Records from 1981 to 2019. Most recent: inspection, 3 October 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 74
3 October 2019
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6830075
15 June 2018
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6507264
24 July 2017
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6310323
18 April 2017
Deficiency Check · COC-MODU Annual
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6099649
23 May 2016
Administrative Inspection · Deficiency Check · COC-MODU Renew
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5885770
12 April 2016
In-Service Inspection
Physical examination · Marine Safety Detachment Homer · USCG Arctic District (CGD-A) · Activity 6025105
6 January 2016
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5852571
24 May 2005
Deficiency Check
Physical examination · Activities Europe · Activity 2366735
14 July 1998
Administrative
Administrative · Activities Europe · Activity 794157
28 April 1998
Re-Inspection
Physical examination · Activities Europe · Activity 1372260
15 December 1997
Type not recorded
No type recorded · Activities Europe · Activity 55307
20 August 1997
Administrative
Administrative · Activities Europe · Activity 783268
16 May 1997
Deficiency Check
Physical examination · Activities Europe · Activity 1090858
2 April 1997
Administrative
Administrative · Activities Europe · Activity 1101802
12 March 1997
Type not recorded
No type recorded · Activities Europe · Activity 89387
4 February 1997
COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1357871
23 October 1996
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1160112
15 August 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1087236
19 May 1996
Re-Inspection
Physical examination · Activities Europe · Activity 1086215
21 March 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1078511
19 March 1996
Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1078908
7 December 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 880752
31 October 1995
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1183978
16 September 1995
Type not recorded
No type recorded · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 42840
1 May 1995
COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 919887
6 December 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1181635
12 October 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401931
29 September 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356826
17 June 1994
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354777
31 March 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 855201
11 December 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 37799
14 April 1993
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837657
19 April 1992
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267301
19 February 1992
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254789
1 January 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 10359
27 November 1991
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 939256
23 October 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1245905
15 April 1991
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919218
31 December 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921145
1 December 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1224234
2 November 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 903764
11 October 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909475
11 October 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1223403
20 August 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 925110
17 July 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910362
26 April 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 901911
9 March 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1217391
14 February 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915298
12 December 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922757
18 November 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914058
16 April 1989
COI Inspection · Deficiency Check · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 891342
4 October 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1199780
23 September 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 888530
13 July 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 895062
8 February 1988
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019801
28 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326231
15 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016368
25 August 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013096
5 March 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1315312
12 November 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1003315
21 October 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1321102
24 September 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314423
4 February 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305212
11 January 1986
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 996837
10 December 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992823
24 October 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301774
15 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983372
15 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289218
24 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976279
18 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276522
5 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969538
8 November 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967449
8 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964940
17 July 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273604
Documentation › Logs/Records › Oil Record Book
Issued 18 April 2017
Resolved
1710 - Oil record book - ORB shall be completed on each occasion when disposing of oil. Rig had numerous ORB entries of disposal ashore, but no receipts. (MARPOL 73/78 Annex I/17) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating oily wastes retained & disposed ashore. Ensured ABS knew to check for receipts per MARPOL Annex I/Appendix III.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock, fire, & explosion hazards…Dead-ended wire to right of camera box & temporary electrical cord run w/ other wires/cables in driller shack. (MI-293 Standard Part V.E.) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating temporary & dead-ended wires removed.
Accommodation/Occupational Safety › Ventilation › General
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Loss of ventilation is alarmed at manned station. Loss of ventilation alarm does not actuate when mud pit room doors are opened. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating alarm working as designed.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 18 April 2017
Resolved
0999 - Other(Safety in General)-Equipment should be certified as suitable for the flammable gas/air mixture which may be encountered. Purge alarms for camera panel & accumulator panel inoperative in driller shack. (79 MODU Code/6.6) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating purge alarms operative.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 April 2017
Resolved
0925 - Musters and drills - Emergency Evacuation drills must be conducted yearly & monthly. No records exercising EEP available. (33 CFR 146.125) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 25 April 2017
Resolution: Rcvd email records for EEP fire & volcanic eruption drills fm OIM.
