MAURY USCG vessel records Sign in
← All vessels

WESTERN TRITON IV

WESTERN TRITON IV is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 39 inspections since 1981, most recently in September 1993, along with 170 deficiencies.

Records from 1981 to 1993. Most recent: inspection, 7 September 1993.

Built
1979
Last inspected
7 September 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-52126

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (1981–1993)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4763 - Regulatory (Subpart C or D), Net Ton
4775 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

7 September 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 830341
21 April 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143804
28 January 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143910
17 December 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 829354
24 October 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436716
9 September 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942476
30 June 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255738
21 May 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950301
7 March 1992 Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1256651
16 November 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 939794
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899526
6 December 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239697
5 December 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 899503
21 November 1989 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 929540
12 July 1989 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038574
10 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038448
28 February 1989 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196232
21 February 1989 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042291
23 January 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202875
26 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019381
24 November 1987 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315244
19 May 1987 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1333121
29 April 1987 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1325486
17 February 1987 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1011666
30 December 1986 Deficiency Check · Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1005933
13 August 1986 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1024679
13 August 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1297969
28 May 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 984717
15 March 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995583
27 February 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 994812
26 November 1985 Credit Drydock · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 995772
21 March 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287455
7 February 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974290
26 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972554
13 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278623
9 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278719
21 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971676
14 November 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277144
19 November 1981 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969445

Deficiency record · 170

Lifesaving
Issued 24 October 1992 Resolved
PERSONS CAPACITY ON LIFEBOAT #2 IS REDUCED TO 45 PERSONS DUE TO "B" WEIGHT EXCEEDING DAVIT MAXIMUM WORKING WEIGHT BY 765LBS. CONTACT WHITAKER TO RESOLVE WITH NEW PLATE CERTIFYING WEIGHT OR OTHER DOCUMENTATION.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 24 October 1992 Resolved
PROVIDE ACTUATION CYLINDER FOR REMOTE ACTUATION OF MUD PIT CO2 SYSTEM AS NOTED ON SOTEC SERVICING REPORT.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #2: MILK (OR SUBSTITUTE PROVISIONS @ 1400 CALORIES/PERSON); REPAIR LATCH DOG ON PORT BOW DOOR; CHANGE FUEL.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Accommodation/Occupational Safety
Issued 24 October 1992 Resolved
REPLACE ALL BROKEN GLASS WINDOWS ON HOUSE.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992 Resolved
RESTENCIL #2 LIFEBOAT WITH PERSONS CAPACITY OF 45.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Engineering
Issued 24 October 1992 Resolved
PROVE PROPER OPERATION OF HIGH WATR TEMPERATURE ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 24 October 1992 Resolved
RESTENCIL ALL FIRE STATION NUMBERS, AS NEEDED, AND ALL GENERAL ALARM BELLS/LIGHTS AS NEEDED.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 24 October 1992 Resolved
REPAIR KEEPER CHAINS, AS NEEDED, ON FIRE NOZZLES.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Construction/Loadline
Issued 24 October 1992 Resolved
MAKE THROUGH DECK CABLE RUNS WATER/GAS TIGHT; LOCATED NEXT TO MUD TANKS IN SHAKER AREA.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Engineering
Issued 24 October 1992 Resolved
REPAIR WASTED CONTAINMENT IN F/O VENT #13.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Electrical
Issued 24 October 1992 Resolved
PUT LIGHTS FOR WATER LEVEL ILLUMINATION AT LIFERAFT STATIONS ON EMERGENCY CIRCUIT AND MARK AS SUCH.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Engineering
Issued 24 October 1992 Resolved
CONDUCT HYDRO ON FUEL TRANSFER HOSE AT 1.5 MAWP (MAX ALLOWABLE WORKING PRESSURE).
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992 Resolved
PROVIDE LIFERING SMOKE SIGNALS (PORT AND STBD).
