05.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 13 February 2006
Resolution: ABS [name withheld] cleared defiency on behalf of flag/class.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 15 November 2005 Resolved
Obtain class approval for temporary fire detection arrangements in modular accomodations (temp quarters).
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 13 February 2006
Resolution: Deficiency cleared to the satisfaction of ABS Surveyor [name withheld] on behalf of flag/class.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 15 November 2005 Resolved
Make permanent repairs to grating support at #2 lifeboat embarkation platform.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 13 February 2006
Resolution: Deficiency cleared to the satisfaction of ABS Surveyor [name withheld] on behalf of flag/class.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 15 November 2005 Resolved
Make permanent repairs to pinched sprinkler pipe on #2 lifeboat.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 28 February 2006
Resolution: CID accepted digital picture of sprinkler pipe repair via email from [name withheld] of February 28, 2006.
Construction/Loadline › Structures › Door
Issued 15 November 2005 Resolved
Demonstrate watertight integrity on galley W/T Door & W/T door #4.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 13 February 2006
Resolution: Deficiency cleared to the satisfaction of ABS Surveyor [name withheld] on behalf of flag/class.
Lifesaving › Lifeboat › Propulsion Engine
Issued 15 November 2005 Resolved
Make permanent repairs to water pump bearing on #1 lifeboat.
Action required: 705 - Other - as specified
Due 22 November 2005
Resolved 13 February 2006
Resolution: Deficiency cleared to the satisfaction of ABS Surveyor [name withheld] on behalf of flag/class.
Construction/Loadline › Structures › Door
Issued 28 October 2004 Resolved
Ensure water tight integrity of WTD on main deck near galley and near A/C handler.
Action required: 705 - Other - as specified
Resolved 15 November 2005
Accommodation/Occupational Safety › Heating › Piping
Issued 28 October 2004 Resolved
Repair corroded pipe on water heater near galley.
Action required: 705 - Other - as specified
Resolved 15 November 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 28 October 2004 Resolved
Repair oil leak coming from exhaust lagging on #1 SSDG.
Action required: 705 - Other - as specified
Resolved 15 November 2005
Electrical › Electric Supply System (service) › Cable
Issued 12 February 2004 Resolved
Install 600V wire with insulation to the satisfaction of flag state.
Action required: 705 - Other - as specified
Resolved 18 June 2004
Resolution: Received copy of ABS report via email from company rep.
Construction/Loadline › Structures › Door
Issued 12 February 2004 Resolved
Renew water tight doors leading to mud pit room to the satisfaction of flag state.
Action required: 705 - Other - as specified
Resolved 18 June 2004
Resolution: Received copy of ABS report via email from company rep.
Construction/Loadline
Issued 19 November 2001 Resolved
CROP AND RENEW BULKHEAD AT MAINDECK AFT OF HOUSE CENTERLINE WHERE HOLED.
Condition: Unknown
Due 26 November 2001
Resolved 26 November 2001
Lifesaving
Issued 19 November 2001 Resolved
PRIOR TO UNIT RETURNING TO OPERATION CONDUCT BOTH FIRE AND BOAT DRILLS WITHFULL CREW, IN THE PRESENCE OF CG MARINE INSPECTOR.
Condition: Unknown
Due 19 November 2002
Resolved 28 May 2003
Accommodation/Occupational Safety
Issued 30 November 1999 Resolved
Replace ventilation duct over switchboard in number 2 engine space.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Construction/Loadline
Issued 30 November 1999 Resolved
Crop and renew corroded steel at the mudpit entranceway on the maindeck.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Electrical
Issued 30 November 1999 Resolved
Repair / replace foghorn battery box.
Condition: Unknown
Due 30 November 1999
Resolved 30 November 1999
Unknown
Issued 1 December 1998 Resolved
PROPERLY INSTALL PACKING FOR CABLE PENETRATION IN BULKHEAD ON THE STARBOARDAFT DRILL FLOOR.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Electrical
Issued 1 December 1998 Resolved
PROPERLY SECURE WASTED CABLE SUPPORTS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Unknown
Issued 1 December 1998 Resolved
CROP AND RENEW AS ORIGINAL WASTED LADDER WELL SUPPORTS (3"X5"X1/4") AT SHAKER HOUSE.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Unknown
Issued 1 December 1998 Resolved
REPAIR WATER PUMP TO NUMBER 4 MAIN ENGINE.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Lifesaving
Issued 1 December 1998 Resolved
CONDUCT 1.1 OPERATIONAL TEST OF BOTH LIFEBOAT RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE LOCAL OCMI.
