Documentation › Logs/Records › Oil Record Book
Issued 18 April 2017
Resolved
1710 - Oil record book - ORB shall be completed on each occasion when disposing of oil. Rig had numerous ORB entries of disposal ashore, but no receipts. (MARPOL 73/78 Annex I/17) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating oily wastes retained & disposed ashore. Ensured ABS knew to check for receipts per MARPOL Annex I/Appendix III.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock, fire, & explosion hazards…Dead-ended wire to right of camera box & temporary electrical cord run w/ other wires/cables in driller shack. (MI-293 Standard Part V.E.) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating temporary & dead-ended wires removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Loss of ventilation is alarmed at manned station. Loss of ventilation alarm does not actuate when mud pit room doors are opened. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating alarm working as designed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 April 2017
Resolved
0999 - Other(Safety in General)-Equipment should be certified as suitable for the flammable gas/air mixture which may be encountered. Purge alarms for camera panel & accumulator panel inoperative in driller shack. (79 MODU Code/6.6) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating purge alarms operative.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2017
Resolved
0925 - Musters and drills - Emergency Evacuation drills must be conducted yearly & monthly. No records exercising EEP available. (33 CFR 146.125) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 April 2017
Resolution: Rcvd email records for EEP fire & volcanic eruption drills fm OIM.
Stability › Intact Stability (when using lifting gear) › General
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - 3rd party Feb/March 2017 crane reports indicate a number of “needs attention.” ABS report of 07Apr2017 does not rectify 3rd party notes/comments or reference them. (33 CFR 143.207, 46 CFR109.301) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 30 June 2017
Resolution: Rcvd ABS email/rpt indicating cranes repaired.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 April 2017
Resolved
0799 - Other (Fire fighting equipment) - Doors should be “A.” Both fire screen doors (FSD) btwn E/R & SCR room wasted at bottom & holes covered w/ tape. FSD & door jamb at 1st deck stairwell have holes. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating holes repaired using steel sheet.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 April 2017
Resolved
0715 - Detection - Appliances should be kept in good order & available for immediate use….Heat detector above #1 MDG hanging by wires, heat detector above #3 MDG ziptied, & center heat detector in mud pump room taped in place. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating detectors securely mounted & tested.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 April 2017
Resolved
1499 - Other(Prop. & Aux. Machinery)-Machinery must be maintained & operated in a safe manner at all times. E-gen exhaust piping leaking w/in e-gen room. (MI-293 Standard Part V.D.) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating no exhaust leaks noted.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Each helicopter deck should be fitted with lights around perimeter not more than 3 metres apart. One light extinguished & another flashing. (79 MODU Code/13.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating lights tested w/ none extinguished.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 April 2017
Resolved
0999 - Other(Safety in General)-Electrical equipment to be constructed to minimize electrical shock….Panel MCC SCR Aux NN2 missing bulb & cover. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Bulb & cover fitted prior to CG departure.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2017
Resolved
0799 - Other(Fire fighting equipment)-Fire-extinguishing appliances should be available for immediate use….Electrician shop fixed fire extinguishing system controls & instructions blocked. (79 MODU Code/9.13) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Controls & instructions unblocked prior to CG departure.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock….Speaker at 5th level, top deck loose. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Speaker secured prior to CG departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 May 2016
Resolved
1799 - Other (MARPOL Annex 1) - Crew was unable to operationally test the oily water seperator (pump not working, already ordered. Oily waste pumpted to portable tanks & transported to shore). (73/78 MARPOL Annex I/14.6) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class issued new IOPP Cert w/ Form A requiring disposal of oil residues to reception facilities ashore.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Crew unable to operationally test #2 lifeboat (fuel pump not working, already ordered). (79 MODU Code/10.1) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Lifeboat removed fm svc. Class issued MODU Document of Compliance reducing total number of persons authorized.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 May 2016
Resolved
1499 - Propulsion & aux. Machinery (other) - Emergency generator cooling water hoses cracked & weeping & epoxy repair on jacket water sending unit housing. Make proper repair/replacement. (79 MODU Code/4.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class witnessed repairs to generator cooling hoses & thermostat housing gaskets.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Air supply system to all lifeboats leaking once energized, missing dogs to several windows, portable fire extinguishers not mounted, missing retroreflective material to external bottom hull, engine cover screws missing, & missing oar lock cover(s). Annual servicing suspect. Annual service required for all lifeboats. (79 MODU Code/10.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class examined repairs to #1 & #2 (ex #3) lifeboats. See attached ABS rpt HOM3147506 dtd 03Jun2016.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Provide updated fire safety appliance servicing report. (79 MODU Code/9) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached ABS class rpt HOM3147506 dtd 03Jun2016 details repairs/replacement of fire safety appliances aboard rig.
