Records from 1982 to 2008. Most recent: inspection, 11 February 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
11 February 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3145732
16 February 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2586324
16 February 2006
Cargo Tank Internal · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2586351
12 October 2005
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2512598
6 January 2005
Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2270435
13 January 2004
Internal Structural Exam · Cargo Tank Internal · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1983258
25 November 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1954423
17 November 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1950225
14 January 2003
Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1727956
8 November 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773128
17 October 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 823460
5 October 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817080
5 October 1999
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1386608
30 October 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 44712
1 October 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404620
29 January 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386223
1 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783635
25 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776547
6 March 1997
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450010
2 February 1996
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438437
22 November 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427141
29 March 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416146
25 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465136
3 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 691341
31 October 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 148756
30 March 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358038
26 February 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958772
27 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1215281
8 March 1991
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217815
12 June 1990
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915678
22 March 1990
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 911977
12 March 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 907717
27 February 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 927458
28 August 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1339705
22 March 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040225
16 February 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1351610
15 April 1988
Deficiency Check · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338036
1 March 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027178
20 March 1987
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328337
7 March 1986
COI Inspection · Examination of Repairs · Credit Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1306587
24 July 1985
Examination of Repairs · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1289952
18 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977805
20 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979130
8 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280772
3 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964070
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 10 February 2004
Resolved
Renew 3 lifejackets and renew retro-reflective tape on Pilot House lifejacket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2004
Electrical › Electrical Distribution System (service)
Issued 10 February 2004
Resolved
Provide blanks for Galley electrical panel. LEGACY COMPONENT DESC: Panel board
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 February 2004
Resolved
Renew retro-reflective tape and provide plug for port aft Main Deck lifebuoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2004
Resolved
Make repairs to switchboard ammeter.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 10 February 2004
Resolved
Make repairs to both switchboard ground indicators to remove ground.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2004
Engineering › Fuel Oil Service System › Hose
Issued 10 February 2004
Resolved
Renew main engine fuel priming pump hoses to the proper type.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 February 2004
Resolved
Make repairs to the magnetic compass light prior to conducting nighttime operations.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Fire Fighting › Fire Pumps › Casing
Issued 10 February 2004
Resolved
Make repairs to fire pump to prevent leakage.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 10 February 2004
Resolved
Provide bug screen for port aft potable water vent.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 14 January 2003
Resolved
Advised master to establish maintenance and record results iaw 46 CFR 199.190.
Condition: Improper/Lack of Maintenance
Due 14 January 2003
Resolved 14 January 2003
Engineering › Steering Gear System
Issued 14 January 2003
Resolved
Adjust limit switch so steering assembly does not strike rudder stops.
Condition: Improper Installation
Due 14 January 2003
Resolved 14 January 2003
Unknown
Issued 1 October 1998
Resolved
PROVIDE/POST UPDATED COPY OF FIRE SAFETY PLAN AND DEMONSTRATE ACCURATE LOCATION OF ALL SAFETY EQUIPMENT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 October 1998
Resolved 1 October 1998
Lifesaving
Issued 29 March 1995
Resolved
PROVIDE ONBOARD A SUITABLE RESCUE BOAT OR DEMOSTRATE THE VESSELS ABILITY TOMANEUVER AND RECOVER A 165 LB OBJECT WHILE UNDERWAY. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 April 1995
Resolved 21 June 1995
Navigation
Issued 12 June 1990
Resolved
MAKE PERMANENT REPAIRS TO FORWARD AND AFT MAST INCLUDING NAVIGATION LIGHTS MOUNTED ON MASTS. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS IN CLEAR VISIBILITY ONLY.
Condition: Unknown
Due 12 June 1990
Resolved 12 June 1990
Documentation
Issued 12 March 1990
Resolved
CORRECT OIL TRANSFER PROCEDURES, INADEQUATE.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Deck/Cargo
Issued 12 March 1990
Resolved
REPLACE MISSING SCUPPER PLUGS FOR (2) OIL POLLUTION CONTAINMENTS.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Lifesaving
Issued 16 February 1989
Resolved
POST AT LIFERAFT STATIONS PICTURE-TYPE LAUNCHING INSTRUCTIONS FOR BRAND OF INFLATABLE CARRIED ABOARD VESSEL.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Electrical
Issued 16 February 1989
Resolved
PROVE PROPER OPERATION OF POWER PANEL GROUND DETECTOR.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989
Deck/Cargo
Issued 1 March 1988
Resolved
PROVIDE ON BOARD VESSEL AN ADDITIONAL ANCHOR AND CHAIN OF PROPER WEIGHT ANDSTRENGTH OR PROVE VESSEL IS EQUIPMENT NO. 150 OR LESS.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Navigation
Issued 1 March 1988
Resolved
PROVIDE ON BOARD VESSEL, CURRENT TIDAL & CURRENT TABLES, U. S. COAST PILOT AND EAST AND GULF COAST LIGHT LIST.
Condition: Unknown
Due 1 March 1988
Resolved 1 March 1988
Unknown
Issued 18 July 1985
Resolved
REPAIR THE CRACKED WELD AT THE DENT ON THE STARBOARD BOW JUST AFT OF THE STEM.
Condition: Unknown
Due 18 July 1985
Resolved 18 July 1985