MAURY USCG vessel records Sign in
← All vessels

KODIAK ISLAND

KODIAK ISLAND is a 1980 offshore supply vessel. The Coast Guard has recorded 46 inspections since 1982, most recently in June 2007, along with 108 deficiencies and 3 operational controls.

Records from 1982 to 2007. Most recent: inspection, 29 June 2007.

Built
1980
Last inspected
29 June 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7901992 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO- 4605
Flag
PANAMA
368159000 (licence lapsed)
Maury page id
psix-52178

Inspections, by type

…with no type recorded8
Years with a record 21 calendar years (1982–2007)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it202 - Regulatory (Subpart C or D), Net Ton
297 - Regulatory (Subpart C or D), Gross Ton
750 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WYQ7845MMSI 368159000 · cancelled · compulsorily equipped · granted 11 August 1998, cancelled 22 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 46

29 June 2007 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2975676
19 February 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2874081
29 January 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2863365
18 July 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2761890
7 July 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2705223
22 July 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2141237
22 October 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1077191
16 July 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384823
24 January 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384662
21 September 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462895
16 November 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 807818
9 July 1999 COI Inspection
Physical examination · Activities Europe · Activity 1369273
2 July 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372277
20 April 1998 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 135415
20 April 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1124669
26 March 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 762705
5 March 1998 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386212
5 February 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 190264
5 February 1998 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1107855
19 September 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1120449
28 August 1997 Administrative
Administrative · Activities Europe · Activity 1120651
11 July 1997 Re-Inspection
Physical examination · Activities Europe · Activity 781331
10 June 1997 Administrative
Administrative · Activities Europe · Activity 1110420
28 February 1997 Administrative
Administrative · Activities Europe · Activity 1101346
4 December 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1186734
15 April 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1079791
8 March 1996 COI Inspection · Hull Examination
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1363533
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1188289
6 September 1993 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837817
26 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1138566
29 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247875
20 May 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 949255
28 April 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954565
16 April 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1267490
10 January 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 952277
23 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210828
7 January 1991 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 904814
1 February 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1246237
18 January 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909620
12 January 1989 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 887869
20 January 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1324830
9 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319763
28 January 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302099
23 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291511
24 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278597
19 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276977

Deficiency record · 108

Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 29 June 2007 Resolved
Air conditioning system was found inoperable. Berthing accomadations were found to be unbearable in warm weather. Rectify prior to departure. PWSA- 33USC1221, and ILO 147.
Action required: 705 - Other - as specified
Resolved 6 July 2007
Resolution: Recieved reciept of work completed on Air conditioning unit, and of satisfactory tests completed.
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 29 June 2007 Resolved
Vessel only has 3 line throwing projectiles and lines onboard. Solas 60 Reg 23(b).
Action required: 705 - Other - as specified
Due 29 July 2007
Resolved 5 July 2007
Resolution: Ordered new line throwing device and line.
Lifesaving › Launching Appliances › Davit
Issued 29 June 2007 Resolved
Wire line for davit assembly to rescue boat is rubbing against davit arm, creating potential for fraying. No chafing gear or protective equipment is onboard to rectify. Solas 74(2004 Cons. Ed.) ; III/17. Rectify prior to departure.
Action required: 705 - Other - as specified
Resolved 5 July 2007
Resolution: Chafing gear was rigged for wire line.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 29 June 2007 Resolved
No ballast water management plan onboard. Rectify prior to departure and to the satisfaction of Coast Guard and Class.
Action required: 705 - Other - as specified
Resolved 5 July 2007
Resolution: Ballast water management plan was implemented and onboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 June 2007 Resolved
No garbage management plan onboard. Rectify prior to departure, and to the satisfation of class and the Coast Guard.
Action required: 705 - Other - as specified
Resolved 5 July 2007
Resolution: Garbage management plan was implemented and onboard.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 29 June 2007 Resolved
Garbage is mixed/ collection points not identified. Everything except for food waste, oily rags, and cardboard is mixed together and discharged to a reception facility. Garbage record book entries and receipts both list these under the "other" category, without specifying the amounts of plastics under cat. 1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2007
Resolution: Garbage is now segregated, and recorded as segregated.