Condition: Unknown
Due 1 December 1998
Resolved 1 December 1998
Unknown
Issued 4 December 1997 Resolved
Reinstall piping brackets on S/W lines on bulkhead in mud pit room and repair/renew S/W line in mud pit room.
Condition: Unknown
Due 5 January 1998
Resolved 5 January 1998
Documentation
Issued 4 December 1997 Resolved
Demonstrate compliance with all of the requirements applicable to non-self propelled MODUS contained in (1996) 46 CFR 109 Subpart B; specifically the "Emergency training and drills" requirements of 46 CFR 109.213. Drills must be logged IAW CGD8 Guidance on Lifesaving Regulations, enclosure (A).
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Deck/Cargo
Issued 4 December 1997 Resolved
Make repairs to crane cabs, walkways and wiring as indicated in ABS Statement of Fact. Provide copy of ABS report when repairs completed.
Condition: Unknown
Due 4 December 1997
Resolved 4 December 1997
Electrical
Issued 9 January 1997 Resolved
REPAIR REVERSE POWER RELAY AND EMERGENCY RIG SHUTDOWN ON GENERATOR #4 PRIORTO DRILLING OPERATIONS.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Lifesaving
Issued 9 January 1997 Resolved
LABEL LIFEBOATS WITH RIG NAME ON TOP OF BOAT; PROVIDE LIFELINES, RADAR REFLECTORS, SEARCHLIGHTS, AND THERMAL PROTECTIVE AIDS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Lifesaving
Issued 9 January 1997 Resolved
APPLY RETROFLECTIVE TAPE TO RING BUOYS.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Lifesaving
Issued 9 January 1997 Resolved
PROVIDE RECALIBRATION FOR MSA 260.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Electrical
Issued 9 January 1997 Resolved
LABEL DISTRIBUTION PANELS AS NECESSARY THROUGHOUT RIG.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Documentation
Issued 9 January 1997 Resolved
PROVIDE APPROVED EMERGENCY EVACUATION PLAN.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Accommodation/Occupational Safety
Issued 9 January 1997 Resolved
REPAIR SANITARY WATER PUMPS.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Accommodation/Occupational Safety
Issued 9 January 1997 Resolved
REPLACE/RENEW CEILING TILES, BUNKLIGHT COVERS, LIGHT SWITCH COVERS, AND VENT COVERS AS NECESSARY; OIM SIGN STATION BILLS; COMPLETE REMODELING WORK IN HOSPITAL ROOM.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Documentation
Issued 9 January 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 January 1997
Resolved 24 January 1997
Accommodation/Occupational Safety
Issued 9 January 1997 Resolved
PROVIDE 100 PSI SAFETY RELIEF VALVES ON HOT WATER HEATERS.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Lifesaving
Issued 9 January 1997 Resolved
MUD PIT ROOM: MAKE ALL DOORS SELF-CLOSING AND GAS TIGHT; SEAL BULKHEAD CABLE PENETRATIONS; REMOVE BARE CABLE; MOUNT CABLE AND EXPLOSION PROOF JUNCTION BOXES PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Engineering
Issued 9 January 1997 Resolved
REPAIR REMOTE FUEL SHUT-OFF FOR FUEL PUMP #2.
