MAURY USCG vessel records Sign in
← All vessels

BENTHIC LADY

BENTHIC LADY is a 1980 commercial fishing vessel. The Coast Guard has recorded 75 inspections since 1982, most recently in December 2011, along with 121 deficiencies and 1 casualty investigation in 2013.

Records from 1982 to 2013. Most recent: casualty investigation, 10 August 2013.

Built
1980
Last inspected
5 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD9020
Flag
UNITED STATES
367305930, 367585750 (licence lapsed)
Maury page id
psix-52130

Inspections, by type

…with no type recorded25
Years with a record 27 calendar years (1982–2011)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
90 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG9235MMSI 367585750 · expired · compulsorily equipped · granted 2 August 2013, cancelled 7 October 2023
WDD9020MMSI 367305930 · expired · compulsorily equipped · granted 1 August 2007, cancelled 7 October 2017 · licensed under a name not among this hull’s recorded names (not shown)
WCW2757MMSI not assigned · expired · compulsorily equipped · granted 5 March 1996, cancelled 6 May 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 75

5 December 2011 Re-Inspection · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200076
15 November 2010 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3890100
29 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3385826
25 August 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3308466
20 September 2007 COI Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3062087
6 September 2007 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3055185
6 June 2007 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2951510
1 March 2007 Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2879982
30 May 2006 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2732909
27 February 2006 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2592914
10 June 2005 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2386538
17 May 2005 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2360659
25 April 2005 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2344302
4 October 2004 Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2213065
14 June 2004 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2098578
22 April 2004 Hull Examination
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 2053341
18 April 2003 Re-Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1776163
29 July 2002 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1653760
14 June 2002 Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1631239
11 June 2002 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 1629485
1 February 2002 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1606493
14 August 2001 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 772177
14 August 2001 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1395803
16 March 2001 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1386995
5 March 2001 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 445370
5 March 2001 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 535811
5 June 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 818498
12 May 2000 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 51973
8 May 2000 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 106560
4 May 2000 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1446918
13 January 2000 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1372892
9 December 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1418633
25 May 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400991
25 March 1999 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1390983
22 February 1998 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 810810
3 February 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 675882
25 September 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 71385
25 February 1997 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1368183
7 January 1997 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 199166
7 January 1997 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 761322
22 July 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1431656
21 February 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1371442
24 May 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1374438
22 March 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 879075
27 February 1995 Deficiency Check · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1407531
22 October 1994 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1354980
5 October 1994 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 862459
23 August 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 673497
18 July 1994 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1385269
12 July 1994 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 866117
29 June 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 867208
28 June 1994 Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1367105
24 June 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 40745
24 June 1994 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 89902
2 June 1994 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 675883
27 May 1994 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 149273
2 March 1994 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1389775
3 December 1993 Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 20111
7 June 1993 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1143346
26 February 1993 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1362787
23 February 1993 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1146736
8 April 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 946623
18 February 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1258054
18 September 1991 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1252073
15 July 1991 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 936686
6 February 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 906406
4 October 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901452
27 July 1989 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1197508
29 December 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007592
25 September 1986 Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319074
22 November 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989970
24 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284926
6 August 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 973689
15 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283439
18 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277740