Stability › Intact Stability (when using lifting gear) › General
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - 3rd party Feb/March 2017 crane reports indicate a number of “needs attention.” ABS report of 07Apr2017 does not rectify 3rd party notes/comments or reference them. (33 CFR 143.207, 46 CFR109.301) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 30 June 2017
Resolution: Rcvd ABS email/rpt indicating cranes repaired.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 April 2017
Resolved
0799 - Other (Fire fighting equipment) - Doors should be “A.” Both fire screen doors (FSD) btwn E/R & SCR room wasted at bottom & holes covered w/ tape. FSD & door jamb at 1st deck stairwell have holes. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating holes repaired using steel sheet.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 April 2017
Resolved
0715 - Detection - Appliances should be kept in good order & available for immediate use….Heat detector above #1 MDG hanging by wires, heat detector above #3 MDG ziptied, & center heat detector in mud pump room taped in place. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating detectors securely mounted & tested.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 April 2017
Resolved
1499 - Other(Prop. & Aux. Machinery)-Machinery must be maintained & operated in a safe manner at all times. E-gen exhaust piping leaking w/in e-gen room. (MI-293 Standard Part V.D.) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating no exhaust leaks noted.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Each helicopter deck should be fitted with lights around perimeter not more than 3 metres apart. One light extinguished & another flashing. (79 MODU Code/13.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 23 May 2017
Resolution: Rcvd ABS email/rpt indicating lights tested w/ none extinguished.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 18 April 2017
Resolved
0999 - Other(Safety in General)-Electrical equipment to be constructed to minimize electrical shock….Panel MCC SCR Aux NN2 missing bulb & cover. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Bulb & cover fitted prior to CG departure.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 April 2017
Resolved
0799 - Other(Fire fighting equipment)-Fire-extinguishing appliances should be available for immediate use….Electrician shop fixed fire extinguishing system controls & instructions blocked. (79 MODU Code/9.13) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Controls & instructions unblocked prior to CG departure.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 April 2017
Resolved
0999 - Other (Safety in General) - Electrical equipment to be constructed to minimize electrical shock….Speaker at 5th level, top deck loose. (MI-293 Standard Part V.E.) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 April 2017
Resolution: Speaker secured prior to CG departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 May 2016
Resolved
1799 - Other (MARPOL Annex 1) - Crew was unable to operationally test the oily water seperator (pump not working, already ordered. Oily waste pumpted to portable tanks & transported to shore). (73/78 MARPOL Annex I/14.6) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class issued new IOPP Cert w/ Form A requiring disposal of oil residues to reception facilities ashore.
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Crew unable to operationally test #2 lifeboat (fuel pump not working, already ordered). (79 MODU Code/10.1) 17ac
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Lifeboat removed fm svc. Class issued MODU Document of Compliance reducing total number of persons authorized.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 May 2016
Resolved
1499 - Propulsion & aux. Machinery (other) - Emergency generator cooling water hoses cracked & weeping & epoxy repair on jacket water sending unit housing. Make proper repair/replacement. (79 MODU Code/4.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class witnessed repairs to generator cooling hoses & thermostat housing gaskets.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Air supply system to all lifeboats leaking once energized, missing dogs to several windows, portable fire extinguishers not mounted, missing retroreflective material to external bottom hull, engine cover screws missing, & missing oar lock cover(s). Annual servicing suspect. Annual service required for all lifeboats. (79 MODU Code/10.1) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Class examined repairs to #1 & #2 (ex #3) lifeboats. See attached ABS rpt HOM3147506 dtd 03Jun2016.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Provide updated fire safety appliance servicing report. (79 MODU Code/9) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached ABS class rpt HOM3147506 dtd 03Jun2016 details repairs/replacement of fire safety appliances aboard rig.
Lifesaving › Launching Appliances › Release Mechanism
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Cutout modification to #1 & #3 lifeboat releasing gear support structure suspect. Provide class report indicating modification satisfactory &/or in accordance with manufacturer recommendation(s). (79 MODU Code/10.5) 17ac
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating spacer over suspension bolt to retain spacing. Satisfactory according to manufacturer & Class.
Construction/Loadline › Structures › Door
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Doors to mudpit room not self-closing or gas-tight. (79 MODU Code/6.3) 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 details repairs to mudpit room doors.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 23 May 2016
Resolved
0610 - Life saving appliance (lifeboats) - Provide class report indicating PVC pipe used in all lifeboat sprinkler systems approved &/or in accordance with manufactuerer recommendation(s). (79 MODU Code/10.1) 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2016
Resolved 3 June 2016
Resolution: Rcvd attached email through Class fm Harding (manufacturer) indicating PVC approved & in original construction. Satisfactory according to manufacturer & Class.
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2016
Resolved
1499 - Propulsion & aux. Machinery (other) - Fire hazard identified in minor fuel leaking from flame impingement bowl fittings of MDGs. (79 MODU Code/4.1) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating metallic fuel filters installed & sat.