Condition: Unknown
Due 17 January 1997
Resolved 17 January 1997
Fire Fighting
Issued 12 January 1996 Resolved
REPLACE BALL VALVE WITH A STEM VALVE AT FIRE STATION #2.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
INSTALL LOCK DOWN MECHANISM FOR PAINT LOCKER VENT TO PROVIDE AN AIRTIGHT CLOSURE FOR PROPER OPERATION OF FIXED CO2 FIRE SUPPRESION SYSTEM.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Engineering
Issued 12 January 1996 Resolved
INSTALL A 30 BY 30 INCH MESH FLAME SCREEN ON STANBY GENERATOR FUEL OIL DAYTANK VENT.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Construction/Loadline
Issued 12 January 1996 Resolved
CHAULK TEST WATERTIGHT DOOR TO PAINT LOCKER.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
CROP AND RENEW WASTED FIREMAIN COLLARS AT FIRE STATIONS #2 AND #9.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
RESTENCIL FIRE STATION #9.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
SUBMIT TO CLASS SOCIETY FOR APPROVAL MOST REVISED VERSION OF VESSEL'S FIRE CONTROL PLAN.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
REPLACE FOLLOWING LIFE RING BUOYS: FORWARD BUOY AT LIFE CAPSULE #2 AND AFT BUOY AT LIFE CAPSULE #1.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Documentation
Issued 12 January 1996 Resolved
PROVIDE DOCUMENTATION ON MOST RECENT INTERNAL EXAM OF ALL PRESSURE VESSELS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
TROUBLESHOOT LEAKING FIRE NOZZLE #4.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Electrical
Issued 12 January 1996 Resolved
PROVE PROPER OPERATION OF DRILL FLOOR PURGE ALARM TO DISTRIBUTION PANEL (120V).
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
REPLACE MISSING NOZZLE TO EYE WASH STATION ON DRILL FLOOR.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
REPAIR/REPLACE BROKEN HANDLES ON BOTH B-5 SEMI-FIXED DRY CHEMICAL UNITS BY EMD #2.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
PROVIDE APPROPRIATE PANTS FOR BOTH FIREMAN'S OUTFITS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
REPLACE LINE TO WATERLIGHT ON FWD LIFE RING BUOY BY LIFE CAPSULE #1.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
REMOVE EXCESS OIL FROM UNDERNEATH ALL EMD'S.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Documentation
Issued 12 January 1996 Resolved
FAX COPY OF 1996 OFFSHORE INSTALLATION MANAGER LICENSE FOR E.CANNON TO MSO PORT ARTHUR, TEXAS.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
REPAIR FAULTY EXHAUST SYSTEM IN LIFE CAPSULE #2.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 12 January 1996 Resolved
PROVE PROPER OPERATION OF INTERIOR LIGHTING IN LIFE CAPSULE #2.
Condition: Unknown
Due 12 January 1996
Resolved 12 January 1996
Lifesaving
Issued 13 January 1993 Resolved
PROVIDE LINE THROWING GUN AS REQUIRED BY SOLAS 74/83 CHAPTER III, REGULATION 23.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Electrical
Issued 13 January 1993 Resolved
REPAIR EMERGENCY GENERATOR DRIVE ENGINE.
Condition: Unknown
Due 13 January 1993
Resolved 13 January 1993
Deck/Cargo
Issued 10 December 1992 Resolved
PERFORM LOAD TEST PORT & STARBOARD CRANES.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Lifesaving
Issued 10 December 1992 Resolved
PROVIDE BREATHING AIR FOR # 1 LIFEBOAT.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Documentation
Issued 10 December 1992 Resolved
PROVIDE USCG APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Electrical
Issued 10 December 1992 Resolved
REPAIR OVERSPEED TRIP ON EMERGENCY GENERATOR.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Accommodation/Occupational Safety
Issued 10 December 1992 Resolved
REPLACE SAFETY RELEIF VALVES ON AIR RECEIVERS, CEMENT TANKS & BARITE TANKS WITH ASME APPROVED VALVES.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Electrical
Issued 10 December 1992 Resolved
PROVIDE SAFETY LINES FOR EXPLOSION PROOF NEON LIGHTS IN CLASSIFIED AREAS.
Condition: Unknown
Due 10 December 1992
Resolved 10 December 1992
Lifesaving
Issued 26 November 1991 Resolved
MAKE GENERAL ALARM IN ENGINE/MUD PUMP ROOM ABLE TO BE HEARD OR SEEN (LIGHT)FROM ALL LOCATIONS WITHIN.
Condition: Unknown
Due 17 January 1992
Resolved 17 January 1992
Accommodation/Occupational Safety
Issued 26 November 1991 Resolved
INSTALL SCHRAEDER VALVES ON POTABLE WATER AND SANITARY WATER SURGE TANKS.