Deficiency record · 121

Lifesaving › Hand Flares › Expired
Issued 5 December 2011 Resolved
Expired / wrong type flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2012
Resolution: Renewed expired flares.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 December 2011 Resolved
Renew port escape E-light in eng-room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2012
Resolution: Renewed emergency lighting in eng room.
Communications › Radio Communications › EPIRB
Issued 5 December 2011 Resolved
Expired hydrostatic release.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 January 2012
Resolution: Renewed hydro release.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 5 December 2011 Resolved
Renew 07 bridge windows due to cracks.
Action required: 705 - Other - as specified
Resolved 3 January 2012
Resolution: Renewed 07 bridge windows.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 November 2010 Resolved
Renew expired alcohol test strips.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 29 November 2010
Communications › Public Address System › Loudspeaker
Issued 15 November 2010 Resolved
Provide additional speakers for public address system, can not be heard on mess deck.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 29 November 2010
Fire Fighting › Remote Fuel Shutoff › General
Issued 15 November 2010 Resolved
Renew port fuel reach rod.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 November 2010 Resolved
Provide new/updated compass deviation card, current card is completely faded.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Lifesaving › Lifefloat › Serviceable
Issued 15 November 2010 Resolved
Remove badly worn lifefloat from vessel, vessel has enogh good lifefloats on board to satisfy COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Engineering › Pressure Vessel › Pressure Gauge
Issued 15 November 2010 Resolved
Renew broken gauges and painted relief valves on both air receivers in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 15 November 2010 Resolved
Renew overspeed devices on both generators
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 November 2010
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 August 2008 Resolved
Label remote fuel shutoffs on main deck.
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 25 August 2008
Engineering › Compressed Air System (start air) › Valve
Issued 25 August 2008 Resolved
Renew air receiver relief valve.
Action required: 705 - Other - as specified
Due 25 September 2008
Resolved 25 August 2008
Lifesaving › Lifefloat › Float-free Link
Issued 25 August 2008 Resolved
Renew float free link on life floats.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 August 2008
Resolved 25 August 2008
Deck/Cargo › Cargo Transfer (solid) › General
Issued 20 September 2007 Resolved
Deck crane cabling was frayed and not properly secured.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 20 September 2007 Resolved
All ball vents on tanks were not properly maintained. Most were plugged, missing flame screens and balls. see attached pictures.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: New vents installed.
Engineering › Steering Gear System › Hydraulic Hose
Issued 20 September 2007 Resolved
Deteriorated and leaking.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: New hoses installed.
Engineering › Steering Gear System › Piping
Issued 20 September 2007 Resolved
Piping on back deck badly wasted.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: New piping installed.
Engineering › Steering Gear System › Ram Seal
Issued 20 September 2007 Resolved
Leaking.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: Rams rebuilt.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 September 2007 Resolved
Insufficient number.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Construction/Loadline › Structures › Superstructure
Issued 20 September 2007 Resolved
Furniture attached to tonnage openings. Must be removed.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Engineering › Compressed Air System (start air) › Valve
Issued 20 September 2007 Resolved
Improper relief valves.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Resolution: New valves installed.
Engineering › Fuel Oil Service System › Valve, Control
Issued 20 September 2007 Resolved
Fuel shut off valves frozen and reach rods broken.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 20 September 2007 Resolved