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992 Resolved
PROVIDE FOLLOWING FOR LIFEBOAT #1: RENEW ALL PROVISIONS AND CONDENSED MILK,JACKKNIFE, CHANGE FUEL. REQUIRED CALORIES PER PERSON: PROVISIONS 3600; SUBSTITUTION OF PROVISIONS FOR MILK, 1400 CALORIES; TOTAL CALORIES PER PERSON, 5000.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 24 October 1992 Resolved
HYDROSTATICALLY TEST ALL SCBA (SELF CONTAINED BREATHING APPARATUS) BOTTLES AND SPARES.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Engineering
Issued 24 October 1992 Resolved
RENEW DEISEL FUEL HOSE AND PROVIDE DEAD MAN NOZZLE AT CEMENTING UNIT FUEL OIL TANK.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Construction/Loadline
Issued 24 October 1992 Resolved
RENEW SACK ROOM VENT HATCH COMBING AND GASKET, RENEW PL-15B HATCH COVER GASKET.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Accommodation/Occupational Safety
Issued 24 October 1992 Resolved
INSTALL ASME APPROVED RELIEF VALVES ON PORTABLE AND SANITARY WATER PRESSURETANKS SET AT NO MORE THAN 100 PSI.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 24 October 1992 Resolved
FOAM REELS - MAKE USABLE AND UPDATE FIRE SAFETY PLAN OR REMOVE.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Electrical
Issued 24 October 1992 Resolved
REPLACE BOLTS, IF NOT STRIPPED, IN EXPLOSION-PROOF BOX MOUNTED ON CRANE PEDISTAL NEXT TO CEMENT UNIT. IF STRIPPED, REPLACE BOX.
Condition: Unknown
Due 24 November 1992
Resolved 12 November 1992
Electrical
Issued 24 October 1992 Resolved
MOVE TWO (2) FLOODLIGHTS ON FWD SIDE OF DRILL FLOOR ABOVE FIVE (5) FEET FROM THE TOP OF WIND WALL.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Construction/Loadline
Issued 24 October 1992 Resolved
ENSURE ALL STUFFING TUBES/THRU BULKHEAD PENETRATIONS IN MUD PIT ROOM ARE CLOSED TIGHT.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992 Resolved
SERVICE HYDROSTATIC RELEASES ON ALL DAVIT LAUNCHED RAFTS.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Electrical
Issued 24 October 1992 Resolved
REPAIR OR REPLACE BUSTED MIXER MOTOR FAN HOUSING ON MIDDLE MIXER IN MUD PIT ROOM.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 7 March 1992 Resolved
THE FOLLOWING ITEMS ARE REQUIRED ON LIFEBOAT #1: HYDROSTATIC TEST OF RIGHTING BAG CO2 CYLINDER AND INSTALLATION OF PROPER CLIPS ON RIGHTING BAG CONTAINER._x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Documentation
Issued 7 March 1992 Resolved
PROVIDE LOADLINE CERTIFICATE WITH PROPER STABILITY LETTER DATE IN STABILITYENDORSEMENT ON CERTIFICATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Electrical
Issued 7 March 1992 Resolved
MAKE REPAIRS TO EXPLOSION PROOF LIGHTING FIXTURES OR REMOVE FROM VOID #31 UNDER MUDPITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Documentation
Issued 7 March 1992 Resolved
PROVIDE COPY OF UNDERWATER SURVEY VIDEO AND ABS SURVEY REPORT TO USCG MARINE SAFETY OFFICE NEW ORLEANS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Construction/Loadline
Issued 7 March 1992 Resolved
MAKE REPAIRS TO BROKEN SUPPORT UNDER PORT WALKWAY OVERHANG AT MAINDECK AND REPLACE WASTED UNDERDECK ANGLE SUPPORTS ON STBD WALKWAY OVERHANG AT MAINDECK._x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Fire Fighting
Issued 7 March 1992 Resolved
PROVIDE PROPER INSTRUCTIONS FOR PAINT LOCKER CO2 SYSTEM ACTUATION TO INCLUDE SHUTDOWN OF VENT BLOWER AND CLOSING VENT COVER. LABEL VENT FAN SHUTOFF SWITCH._x001C_ _x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Lifesaving
Issued 7 March 1992 Resolved
THE FOLLOWING ITEMS ARE REQUIRED ON LIFEBOAT #2: HYDROSTATIC TEST OF RIGHTING BAG CO2 CYLINDER, INSTALLATION OF PROPER CLIPS ON RIGHTING BAG CONTAINER, AND PROVIDE KILGORE GUN WITH PROPER NUMBER OF SHELLS OR EQUIVALENT SIGNALLING FLARES._x001C_
Condition: Unknown
Due 7 March 1992
Resolved 7 March 1992
Electrical
Issued 16 November 1991 Resolved
PROVIDE INTRENSICALLY SAFE RADIOS
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Fire Fighting
Issued 16 November 1991 Resolved
PROVIDE 2ND CO2 RELEASE (SIREN) ALARM FOR GENERATOR MOTOR ROOM
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Lifesaving