Condition: Unknown
Due 17 January 1992
Resolved 17 January 1992
Deck/Cargo
Issued 26 November 1991 Resolved
REPAIR OR RENEW ALL THREE CEMENT TANK RELIEF VALVES.
Condition: Unknown
Due 17 January 1992
Resolved 17 January 1992
Electrical
Issued 26 November 1991 Resolved
REPACK EXPLOSION PROOF FITTING FOR LIGHT OVER #2 MUDPIT AFT.
Condition: Unknown
Due 17 January 1992
Resolved 17 January 1992
Electrical
Issued 26 November 1991 Resolved
REMOVE IMPROPER INCADESCENT LIGHT FROM MUD PIT AREA BY WATERTIGHT DOOR 22
Condition: Unknown
Due 17 January 1992
Resolved 17 January 1992
Electrical
Issued 26 November 1991 Resolved
REPAIR OVERSPEED TRIP ON STAND-BY GENERATOR TO COMPLETELY SHUTDOWN ENGINE.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Unknown
Issued 24 April 1991 Resolved
SUBMIT ABS REPORT, DIVER'S REPORT, AND VIDEO TAPE OF UNDERWATER PORTION OF SPECIAL EXAMINATION IN LIEU OF DRYDOCK CONDUCTED 24 APR 91 TO MSO PORT ARTHUR.
Condition: Unknown
Due 24 April 1991
Resolved 24 April 1991
Unknown
Issued 10 December 1990 Resolved
CONDUCT EXTERNAL EXAMINATION OF MAT; TOP, SIDES AND BOTTOM IN THE PRESENCE OF A MARINE INSPECTOR. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] VERMILION BLOCK 158 BUT NLT 29MAR91.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Unknown
Issued 10 December 1990 Resolved
MAKE AVAILABLE FOR INSPECTION ALL MUD PIT DUMP VALVES. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] VERMILION BLOCK 158 BUT NLT 29MAR91.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Unknown
Issued 10 December 1990 Resolved
OPEN ALL AIR RECEIVERS FOR INTERNAL INSPECTION AND TEST RELIEF VALVES ON SAME.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Unknown
Issued 10 December 1990 Resolved
TEST ALL REMOTE SHUTDOWNS FOR ALL FOUR MAIN GENRATORS AND REVERSE CURRENT RELAYS FOR SAME.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING REMOVE THE DOUBLE WIRE FROM THE SINGLE EYS FITTING ON THE JUCTION BOX ON THE KUME UNIT.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Lifesaving
Issued 12 December 1989 Resolved
STENCIL NAME OF RIG, HOME PORT ON BOTH CAPSULES.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Lifesaving
Issued 12 December 1989 Resolved
RECHARGE BATTERYS IN BOTH CAPSULES
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Lifesaving
Issued 12 December 1989 Resolved
RECHANGE AIR BOTTLES IN THE #1 CAPSULE. ALL BOTTLES 1600 PSI.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING CORRECT PURGE ALARM (LIGHT) ON THE HEITMAN MUD MONITOR SYSTEM ON THE DRILL FLOOR. PURGE AIR SUPPLY MUST BE SEPERATE FROM THATS NEEDED TO OPERATE THE UNIT. THE OTHER HEITMAN MONITOR SHOULD ALSO BE CHECKED FOR COMPLIANCE TO NFPA 496 (LEFT ON RIG)
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Deck/Cargo
Issued 12 December 1989 Resolved
CONDUCT A ANNUAL CRANE INSPECTION IAW RP2D BY A RECOGNIZED AGENCY.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING REMOVE OIL FROM PURGE POWER PANELS.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING INSTALL AUDIBLE ALARM FOR PURGE SYSTEMS ON AFT WIND WALL.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Documentation
Issued 12 December 1989 Resolved
CONDUCT A ANNUAL LOAD LINE TEST INSPECTION.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING POUR EYS FITTING TO SWITCH ON THE DESANDER UNIT OUT BOARD THE SHAKER AREA.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Construction/Loadline
Issued 12 December 1989 Resolved