Fire Fighting › Nozzles › Condition
Issued 29 June 2007 Resolved
Forward most fire nozzle leaks excessively due to attatchment missing. Does not impede vessels ability to fight a fire effectively. Solas 60 Ch 2 Reg. 56(g).
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 5 July 2007
Resolution: New nozzle was supplied.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 29 June 2007 Resolved
Bunkering transfer hoses on deck are not blanked off, only covered on ends with trash bags.
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 29 June 2007
Resolution: Corrected on the spot. In port5 transfer hoses were removed from the vessel.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 29 June 2007 Resolved
No information marked on the transfer hose as required by 33CFR 154.500(e), and no records of hose tests including dates and results. Vessel prohibited from bunkering in US waters until test is satisfactory.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 5 July 2007
Resolution: Transfer hoses were not needed and removed from the vessel.
Documentation › Logs/Records › Enhanced Survey Report File
Issued 29 June 2007 Resolved
Vessels survey report file does not have most recent, and complete hull and machinery surveys. Class survey summary does not reflect most recent dates of individual surveys.
Action required: 705 - Other - as specified
Due 29 July 2007
Resolved 5 July 2007
Resolution: Verify report dated 28Sep06.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 29 June 2007 Resolved
Solas training manual not undated to reflect modified equipment onboard; specifically, instructions for operation and maintenance of new rescue boat and davit assembly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2007
Resolution: USCG verified updated complete.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 29 June 2007 Resolved
Planned maintenance scheduled and required by the SMS could not be provided. Documentation provided does not reflects ships instructions provided by the company.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 5 July 2007
Resolution: Verified adequate maintenance schedule onboard.
Lifesaving › Emergency Outfit › Breathing Apparatus
Issued 29 June 2007 Resolved
In engine room; Port side EEBD has no air pressure; Stbd side EEBD is over pressurized. No spares could be provided onboard. Rectify to the satisfaction of class. Solas 74 (2004 Cons. Ed.) ; II-2/ 13.4.3.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2007
Resolution: Two were replaced and two spares onboard.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 29 June 2007 Resolved
Engine room bilge alarm is inoperable. Unable to produce audible or visual indication of high bilge level in engine room.
Action required: 705 - Other - as specified
Due 29 July 2007
Resolved 5 July 2007
Resolution: USCG verified satisfactory operation.
Documentation › Logs/Records › Oil Record Book
Issued 29 January 2007 Resolved
Vessel failed to make appropriate & timely entries in to Oil Record book. Entries only made when taking on fuel oil. Last entry: December 30, 2006. Only 2.5 pages filled out. 30a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: oil record book has been reviewed by the class surveyor.
Documentation › Logs/Records › Oil Record Book
Issued 29 January 2007 Resolved
Master failed to sign completed pages in vessels Oil Record book. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: master has reviewed pages and signed each completed page of the oil record book.
Documentation › Logs/Records › Logbook (official)
Issued 29 January 2007 Resolved
Bridge Log not properly maintained - entries made at random and not on consecutive hours/days. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: New procedures have been put in place for departure. Inport activities have been properly logged in bridge log book.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 29 January 2007 Resolved
Port & Stbd primary containment around oil/ shore connection missing mechanical means to close drain/scupper. Light sheen openly flowing from containment overboard on port side. 17a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: all drains were outfitted with mechanical means to prevent flow out of the primary containment.
Lifesaving › Line-Throwing Appliances › Lines
Issued 29 January 2007 Resolved
Vessel missing three (3) line-throwing projectiles and lines 17a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Vessel provided three new line throwing guns with projectiles and lines.
Communications › Radio Communications › EPIRB
Issued 29 January 2007 Resolved
Vessels EPIRB not capable of floating free if vessel sinks. EPIRB stowed in cardboard box on bridge and then duct-taped to pilot house. 17a/c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: New EPRIB housing properly installed on vessel pilot house.
