This record may be incomplete: the most recent inspection recorded for this vessel was 13 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton 29 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 23 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
REPLACE WING NUTS WITH HEX TYPE NUTS ON ALL BATTERIES.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Lifesaving
Issued 3 July 1995Resolved
MARK/LABEL STORAGE AREA'S FOR ALL ADULT SIZE LIFE PRESERVERS.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Navigation
Issued 3 July 1995Resolved
OBTAIN A CURRENT CHART OF OPERATING AREA.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Lifesaving
Issued 3 July 1995Resolved
OBTAIN 6 RED FLARES.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Lifesaving
Issued 3 July 1995Resolved
INSTALL/PUT ON RETROREFLECTIVE MATERIAL ON BOTH THE BUOYANT APPARATUS AND THE LIFE FLOAT.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Lifesaving
Issued 3 July 1995Resolved
REPLACE TAG LINES AS NEEDED ON BOTH THE BUOYANT APPARATUS AND THE LIFE FLOAT.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Engineering
Issued 3 July 1995Resolved
REPLACE FLAME SCREENS ON BOTH FUEL OIL TANKS WITH 30 X 30 MESH SCREEN.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Electrical
Issued 3 July 1995Resolved
REPAIR/REPLACE GROUNDING WIRE ON THE FILL PIPE ON THE PORT FUEL OIL TANK.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Electrical
Issued 3 July 1995Resolved
REMOVE DEAD END WIRES FROM AROUND THE PORT MAIN ENGINE.
Condition: Unknown
Due 18 July 1995
Resolved 21 September 1995
Deck/Cargo
Issued 3 July 1995Resolved
MAKE REPAIRS TO THE CARGO BOOM SUPPORTS PRIOR TO DOING ANY CARGO OPERATIONSWITH THE USE OF THE BOOM.
Condition: Unknown
Due 3 July 1996
Resolved 21 September 1995
Unknown
Issued 12 April 1993Resolved
Demonstrate compliance with the Coast Guard's drug testing program._x001C_
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Construction/Loadline
Issued 12 April 1993Resolved
Replace three (3) horizontal stiffeners on on the transom.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Navigation
Issued 15 May 1992Resolved
Provide current light list.
Condition: Unknown
Due 1 June 1992
Resolved 12 June 1992
Lifesaving
Issued 15 May 1992Resolved
Provide 02 Life rings.
Condition: Unknown
Due 1 June 1992
Resolved 12 June 1992
Documentation
Issued 29 May 1991Resolved
VESSEL MISSING CURRENT FCC STATION LICENSE.
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Documentation
Issued 29 May 1991Resolved
VESSEL MISSING CURRENT FCC OPERATOR LICENSE
Condition: Unknown
Due 29 May 1991
Resolved 29 May 1991
Documentation
Issued 9 April 1990Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Accommodation/Occupational Safety
Issued 9 April 1990Resolved
REPLACE RELIEF VALVE ON PRESSURE VESSEL WITH ONE THAT IS RATED AND CAN BE MANUALLY TESTED
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1990Resolved
PERMANENTLY MOUNT 120V OUTLETS FROM GENERATOR CONTROL PANELS
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1990Resolved
PERMANENTLY MOUNT GENERATOR TEMP GAUGE
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1990Resolved
MAKE ELEC WIRING CONNECTIONS TO COMPASS PERMANENT (CRIMP)
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Deck/Cargo
Issued 6 July 1989Resolved
TEST CARGO BOOM AND MARK WITH SAFE WORKING LOAD (SWL) AND DATE OF TEST
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Electrical
Issued 6 July 1989Resolved
REPLACE STBD ENGINE WETMETER
Condition: Unknown
Due 6 July 1989
Resolved 6 July 1989
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.