Issued 16 November 1991 Resolved
PROVIDE FOR NO.2 CAPSULE THE FOLLOWING:(A) FLASHLIGHT AND 6 BATTERIES (B) JACK KNIFE (C) HYDRO AIR BOTTLES.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Fire Fighting
Issued 16 November 1991 Resolved
REPLACE 13 OF 16 KINKED FLEX LOOPS ON CO2 FIXED SYSTEM.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Deck/Cargo
Issued 16 November 1991 Resolved
PROVE OPERATION OF ALL PRELOAD VALVES( DECK REMOTES) AND PROPERLY SECURE PACKING GLANDS TO DECK.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Deck/Cargo
Issued 16 November 1991 Resolved
TEST MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Deck/Cargo
Issued 16 November 1991 Resolved
CLEAN AND MAKE AVAILABLE FOR INTERNAL INSPECTION ALL (4) P-TANKS.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Lifesaving
Issued 16 November 1991 Resolved
INSTALL AND CONDUCT WEIGHT TEST IN PRESENCE OF COAST GUARD INSPECTOR, OF THE DAVIT LAUNCHED INF LIFERAFTS.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Lifesaving
Issued 16 November 1991 Resolved
PROVIDE FOR NO 1 CAPSULE THE FOLLOWING: (A) KILGORE GUN AND SHELLS (B) HYDRO AIR BOTTLES (C) REPAIR DAMAGED DOOR GASKET.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Accommodation/Occupational Safety
Issued 16 November 1991 Resolved
REPLACE BROKEN WINDOWS IN THE HOUSE FRONT
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Electrical
Issued 16 November 1991 Resolved
REPLACE BROKEN HOUSING ON PUMPS (PO SIGHTED)
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Electrical
Issued 16 November 1991 Resolved
LINE ALL BATTERY BOXES WITH LEAD
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Fire Fighting
Issued 16 November 1991 Resolved
REPAIR REPLACE INOPERATIVE SMOKE DETECTORS
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Documentation
Issued 16 November 1991 Resolved
PROVIDE THE FOLLOWING: (A) ANNUAL LOAD LINE ENDORSEMENT (B) STAMPED APPROVED BY USCG and ABS operation manual (REV 4) (C) STABILITY LETTER FOR REV 4 OF OPERATION MANUAL.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Lifesaving
Issued 16 November 1991 Resolved
PROVIDE DRINKING WATER FOR 50 X 3 QTS FOR STARBOARD CAPSULE.
Condition: Unknown
Due 16 November 1991
Resolved 16 November 1991
Lifesaving
Issued 21 November 1989 Resolved
PERFORM A FIRE AND BOAT DRILL.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Engineering
Issued 21 November 1989 Resolved
MAKE AVAILABLE FOR INSPECTION TESTING OF FOUR AIR RECEIVERS.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Lifesaving
Issued 21 November 1989 Resolved
PERFORM WEIGHT TESTS ON #1 & #2 LIFE CAPSULES.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Engineering
Issued 21 November 1989 Resolved
MAKE AVAILABLE FOR INSPECTION TESTING OF FOUR BULK TANKS.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Electrical
Issued 21 November 1989 Resolved
MAKE HAZARDOUS LOCATIONS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Construction/Loadline
Issued 21 November 1989 Resolved
PRESENT FOR INSPECTION THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Lifesaving
Issued 21 November 1989 Resolved
PROVIDE OCMI WITH COPIES OF LIFE RAFT SERVICE CERTIFICATES.
Condition: Unknown
Due 21 November 1989
Resolved 21 November 1989
Construction/Loadline
Issued 28 February 1989 Resolved
OBTAIN FROM MARATHON LETOURNEAU IN WRITING AN APPROVED PROCEDURE TO EFFECT PERMANENT REPAIRS TO CRACKING ON ALL LEG TO CAN CONNECTIONS ON ALL THREE LEGS. EFFECT THESE REPAIRS TO THE SATISFACTION OF THE ATTENDING INSPECTOR.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
CROP AND RENEW AS MARKED, INSERTING PLATE, THE SEVEN CRACKED AREAS BETWEEN THE MAIN DECK AND THE MAIN HOUSE AS FOLLOWS: FRAME 7 STARBOARD SIDE, FRAME9 PORT SIDE, AND FIVE(5) LOCATIONS AS MARKED ON FORWARD SIDE OF HOUSE. TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
RENEW ALL VENT COVER DOGS FOR BELOW DECK VENTILATION, ON BOTH GOOSENECK VENTS, STARBOARD SIDE FORWARD OF MAIN HOUSE.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Fire Fighting
Issued 28 February 1989 Resolved
RENEW/REPAIR AS NECESSARY BALL VALVE HANDLE ON HELO DECK FOAM FIREFIGHTING STATION.
