Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 3 October 2019
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8754281
Flag
MARSHALL ISLANDS
Maury page id
psix-52123

Documentation record

Tonnage as PSIX records it6157 - Convention (Subpart B), Gross Ton
1847 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 7

3 October 2019 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6830075
15 June 2018 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6507264
24 July 2017 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6310323
18 April 2017 Deficiency Check · COC-MODU Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6099649
23 May 2016 Administrative Inspection · Deficiency Check · COC-MODU Renew
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5885770
12 April 2016 In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6025105
6 January 2016 Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5852571

Deficiency record · 40

Documentation › Logs/Records › Oil Record Book
Issued 18 April 2017 Resolved
1710 - Oil record book - ORB shall be completed on each occasion when disposing of oil. Rig had numerous ORB entries of disposal ashore, but no receipts. (MARPOL 73/78 Annex I/17) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating oily wastes retained & disposed ashore. Ensured ABS knew to check for receipts per MARPOL Annex I/Appendix III.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2017 Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock, fire, & explosion hazards…Dead-ended wire to right of camera box & temporary electrical cord run w/ other wires/cables in driller shack. (MI-293 Standard Part V.E.) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating temporary & dead-ended wires removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 April 2017 Resolved
0999 - Other (Safety in General) - Loss of ventilation is alarmed at manned station. Loss of ventilation alarm does not actuate when mud pit room doors are opened. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating alarm working as designed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 April 2017 Resolved
0999 - Other(Safety in General)-Equipment should be certified as suitable for the flammable gas/air mixture which may be encountered. Purge alarms for camera panel & accumulator panel inoperative in driller shack. (79 MODU Code/6.6) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating purge alarms operative.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2017 Resolved
0925 - Musters and drills - Emergency Evacuation drills must be conducted yearly & monthly. No records exercising EEP available. (33 CFR 146.125) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 April 2017
Resolution: Rcvd email records for EEP fire & volcanic eruption drills fm OIM.
Stability › Intact Stability (when using lifting gear) › General
Issued 18 April 2017 Resolved
0999 - Other (Safety in General) - 3rd party Feb/March 2017 crane reports indicate a number of “needs attention.” ABS report of 07Apr2017 does not rectify 3rd party notes/comments or reference them. (33 CFR 143.207, 46 CFR109.301) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 30 June 2017
Resolution: Rcvd ABS email/rpt indicating cranes repaired.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 April 2017 Resolved
0799 - Other (Fire fighting equipment) - Doors should be “A.” Both fire screen doors (FSD) btwn E/R & SCR room wasted at bottom & holes covered w/ tape. FSD & door jamb at 1st deck stairwell have holes. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating holes repaired using steel sheet.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 April 2017 Resolved
0715 - Detection - Appliances should be kept in good order & available for immediate use….Heat detector above #1 MDG hanging by wires, heat detector above #3 MDG ziptied, & center heat detector in mud pump room taped in place. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating detectors securely mounted & tested.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 April 2017 Resolved
1499 - Other(Prop. & Aux. Machinery)-Machinery must be maintained & operated in a safe manner at all times. E-gen exhaust piping leaking w/in e-gen room. (MI-293 Standard Part V.D.) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating no exhaust leaks noted.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017 Resolved
0999 - Other (Safety in General) - Each helicopter deck should be fitted with lights around perimeter not more than 3 metres apart. One light extinguished & another flashing. (79 MODU Code/13.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating lights tested w/ none extinguished.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 April 2017 Resolved
0999 - Other(Safety in General)-Electrical equipment to be constructed to minimize electrical shock….Panel MCC SCR Aux NN2 missing bulb & cover. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Bulb & cover fitted prior to CG departure.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2017 Resolved
0799 - Other(Fire fighting equipment)-Fire-extinguishing appliances should be available for immediate use….Electrician shop fixed fire extinguishing system controls & instructions blocked. (79 MODU Code/9.13) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Controls & instructions unblocked prior to CG departure.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2017 Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock….Speaker at 5th level, top deck loose. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Speaker secured prior to CG departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 May 2016 Resolved
1799 - Other (MARPOL Annex 1) - Crew was unable to operationally test the oily water seperator (pump not working, already ordered. Oily waste pumpted to portable tanks & transported to shore). (73/78 MARPOL Annex I/14.6) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class issued new IOPP Cert w/ Form A requiring disposal of oil residues to reception facilities ashore.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 May 2016 Resolved
0610 - Life saving appliance (lifeboats) - Crew unable to operationally test #2 lifeboat (fuel pump not working, already ordered). (79 MODU Code/10.1) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Lifeboat removed fm svc. Class issued MODU Document of Compliance reducing total number of persons authorized.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 May 2016 Resolved