REPLACE THE STEEL DECKING BELOW THE DESANDER UNIT OUT BOARD THE SHAKER HOUSE.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
INSTALL OIL SEPERATOR FILTER FOR PURGE AIR SUPPLY ON DRILL FLOOR.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Unknown
Issued 12 December 1989 Resolved
INTERNATIONAL DIVING CONSULTANTS, PROVIDE NAME PLATE DATA FOR THE #2 PVHO ON BOARD.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
CONDUCT THE LOAD TEST ON THE GENERAL ALARM BOTTLES AND EMERGENCY GENERATOR REQUIRED BY 46CFR 109.211 TO BE SUBMITTED WITH RESPONCE LETTER.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Electrical
Issued 12 December 1989 Resolved
PRIOR TO DRILLING REPLACED THE WASTED EYS FITTINGS IN THE MUD PIT. THOSE WHICH ARE LOCATED ON THE JUCTION BOXES DO NOT NECESSARLY NEED EYS FITTINGS.FITTINGS SATISFACTORY FOR CLASS I DIV II AREAS WILL BE SATISFACTORY.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Construction/Loadline
Issued 4 November 1988 Resolved
REPLACE WASTED SKIRT ON THE WATERTIGHT HATCH IN MUD PITS (STARBOARD SIDE).
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988 Resolved
PROVIDE ELECTRICAL LOAD ANALYSIS FOR GENERAL ALARM SYSTEM WITH PROPOSED REDESIGN TO ENSURE THAT THE FIRE DOOR ACTIVATION RELAY IS NOT INSTALLED ON AN EXISTING BRANCH CIRCUIT.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Deck/Cargo
Issued 4 November 1988 Resolved
PROVIDE ASME APPROVED RELIEF VALVES FOR ALL AIR RECEIVERS.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 4 November 1988 Resolved
PROVIDE NON-SKID SURFACE FOR THE HELO DECK.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Lifesaving
Issued 4 November 1988 Resolved
HYDRO ALL AIR BOTTLES IN BOTH BOATS.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988 Resolved
REPLACE PACKING GLAND ON THE NUMBER 2 BILGE PUMP.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988 Resolved
RENEW BILGE PUMP SUCTION AND DISCHARGE VALVE HANDLES.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Fire Fighting
Issued 4 November 1988 Resolved
RENEW OR REBUILD THE NUMBER 2 BOOSTER FIRE PUMP (CURRENTLY PRODUCING 60 PSI).
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988 Resolved
PROVIDE VISUAL OR AUDIBLE ALARMS FOR ALL PURGE SYSTEMS ON NON-EXPLOSION PROOF JUNCTION BOXES ON DRILL FLOOR. CURRENT LOGGING EVERY 30 MINS OF PURGE SYSTEM INSTITUTED WHILE IN OPEN HOLE UNTIL REPAIRS EFFECTED.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Documentation
Issued 4 November 1988 Resolved
UPDATE/RESUBMIT HAZARDOUS LOCATION PLAN IAW 46 CFR 109.121.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Lifesaving
Issued 4 November 1988 Resolved
PROVIDE FIRST AID KIT IN ACCORDANCE WITH 46 CFR 108.707.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Electrical
Issued 4 November 1988 Resolved
PROVIDE VISUAL OR AUDIBLE PURGE ALARM SYSTEM FOR ADAIR MUD LOGGING AND GAS DETECTION UNITS. ENSURE ALL WARNING AUDIBLE DEVICES ARE EXPLOSION PROOF. COMPLY BY: 11NOV88
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 19 October 1988 Resolved
CONDUCT UNDERWATER VISUAL SURVEY OF TOP, BOTTOM AND SIDE SHELL PLATTING OF LOWER MATT.
Condition: Unknown
Due 19 October 1988
Resolved 19 October 1988
Fire Fighting
Issued 13 November 1987 Resolved
RENEW WASTED PORTIONS OF PAINT LOCKER BULKHEADS AND DECK.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Construction/Loadline
Issued 13 November 1987 Resolved
REPAIR WATERTIGHT DOOR AT STARBOARD SIDE OF MUDPIT ROOM.