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Construction/Loadline
Issued 28 February 1989 Resolved
FREE UP DOGS ON THE FOLLOWING WATERTIGHT DOORS; GALLEY STORES, CHANGE ROOM(STARBOARD SIDE).
Condition: Unknown
Due 28 February 1989
Resolved 28 February 1989
Unknown
Issued 21 February 1989 Resolved
PRIOR TO RELOCATING OR COMMENCING DRILLING OPERATIONS, CONDUCT SATISFACTORYSPECIAL EXAM IN LIEU OF DRYDOCKING OR DRYDOCK EXAM.
Condition: Unknown
Due 21 February 1989
Resolved 21 February 1989
Lifesaving
Issued 23 January 1989 Resolved
REPLACE 12 OUTDATED PARACHUTE FLARES LOCATED IN LINE THROWING GUN BOX
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Construction/Loadline
Issued 23 January 1989 Resolved
ADJUST WATERTIGHT DOOR LEADING FROM SICKBAY TO MAINDECK MIDBODY AREA
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Lifesaving
Issued 23 January 1989 Resolved
REPLACE OUTDATED VERRY PISTOL FLARES IN #1 LIFEBOAT CAPSULE
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Navigation
Issued 23 January 1989 Resolved
DEMONSTRATE PROPER OPERATION OF THE FOG SIGNAL
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Fire Fighting
Issued 23 January 1989 Resolved
REFILL SPARE SCBA CYLINDER FOR FIREMANS OUTFIT
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989
Deck/Cargo
Issued 24 November 1987 Resolved
REPAIR WASTED (HOLED) CONTAINMENT BASIN AROUND FUEL OIL VENT #14, MAIN DECK. 46 CFR 108.457
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Navigation
Issued 24 November 1987 Resolved
CLEAN, AND MAKE OPERABLE STERN NAVIGATION LIGHT (LOCATED AFT OF SHAKER AREA) 33 CFR 67.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Accommodation/Occupational Safety
Issued 24 November 1987 Resolved
PROVIDE CLEAN AND SUFFICIENT EYE WASH SOLUTION AND EQUIPMENT IN SHAKER AND MUD PIT AREAS. (EQUIPMENT IS DIRTY AND NEARLY EMPTY OF SOLUTION) 33 CFR 142.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987 Resolved
REPLACE MISSING HATCH BUMPERS TO HULL OF LIFEBOAT #2 (STBD SIDE) 46 CFR 108.507
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987 Resolved
BOTH LIFEBOATS TO BE STENCILED WITH THE INFORMATION REQUIRED IN 46 CFR 108.645 (STENCILING WORN AND INCOMPLETE)
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
REPLACE OR REPAIR WASTED WATER CANNON AND WASTED PIPING ON HOSE REEL LOCATED ON HELO DECK. ALSO THE TWO STATIONS THAT OPERATE OFF THE FOAM PUMP SHALL BE MARKED AS SUCH. 46 CFR 108.419
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
PROVIDE PROPER LENGTHS OF FIRE HOSE AT HYDRANT STATIONS PER FIRE CONTROL PLAN. SEVERAL DISCREPENCIES NOTED: SHAKER AREA, BOW AREA, ETC. 46 CFR 108.419
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
REPAIR LEAKING FIRE HYDRANT VALVE AT STATION #19, MAIN DECK, PORT SIDE. 46 CFR 108.419
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Engineering
Issued 24 November 1987 Resolved
DURING NEXT RIG MOVE, HAVE ALL PRESSURE VESSELS AND BULK TANKS OPEN FOR INTERNAL INSPECTION AND HAVE THEIR RESPECTIVE RELIEF VALVES AVAILABLE FOR BENCH TEST AT SET PRESSURE. 46 CFR 54.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