Construction/Loadline › Markings › Load Line Mark
Issued 29 January 2007 Resolved
Load line marking missing from the starboard side of the ship. 17a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: load line has been punched and painted a contrasting color.
Navigation › Piloting/Steering › Magnetic Compass
Issued 29 January 2007 Resolved
Vessels Magnetic compass not properly adjusted - 60 degree difference between GPS & magnetic reading despite 1 deg E deviation and 14 deg variation. 30a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: magnetic compass had been adjusted by a certified technician. ship''s compass was swung on 2/9/07 and new deviation table was calculated for the vessel.
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 29 January 2007 Resolved
GPS powers off randomly. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Vessel installed new GPS receiver.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 29 January 2007 Resolved
Vessels echo-sounding device continually fluctuates between 37ft and 310ft while at the pier. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Depth sounder repaired. Tech reported provided and verified by reporting charted depth.
Navigation › Collision/Grounding Avoidance › Radar
Issued 29 January 2007 Resolved
Furuno radar cannot be viewed during daylight due to low screen contrast. Koden radar produces an egg-shaped image. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Foruno radar repaired by competent technical authority. Second radar renewed.
Navigation › Piloting/Steering › Marine Charts
Issued 29 January 2007 Resolved
Chart corrections not maintained or updated. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: New charts printed on demand for transit between Seattle and Peru.
Navigation › Piloting/Steering › US Coast Pilot
Issued 29 January 2007 Resolved
Missing Sailing Directions, Coast Pilot, Notice to Mariners, Tide Tables, & Current Tables. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: New publications provided.
Communications › Audible Communications › Horn/Whistle
Issued 29 January 2007 Resolved
Ship's whistle inoperative. 17a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Ship''s whistle repaired and tested
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 29 January 2007 Resolved
Self-igniting lights on Port/Stbd life buoys on bridge were missing. 30a/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: lightes renewed for lights on both port and starboard side.
Lifesaving › Lifebuoys › Immediately Available
Issued 29 January 2007 Resolved
Life Buoys not capable of being rapidly cast loose and tied to the ship. 17a/c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: life buoys had been untied from vessel railings.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 29 January 2007 Resolved
Master's license expired August 21, 2006. 30a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: Orginal master has been replaced. New master has Philipine master''s license with Panamanian endorsement.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 29 January 2007 Resolved
Chief Engineer missing STCW certificate. 30 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: Both the Philipines license and Panamanian endorsement were provided.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 29 January 2007 Resolved
2nd Engineer missing STCW certificate. 30 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: Both the Philipines license and Panamanian endorsement were provided.
Personnel › Certificates/Documents/Licenses › STCW Certificate of Proficiency, Survival Craft
Issued 29 January 2007 Resolved
Remaining crew does not posses STCW certificates for Basic Training A-VI/1-1, 1-2, 1-3 AND 1-4. 30 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: Panamanian endorsements for all required training has been provided.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 29 January 2007 Resolved
Vessel is unable to produce any records of life saving equipment inspections or maintenance. 30a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: received tech reports for all required lifesaving equipment. equipment maintenance entered into SMS program.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 29 January 2007 Resolved
Vessel is unable to produce any records of inspections or maintenance for engineering equipment. 17 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: Reviewed vessel''s SMS procedures for engineering equipment. reviewed all maintenance records.
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 29 January 2007 Resolved
Vessels Master Failed to report deficient items 1-24 as-per the Vessels SMS program. 30 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: Deficiencies have been reported.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 29 January 2007 Resolved
No means to transmit heading information for input to radar and automatic tracking aid. 17 a/c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: renewed radar has both ARPA capability as well as integration with vessel''s AIS
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 29 January 2007 Resolved
Numerous deficiencies associated with Appendix 1 - Guidelines for detention of ships. Resolution A787(19), as amended by A.882(21) 30c
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Fire Fighting › Firemans Outfit › Lifeline
Issued 29 January 2007 Resolved
Firemen not familiar with use of tending line - crew could not find tending line until after the drill was complete.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 9 February 2007
Resolution: Tending line was properly used during subsequent drill.