Condition: Unknown
Due 13 November 1987
Resolved 13 November 1987
Unknown
Issued 3 December 1986 Resolved
REPAINT THE ILLEGIBLE LOADLINE AND HULL MARKINGS.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Unknown
Issued 3 December 1986 Resolved
CONDUCT AN UNDERWATER SURVEY OF THE MAT TOP, SIDES, BOTTOM, MOON POOL, AND KEYWAY.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Unknown
Issued 3 December 1986 Resolved
PROVIDE A COPY OF THE ABS REPORT OF UNDERWATER SURVEY CONDUCTED 2 DECEMBER 1986.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Accommodation/Occupational Safety
Issued 3 December 1986 Resolved
HYDRO TEST AIR RECEIVER PIPING IN WAY OF NEW RELIEF VALVE INSTALLATION TO 1.5 MAWP IN THE PRESENCE OF A MARINE INSPECTOR. PROVIDE DOCUMENTATION OF THE WELDERS CERTIFICATION AND A COPY OF THE APPROVED PROCEDURE.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Construction/Loadline
Issued 3 December 1986 Resolved
PROVIDE A COPY OF THE DIVING CONTRACTOR'S REPORT OF UNDERWATER SURVEY CONDUCTED 2 DECEMBER 1986.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Unknown
Issued 3 December 1986 Resolved
CROP AND RENEW TWO SMALL SECTIONS OF WASTED WALKWAY DECKING NEAR SHALESHAKER.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Unknown
Issued 3 December 1986 Resolved
REMOVE VIDEO CAMERA FROM VICINITY OF SHALESHAKER AREA OR INSTALL ACCEPTABLEAIR PURGE SYSTEM WITH ALARM OR PROVIDE EVIDENCE THAT EQUIPMENT IS CLASSIFIED FOR THE HAZARDOUS LOCATIONS.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Construction/Loadline
Issued 29 October 1986 Resolved
REPAIR THE INOPERATIVE #2 BILGE AND BALLAST PUMP.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 29 October 1986 Resolved
CONDUCT A TEST OF THE REVERSE POWER RELAYS FOR THE FOUR SERVICE GENERATORS AND ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 29 October 1986 Resolved
REPAIR AND TEST THE OVER-SPEED TRIP ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 29 October 1986 Resolved
TEST THE EMERGENCY LIGHTING SYSTEM.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Construction/Loadline
Issued 29 October 1986 Resolved
COMPLETE A CREDIT DRYDOCK OR UNDERWATER SURVEY IN LIEU OF DRYDOCK UPON THE NEXT RIG MOVE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Accommodation/Occupational Safety
Issued 29 October 1986 Resolved
CONDUCT A PRESSURE TEST OF ALL THE AIR RECEIVER AND P-TANK RELIEF VALVES.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Accommodation/Occupational Safety
Issued 29 October 1986 Resolved
INSTALL RELIEF VALVES ON THE THREE SHIP'S SERVICE AIR RECEIVERS IN THE PORTAFT COMPRESSOR ROOM.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986 Resolved
PROVIDE THE #1 LIFEBOAT WITH 2 PAINTERS, RENEW THE EXHAUST LINE DRAIN VALVEAND CONDUCT THE ANNUAL FUEL CHANGE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986 Resolved
PROVIDE THE #2 LIFEBOAT WITH 2 PAINTERS, RENEW THE EXHAUST LINE DRAIN VALVEAND CONDUCT THE ANNUAL FUEL CHANGE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986 Resolved
IN THE PRESENCE OF A MARINE INSPECTOR CONDUCT FIRE AND ABANDON VESSEL DRILLS INCLUDING OPERATION OF LIFEBOATS IN THE WATER.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Accommodation/Occupational Safety
Issued 29 October 1986 Resolved
MAKE ALL AIR RECEIVERS AND P-TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Accommodation/Occupational Safety
Issued 29 October 1986 Resolved
TEST THE FUEL TRANSFER, VENTILATION, AND RIG POWER SHUTDOWNS.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Unknown
Issued 29 October 1986 Resolved
REPAIR THE DRILLER'S CONSOLE PURGE AIR ALARM AND REMOVE THE IMPROPERLY INSTALLED LIGHT BULB FROM THE DRILLER'S CONSOLE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 29 October 1986 Resolved