REVISE LIFE SAVING AND FIRE CONTROL PLAN (AND SUBMIT TO OUR OFFICE FOR APPROVAL) TO REFLECT CHANGES TO RIG'S SAFETY EQUIPMENT: FOAM TANK REMOVED,PAINT LOCKER LOCATION, REPLACEMENT OF D/C EXT'S WITH HALON 1211, ETC. 46 CFR 107.305
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Accommodation/Occupational Safety
Issued 24 November 1987 Resolved
PROVIDE NECESARY ARM AND LEG SPLINTS ON RIG. ALSO PROVIDE AMMONIA AMPULES (OR AROMATIC SPIRITS) IN RIG'S FIRST AIR SUPPLIES. 46 CFR 108.707
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987 Resolved
WEIGHT TEST OF PORT LIFEBOAT TO BE COMPLETED (AND WITNESSED BY CG INSPECTION) 46 CFR 109.217
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
CONDUCT FIRE AND BOAT DRILL IN PRESENCE OF CG INSPECTOR. 46 CFR 109.217
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Electrical
Issued 24 November 1987 Resolved
PRIOR TO SPUDDING IN, APPROPRIATELY WIRE TO MAKE INTRINSICALLY SAFE OR REMOVE "DIG1-GAS" PANEL FROM DRILL FLOOR. UNIT IS ALSO TO BE MOUNTED SECURELY AS WELL AS ITS JUNCTIONS AND SWITCHES. 46 CFR 111.80-5 OLD ELECTRICAL REGS SUBCHAPTER "J" 46 CFR 111.105
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Electrical
Issued 24 November 1987 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS AND TRIPS ON ROSS HILL SCR DRIVE SYSTEM. 46 CFR 111.12
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987 Resolved
CLEAN AND ADJUST CONTACTS ON MASTER SWITCHES OF BOTH LIFEBOATS. 46 CFR 108.507
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Electrical
Issued 24 November 1987 Resolved
APPROPRIATELY STUFF (PACK) LOWER EYS FITTING ON FAN MOTOR SWITH IN SHALE SHAKER. 46 CFR 111.105
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Documentation
Issued 24 November 1987 Resolved
PROVIDE ONBOARD (AND POST IN A CONSPICUOUS LOCATION) THE VESSELS USCG ISSUED STABILITY LETTER DATED 28APR83. 46 CFR 109.563.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Lifesaving
Issued 24 November 1987 Resolved
REPAIR ALL NECESSARY RING LIFE BUOYS: BUOY BY STBD BOAT HAS BROKEN STRAPS; WATER LIGHT SECURING LINES BROKEN, MISSING OR TOO SHORT ON MOST OTHER BUOYS46 CFR 108.515.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
REMOVE FOLLOWING COMPRESSED GAS BOTTLES FROM RIG (OR HAVE THEM HYDRO SERVICES) SCBA BOTTLE IN FIRE FIGHTING OUTFIT CONTAINER LOCATED OUTSIDE CONTROL ROOM. OXYGEN BOTTLE(S) IN SICK BAY. 49 CFR 175.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
STENCIL FIRE FIGHTING OUTFIT CONTAINER LOCATED OUTSIDE CONTROL ROOM. 46 CFR 108.497.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Fire Fighting
Issued 24 November 1987 Resolved
PROVIDE DRESS-OUT FIRE FIGHTING OUTFITS (VICE PROXIMITY SUITS) ONBOARD FOR FIRE OUTFIT CONTAINERS. 46 CFR 108.497.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Deck/Cargo
Issued 24 November 1987 Resolved
CRANES; REPAIR OR REPLACE SAFETY 'MOUSE' (LATCH) ON ALL CRANE HOOKS. ALSO MAKE VISIBLE FROM OPERATING STATIONS THE BOOM ANGLE INDICATORS (SOME NEED TO BE REPAINTED; OTHER NEEDS TO BE MOVED TO OTHER SIDE OF THE BOOM.) 46 CFR 108.601.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Construction/Loadline
Issued 24 November 1987 Resolved
REPAIR BROKEN OR MISSING DOGS ON PAINT LOCKER VENT CLOSURE AND ON HATCH COVER TO PUMP ROOM EXHAUST VENT, PORT SIDE. 46 CFR 108.113.