Fire Fighting › Firemans Outfit › Axe
Issued 29 January 2007 Resolved
Firemen did not utilize fire axes during drill.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2007
Resolution: Fire axes were utilized during subsequent drill.
Fire Fighting › Firemans Outfit › Lantern (Electric Safety Lamp)
Issued 29 January 2007 Resolved
Only one fire suit had a lantern provided with it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 February 2007
Resolution: Both responders carried an appropriate electric lantern.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 29 January 2007 Resolved
Vessel carries inflatable liferafts and rescue boat in lieu of lifeboats. Installed complement of inflatable life rafts adequate for only 100% of crew and crew unable to easily shift liferaft from one side to another in emergency. 30c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2007
Resolution: 16 person liferaft provided on stbd side & 2 @ 10 personliferafts were provided on the port side.
Lifesaving › Rescue Boat › Inflated Condition
Issued 29 January 2007 Resolved
inflatable pontoons of rescue boat deflated upon entry into port. 30c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Resolution: pontoons fully inflated.
Lifesaving › Rescue Boat › Construction
Issued 29 January 2007 Resolved
rigid-hull inflatable designated as rescue boat is not SOLAS approved. 30c
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2007
Resolution: Renewed rescue boat with a SOLAS approved boat.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 29 January 2007 Resolved
Rescue boat outboard engine failed to start despite 25 minutes of effort by crew. 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 February 2007
Resolution: Renewed rescue boat and engine with a SOLAS approved boat.
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 7 July 2006 Resolved
The Chief Engineer was unable to provide evidence of valid Panamanian endorsement of his ST Vincent and Grenadine license. STCW 78/95 I/4
Action required: 705 - Other - as specified
Resolved 11 July 2006
Resolution: The vessel received a new Chief Engineer with a valid Panamanian endorsement.
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 7 July 2006 Resolved
The OCMI doubts the validity of the ship's Safety Management Certificate. The ship is unable to provide evidence of a documented and implemented Safety Management System. SOLAS 74 (Amended) I/19
Action required: 705 - Other - as specified
Due 11 July 2006
Resolved 11 July 2006
Resolution: Sector Houston-Galveston received an ISM Audit from the Flag State addressing each deficiency issued.
Operations/Management › Drills/Instruction › Fire
Issued 7 July 2006 Resolved
During a fire drill conducted on board the vessel there was no discernible procedure followed meeting minimum SOLAS standards or ship's training manual. Personnel were unfamiliar with use of ship's fire safety personal protective equipment. SOLAS 60 III/26
Action required: 705 - Other - as specified
Resolved 11 July 2006
Resolution: Sector Houston-Galveston received an ISM Audit from the Flag State addressing each deficiency issued.
Navigation › Piloting/Steering › Gyro Compass
Issued 7 July 2006 Resolved
The vessel does not have a gyro compass installed. The vessel is only equipped with redundant magnetic compasses. SOLAS 74 (Amended) V/19
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 10 July 2006
Resolution: The vessel is equipped with 2 GPS''s, which meets the requirements of SOLAS 74 (Amended) V/19
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 7 July 2006 Resolved
Vessel does not have SOLAS 74 (Amended) V/19
Action required: 705 - Other - as specified
Resolved 11 July 2006
Resolution: The vessel purchased current nautical charts and publications.
Deck/Cargo
Issued 9 July 1999 Resolved
Renew the vessel's deteriorated cargo/fuel transfer hoses and ensure all requirements of 33 CFR 156.170 are met. Vessel shall use approved transferhoses during all fuel transfer operations.
Condition: Unknown
Due 9 July 1999
Resolved 9 July 1999
Engineering
Issued 9 July 1999 Resolved
Prove the proper operation of the Port Main Engine including all shutdowns,remote controls, and monitored alarms. A representative of the American Bureau of Shipping shall witness all tests and forward report to MIO Europe. This item must be completed prior to departure from Abidjan, IV.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Engineering
Issued 20 April 1998 Resolved
MAKE PERMENTALY REPAIRS TO DRAIN PIPING FROM #2, #4, AND #6 DRY BULK TANK MANHOLE COMMING DECK DRAIN. #1 STARBORD FUEL TANK IS TO BE GAS FREE AND CERTIFIED SAFE FOR PERSONEL & SAFE FOR HOT WORK.
