Records from 1981 to 2017. Most recent: inspection, 20 September 2017.
Inspection history · 68
20 September 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6271087
1 October 2015
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5905199
20 June 2014
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4893274
23 May 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4319805
1 February 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4235926
20 November 2010
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3911120
12 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3662889
3 February 2009
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3427624
19 December 2007
Re-Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3118521
16 February 2007
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2876682
27 September 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2788055
14 March 2006
Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2599367
23 February 2006
Drydock Extension
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2590811
16 July 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2435836
7 July 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2435498
26 January 2005
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2277378
22 March 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2026202
16 July 2003
In-Service Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1847725
21 March 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1760660
5 February 2002
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1483964
4 September 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 769301
27 August 2001
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 209650
16 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 143594
12 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075141
28 March 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433806
25 April 2000
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 452831
12 April 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 495207
31 January 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465524
13 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 494594
26 February 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381487
29 October 1998
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766537
7 October 1998
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 207792
30 January 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1441345
12 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113988
20 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102732
7 March 1997
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 695345
29 January 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371662
12 December 1996
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 203063
18 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765025
4 July 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194010
12 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765193
19 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 203064
16 February 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367654
10 February 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396243
30 September 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 121226
28 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 865140
27 September 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 695346
30 July 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 31648
8 April 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 86754
4 March 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362937
24 December 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 18536
4 March 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151064
8 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 999392
5 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917109
27 August 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241491
12 October 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898635
5 January 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349939
26 April 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035913
19 January 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1013753
26 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009513
21 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319097
24 January 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305277
2 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986040
27 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280475
17 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280631
27 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271990
3 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972107
11 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274267
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 February 2007
Resolved
Obtain 'Coastwise' endorsement for COI.
Condition: Unknown
Due 16 March 2007
Resolved 16 April 2007
Lifesaving › Lifefloat › Painter
Issued 16 February 2007
Resolved
Re-rig lifefloats, lower LF to have sea painter vice top one, ensure proper length of painter lines between stacked floats.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 February 2007
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 16 February 2007
Resolved
Remove petcocks from all fuel filters, provide steel plugs.
Condition: Improper Installation
Due 16 March 2007
Resolved 24 February 2007
Fire Fighting › Fire Hoses › Condition
Issued 16 February 2007
Resolved
Replace 1-50 ft section of fire hose due to leak.
Condition: Improper/Lack of Maintenance
Due 16 February 2007
Resolved 16 February 2007
Construction/Loadline › Structures › Door
Issued 16 February 2007
Resolved
Renew striker plates on engine room WTD & passageway WTDs.
Condition: Improper/Lack of Maintenance
Due 16 March 2007
Resolved 24 February 2007
Communications › Radio Communications › EPIRB
Issued 16 February 2007
Resolved
Relocate EPIRB from under antenna installation to ensure float free arrangement.
Condition: Improper Installation
Due 16 March 2007
Resolved 24 February 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 16 February 2007
Resolved
Provide new fire extinguisher for T-Baker shed ondeck.
Condition: Improper/Lack of Maintenance
Due 16 March 2007
Resolved 16 February 2007
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 February 2007
Resolved
Provide current navigational publications.
Condition: Improper/Lack of Maintenance
Due 16 March 2007
Resolved 16 February 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 February 2006
Resolved
Vessel has exceeded its drydock exam interval. Vessel has been granted a 30 day drydock extension. Vessel must be made available for inspection before 25 Mar 06.
Action required: 705 - Other - as specified
Due 25 March 2006
Resolved 20 March 2006
Resolution: Completed vessel drydock exam at Bolinger Shipyard.
Navigation › Piloting/Steering
Issued 21 March 2003
Resolved
PROVIDE UPDATED LOCAL NOTICE TO MARINERS. LEGACY COMPONENT DESC: Local Notices to Mariners
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Stability › Watertight Integrity
Issued 21 March 2003
Resolved
ADJUST ALL WATERTIGHT DOORS PRIOR TO SAILING. LEGACY COMPONENT DESC: WATERTIGHT DOORS
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 21 March 2003
Resolved
PROVIDE COVER FOR GALLEY RANGE LIGHT BULB. LEGACY COMPONENT DESC: GALLEY RANGE
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 21 March 2003
Resolved
RESTOCK ALL FIRST AID KITS THROUGHOUT VESSEL. LEGACY COMPONENT DESC: Medicine Chest
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Engineering › Fuel Oil Storage/Transfer System
Issued 21 March 2003
Resolved
PROVIDE METALLIC PLUGS FOR RACORS UNITS IN ENGINEROOM. LEGACY COMPONENT DESC: Filter/Strainer
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Communications › Radio Communications
Issued 21 March 2003
Resolved
PROVIDE 1 VHF RADIO TO OPERATE UNDER EMERGENCY POWER. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Communications › Internal Communications System
Issued 21 March 2003
Resolved
INSTALL PA SYSTEM THROUGHOUT VESSEL. LEGACY COMPONENT DESC: PA SYSTEM
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Electrical › Lighting (emergency)
Issued 21 March 2003
Resolved
PROVIDE 1 EMERGENCY LIGHT TO ILLUMINATE EMERGENCY ESCAPE HATCH FROM ENGINEROOM. LEGACY COMPONENT DESC: Battery Operated Lantern
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2003
Resolved 25 March 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 5 February 2002
Resolved
REPAIR STARBOARD MAIN ENG. WATER TEMP. GAUGE. LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2002
Resolved 21 February 2002
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 February 2002
Resolved
PROVIDE COVER FOR GALLEY HOOD LIGHT FIXTURE.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 21 February 2002
Engineering › Fuel Oil Service System › Filter
Issued 5 February 2002
Resolved
PROVIDE PLUGS FOR RACOR FILTER DRAIN COCKS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 21 February 2002
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 5 February 2002
Resolved
PROVIDE FLAME RESISTANCE SIGHT GLASS FOR FUEL OIL TANKS.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 25 February 2002
Construction/Loadline › Structures
Issued 5 February 2002
Resolved
PROVIDE PLUGS FOR TWO VENTS LOCATED ON THE BOW. LEGACY COMPONENT DESC: Air Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 March 2002
Resolved 21 February 2002
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 5 February 2002
Resolved
PLACE SINGLE SIDE BAND ON THE FINAL POWER SOURSE PRIOR TO VOYAGES OVER 100 MILES FROM LAND.
Condition: Improper/Lack of Maintenance
Due 21 March 2002
Resolved 21 February 2002
Construction/Loadline
Issued 31 January 2000
Resolved
Damage to transom plating and stern wrap framing detected during hull exam.Vessel allowed to affect permenant repairs to damaged area at next drydock as per Morgan City CID. Affect repairs to the satisfaction of the attendingmarine inspector. See mins of this case for details concerning damage.
Condition: Unknown
Due 31 January 2002
Resolved 21 March 2003
Resolution: REPAIRS WERE CORRECTED AND NEVER ENTERED BY [name withheld] 2002 DRYDOCK.