Lifesaving › Lifebuoys › Approval
Issued 23 May 2016
Resolved
0650 - Fire fighting appliances (lifebuoys) - Fit lifebuoys with retroreflective material. (79 MODU Code/10.4) 50a
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 22Jun2016 indicating reflective tape applied to lifebuoys.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Remove temporary electrical cord from overhead in crew mess. (79 MODU Code/5) 50a
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating temp elec cord removed.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #24. Cleared.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Each crane should be examined annually & verified by the Administration. (79 MODU Code/12.1.5) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Class completed annual exam & provided statement of fact HOM3147506 dtd 03Jun2016.
Construction/Loadline › Structures › Door
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Fire screen doors missing or have inoperative latches, throws, or self closing devices throughout rig. (79 MODU Code/9.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 23 May 2016
Resolved
1270 - Load lines (doors) - Bottom lip of water tight door #27 wasted. Repair or replace. (ICLL Annex I/12) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating bottom lip of door cropped/renewed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Repair torn helicopter deck safety net as necessary. (79 MODU Code/13.3) 50ac
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating torn helo safety net repaired.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 23 May 2016
Resolved
0699 - Life saving appliance (other) - Bow & stbd leg means of embarkation (ladders from deck to surface of water) wasted, missing rungs, bent, &/or covered in barnacles. Repair/clean. (79 MODU Code/10.11) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Rcvd copy of RMI MODU Document of Compliance indicating scramble nets in lieu of fixed ladders authorized.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 May 2016
Resolved
0799 - Fire fighting appliances (other) - Provide proper portable fire extinguisher brackets throughout rig. (79 MODU Code/9.6) 50ac
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Attached Class rpt HOM3147506 dtd 03Jun2016 indicates extinguishers were mounted w/ proper brackets.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Repair lights throughout machinery spaces. (79 MODU Code/4.2) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating machinery space lights illuminated & sat.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 23 May 2016
Resolved
0715 - Fire fighting appliances (detection) - Heat detector above #2 MDG zip tied. Permanently install. (79 MODU Code/9.13) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector perm installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016
Resolved
0740 - Fire fighting appliances (pumps) - J box cover missing at fire pump space. Install. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating heat detector installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - Loud speaker loose, J box cover missing, & J box loose near flag mast, & loose cable near fast rescue boat. (79 MODU Code/5.5) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 13 October 2016
Resolution: Rcvd email fm ABS via rig indicating correction.
Electrical › Electrical Distribution System (emergency) › Switch
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 3 H2S panel sensors in fault mode. Repair. (79 MODU Code/5.1) 50a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 7 July 2016
Resolution: Rcvd emailed ABS survey rpt dtd 28May2016 indicating Gen II H2S & LEL detection sys installed/op tested sat.
Engineering › Pressure Vessel › Shell Plate
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year internal examination records for P tanks 1-3, 5 & 6, & unfired pressure vessels not available. (46CFR61.10-5(b)(2), MSM Vol II/G.3.G.4) 50ac
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 3 June 2016
Resolution: Same as #12. Rcvd emailed ABS survey rpt dtd 28May2016 indicating overall tank survey complete Feb 2016.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - E-light @ E-gen inoperative. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.
Stability › Intact Stability (when using lifting gear) › General
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - 5 year crane load test records not available. Records found. (79 MODU Code/12.1.5) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 May 2016
Resolution: Records found prior to our departure.
Electrical › Electrical Distribution System (emergency) › Panelboard
Issued 23 May 2016
Resolved
0999 - Safety in general (other) - E-gen distribution panel missing indicator lights, indicator light covers, & breaker actuators. Repaired. (79 MODU Code/5.1) 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 23 May 2016
Resolution: Repaired prior to our departure.
Lifesaving › Inflatable Liferafts › Approval
Issued 28 April 1998
Resolved
Provide Muster List onboard which complies with 46 CFR 108.901.
Condition: Unknown
Due 28 June 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED ALL DEF''S CLEARED.
Lifesaving › Launching Appliances › Falls
Issued 28 April 1998
Resolved
RENEW ALL LIFEBOAT/LIFERAFT FALLS. WEIGHT TEST SAME AT NEXT USCG MARINE INSPECTOR VISIT TO BE COORDINATED WITH THIS OFFICE.
Condition: Unknown
Due 30 July 1998
Resolved 24 May 2005
Resolution: VESSEL REFLAGGED ALL DEF''S CLEARED.
Construction/Loadline
Issued 4 February 1997
Resolved
Provide MIO Europe with ABS Survey report of preload and skimming valve inspection report (10% of each valve).