Condition: Unknown
Due 22 April 1998
Resolved 23 April 1998
Engineering
Issued 5 February 1998 Resolved
PUMP OUT FUEL, GAS FREE AND MAKE AVAILABLE FOR INSPECTION #1 DIESEL FUEL TANK TO DETERMINE SOURCE OF FUEL LEAK.
Condition: Unknown
Due 22 February 1998
Resolved 22 February 1998
Engineering
Issued 5 February 1998 Resolved
MAKE PERMANENT REPAIRS TO ON DECK PORT SIDE CONTAINMENT SYSTEM.
Condition: Unknown
Due 6 September 1998
Resolved 10 March 1998
Navigation
Issued 11 July 1997 Resolved
Provide proper charts & publications for area of operation.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997 Resolved
Make necessary repairs to wasted internals in aft peak tanks.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Electrical
Issued 11 July 1997 Resolved
Make proper electrical connections (wiring) on refrigeration compressor motor.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Engineering
Issued 11 July 1997 Resolved
Machinery monitoring panel located in engineroom is suspect. Drawings to be located and full test to be carried out in order to determine proper operation. It appeared that some circuit board cards were missing.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
Replace missing lamps and prove proper operation of wheelhouse alarm panel.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Navigation
Issued 11 July 1997 Resolved
Replace missing and/or damaged fuses & lamp holders fro steering gear control and alarm panel withing wheelhouse. Prove proper operation.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
Renew wasted ladders from main deck.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Deck/Cargo
Issued 11 July 1997 Resolved
Permanently repair damaged control air line to bulk tank valve located in fwd engineroom alleyway.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
Have inflatable liferafts serviced at an USCG approved facility.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Navigation
Issued 11 July 1997 Resolved
Repair & prove proper operation of gyro compass.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
Clean galley and accommodations; fumigate if necessary. Covers must be installed on galley trash cans.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Electrical
Issued 11 July 1997 Resolved
Replace missing motor covers on galley double fridge unit.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
Renew defective seal on freezer door.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
Install suitable means for securing washing machine & cloths dryer from movement at sea.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
Make permanent repairs to pipework within bathrooms in way of wash basin outlets.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Electrical
Issued 11 July 1997 Resolved
Replace covers for accommodation water heater electrical panel.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
Repair Forepeak access ladder in way of wasted & broken connections to bulkhead.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997 Resolved
Repair & demonstrate proper operations of the two valves within the forepeak tank operated by the remote reach rods.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Fire Fighting
Issued 11 July 1997 Resolved
Repair or replace fire main gauge within wheelhouse.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Electrical
Issued 11 July 1997 Resolved
Repair damaged electrical wiring & fittings within chain lockers.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Deck/Cargo
Issued 11 July 1997 Resolved
Electrical connections to anchor windlass motors must be renewed and suitable cable gland fitted. Renew port anchor windlass brake band.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Engineering
Issued 11 July 1997 Resolved
Vents throughout vessel are to be overhauled and repaired in way of missingflame screens and frozen float balls.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997 Resolved
Repair access hatch to port chain locker in way of wasted seal channel. Install new seal on port engineroom escape hatch.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Engineering
Issued 8 March 1996 Resolved
Replace temperature probes for high jacket water temperature larm for port and stbd main engines and test alarms.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Electrical
Issued 8 March 1996 Resolved
Replace protective lighting globes that are missing in engineroom and steering compartment.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Fire Fighting