PROVIDE EYS POURED FITTINGS FOR THE NEW LIGHTING WIRING CONNECTIONS IN THE SHALE SHAKER SPACE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 29 October 1986 Resolved
PROVIDE DOCUMENTATION THAT THE CLOSED CIRCUIT CAMERAS IN THE SHALE SHAKER AND DRILL FLOOR ARE SAFE FOR CLASS I, DIVISION II LOCATIONS OR PROVIDE THEMWITH AIR PURGE OR REMOVE THEM.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Deck/Cargo
Issued 29 October 1986 Resolved
HAVE THE ANNUAL CRANE LOAD TESTS CONDUCTED BY AN AUTHORIZED AGENCY.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Fire Fighting
Issued 29 October 1986 Resolved
CONDUCT ANNUAL SERVICING OF ALL FIXED AND PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Fire Fighting
Issued 29 October 1986 Resolved
INSTALL A CLOSURE DEVICE FOR THE LOWER LEVEL STAIRWAY VENTILATION GRILL SO THAT THE STAIRWAY CAN BE EFFECTIVELY CLOSED OFF IN THE EVENT OF FIRE.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Lifesaving
Issued 29 October 1986 Resolved
REPLACE THE THREE DAMAGED RING BUOYS.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Fire Fighting
Issued 8 November 1985 Resolved
REPLACE OXYGEN SENSOR IN O2/EXPLOSIVE METER FOR FIREMAN OUTFIT IN RECREATION ROOM.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Lifesaving
Issued 8 November 1985 Resolved
REPLACE 107 DEFECTIVE WATER CANS IN PORT CAPSULE WITH SERVICEABLE UNITS.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Lifesaving
Issued 8 November 1985 Resolved
RESERVICE ONE (1) AIR BOTTLE IN EACH CAPSULE.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Navigation
Issued 8 November 1985 Resolved
INSTALL PROPER LAMPS IN PORT/STARBOARD AND STERN RUNNING LIGHTS.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Lifesaving
Issued 8 November 1985 Resolved
INSTALL SPACER BAR ON EACH OF 2 SMOKE FLOAT SIGNALS NEAR CAPSULES.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Electrical
Issued 8 November 1985 Resolved
REPAIR OR REPLACE PURGE WARNING LIGHT FOR DRILLERS CONSOLE.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Electrical
Issued 8 November 1985 Resolved
REPLACE FRAYED CABLES RUNNING FROM BOTH SHALE SHAKER MOTORS AND START/STOP STATIONS.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Electrical
Issued 8 November 1985 Resolved
REPLACE SEAL BEAM TO EMERGENCY LIGHT BOX IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Electrical
Issued 1 March 1985 Resolved
MAKE REPAIRS TO THE SPEED CONTROL SWITCH ON THE MAIN SWITCHBOARD FOR THE #3AC GENERATOR AND TEST TO THE SATISFACTION OF A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Lifesaving
Issued 1 March 1985 Resolved
MAKE REPAIRS OR REPLACE ALL LIFE JACKETS THAT HAVE RETRO-REFLECTIVE TAPE FALLING OFF.
Condition: Unknown
Due 1 March 1985
Resolved 1 March 1985
Lifesaving
Issued 2 November 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 November 1984
Resolved 2 November 1984
Construction/Loadline
Issued 14 August 1984 Resolved
COMPLETE UNDERWATER EXAMINATION AT THE TIME OF THE NEXT RIG MOVE. ALSO MAKE ALL TANKS IN UPPER HULL (EXCEPT FUEL TANKS) AVAILABLE FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 14 August 1984
Resolved 14 August 1984
Lifesaving
Issued 7 December 1983 Resolved
HAVE AIR BOTTLES IN BOTH LIFE SAVING CAPSULES HYDRO TESTED AND FILLED. TOTAL TWELVE (12) BOTTLES.
Condition: Unknown
Due 7 December 1983
Resolved 7 December 1983

Casualty record · 4

2 October 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2249739
18 November 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3109460
28 January 2008Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3137617
21 September 2013Routine · role: Acknowledged Pollution Source · activity 4723383
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

THE 251 (2004–2008). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.