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Construction/Loadline
Issued 4 February 1997
Resolved
Provide MIO Europe with results of bottom (spud can and barge) inspection.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Construction/Loadline
Issued 4 February 1997
Resolved
Provide MIO Europe with gauging report (preload, spud can and bottom plating).
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Lifesaving
Issued 19 May 1996
Resolved
FAX A COPY OF THE RAFT SERVICING CERTIFICATE TO MIO EUROPE WHEN THE REPLACEMENT FOR RAFT #4 IS INSTALLED ON BOARD.
Condition: Unknown
Due 19 May 1996
Resolved 19 May 1996
Fire Fighting
Issued 19 May 1996
Resolved
PROVIDE AN ADDITIONAL B-V FIRE EXTINGUISHER FOR THE HELICOPTER DECK. ONE ISREQUIRED AT EACH ACCESS.
Condition: Unknown
Due 19 May 1996
Resolved 19 May 1996
Electrical
Issued 1 May 1995
Resolved
REPAIR EMERGENCY GENERATOR SO IT CAN HANDLE THE REQUIRED LOAD AS INDICATED ON THE EMERGENCY SWITCH BOARD.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Electrical
Issued 1 May 1995
Resolved
PROVIDE NEW TEMERATURE SENSOR FOR EMERGENCY GENERATOR
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Construction/Loadline
Issued 17 June 1994
Resolved
PREPARE ALL THREE SPUD CANS AND CRITICAL AREAS FOR INTERNAL & EXTERNAL EXAMINATION BY A COAST GUARD MARINE INSPECTOR TO COMPLETE THE VESSEL'S SEILOD DURING THE RIG'S NEXT MOVE BUT NOT LATER THAN 31 OCTOBER 1994.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Lifesaving
Issued 17 June 1994
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE FIXED COMBUSTIBLE GAS DETECTION SYSTEM (LEL), ROW TWO, NOS. 4,6,8,9, AND 10 LOCATED IN THE RADIO ROOM IN THE PRESENCE OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Lifesaving
Issued 17 June 1994
Resolved
REPLACE THE (1) FAULTY BATTERY FOR THE FIRE DETECTION CONTROL PANEL LOCATEDIN THE RADIO ROOM.
Condition: Unknown
Due 31 July 1994
Resolved 26 June 1994
Fire Fighting
Issued 17 June 1994
Resolved
HAVE NITROGEN BOTTLE FOR THE SEMI-PORTABLE DRY CHEMICAL FIRE EXTINGUISHER ON THE HELO DECK AND ALL 15LB PORTABLE CO2 BOTTLES SENT TO AN APPROVED DOT FACILITY FOR HYDROSTATIC TESTING. PRIOR TO REMOVING FIREFIGHTING EQUIPMENTFOR SERVICING, ADEQUATE REPLACEMENTS OR SUBSTITUTES MUST BE ONBOARD.
Condition: Unknown
Due 17 June 1994
Resolved 17 June 1994
Fire Fighting
Issued 15 April 1991
Resolved
RENEW EXPANSION JOINTS ON FIREMAIN AT PRIMARY FIREPUMP.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Fire Fighting
Issued 15 April 1991
Resolved
PRESENT THE (3) HALON SYSTEM REMOTE ACTUATOR BOTTLES FOR HYDROSTATIC TESTING AT A D.O.T. APPROVED FACILITY. THE HALON SYSTEM IS TO REMAIN FULLYOPERABLE WHILE THE SUBJECT ACTUATOR BOTTLES ARE ASHORE.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Fire Fighting
Issued 15 April 1991
Resolved
SUBMIT TO G-MSC FOR APPROVAL, PLANS TO MODIFY THE FIREMAIN PIPING IN SUCH AMANNER THAT THE FIREMAIN SUPPLY CAN BE LOCALLY ISOLATED FROM THE SALTWATER SERVICE SYSTEM. IN CURRENT ARRANGEMENT WATER, FROM THE SALTWATER SERVICE PUMP TRAVELS THROUGH SERVICE MAIN PRIOR TO REACHING FIRE MAIN.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Construction/Loadline
Issued 15 April 1991
Resolved
PROVIDE ONE COPY OF THE UNDERWATER SURVEY AND NDT REPORT INCLUDING VIDEO TAPE AND ONE COPY OF THE TOPSIDE NDT INSPECTION REPORT TO [name withheld]._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1991
Resolved 8 August 1991
Unknown
Issued 26 April 1990
Resolved
CONDUCT HYDROSTATIC TEST OF ENGINE ROOM HALON BOTTLE WITH LAST HYDROSTATIC TEST DATE OF 3-78. WHEN BOTTLE IS REMOVED FOR SERVICING IT MUST BE REPLACEDWITH ANOTHER BOTTLE OF EQUAL VOLUME AND CURRENT TEST DATE.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Documentation
Issued 9 March 1990
Resolved
SUBMIT COPIES OF PERMANENT STABILITY LETTER AND LOADLINE CERTIFICATE UPON RECEIPT TO USCG [name withheld], HI.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Unknown
Issued 14 February 1990
Resolved
(ADMINISTRATIVELY ISSUED) PROVIDE TO [name withheld] A COPY OF THE FOLLOWING APPROVED PLANS: MS 4750 AND ME 3120.