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Cutout modification to #1 & #3 lifeboat releasing gear support structure suspect. Provide class report indicating modification satisfactory &/or in accordance with manufacturer recommendation(s). (79 MODU Code/10.5) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating spacer over suspension bolt to retain spacing. Satisfactory according to manufacturer & Class.
Construction/Loadline › Structures › Door
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Doors to mudpit room not self-closing or gas-tight. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 details repairs to mudpit room doors.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Provide class report indicating PVC pipe used in all lifeboat sprinkler systems approved &/or in accordance with manufactuerer recommendation(s). (79 MODU Code/10.1) 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating PVC approved & in original construction. Satisfactory according to manufacturer & Class.
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2016
Resolved
1499 - Propulsion & aux. Machinery (other) - Fire hazard identified in minor fuel leaking from flame impingement bowl fittings of MDGs. (79 MODU Code/4.1) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating metallic fuel filters installed & sat.
Lifesaving › Lifebuoys › Approval
Issued 23 May 2016
Resolved
0650 - Fire fighting appliances (lifebuoys) - Fit lifebuoys with retroreflective material. (79 MODU Code/10.4) 50a
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 22Jun2016 indicating reflective tape applied to lifebuoys.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Remove temporary electrical cord from overhead in crew mess. (79 MODU Code/5) 50a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating temp elec cord removed.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #24. Cleared.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Each crane should be examined annually & verified by the Administration. (79 MODU Code/12.1.5) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Class completed annual exam & provided statement of fact HOM3147506 dtd 03Jun2016.
Construction/Loadline › Structures › Door
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Fire screen doors missing or have inoperative latches, throws, or self closing devices throughout rig. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 May 2016
Resolved
1270 - Load lines (doors) - Bottom lip of water tight door #27 wasted. Repair or replace. (ICLL Annex I/12) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating bottom lip of door cropped/renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Repair torn helicopter deck safety net as necessary. (79 MODU Code/13.3) 50ac
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating torn helo safety net repaired.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 23 May 2016
Resolved
0699 - Life saving appliance (other) - Bow & stbd leg means of embarkation (ladders from deck to surface of water) wasted, missing rungs, bent, &/or covered in barnacles. Repair/clean. (79 MODU Code/10.11) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Rcvd copy of RMI MODU Document of Compliance indicating scramble nets in lieu of fixed ladders authorized.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Provide proper portable fire extinguisher brackets throughout rig. (79 MODU Code/9.6) 50ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 indicates extinguishers were mounted w/ proper brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Repair lights throughout machinery spaces. (79 MODU Code/4.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating machinery space lights illuminated & sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 May 2016
Resolved
0715 - Fire fighting appliances (detection) - Heat detector above #2 MDG zip tied. Permanently install. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector perm installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016
Resolved
0740 - Fire fighting appliances (pumps) - J box cover missing at fire pump space. Install. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Loud speaker loose, J box cover missing, & J box loose near flag mast, & loose cable near fast rescue boat. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 3 H2S panel sensors in fault mode. Repair. (79 MODU Code/5.1) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating Gen II H2S & LEL detection sys installed/op tested sat.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #12. Rcvd emailed ABS survey rpt dtd 28May2016 indicating overall tank survey complete Feb 2016.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - E-light @ E-gen inoperative. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year crane load test records not available. Records found. (79 MODU Code/12.1.5) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Records found prior to our departure.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - E-gen distribution panel missing indicator lights, indicator light covers, & breaker actuators. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.