Not working.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 20 September 2007 Resolved
Unapproved fuel system hoses on main diesel engines and generators.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Engineering › Fuel Oil Service System › Gauge
Issued 20 September 2007 Resolved
Sight gauges on fuel tanks within engine room were unprotected, plastic and shut off valves did not have automatic stopping device installed. Install protective device, Pyrex high temp glass and correct valves as required.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 20 September 2007 Resolved
Missing gaskets on engine room vent covers and no means of securing.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 20 September 2007 Resolved
Missing extinguisher as per COI.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 20 September 2007 Resolved
Missing.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 20 September 2007 Resolved
Inaccurate. Must be redone.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Electrical › Electric Supply System (service) › Cable
Issued 20 September 2007 Resolved
Improper, loose, open and dead end cables on MDE's and throughout engine room.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 September 2007 Resolved
Exposed piping. Wrap all exhaust piping as needed.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Fire Fighting › Nozzles › Condition
Issued 20 September 2007 Resolved
Frozen and needing maintenance or replacement.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 September 2007 Resolved
Provide up to date charts and proper area for placement and use.
Action required: 705 - Other - as specified
Resolved 27 September 2007
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
Renew all watertight gaskets in all watertight doors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
C/R wasted steel around port bridge door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
C/R wasted steel around port deck emergency exit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Stability › Watertight Integrity › General
Issued 6 September 2007 Resolved
Renew wasted steel around WTD at E/R ventalation duct and adjust door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 September 2007 Resolved
Place blanks in all open panalboard positions.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Electrical › Electrical Distribution System (service) › Panelboard
Issued 6 September 2007 Resolved
Label all electrical panal boxes
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Lifesaving › Rescue Boat › Carriage Requirement
Issued 6 September 2007 Resolved
Install rescue boat and davit or rescue platform IAW D8 policy ltr.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 6 September 2007 Resolved
Install emergency lighting in machinery spaces IAW 46 CFR 112.15-1(c) under OLD I
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Communications › Alarms/Indicators › General Alarm
Issued 4 June 2007 Resolved
Repair engine room audible general alarm.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2007
Resolved 27 September 2007
Deck/Cargo › Marine Portable Tanks › Tank Shell
Issued 4 June 2007 Resolved
Conduct required hydro testing prior to using both tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2007
Resolution: No longer on board vessel.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 4 June 2007 Resolved
Conduct required testing and marking of transfer hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 September 2007
Resolution: No longer on board vessel.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 February 2006 Resolved
Prove proper operation of fuel oil transfer pump emergency shut down.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2006
Resolved 15 March 2006
Resolution: Conducted operational test of shut down satisfactorily.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 27 February 2006 Resolved
Replace flame safety screens on goose neck vents.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2006
Resolved 15 March 2006
Resolution: New flame screens installed.
Lifesaving › Immersion Suits › General
Issued 27 February 2006 Resolved
Replace inflation tube one-way valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Resolution: New tube purchased.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 27 February 2006 Resolved
Replace 2 old life jackets
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2006
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 February 2006 Resolved