Condition: Unknown
Due 14 February 1990
Resolved 14 February 1990
Electrical
Issued 12 December 1989
Resolved
RESUBMIT FIRE CONTROL PLAN TO REFLECT ADDITIONS MADE TO PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 December 1989
Resolved 12 December 1989
Accommodation/Occupational Safety
Issued 18 November 1989
Resolved
ENSURE THAT HOSPITAL SPACE HAS ONE BUNK ACCESSIBLE FROM BOTH SIDES AND THATALL TOP BUNKS ARE HINGED FOR PROPER LIFTING AND ACCESS.
Condition: Unknown
Due 18 November 1989
Resolved 18 November 1989
Documentation
Issued 16 April 1989
Resolved
(ADMINISTRATIVELY ISSUED) PROVIDE TO [name withheld], HI, A COPY OF THE FOLLOWING APPROVED PLANS: 1) MS 4750 (QUARTERS ARRANGEMENT; 2) ML 691 THROUGH 695 (ELECTRICAL); AND 3) ME 3118, 3120, 3126, AND 3127 (PIPING).
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Documentation
Issued 16 April 1989
Resolved
SUBMIT COPIES OF PERMANENT STABILITY LETTER AND LOADLINE CERTIFICATE UPON RECEIPT TO USCG [name withheld], HI.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Fire Fighting
Issued 16 April 1989
Resolved
INSTALL WARNING LIGHTS FOR GENERAL ALARM IN HIGH NOISE AREAS: WAREHOUSE, COMPRESSION ROOM, AND MUD PIT AREA.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Accommodation/Occupational Safety
Issued 16 April 1989
Resolved
INSTALL/REINSTALL NON-SLIP SHEETS OR EQUIVALENT ON ALL STAIRWAYS WHERE SERRATED GRATING IS NOT INSTALLED.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Electrical
Issued 16 April 1989
Resolved
CONDUCT MEGGER TEST OF ALL ITEMS LISTED ON KEPPEL SHIPYARD MEGGER TEST REPORT WHERE THE INSULATION RESISTANCE WAS LESS THAN PARAGRAPH 46.2.1 OF IEEE STANDARD NO. 45. SUBMIT FINDINGS TO USCG [name withheld], HI.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Electrical
Issued 16 April 1989
Resolved
INSTALL ADDITIONAL LIGHTING TO THE PORT AND STARBOARD STAIRWAYS TO THE HELIDECK WHERE LIGHTING DOES NOT COVER THE STAIRWAY RUNS.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Electrical
Issued 16 April 1989
Resolved
INSTALL PROPER EMERGENCY LIGHTING AT THE STARBOARD FORWARD LIFERAFT.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Electrical
Issued 16 April 1989
Resolved
REWIRE THE PORT AND STARBOARD AFTER LIFERAFT LIGHTS TO THE EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Accommodation/Occupational Safety
Issued 16 April 1989
Resolved
SUBMIT CREW ACCOMMODATION PLANS TO COMMANDANT (G-MTH) FOR APPROVAL.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Fire Fighting
Issued 16 April 1989
Resolved
POST RIG LAYOUT DIAGRAM FOR SMOKE/HEAT/H2S/GAS DETECTORS TO COINCIDE WITH ALARM PANELS.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Lifesaving
Issued 16 April 1989
Resolved
PROVIDE SUITABLE LOCKER FOR PYROTECHNICS IN THE DECK LEVEL CONTROL ROOM.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Navigation
Issued 16 April 1989
Resolved
FOCUS AND SYNCHRONIZE THE OBSTRUCTION LIGHTS.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Accommodation/Occupational Safety
Issued 16 April 1989
Resolved
ENSURE THAT THE TWO EXTRA BUNKS IN ROOMS 201 AND 207 ARE USED ONLY FOR TRANSIENT PERSONNEL, AND THEN ONLY AFTER RECEIPT OF WRITTEN PERMISSION FROMCOMMANDANT (G-MTH), U.S. COAST GUARD, WASHINGTON, DC.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Accommodation/Occupational Safety