Condition: Unknown
Due 24 November 1987
Resolved 24 November 1987
Electrical
Issued 29 April 1987 Resolved
REPAIR CHECKO IN ELECTRICAL FITTIN FOR HORN IN MUD PIT ROOM
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Electrical
Issued 29 April 1987 Resolved
REPAIR VARIOUS INOP E LIGHTS
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987 Resolved
3 STUFFING TUBES IN MUD PIT ROOM TO BE PLUGGED
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987 Resolved
MAKE REPAIR TO DOOR CLOSER IN MUD PIT ROOM
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 30 December 1986 Resolved
REDUCE TH MAXIMUM ALLOWED PERSONS ON BOARD TO 85 UNTIL ITEM #1 IS COMPLETED
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 30 December 1986 Resolved
REPLACE MISSING 20 MAN LIFERAFT.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 30 December 1986 Resolved
REMOVE TEMPORARILY INSTALLED 54 MAN LIFECAPSULE AND INSTALL APPROVED 50 MANLIFE CAPSULE ON THE STARBOARD SIDE.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Lifesaving
Issued 30 December 1986 Resolved
EMBARK NO MORE THAN 46 PERSONS ABOARD THE STARBOARD LIFE CAPSULE.
Condition: Unknown
Due 30 December 1986
Resolved 30 December 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACK OVER 3/4'S OF THE FLAT T-BAR TO CHORD WELD OF THE BOW LEG CHORD 1.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE SMALL VERTICAL GUSSET CONNECTING THE SPUD CANTO CHORD 1 OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE TWO INCH CRACK IN THE LOWER VERTICAL WELD SCALLOP OF CHORD 1A OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS ON THE ENDS OF THE FLAT T-BAR PLATE TORACK WELD OF CHORD 2 OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE TWO INCH CRACK ON THE LOWER VERTICLE WELD SCALLOP OF CHORD 2B OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR TO RACK WELD OF CHORD 3 OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACK IN THE SMALLER VERTICAL GUSSET PLATE TOSPUD CAN CONNECTION OF CHORD 3A OF THE BOW LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACK OVER 3/4'S OF THE FLAT T-BAR PLATE TO RACK WELD OF CHORD 1 OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE TWO INCH CRACK ON THE SMALL VERTICLE GUSSET PLATE TO CAN CONNECTION OF CHORD 1A OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR PLATE TORACK WELD OF CHORD 3 OF THE PORT LEG
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE INBOARD END CRACK OF THE SMALLER VERTICAL GUSSET PLATE TO SPUD CAN WELD OF CHORD 2A OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE 3/4 INCH CRACK IN THE SIDE OF THE SMALLER VERTICLE GUSSET PLATE TO SPUD CAN CONNECTION OF CHORD 2A OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR PLATE TORACK WELD OF CHORD 1 OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE ONE INCH CRACK IN THE LOWER VERTICLE WELD SCALLOP OF CHORD 1B OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE ONE INCH CRACK IN THE LOWER VERTICAL WELD SCALLOP OF CHORD 2B OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR PLATE TORACK WELD OF CHORD 2 OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS ON BOTH SIDES OF THE SMALLER VERTICAL GUSSET PLATE TO SPUD CAN WELD ON CHORD 3 OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR PLATE TOTHE RACK OF CHORD 2 OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE TWO INCH CRACK IN THE LOWER VERTICLE WELD SCALLOP OF CHORD 2B OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKS IN THE ENDS OF THE FLAT T-BAR TO RACK WELD OF CHORD 3 OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO THE CRACK IN THE INBOARD END OF THE SMALLER VERTICLE GUSSET PLATE TO SPUD CAN CONNECTION OF CHORD 3 OF THE STARBOARD LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986 Resolved
MAKE PERMANENT REPAIRS TO SMALLER VERTICLE GUSSET PLATE WHICH IS BROKEN FREE FROM THE SPUD CAN OF CHORD 1 OF THE PORT LEG.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
REPLACE THE FORWARD BULKHEAD INNER GALLEY DOOR
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
PLACE DIVIDER (PRIVACY) SCREENS BETWEEN THE TOILETS AND URINALS IN EACH OF THE TWO CHANGING ROOMS
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Unknown
Issued 26 November 1985 Resolved
PROVIDE FOR AN INTERNAL EXAMINATION BY A COAST GUARD MARINE INSPECTOR ALL FOUR BULK CHEMICAL TANKS AT THE COMPLETION OF THIS DRILLING OPERATION BUT IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
REPAIR IN KIND THE FOLLOWING PRELOAD DUMP VALVES: (1) THE 3 INCH CRACK IN THE SEAT ON #4; (2) THE GOUGE ACROSS THE FACE OF THE SEAT ON #15A.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Fire Fighting
Issued 26 November 1985 Resolved
REPLACE OR CONVERT THE FOUR SELF-CONTAINED BREATHING APARATUS (SCBA) FROM DEMAND UNITS TO PRESSURE/DEMAND (POSITIVE PRESSURE) UNITS.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Fire Fighting
