Records from 2016 to 2026. Most recent: inspection, 9 February 2026.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 February 2026
Resolved
Vessel required to have updated charts. Paper charts on board were not up to date and electronic charts not for commercial vessels.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2026
Resolved 24 February 2026
Resolution: Updated charts onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 February 2026
Resolved
Emergency power source or battery must be provided in addition to normal power for fire detection. When normal power secured the fire detection was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2026
Resolved 24 February 2026
Resolution: Fire detection tested during blackout.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 February 2026
Resolved
Vessels < than 500 gt on domestic voyages not required rescue boat if the OCMI determines the vessel is arranged to recover a helpless person from the water. Vessel was light in the stern and the non approved boat/platform drill was not adequate to recover a person.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 9 February 2026
Resolved 24 February 2026
Resolution: Recovered OSCAR from water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 February 2026
Resolved
Inspectors shall examine the vessel’s machinery and equipment to be assured that it is in satisfactory condition. A portion of lagging was missing on exhaust piping within the port exhaust stack.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 February 2026
Resolved 24 February 2026
Resolution: Lagging installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2026
Resolved
The scope of an inspection includes Fire hose shall be subjected to a test pressure equivalent to the max pressure of system or 100 psi whichever is greater. Fire pump could only produce 80 psi.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 24 February 2026
Resolution: Witnessed tests of fire hoses.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 9 February 2026
Resolved
Inspection for certification shall ensure that the vessel is in possession of valid certificates issued by the FCC. Vessel has DSC capable VHF radio at the forward operating station, but MMSI number is not inputed limiting DSC capability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 February 2026
Resolved 24 February 2026
Resolution: MMSI inputed.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 9 February 2026
Resolved
A vessel engaged in commercial service, shall maintain a video surveillance system. Video surveillance system is installed, but at the time of attendance the breaker panel supplying power was secured.
46 (U.S.C.) 4901
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 February 2026
Resolved 9 February 2026
Resolution: Breaker 3 closed on bridge. Power to system restored.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 9 February 2026
Resolved
COI requires immersion suits unless vessel is only operating between 32 degrees north and south latitudes. Vessel log indicated that vessel was on contract in Little Creek, Va, where the suits are required. No record of any being placed on board.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 February 2026
Resolved 9 February 2026
Resolution: Vessel not currently operating in area where suits required. Informed crew of the requirement when leaving the Gulf.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 January 2025
Resolved
At each inspection, MI must conduct such tests of main propulsion machinery and its associated equipment as they feel necessary to check safe operation.
Overspeed shutdown of STBD MDE did not work. Restore back to operational order.
Cite: 46 CFR 61.20-3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2025
Resolved 27 January 2025
Resolution: Received tech report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 April 2023
Resolved
No repairs or alterations affecting the safety of the vessel with regard to machinery or equipment shall be made without the knowledge of the OCMI. Vessel reported loss of propulsion/generator failure while underway. Vessel rep stated port day tank sounding tube was left open resulting in water ingress into the port day tank. Determine extent of damage, conduct repairs as necessary, and provide report from maintenance provider to the satisfaction of a CG Marine Inspector. 46 CFR 91.45-1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2023
Resolved 12 April 2023
Resolution: Received tech report for drainage of water from fuel components.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 January 2023
Resolved
Each generator prime mover must have an overspeed device. Starboard generator overspeed sensor inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 30 January 2023
Resolution: Technician fixed sensor. Operational test conducted.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 30 January 2023
Resolved
Each watertight door must be designed to withstand a head of water from the sill of the door to the margin line.