Issued 16 April 1989
Resolved
SUBMIT COPY OF PERMISSION LETTER TO BERTH GREATER THAN FOUR PERSONS IN ROOMS 201 AND 207 TO USCG [name withheld], HI.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Deck/Cargo
Issued 16 April 1989
Resolved
PROVIDE COPIES OF CRANE SURVEYS TO USCG [name withheld], HI.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Documentation
Issued 16 April 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Fire Fighting
Issued 16 April 1989
Resolved
RENEW OR REPLACE CLOSING DEVICE ON PAINT LOCKER DOOR TO ENSURE POSITIVE CLOSURE.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Deck/Cargo
Issued 16 April 1989
Resolved
PROVIDE USCG APPROVAL FOR THE INSTALLATION OF CEMENTING UNIT PRIME MOVER AND FUEL SUPPLY TANKS LOCATED STARBOARD SIDE BELOW MAIN DECK UNDER LIVING QUARTERS.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Accommodation/Occupational Safety
Issued 16 April 1989
Resolved
REPLACE RUSTED FOOD STORAGE RACKS IN COOLER.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Construction/Loadline
Issued 16 April 1989
Resolved
RENEW PORT AFTER LADDER ON PORT LEG.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Deck/Cargo
Issued 16 April 1989
Resolved
RENEW RUBBER EXPANSION JOINTS AT VENTS ON DRILL ON DRILL FLOOR WHERE WRAPPED WITH TAPE.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Deck/Cargo
Issued 16 April 1989
Resolved
REPLACE THE OPERATIONAL ALARMS FOR THE CRANE.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Fire Fighting
Issued 16 April 1989
Resolved
REPLACE ALL FIRE EXTINGUISHER BRACKETS THAT ARE MISMATCHED OR IMPROPER FOR THE PORTABLE FIRE EXTINGUISHER ON LOCATION.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Electrical
Issued 16 April 1989
Resolved
LABEL ALL CONTROLLERS AND SWITCHES FOR EQUIPMENT BEING SERVED.
Condition: Unknown
Due 16 April 1989
Resolved 16 April 1989
Lifesaving
Issued 23 September 1988
Resolved
WEIGHT TEST NUMBERS ONE AND TWO LIFE CAPSULES IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 September 1988
Resolved 23 September 1988
Unknown
Issued 23 September 1988
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF DRILL CONSOLE PURGE AIR FAILURE ALARM
Condition: Unknown
Due 23 September 1988
Resolved 23 September 1988
Construction/Loadline
Issued 13 July 1988
Resolved
REPAIR AS NECESSARY THE FOLLOWING DOORS/HATCHES ON THE MAIN DECK - PORTSIDEMAIN DECK HATCH, VARIOUS DOORS ON THE MAIN DECK PER 46 CFR 108.114,NVC4-78.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Construction/Loadline
Issued 13 July 1988
Resolved
COMPLETE SPECIAL EXAM IN LIEU OF DRYDOCKING UNDERWATER PORTION OF LEG TO CAN AND LEGS FROM 168' TO THE CAN PER 46 CFR 107-267.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Construction/Loadline
Issued 13 July 1988
Resolved
REPAIR AS NECESSARY THE WATERTIGHT DOOR TO MUD PUMP ROOM PORT SIDE AND GEN/ENG ROOM STBD SIDE PER 46 CFR 108.114, NVC 4-78.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Fire Fighting
Issued 13 July 1988
Resolved
REPAIR/REPLACE FLEXIBLE LOOPS ON THE SCR ROOM AND ONE ENG ROOM CO2 ACTUATORBOTTLES FOR THE HALON SYSTEM PER 46 CFR 108.431.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Engineering
Issued 13 July 1988
Resolved
REPLACE AS NECESSARY THE WASTED PIPING ON THE BILGE EDUCTOR PIPING, BILGE PUMP ROOM PER 46 CFR 56, NVC 4-78.