1499 - Propulsion & aux. Machinery (other) - Emergency generator cooling water hoses cracked & weeping & epoxy repair on jacket water sending unit housing. Make proper repair/replacement. (79 MODU Code/4.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class witnessed repairs to generator cooling hoses & thermostat housing gaskets.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 May 2016 Resolved
0610 - Life saving appliance (lifeboats) - Air supply system to all lifeboats leaking once energized, missing dogs to several windows, portable fire extinguishers not mounted, missing retroreflective material to external bottom hull, engine cover screws missing, & missing oar lock cover(s). Annual servicing suspect. Annual service required for all lifeboats. (79 MODU Code/10.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class examined repairs to #1 & #2 (ex #3) lifeboats. See attached ABS rpt HOM3147506 dtd 03Jun2016.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 May 2016 Resolved
0799 - Fire fighting appliances (other) - Provide updated fire safety appliance servicing report. (79 MODU Code/9) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached ABS class rpt HOM3147506 dtd 03Jun2016 details repairs/replacement of fire safety appliances aboard rig.
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 May 2016 Resolved
0610 - Life saving appliance (lifeboats) - Cutout modification to #1 & #3 lifeboat releasing gear support structure suspect. Provide class report indicating modification satisfactory &/or in accordance with manufacturer recommendation(s). (79 MODU Code/10.5) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating spacer over suspension bolt to retain spacing. Satisfactory according to manufacturer & Class.
Construction/Loadline › Structures › Door
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Doors to mudpit room not self-closing or gas-tight. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 details repairs to mudpit room doors.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 23 May 2016 Resolved
0610 - Life saving appliance (lifeboats) - Provide class report indicating PVC pipe used in all lifeboat sprinkler systems approved &/or in accordance with manufactuerer recommendation(s). (79 MODU Code/10.1) 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating PVC approved & in original construction. Satisfactory according to manufacturer & Class.
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2016 Resolved
1499 - Propulsion & aux. Machinery (other) - Fire hazard identified in minor fuel leaking from flame impingement bowl fittings of MDGs. (79 MODU Code/4.1) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating metallic fuel filters installed & sat.
Lifesaving › Lifebuoys › Approval
Issued 23 May 2016 Resolved
0650 - Fire fighting appliances (lifebuoys) - Fit lifebuoys with retroreflective material. (79 MODU Code/10.4) 50a
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 22Jun2016 indicating reflective tape applied to lifebuoys.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Remove temporary electrical cord from overhead in crew mess. (79 MODU Code/5) 50a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating temp elec cord removed.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #24. Cleared.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Each crane should be examined annually & verified by the Administration. (79 MODU Code/12.1.5) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Class completed annual exam & provided statement of fact HOM3147506 dtd 03Jun2016.
Construction/Loadline › Structures › Door
Issued 23 May 2016 Resolved
0799 - Fire fighting appliances (other) - Fire screen doors missing or have inoperative latches, throws, or self closing devices throughout rig. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 May 2016 Resolved
1270 - Load lines (doors) - Bottom lip of water tight door #27 wasted. Repair or replace. (ICLL Annex I/12) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating bottom lip of door cropped/renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Repair torn helicopter deck safety net as necessary. (79 MODU Code/13.3) 50ac
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating torn helo safety net repaired.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 23 May 2016 Resolved
0699 - Life saving appliance (other) - Bow & stbd leg means of embarkation (ladders from deck to surface of water) wasted, missing rungs, bent, &/or covered in barnacles. Repair/clean. (79 MODU Code/10.11) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Rcvd copy of RMI MODU Document of Compliance indicating scramble nets in lieu of fixed ladders authorized.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 May 2016 Resolved
0799 - Fire fighting appliances (other) - Provide proper portable fire extinguisher brackets throughout rig. (79 MODU Code/9.6) 50ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 indicates extinguishers were mounted w/ proper brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Repair lights throughout machinery spaces. (79 MODU Code/4.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating machinery space lights illuminated & sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 May 2016 Resolved
0715 - Fire fighting appliances (detection) - Heat detector above #2 MDG zip tied. Permanently install. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector perm installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016 Resolved
0740 - Fire fighting appliances (pumps) - J box cover missing at fire pump space. Install. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - Loud speaker loose, J box cover missing, & J box loose near flag mast, & loose cable near fast rescue boat. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - 3 H2S panel sensors in fault mode. Repair. (79 MODU Code/5.1) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating Gen II H2S & LEL detection sys installed/op tested sat.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #12. Rcvd emailed ABS survey rpt dtd 28May2016 indicating overall tank survey complete Feb 2016.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - E-light @ E-gen inoperative. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - 5 year crane load test records not available. Records found. (79 MODU Code/12.1.5) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Records found prior to our departure.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 23 May 2016 Resolved
0999 - Safety in general (other) - E-gen distribution panel missing indicator lights, indicator light covers, & breaker actuators. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.