Issued 26 November 1985 Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST OF THE SIX SCBA AIR CYLINDERS
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Accommodation/Occupational Safety
Issued 26 November 1985 Resolved
ADJUST FOR PROPER CLOSURE OR REPLACE THE INNER DOOR TO THE WEATHER ENTRANCETO THE UPPER LEVEL CHANGING ROOM
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Fire Fighting
Issued 26 November 1985 Resolved
UPON COMPLETION OF THE ANNUAL SERVICING OF THE PORTABLE FIRE EXTINGUISHERS ON BOARD THE VESSEL SUBMIT A COPY OF THE REPORT TO THE COGNIZANT [name withheld] GUARD.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION BY A USCG MARINE INSPECTOR VOID #31 AND THE ASSOCIATED MUD PIT DUMP VALVES IN VOID #31 NO LATER THAN THE COMPLETION OF DRILLING OPERATIONS AND IN NO CASE LATER THAN 26FEB86
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Construction/Loadline
Issued 26 November 1985 Resolved
COMPLETE THE UNDERWATER EXAMINATION OF THE SPUD CANS AND THE ASSOCIATED NON-DESTRUCTIVE TESTING (NDT) OF THE LEG TO SPUD CAN CONNECTIONS IN THE PRESENCE OF A USCG MARINE INSPECTOR AT THE NEXT RIG MOVE AND IN NO CASE LATER THAN 26FEB86.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Electrical
Issued 26 November 1985 Resolved
REPAIR THE PURGE ALARM INDICATOR ON THE GEODRIL BIT SENTRY UNIT ON THE DRILL FLOOR.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Fire Fighting
Issued 26 November 1985 Resolved
INSTALL ONE B-II EXTINGUISHER IN EACH OF THE THREE CRANES.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Deck/Cargo
Issued 26 November 1985 Resolved
CONDUCT AN ANNUAL CRANE SURVEY ON EACH OF THE THREE CRANES.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Electrical
Issued 26 November 1985 Resolved
INSTALL A PROPER SIZE JUNCTION BOX ON THE POWER SUPPLY FOR EACH OF THE SIX (6) MOTOR GENERATOR SETS FOR THE CRANES.
Condition: Unknown
Due 26 November 1985
Resolved 26 November 1985
Electrical
Issued 7 February 1985 Resolved
PROPERLY SECURE THE ELECTRICAL WIRES ON THE STARBOARD SIDE OF THE FORWARD MAIN DECK BY THE P-TANK ROOM.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
POUR NEW EYS INSTALLATIONS THROUGHOUT THE RIG.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
LABLE ALL FIVE (5) LIFERAFT STATIONS.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Construction/Loadline
Issued 7 February 1985 Resolved
CLEAN PAINT OFF THE KNIFE EDGE AND GASKET ON THE PAINT LOCKER WATERTIGHT DOOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
REPLACE THE MISSING EQUIPMENT IN THE FIRST AID KIT.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
LABEL THE GENERAL ALARM LIGHT IN THE MUD PUMP ROOM.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Construction/Loadline
Issued 7 February 1985 Resolved
ADJUST BOTH DOORS TO THE MUD PITS.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
INSTALL A BACK UP ALARM ON THE FORK LIFT.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Unknown
Issued 7 February 1985 Resolved
TEST THE RELIEF VALVES ON ALL THE RIG PRESSURE VESSELS LISTED ON THE CERTIFICATE OF INSPECTION IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Documentation
Issued 7 February 1985 Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR THE RIG.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
TEST THE GENERAL ALARM SWITCHES, BELLS AND LIGHTS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
LABEL ALL EMERGENCY LIGHTING THROUGHOUT THE RIG.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
PROVIDE TWO (2) SERVICE LINES FOR THE LINE THROWING GUN.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
REPAIR BOTH OXYGEN METERS.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
REPLACE THE EXPENDED SMOKE CANISTER ON THE PORT LIFE RING.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985 Resolved
STENCIL THE FIRE AXES WITH THE RIG NAME.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
REMOVE DOOR LOCK HASPS ON ALL THE ACCESS DOORS.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Lifesaving
Issued 7 February 1985 Resolved
PROVIDE A SECOND MEANS OF ESCAPE FROM THE HELIPORT.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Fire Fighting
Issued 7 February 1985 Resolved
PROVIDE PROOF OF SERVICING OF THE FIRE EXTINGUISHER.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Construction/Loadline
Issued 7 February 1985 Resolved
REMOVE PAINT FROM THE KNIFE EDGES, DOGS, AND DOG SHOES ON ALL WATERTIGHT DOORS AND HATCHES.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
REPLACE THE DUMP CYCLE SWITCH ON THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
REPAIR THE AIR PURGE ALARM ON THE DRILL FLOOR LOGGING UNIT, TRIP TANK SYSTEM, MUD MONITOR, AND GAS DETECTOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Electrical
Issued 7 February 1985 Resolved
REPAIR THE STARBOARD BUG BLOWER CONTROLLER ON THE DRILL FLOOR.