Condition: Unknown
Due 13 July 1988
Resolved 13 July 1988
Electrical
Issued 25 August 1987
Resolved
PROVIDE ALL GENERAL ALARM BELL FOR THE WAREHOUSE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
MAKE OPERABLE THE LOSSSS OF VENTILATION ALARM AT DRILLERS CONSOLE.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 25 August 1987
Resolved
PROVIDE ONE BI FIRE EXTINGUISHER FOR FORK LIFT; TO BE A 4 LB DRY CHEM EXT.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
REMOVE SWITCHES MARKED A/C SHUTDOWNS LOCATED AT EXIT DOORS IN STAIR WELLS THESE SWITCHES HAVE BEEN DIXCONNECTED.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Electrical
Issued 25 August 1987
Resolved
APPROPIATELY REATTACH DECK FLOOD LIGHT ON PORT SIDE BY CRANE BOOM CRADELES LOCATED AT PORT LIFEBOAT
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Navigation
Issued 25 August 1987
Resolved
PROVIDE NEW COMPASS FOR PORT LIFE BOAT.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Fire Fighting
Issued 24 September 1986
Resolved
REPAIR THE LEAK FROM THE SHAFT ON THE FOAM-FIRE PUMP IN THE BULK TANK ROOM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Accommodation/Occupational Safety
Issued 24 September 1986
Resolved
MAKE THE SANITARY PUMPS OPERATIONAL UPON ACTIVATION OF THE RIG.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Deck/Cargo
Issued 24 September 1986
Resolved
REMOVE OR MAKE OPERABLE THE VESSEL'S FORKLIFT.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Electrical
Issued 24 September 1986
Resolved
REMOVE OR MAKE OPERABLE THE WEATHER DECK ENGINE FAILURE ALARM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Accommodation/Occupational Safety
Issued 24 September 1986
Resolved
MAKE THE MARINE SANITATION DEVICE OPERATIONAL.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Electrical
Issued 24 September 1986
Resolved
MAKE THE MUD PIT ROOM'S EXHAUST FAN FAILURE ALARM OPERATIONAL.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Lifesaving
Issued 24 September 1986
Resolved
PROVIDE ONBOARD TWO SPARE SCUBA BOTTLES WITH CURRENT HYDROSTATIC TEST DATES.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Lifesaving
Issued 24 September 1986
Resolved
CHANGE FUEL IN BOTH OF THE LIFE CAPSULES AND MAKE AN APPROPRAITE LOG ENTRY.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Lifesaving
Issued 24 September 1986
Resolved
CONDUCT A WEIGHT TEST OF BOTH THE CAPSULE DAVITS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Documentation
Issued 24 September 1986
Resolved
PROVIDE ONBOARD A CURRENT FMC CERTIFICATE.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Electrical
Issued 24 September 1986
Resolved
UPON ACTIVATION OF THE RIG, REMOVE THE TEMPORARY INSTALLED DEHUMIDIFIER ANDASSOCIATED WIRING.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Deck/Cargo
Issued 24 September 1986
Resolved
MAKE THE HELO REFUELING PUMP INDICATOR LIGHT OPERABLE.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Electrical
Issued 24 September 1986
Resolved
REPLACE ONE EYS FITTING IN THE SHALE SHAKER AREA NEAR THE CYCLONE UNIT.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Electrical
Issued 24 September 1986
Resolved
REMOVE OR MAKE A PERMANENT INSTALLATION OF THE CONSTAVOLT BATTERY CHARGER IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Unknown
Issued 24 September 1986
Resolved
MAINTAIN THE OIL RECORD BOOK ISSUED THIS INSPECTION.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986
Construction/Loadline
Issued 11 January 1986
Resolved
INSPECT THE SEA SUCTION VALVES, AT LEAST (3) THREE PRELOAD DUMP VALVES, ANDTHE OVERBOARD VALVE SERVICING THE HALLIBURTON CEMENT UNIT.
Condition: Unknown
Due 11 January 1986
Resolved 11 January 1986
Construction/Loadline
Issued 11 January 1986
Resolved
CONDUCT AN EXTERNAL EXAM OF HULL SIDES AND BOTTOM.