Watertight door in the rudder room and both engine room escape doors had the wrong gasket material.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2023
Resolved 31 January 2023
Resolution: ABS surveryor verified and cleared finding during ILLC exam.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 30 January 2023
Resolved
Each liferaft must be arranged for float free launching with an approved hydrostatic release. Hydrostatic release on port side was expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2023
Resolved 31 January 2023
Resolution: Replaced hydrostatic release
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 30 January 2023
Resolved
Boundary bulkheads for machinery spaces shall be of class a construction. Fire stop missing in engine room boundary.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2023
Resolved 31 January 2023
Resolution: ABS surveryor verified and cleared finding during ILLC exam.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 January 2023
Resolved
Before the vessel leaves port, all lifesaving appliances must be in working order and ready for immediate use. Rescue boat fuel line needs to be replaced due to leak.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 February 2023
Resolved 31 January 2023
Resolution: Witnessed operation, launch, and retrieval of rescue boat. Fuel line was also replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 January 2021
Resolved
Vessel shall maintain watertight integrity. Vessel had a watertight gasket that was showing signs of degradation on the engine room quick acting watertight door. Vessel shall replace gasket to maintain watertight integrity.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 1 March 2021
Resolution: Vessel rep provided picture via email showing the gasket was replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2021
Resolved
Vessel shall maintain the clutch to work IAW manufacture specifications. Clutch was observed to discharge a stream of oil when engaged. Vessel shall either make repairs or replace clutch IAW manufacture specifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 1 March 2021
Resolution: Vessel rep sent email with a picture of the replaced clutch
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2021
Resolved
Vessel shall use non-metallic flexible hose IAW SAE J1942 and may be installed in lube oil and fuel systems, and fluid power systems. Vessel was observed to have six (6) non SAE J1942 air brake hoses being used in lube oil or fuel systems in the engine room. Vessel shall replace
non SAE J1942 hoses with approved SAE J1942 hoses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 2 March 2021
Resolution: Vessel replaced air brake hoses with SAEJ1942 hoses.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 January 2021
Resolved
Each generator prime mover must have an overspeed and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Vessel #2 generator overspeed is not functional. Vessel shall ensure that vessel overspeed is functioning properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 25 January 2021
Resolution: Overspeeds were addressed by a 3rd party on 1/25/2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 January 2021
Resolved
There must be ground detection for the ships's service power system. The ground detection test button for the 280V panel was not functional. Vessel shall ensure that the ground detection system and test is functional.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 1 March 2021
Resolution: Vessel rep sent picture of ground fault indicator replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 January 2021
Resolved
Vessel shall maintain the jacket water system IAW manufacture specifications. Jacket water system pump was leaking jacket water fluid. Vessel shall either repair or replace jacket water system pump to ensure the pump does not leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 February 2021
Resolved 1 March 2021
Resolution: Vessel Rep sent email with repair ticket from Caterpillar.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 18 March 2020
Resolved
Emergency lights shall be provided. 04 Emergency lights @ embarkation stations not operable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: A blown fuse was ID’ d as the issue, possibly caused by a sealed bulb STBD side which had moisture. Bulb replaced and fuse replaced. E-lights operable.
11 - Life Saving Appliances › N/A - No Subsystem › Line-throwing appliance
Issued 18 March 2020
Resolved
500 ft of line required for line throwing gun. Line not onboard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2020
Resolution: Line placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 March 2020
Resolved
Each battery with an expiration date must be replaced if expired. 03 lifebuoy lights had expired batteries installed.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 March 2020
Resolution: Batteries replaced prior to completion of inspection.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 March 2020
Resolved
Updated charts shall be available for areas of operation. Chart for area of operation last updated 2012.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: Updated chart onboard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 March 2020
Resolved
Fire hazards shall be minimized. F/O Leaks identified on both MDE’s and F/O manifold valve at meter.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2020
Resolution: MDE leaks were corrected by Caterpillar Technicians before completion of inspection, Fuel valve replaced by crew after we departed vessel.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 February 2019
Resolved
Bilge sensor for the aft engine room passageway was non-operational. Prove proper operation prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2019
Resolved 7 February 2019
Resolution: Witnessed the operation of the bilge sensor in the aft engine room passageway. Deficiency cleared to the satisfaction of the attending CG marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 February 2019
Resolved
Overspeeds on port main engine were non-operational. Prove proper operation prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2019
Resolved 7 February 2019
Resolution: Witnessed operartion of the overspeeds on the port main engine. Deficiency cleared to the satisfaction of the attending CG marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
Gorund detection system was inoperable. Repair to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 21 May 2019
Resolution: Recieved verification that the deficiency has been resolved to CG marine inspector satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
Dive shack was wired using flexible cords. Flexible cords may not be used as a substitute for permanent wiring in accordance with 46 CFR 111.60-13 and NEC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 21 May 2019
Resolution: Recieved verification that the deficiency has been resolved to CG marine inspector satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
Battery charger on top of switchboard is not properly mounted and is wired with flexible cord which is not permissable by 46 CFR and NEC.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 21 May 2019
Resolution: Recieved verification that the deficiency has been resolved to CG marine inspector satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 February 2019
Resolved
Lighting fixture in steering compt. passageway was not properly secured to the overhead.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 21 May 2019
Resolution: Recieved verification that the deficiency has been resolved to CG marine inspector satisfaction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2019
Resolved
Vessel's shaft tach indicators on the bridge and in the e/r were not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2019
Resolved 21 May 2019
Resolution: Recieved verification that the deficiency has been resolved to CG marine inspector satisfaction.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 21 February 2018
Resolved
RAI on bridge not working properly only goes 30 to 30.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2018
Resolution: Third party fixed wiring.