Mark engine room emergency escapes.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 15 March 2006
Resolution: Glow in the dark exit signs and directional arows installed at both engine room emergency exits.
Construction/Loadline › Structures › Superstructure
Issued 27 February 2006 Resolved
Make aft deck door seal properly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 April 2006
Resolved 15 March 2006
Resolution: New hinges installed. Door seals properly.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 April 2005 Resolved
Three ships service lights were missing either globes or guards, two in engineroom, one on weather deck, starboard side in the vicinity of the liferaft.
Condition: Unknown
Due 30 May 2005
Resolved 10 June 2005
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 25 April 2005 Resolved
Vessel was missing signs at the gangway required during transfer to or from marine portable tanks per 46 CFR 98.30-35
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2005
Resolved 10 June 2005
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 April 2005 Resolved
Make air receivers available for inspection. 46 CFR 61.10
Action required: 705 - Other - as specified
Due 30 April 2005
Resolved 10 June 2005
Engineering › Steering Gear System
Issued 18 April 2003 Resolved
Rudder angle indicator on aft steering station inoperable. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Unknown
Due 22 May 2003
Resolved 30 May 2003
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 18 April 2003 Resolved
O/O claimed he misunderstood COI amendment requiring 25 gallons of AFFF foam and ordered 15 gallons instead. Inspector required purchase of 2 additional five gallon containers of foam. LEGACY COMPONENT DESC: Quantity of Foam
Condition: Improper Installation
Due 22 May 2003
Resolved 30 May 2003
Navigation › Piloting/Steering
Issued 18 April 2003 Resolved
Missing current light list LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 22 May 2003
Resolved 30 May 2003
Deck/Cargo › Cargo Transfer (solid)
Issued 18 April 2003 Resolved
Provide proof of annual testing of cargo crane LEGACY COMPONENT DESC: crane
Due 22 May 2003
Resolved 30 May 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 29 July 2002 Resolved
Vessel has no light list on board. 2002 light list not yet available.
Due 28 August 2002
Resolved 6 January 2003
Stability › Watertight Integrity
Issued 29 July 2002 Resolved
Incorrect size gasket was placed on hatches. LEGACY COMPONENT DESC: engine room escape trunks
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 July 2002
Resolution: verified new gasket material in place.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 29 July 2002 Resolved
draft marks were worn and not painted a contrasting color.
Condition: Unknown
Due 28 August 2002
Resolved 2 September 2002
Fire Fighting › Portable Foam Applicators › General
Issued 1 February 2002 Resolved
O/O WILL BE PROVIDING UNIT AT NEXT ANNUAL EXAM.
Due 1 June 2002
Resolved 1 April 2003
Resolution: Portable foam applicator on board.
Construction/Loadline
Issued 16 March 2001 Resolved
REPAIR OR REPLACE MAINDECK WATERTIGHT DOOR AT GALLEY DUE TO WASTAGE. COMPLETE BY NEXT DRYDOCK, NO LATER THAN 22JUL01.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Navigation
Issued 4 May 2000 Resolved
REPAIR STEERING ALARM SYSTEM.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Navigation
Issued 4 May 2000 Resolved
PROVE PROPER OPERATION OF FOLLOW-UP STEERING SYSTEM.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Deck/Cargo
Issued 4 May 2000 Resolved
COMPLETE HYDRO & RELIEF VALVE TEST ON PORT MPT PRIOR TO USING IT.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Fire Fighting
Issued 4 May 2000 Resolved
PROVE SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 May 2000
Resolved 4 May 2000
Construction/Loadline
Issued 13 January 2000 Resolved
GAUGE ALL SIDESHELL FRAMES IN FOREPEAK AND MAKE REPAIRS AS NECESSARY.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 13 January 2000 Resolved
PROVIDE PROPOSAL AND COMPLETE REPAIR ON MIDTANK LONGITUDINAL AT FWD BULKHEAD OF STARBOARD FWD BALLAST TANK WHERE SLUG WELD CURRENTLY IS.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 13 January 2000 Resolved
MAKE PERMANENT REPAIRS TO REACH ROD FOR FOREPEAK BALLAST SUCTION.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 13 January 2000 Resolved