Condition: Unknown
Due 11 January 1986
Resolved 11 January 1986
Deck/Cargo
Issued 24 October 1985
Resolved
PROVIDE ONBOARD THE RIG ONE STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Electrical
Issued 24 October 1985
Resolved
INSTALL AN OVERSPEED TRIP ON THE EMERGENCY GENERATOR AND TEST THE SAME IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Electrical
Issued 24 October 1985
Resolved
REPAIR THE INOPERABLE #2 SANITARY PUMP.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Fire Fighting
Issued 24 October 1985
Resolved
REPLACE OR REPAIR THE 12 FOOT LONG FOG APPLICATOR AT FIRE STATION #22 SO THAT IT WILL LOCK IN THE NOZZLE.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Fire Fighting
Issued 24 October 1985
Resolved
REPLACE OR HAVE SERVICED THE B-V EXTINGUISHER AT STATION #17 AT THE HELICOPTER DECK.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Fire Fighting
Issued 24 October 1985
Resolved
REPLACE OR HAVE THE THREE OUT OF DATE SCBA AIR BOTTLES HYDROSTATICALLY TESTED.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Navigation
Issued 24 October 1985
Resolved
REALIGN BOTH NAVIGATIONAL SIDE LIGHTS TO SHOW DEAD AHEAD TO 22 1/2 DEGREES AFT OF THE BEAM
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Fire Fighting
Issued 24 October 1985
Resolved
REFILL THE EMPTY FOAM TANK FOR THE INSTALLED FOAM SYSTEM FOR THE HELICOPTER DECK.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Accommodation/Occupational Safety
Issued 24 October 1985
Resolved
RECONSTRUCT THE HAND RAIL AROUND THE EMBARKATION DECK OF THE PORT LIFE CAPSULE SO THAT THE LOWEST COURSE IS NO MORE THAN NINE INCHES ABOVE THE DECK AND THE NEXT TWO COURSES ARE NO MORE THAN FIFTEEN INCHES APART.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Deck/Cargo
Issued 24 October 1985
Resolved
COMPLETE THE ANNUAL CRANE SURVEY
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Deck/Cargo
Issued 24 October 1985
Resolved
INSTALL A HELICOPTER FUEL TRANSFER PUMP OPERATION INDICATING LIGHT AT THE PUMP OPERATING STATION AND TEST THE SAME.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Deck/Cargo
Issued 24 October 1985
Resolved
INSTALL OPERATION INDICATING BELLS ON BOTH FORKLIFTS.
Condition: Unknown
Due 24 October 1985
Resolved 24 October 1985
Navigation
Issued 18 August 1983
Resolved
PROVIDE ONE 360 DEGREE AFT ANCHOR LIGHT.
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Deck/Cargo
Issued 18 August 1983
Resolved
PROVIDE EVIDENCE OF VECENT ANNUAL CRANE SURVEY OR SERVICE AS REQUIRED (46 CFR 107.258)
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Lifesaving
Issued 18 August 1983
Resolved
PROVIDE ONE ADDITIONAL SMOKE POT FOR RIG
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Lifesaving
Issued 18 August 1983
Resolved
REPLACE OR PROVIDE PML'S ON LIFEJACKETS AS NECESSARY.
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Lifesaving
Issued 18 August 1983
Resolved
PROVIDE THE FOLLOWING FOR THE LINE THROWING GUN: A. TWO SERVICE LINES, B) ONE PROJECTILE, C) TEN CARTRIDGES.
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Navigation
Issued 18 August 1983
Resolved
REPLACE NAV. LIGHT SOCKET AND BULBS WITH APPROVED AS ORIGINAL EQUIPMENT.
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Deck/Cargo
Issued 18 August 1983
Resolved
HYDROSTATICALLY TEST FUEL OIL TRANSFER HOSE TO 1 1/2 THE WORKING PRESSURE BUT NOT MORE THAN 200 PSI (33CFR 157)
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Electrical
Issued 18 August 1983
Resolved
TROUBLE SHOOT THE EMERGENCY GENERATOR START INTERFACE TO THE ALARM CIRCUITSAND REPAIR AS NECESSARY FOR PROPER GENERATOR STARTING.
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Deck/Cargo
Issued 18 August 1983
Resolved
REPLACE THE MISSING AND HOLED FLAME SCREENS ON THE VENTS TO THE PORT AND STBD FUEL OIL TANKS EMERGENCY GENERATOR FUEL OIL TANK AND PAINT LOCKER VENT
Condition: Unknown
Due 18 August 1983
Resolved 18 August 1983
Fire Fighting
Issued 8 January 1982
Resolved
SUBMIT SAMPLE OF FOAM TO MFG. OR AUTHORZIED AGENT FOR ANALYSIS IN ACCOR- DANCE WITH 46 CFR 107.235 (6) (III)
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982
Lifesaving
Issued 8 January 1982
Resolved
PROVIDE OXYGEN ANALYIZER/EXPLOSION METER FOR EMERGENCY GEAR LOCKER.
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982
Navigation
Issued 8 January 1982
Resolved
ALIGN OBSTRUCTION LIGHTS TO ENSURE PROPER RANGE.
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982
Electrical
Issued 8 January 1982
Resolved
REPAIR GENERAL ALARM BELL IN MUD PIT ROOM.
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982
Electrical
Issued 8 January 1982
Resolved
PROPERLY SECURE STROKE COUNTER WIRING IN MUD PUMP ROOM.
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982
Unknown
Issued 8 January 1982
Resolved
REPAIR ALARM ON DRILLERS CONSOL AIR PURGE SYSTEM.
Condition: Unknown
Due 8 January 1982
Resolved 8 January 1982