Issued 8 March 1996 Resolved
Replace necessary fire detection sensors and then test fire detection system for proper operation of all sensors.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Engineering
Issued 8 March 1996 Resolved
Repair and test low lube oil pressure trip on #1 and #2 generators.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Replace expired PFD lights.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Replace improperly serviced liferafts and provide following information to MIO EUROPE: brand, serial #, and copy of last servicing certificate.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Replace hydrostatic releases on both liferafts.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Replace expired EPIRB hydrostaic release.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Electrical
Issued 8 March 1996 Resolved
Repair and test overspeed trips on #1 and #2 generators; trips should be set between 1320 and 1380 RPM.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Engineering
Issued 8 March 1996 Resolved
Repair and test high jacket water temperature alarm for #1 generator.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996 Resolved
Replace missing printed circuit boards for machinery monitoring panel in engineroom.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 26 April 1993 Resolved
PROVIDE 2 OAR LOCKS FOR THE RESCUE BOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Unknown
Issued 26 April 1993 Resolved
PROVE PROPER OPERATION OF #2 S/S GENERATORS OVERSPEED TRIP._x001C_
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Unknown
Issued 26 April 1993 Resolved
PROVE PROPER OPERATION OF THE HEAT DETECTOR LOCATED ABOVE #2 S/S GENERATOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1993
Resolved 26 April 1993
Documentation
Issued 10 January 1992 Resolved
PROVIDE WRITTEN OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Engineering
Issued 10 January 1992 Resolved
REPAIR REMOTE SHUTDOWN FOR STARBOARD MAIN DIESEL ENGINE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Electrical
Issued 10 January 1992 Resolved
REPAIR INOPERATIVE FLOODLIGHT LOCATED ON UPPER STARBOARD CARGO DECK.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Lifesaving
Issued 10 January 1992 Resolved
PROVIDE 25 BLANK CHARGES AND ONE (01) ADDITIONAL ROLL OF SHOTLINE FOR SHOULDER LINE THROWING GUN.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Navigation
Issued 10 January 1992 Resolved
PROVIDE DEVIATION TABLE LOCATED ON BRIDGE.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Deck/Cargo
Issued 10 January 1992 Resolved
REPLACE SOLENOID FOR ANCHOR WINDLASS AND PROVE PROPER OPERATION OF ANCHOR WINDLASS AND PORT AND STARBOARD ANCHORS.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Electrical
Issued 10 January 1992 Resolved
INSTALL TACHOMETERS FOR PORT AND STARBOARD GENERATORS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Fire Fighting
Issued 10 January 1992 Resolved
PROVIDE INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Fire Fighting
Issued 10 January 1992 Resolved
INSTALL 15LB CO2 FIRE EXTINGUISHER TO PAINT LOCKER.
Condition: Unknown
Due 10 January 1992
Resolved 10 January 1992
Deck/Cargo
Issued 18 January 1990 Resolved
PROVIDE SUITABLE PRESSURE RELIEF VALVE AND PROPER HOSE/CONNECTOR FOR TOWING WINCH CONTROL-AIR RECIEVER
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Deck/Cargo
Issued 18 January 1990 Resolved
PROVIDE EVIDENCE OF ANNUAL TESTING (1 1/2 MAWP) OF OIL SERVICE HOSES IN ACCORDANCE WITH 33CFR 156.170
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Deck/Cargo
Issued 18 January 1990 Resolved
CLEAN (DUST FREE) AND MAKE AVAILABLE FOR INTERNAL INSPECTION, SIX BULK MATERIAL TANKS (P-TANKS) BY A MARINE INSPECTOR.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Accommodation/Occupational Safety
Issued 18 January 1990 Resolved
PROVIDE PROPER IN LINE STRAINERS FOR THE 1) BILGE/BALLAST PUMP AND 2) THE BILGE/FIRE PUMP; STARAINERS FOUND MISSING.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Engineering
Issued 18 January 1990 Resolved
DEMONSTRATE PORT MAIN ENGINE REMOTE SHUTDOWN (ON PILOTHOUSE CONSOLE) IN THE PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990
Construction/Loadline
Issued 18 January 1990 Resolved
MAKE TEMPORARY REPAIRS ACCEPTABLE TO COGNIZANT OCMI, TO STARBOARD STERN CORNER AND MAIN DECK INTERSECTION.
Condition: Unknown
Due 18 January 1990
Resolved 18 January 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.