MAURY USCG vessel records Sign in
← All vessels

MR. ANDRE

MR. ANDRE is a 1980 offshore supply vessel. The Coast Guard has recorded 49 inspections since 1981, most recently in February 2011, along with 29 deficiencies.

Records from 1981 to 2011. Most recent: inspection, 15 February 2011.

Built
1980
Last inspected
15 February 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC8896
Flag
UNITED STATES
367094720 (licence lapsed)
Maury page id
psix-52136

Inspections, by type

…with no type recorded13
Years with a record 29 calendar years (1981–2011)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it63 - Regulatory (Subpart C or D), Net Ton
92 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC8896MMSI 367094720 · expired · compulsorily equipped · granted 23 February 2006, cancelled 30 April 2016
WCX3226MMSI not assigned · expired · compulsorily equipped · granted 19 March 1997, cancelled 20 May 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 49

15 February 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3945229
7 July 2009 Examination of Repairs · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3527193
26 September 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3333138
22 August 2008 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3305506
22 August 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3305514
20 August 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3304226
21 April 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3188762
2 May 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2922350
28 February 2007 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879612
20 September 2006 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2784200
21 March 2006 COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2606534
22 February 2006 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2610337
13 April 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2332939
12 July 2004 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2130513
29 April 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2055121
20 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1759667
4 February 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1483721
3 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444475
12 June 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 58411
12 June 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 721560
12 May 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049692
1 February 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418652
13 July 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401038
15 March 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806142
1 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390921
21 January 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392848
5 February 1997 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435872
5 November 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882339
17 February 1995 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357020
11 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 87904
11 February 1995 Permit to Proceed
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1355105
18 July 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456182
23 June 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 843814
28 October 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268939
4 October 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938721
27 September 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219450
12 October 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920973
30 September 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200457
30 September 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201986
3 November 1987 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1004285
9 October 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1018819
26 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018884
16 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016904
9 October 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321637
11 October 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986668
21 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285395
21 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975517
12 November 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966904
10 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276736

Deficiency record · 29

Construction/Loadline › Structures › Scuttle
Issued 15 February 2011 Resolved
Handle missing on engine room emergency escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 February 2011
Resolution: Handle found and replaced. Tested and worked properly prior to completion of inspection.
Deck/Cargo › Marine Portable Tanks › Securing Device
Issued 22 August 2008 Resolved
Vessel failed to secure all deck cargo as per stability letter
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 August 2008
Resolution: Directed crew to secure cargo
Navigation › Piloting/Steering › Marine Charts
Issued 21 April 2008 Resolved
Provide updated navigational charts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 21 April 2008 Resolved
Label Emergency Fuel Shutoff
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 21 April 2008 Resolved
Show proper operation of installed Fire Pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 April 2008
Stability › Watertight Integrity › General
Issued 21 April 2008 Resolved
Install safety chains on escape hatch cover on deck.
Due 22 April 2008
Resolved 22 April 2008
Fire Fighting › Fire Hoses › Condition
Issued 2 May 2007 Resolved
One fire hose was torn and the rubber lining was bulging through. The second was leaking at the connection to the station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2007
Engineering › Steering Gear System › Linkage
Issued 21 March 2006 Resolved
Repair wasted tiller arm, pins and hardware.
Condition: Unknown
Due 22 March 2006
Resolved 21 March 2006
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 13 April 2005 Resolved
Provide and demonstrate use of a rescue platform.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 May 2005
Resolved 14 April 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 13 April 2005 Resolved
Provide and install (2) spare 15# dry chemical extinguishers prior to the carriage of Marine Potable Tanks.
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 14 April 2005
Communications › Radio Communications
Issued 20 March 2003 Resolved
Repair or replace radio and insure proper operation. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2003
Resolved 21 April 2003
Communications › Radio Communications
Issued 20 March 2003 Resolved
Service the Single Side Band radio and insure proper operation. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2003
Resolved 21 April 2003
Stability › Watertight Integrity
Issued 20 March 2003 Resolved
Adjust watertight door to the engine room. LEGACY COMPONENT DESC: Watertight Door
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2003
Resolved 21 April 2003
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 4 February 2002 Resolved
PROVIDE A CURRENT DEVIATION COMPASS CARD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 February 2002
Resolved 15 February 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 4 February 2002 Resolved
REPAIR LUBE OIL, AND MDE WATER TEMP GAUGES AT THE OPERATING STATION. LEGACY COMPONENT DESC: GAUGES
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2002
Resolved 15 February 2002
Engineering › Bilge Water Management System › Valve
Issued 4 February 2002 Resolved
PROVIDE CHECK VALVE FOR RUDDER ROOM BILGE SUCTION LINE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 15 February 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 4 February 2002 Resolved
PROVIDE AND INSTALL FLAME SCREEN FOR LUBE OIL TANK VENT. LEGACY COMPONENT DESC: FLAME SCREEN
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 15 February 2002
Stability › Incline Test
Issued 4 February 2002 Resolved
PROVIDE VESSEL STABILITY LETTER. LEGACY COMPONENT DESC: STABILITY LETTER
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 March 2002
Resolved 29 April 2004
Lifesaving
Issued 1 February 2000 Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENT ON OFFSHORE SUPPLY VESSELS DATED 12NOV98 TO THE SATISFACTION OFATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 February 2000
Resolved 1 February 2000
Construction/Loadline
Issued 1 February 1999 Resolved
PROVE PROPER OPERATION OF BILGE ALARMS IAW 46 CFR 182.500 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Documentation
Issued 9 October 1987 Resolved
PROVIDE WITHOUT DELAY PROPER DOCUMENT FOR THIS VESSEL TO REPRESENTATIVE OF MSO MORGAN CITY
Condition: Unknown
Due 9 October 1987
Resolved 9 October 1987
Electrical
Issued 9 October 1986 Resolved
PROVIDE BLANK COVER FOR MISSING CIRCUIT BREAKER IN PANEL IN ENGINE ROOM ACCESS. PROVIDE DIRECTORIES FOR ALL DISTRIBUTION PANELS.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Navigation
Issued 9 October 1986 Resolved
TIGHTEN OR REPACK PORT RUDDER SHAFT PACKING TO PREVENT LEAKAGE.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Documentation
Issued 9 October 1986 Resolved
PROVIDE LOADING DIAGRAM AND TANK TABLE FOR USE ONBOARD VESSEL.
Condition: Unknown
Due 9 October 1986
Resolved 9 October 1986
Electrical
Issued 21 November 1984 Resolved
ENSURE ONE VHF FM RADIO IS OPERABLE ON EMERGENCY POWER CIRCUT.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Unknown
Issued 21 November 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO VSL [name withheld]628516.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Accommodation/Occupational Safety
Issued 21 November 1984 Resolved
REPAIR AIR CONDITIONER LEAK IN GALLEY AREA.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Navigation
Issued 21 November 1984 Resolved
REPAIR OR REMOVE SOUND POWERED TELEPHONE SYSTEM.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984
Electrical
Issued 21 November 1984 Resolved
REPAIR EMERGENCY LIGHT IN ENGINEROOM.
Condition: Unknown
Due 21 November 1984
Resolved 21 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.