Records from 1981 to 1999. Most recent: inspection, 6 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
6 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778066
5 June 1998
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453488
16 June 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1422869
21 June 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461723
27 February 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886157
27 June 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1442274
8 July 1994
Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450865
29 June 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1174582
29 June 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1420888
14 November 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 42760
1 July 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 846643
6 July 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471288
11 July 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1004840
31 July 1990
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1236346
1 May 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237788
15 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1340558
16 March 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350841
16 August 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038339
17 August 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1002936
2 June 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1339144
16 September 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311105
9 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997929
14 March 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1300085
21 November 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 993447
14 November 1985
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 994989
19 September 1985
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990970
11 April 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 978382
14 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286277
12 October 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976744
6 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966691
1 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278234
7 October 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277570
4 May 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274498
8 October 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967162
Documentation
Issued 21 June 1996
Resolved
PROVIDE ON BOARD CERTIFICATE OF DOCUMENTATION TO REFLECT NAME CHANGE TO SEABULK JASPER.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Navigation
Issued 29 June 1994
Resolved
RENEW AS ORIGINAL AND DETERMINE CAUSE OF WEAR TO PORTSIDE RUDDER POST SHELFAT NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Construction/Loadline
Issued 29 June 1994
Resolved
RENEW AS ORIGINAL PORT/STBD STERN WRAPPER, BRACKETS AND STIFFNERS AS NEEDEDDURING SCHEDULED DRYDOCK.
Condition: Unknown
Due 2 August 1994
Resolved 2 August 1994
Deck/Cargo
Issued 14 November 1985
Resolved
PROVIDE A NEW ANCHOR FOR THE VESSEL PRIOR TO 19 NOVEMBER 1985.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Construction/Loadline
Issued 14 November 1985
Resolved
MAKE PERMANENT REPAIRS TO THE SIX (6) INCH HOLE ON THE STARBOARD SIDE OF THE STEM OF THE FOREPEAK TANK PRIOR TO 19 NOVEMBER 1985.
Condition: Unknown
Due 14 November 1985
Resolved 14 November 1985
Electrical
Issued 12 October 1984
Resolved
PERMANENTLY SECURE THE BATTERY FOR THE GENERATOR LOCATED ON THE STARBOARD SIDE AFT IN THE ENGINE ROOM.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Navigation
Issued 12 October 1984
Resolved
OBTAIN A COPY OF THE NEW U. S. COAST GUARD NAVIGATION RULES.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Unknown
Issued 12 October 1984
Resolved
PERMANENTLY SECURE CLOSURE PLUGS FOR ALL GOOSENECK VENTS ON DECK.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Accommodation/Occupational Safety
Issued 12 October 1984
Resolved
PERMANENTLY MOUNT THE PUMP FOR THE SHOWER DRAIN LOCATED UNDER THE DECK OF THE PASSENGER AREA.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Unknown
Issued 12 October 1984
Resolved
PROVIDE PERMANENT IDENTIFICATION LABELS ON ALL BREAKERS IN BOXES LOCATED ONTHE PORT SIDE OF THE PILOT HOUSE.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Electrical
Issued 12 October 1984
Resolved
PROVIDE A NEW AMP METER FOR THE GENERATOR BATTERY RECHARGER.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984
Unknown
Issued 12 October 1984
Resolved
TEST THE EMERGENCY STOP FOR THE AFTER PORT ENGINE ROOM BLOWER UPON REIN- STALLATION OF THE BLOWER.
Condition: Unknown
Due 12 October 1984
Resolved 12 October 1984