Engineering › Diesel Engine (propulsion-reduction gear) › Emergency shutdown
Issued 21 February 2018
Resolved
Port side e-shutdowns on bridge inop.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 February 2018
Resolved
E-light at port side embarkation station inop.
Action required: 705 - Other - as specified
Due 27 February 2018
Resolved 21 February 2018
Resolution: New bulb installed.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 February 2018
Resolved
Rescue boat missing aft plugs.
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 7 March 2018
Resolution: Added new boat plugs.
Lifesaving › Rescue Boat › Markings
Issued 21 February 2018
Resolved
reg sticker missing. Vessel does have the reg paperwork.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 7 March 2018
Resolution: Recieved new sticker for EPIRB.
Electrical › Lighting (emergency) › Switch
Issued 18 January 2017
Resolved
Nav light panel does not provide fuse audible alarm.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2017
Resolved 19 January 2017
Resolution: 3rd party repaired audible alarm.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 18 January 2017
Resolved
Cooling water pipe on stern thruster near non metalic expansion joint was corroded and leaking.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2017
Resolved 19 January 2017
Resolution: C/R corroded portion of piping.
Electrical › Electric Supply System (service) › Cable
Issued 18 January 2017
Resolved
Spliced cables leading to propulsion system.
Condition: Improper Installation
Due 18 January 2017
Resolved 19 January 2017
Resolution: Cables properly placed into a junction box at location.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 27 January 2016
Resolved
Vessel's line throwing gun did not have enough cartridges as required by Q-spec.
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 27 January 2016
Resolution: Vessel rep provided new cartridges while onboard
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 27 January 2016
Resolved
Electrical outlet was not mounted in refer.
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 27 January 2016
Resolution: Ship's crew made repairs while onboard
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 27 January 2016
Resolved
Vessel's starboard lifebuoy light was unoperable.
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 27 January 2016
Resolution: Ship's crew replaced the battery
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 27 January 2016
Resolved
Both generator overspeed devices were disconnected
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2016
Resolved 28 January 2016
Resolution: Tested Sat
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 27 January 2016
Resolved
Fuel leak on starboard main engine fuel line
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2016
Resolved 28 January 2016
Resolution: repaired
Electrical › Electrical Distribution System (service) › Switchboard
Issued 27 January 2016
Resolved
Switchboard interlock was nonoperatable
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2016
Resolved 28 January 2016
Resolution: installed on switchboard.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 January 2016
Resolved
Vessel's starboard OCM of OWS did not record history. Provide tech report prior to operation
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 17 March 2016
Resolution: Received documentation stating the starboard OCM and OWS was fully operational.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 January 2016
Resolved
Vessel's port OWS system was nonoperational. Provide tech report prior to operation
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 16 February 2016
Resolution: Vessel rep provided tech report from [name withheld] stating the Port OWS was fully operational
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 27 January 2016
Resolved
Remove oily rtags from forward bow thruster engine
Action required: 705 - Other - as specified
Due 27 January 2016
Resolved 28 January 2016
Resolution: repaired
Engineering › Bilge Water Management System › Manifold
Issued 27 January 2016
Resolved
Provide nameplates on all bilge pickup lines at the manifold
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 4 February 2016
Resolution: Received documentation from vessel rep showing the piping had been labeld
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 January 2016
Resolved
Provide covers on junction boxes in way of shafts
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 28 January 2016
Resolution: installed cover
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 27 January 2016
Resolved
Replace valve on GM Oil Tank
Action required: 705 - Other - as specified
Due 3 February 2016
Resolved 4 February 2016
Resolution: Received documentation from vessel rep showing the gate valve has been replaced.
Operations/Management › Drills/Instruction › Fire
Issued 27 January 2016
Resolved
Complete Man overboard, fire and abandon ship drills due to failure during inspection
Action required: 17 - Rectify deficiencies prior to departure
Due 27 January 2016
Resolved 28 January 2016
Resolution: completed