CROP AND RENEW PORT AFT DECK LONG AND BRACKET AT HATCH IN FOREPEAK.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 13 January 2000 Resolved
RENEW BRACKET ON STEM AT COLLISSION BULKHEAD IN FOREPEAK BALLAST TANK. MAKEAREA AVAILABLE FOR FURTHER INSPECTION AND POSSIBLE GAUGING.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 13 January 2000 Resolved
MAKE ENGINEROOM BILGE AVAILABLE TO INSPECT.
Condition: Unknown
Due 15 March 2000
Resolved 17 March 2000
Construction/Loadline
Issued 9 December 1999 Resolved
MAKE VESSEL AVAILABLE FOR INTERNAL STRUCTURAL EXAM. PROVIDE NO LATER THAN 09JAN00.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Deck/Cargo
Issued 25 March 1999 Resolved
obtain new cargo hoses and provide testing info.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Electrical
Issued 25 March 1999 Resolved
Prepare both SSDG's for inspection.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Construction/Loadline
Issued 25 March 1999 Resolved
Make watertight port engineroom scuttle and test it.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Engineering
Issued 25 March 1999 Resolved
Restencil valve nanes on aft deck.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Electrical
Issued 25 March 1999 Resolved
Repair frequency meter on main switchboard.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Deck/Cargo
Issued 25 March 1999 Resolved
Repair flame screens on fuel and cargo tank vents.
Condition: Unknown
Due 29 April 1999
Resolved 20 April 1999
Electrical
Issued 25 March 1999 Resolved
repair circuit breaker box cover aft of main switchboard.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Deck/Cargo
Issued 25 March 1999 Resolved
stencil SWL on crane base.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Fire Fighting
Issued 25 March 1999 Resolved
Repair vent covers to engineroom.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Deck/Cargo
Issued 25 March 1999 Resolved
Obtain plugs for all fuel containments.
Condition: Unknown
Due 29 April 1999
Resolved 20 April 1999
Unknown
Issued 25 February 1997 Resolved
Air reciever safeties not calibrated properly.
Condition: Unknown
Due 25 March 1997
Resolved 18 June 1997
Lifesaving
Issued 21 February 1996 Resolved
PROVIDE INTRINSICALLY SAFE RADIOS FOR TRANSFER OPS.
Condition: Unknown
Due 21 February 1996
Resolved 21 February 1996
Documentation
Issued 22 March 1995 Resolved
SHOW PROOF OF SUBMITTAL OF VESSEL RESPONSE PLAN TO COMMANDANT- GMEP.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Deck/Cargo
Issued 22 March 1995 Resolved
MAKE AVAILABLE FOR INSPECTION ALL EQUIPMENT THAT WILL BE LISTED IN VESSEL RESPONSE PLAN.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Deck/Cargo
Issued 27 February 1995 Resolved
PROPERLY MARK TRANSFER HOSES.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Deck/Cargo
Issued 27 February 1995 Resolved
PROVIDE PROOF CARGO HOSES HAVE BEEN TESTED TO 1 1/2 TIMES WORKING PRESSURE._x001C_
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Deck/Cargo
Issued 27 February 1995 Resolved
CLEAN OR REPLACE FLAME SCREENS.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Deck/Cargo
Issued 27 February 1995 Resolved
PROVIDE PROOF CARGO HOSES ARE APPROVED TYPE OR REPLACE WITH APPROVED.
Condition: Unknown
Due 27 February 1995
Resolved 27 February 1995
Documentation
Issued 27 February 1995 Resolved
PROVIDE COMPLETED DRUG TESTING PROGRAM.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Electrical
Issued 27 February 1995 Resolved
COMPLETE SUPPORT OF ELECTRICAL WIRES AND RUNS.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Lifesaving
Issued 27 February 1995 Resolved
REPLACE BLUE COVER FOR FLASHING GENERAL ALARM IN ENGINE ROOM WITH RED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Construction/Loadline
Issued 27 February 1995 Resolved
REPAIR/REPLACE DOGS FOR HATCH AFT SIDE OF HOUSE.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Navigation
Issued 27 February 1995 Resolved
PROVIDE CURRENT MAGNETIC COMPASS DEVIATION CARD._x001C_
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Deck/Cargo
Issued 27 February 1995 Resolved
PROVIDE PROOF OF TESTING OF CARGO GEAR PRIOR TO EXPIRATION OF CURRENT DOC._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Engineering
Issued 27 February 1995 Resolved
MAKE AVAILABLE FOR INSPECTION STARBOARD AIR COMPRESSOR.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Accommodation/Occupational Safety
Issued 27 February 1995 Resolved
COMPLETE COATING OF POTABLE WATER TANKS.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Deck/Cargo