Condition: Unknown
Due 7 February 1985
Resolved 7 February 1985
Construction/Loadline
Issued 13 January 1984 Resolved
MAKE PERMANENT REPAIRS TO THE FRAME IN PRELOAD TANK 15B THAT IS CRACKED AT THE TEN FOOT LEVEL ABOVE THE TANK BOTTOM. FRAME 21 OR 22. THE REPAIR IS T0
Condition: Unknown
Due 13 January 1984
Resolved 13 January 1984
Unknown
Issued 13 January 1984 Resolved
(CONTINUE FROM D1) BE COMPLETED TO THE SATISFACTION OF THE OFFICER IN CHARGE MARINE INSPECTION NEW ORLEANS-46 CFR 107.275
Condition: Unknown
Due 13 January 1984
Resolved 13 January 1984
Unknown
Issued 21 November 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE WESTERN TRITON IV, DN614074.
Condition: Unknown
Due 21 November 1983
Resolved 21 November 1983
Unknown
Issued 21 November 1983 Resolved
MAKE PERMANENT REPAIRS TO OVERHANG ON MAIN DECK, AFT PORTSIDE JUST FORWARD OF PORT LEG.
Condition: Unknown
Due 21 November 1983
Resolved 21 November 1983
Unknown
Issued 21 November 1983 Resolved
REMOVE SEA VALVES BELOW THE VESSEL'S REGISTERED LOADLINE AND MAKE THOSE ANDTHEIR CHECK VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 30 March 1984
Resolved 21 November 1983
Unknown
Issued 21 November 1983 Resolved
MAKE ALL PRELOAD AND DRILL WATER TANK AND VOIDS AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 21 November 1983
Resolved 21 November 1983
Unknown
Issued 14 November 1983 Resolved
INSTALL AND MAKE OPERATIVE 2 RIG SHUTDOWN SWITCHES.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
REPAIR THE PURGE ALARM ON THE DRILLER'S CONSOLE.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
OBTAIN AND POST THE COAST GUARD APPROVAL TAG AND MANUFACTURER'S OPERATING INSTRUCTIONS ON THE MARINE SANITATION DEVICE.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE WESTERN TRITON IV, DN614074.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
PROVIDE ONE SEA ANCHOR FOR EACH LIFE CAPSULE AS REQUIRED BY 46 CFR 108.503(D).
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
CONDUCT A DRYDOCK EXAMINATION OR A SPECIAL EXAMINATION AS REQUIRED BY 46 CFR 107.267.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
REPAIR THE RELIEF VALVES ON THE #2 RIG AIR RECEIVER (MACHINE SHOP), THE #1 AND #2 RIG AIR COMPRESSOR SURGE TANKS (COMPRESSOR ROOM), THE RIG AIR
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983
Unknown
Issued 14 November 1983 Resolved
(4 CONT.) RECEIVER UNDER THE DRILL FLOOR, THE #1 - #4 P-TANKS (ON DECK), THE SANITARY WATER TANK, AND THE FIRE MAIN BOOSTER PUMP.
Condition: Unknown
Due 14 November 1983
Resolved 14 November 1983

Ownership record