Issued 27 February 1995 Resolved
PROVE PROPER OPERATION OF P/V VALVES ON PORTABLE TANK.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Deck/Cargo
Issued 27 February 1995 Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION OR PROVIDE TESTING REPORT FOR PORTABLE CARGO TANKS._x001C_
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Engineering
Issued 5 October 1994 Resolved
REPAIR TO MAKE OPERABLE THE REACH ROD FOR THE VALVE FOR THE BILGE SUCTION IN THE FORWARD PEAK TANK. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL UNDERWAY.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
PROPERLY SURRORT AND GUARD THE LIGHT AT THE WORK BENCH.
Condition: Unknown
Due 6 October 1994
Resolved 6 October 1994
Construction/Loadline
Issued 5 October 1994 Resolved
REPAIR/REPLACE THE KNIFE EDGE (GASKET CHANNEL) FOR THE AFTER BALLAST TANKS AND AFTER VOIDS.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Deck/Cargo
Issued 5 October 1994 Resolved
LOWER THE ANCHOR TO FACILITATE INSPECTION OF THE CHAIN AND CABLE. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Construction/Loadline
Issued 5 October 1994 Resolved
REWELD FRACTURES AS MARKED AND CROP AND RENEW VERTICAL STIFFNERS AS MARKED IN THE NO. 1 PORT AND STARBOARD BALLAST TANKS. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
REPLACE THE WIRING FOR THE LIGHT IN THE FORWARD PEAK VOID. THE ELECTRICAL CIRCUIT FOR THIS SYSTEM IS TO BE DE-ENERGIZED AND REMAIN SO UNTIL THE WIRING HAS BEEN REPLACED.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Construction/Loadline
Issued 5 October 1994 Resolved
REPLACE UNDERDECK FASTENERS (U-LOCKS) FOR COVERS ON THE AFTER BALLAST TANKSAND VOIDS. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
PLACE THE DEADENDED 220V SYSTEM ON THE STBD SIDE OF THE ENGINEROOM IN A JUNCTION BOX. THIS CIRCUIT IS TO BE DE-ENERGIZED UNTIL SUCH TIME THIS ITEMHAS BEEN COMPLETED.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Construction/Loadline
Issued 5 October 1994 Resolved
REPLACE EMERGENCY ESCAPE HATCH ON THE STBD SIDE OF THE ENGINEROOM.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 5 October 1994 Resolved
THROUGHOUT THE ELECTRICAL SYSTEM, ESPECIALLY IN THE ENGINE ROOM, ELECTRICL WIRING AND WIRE RUNS HAVE BEEN SUPPORTED AND RETAINED USING NYLON TIE STRAPS, THESE STRAPS ARE TO BE REPLACED USING ACCEPTABLE STRAPS.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Engineering
Issued 5 October 1994 Resolved
EXTEND THE SHAFT GUARDS FOR THE TAILSHAFTS TO COVER THE MAIN ENGINE COUPLINGS.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Accommodation/Occupational Safety
Issued 5 October 1994 Resolved
CLEAN AND COAT THE POTABLE WATER TANKS USING APPROVED COATINGS. THIS ITEM IS TO BE COMPLETED PRIOR TO PLACING THE VESSEL INTO SERVICE.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Engineering
Issued 28 June 1994 Resolved
VESSEL SHALL RELOCATE APPROX 2,000 GALLONS FUEL IN #2 PORT TANK TO OTHER FUEL TANKS ON VESSEL. ITEM TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 29 June 1994
Resolved 15 July 1994
Engineering
Issued 28 June 1994 Resolved
INSTALL PROPER FLAME SCREEN ON #1 PORT BALLAST TANK VENT. ITEM TO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 28 June 1994
Resolved 7 July 1994
Construction/Loadline
Issued 28 June 1994 Resolved
MAKE PERMANENT REPAIR TO HOLE/DAMAGE BETWEEN #1 PORT BALLAST TANK & #2 PORTFUELING TANK. THIS ITEM TO BE COMPLETED PRIOR TO LOADING ADDITIONAL FUELS IN #2 PORT FUEL TANK.
Condition: Unknown
Due 28 June 1994
Resolved 28 June 1994
Engineering
Issued 26 February 1993 Resolved
STBD AIR RECEIVER NOT INTERNALLY INSPECTED DUE TO PORT AIR COMPRESSOR BEINGOOC.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Engineering
Issued 26 February 1993 Resolved
ISSUED CG-835 ITEM TO TEST PRESSURE RELIEF VALVES ON P & S AIR RECEIVERS.
Condition: Unknown
Due 26 February 1993
Resolved 26 February 1993
Electrical
Issued 6 February 1991 Resolved
PROVIDE CG APPROVED PLANS FOR THE NEW 100 KW GENERATOR & HYDRAULIC CRANE ELECTRICAL INSPALLATION AND THE NEW FEEDER TO THE ANCHOR WICH, IN ACCORDANCE WITH 46CFR 91.45-1 AND 46CFR 91.55-15.
Condition: Unknown
Due 6 February 1991
Resolved 6 February 1991
Construction/Loadline
Issued 6 August 1984 Resolved
MAKE PERMANENT REPAIR TO STARBOARD BOW BULLWORK AND HULL.
Condition: Unknown
Due 6 August 1984
Resolved 6 August 1984

Casualty record · 1

10 August 2013Routine · role: Involved in a Marine Casualty · activity 4747331
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.