MAURY USCG vessel records Sign in
← All vessels

OCEANSTAR

OCEANSTAR is a 1980 passenger vessel (inspected). The Coast Guard has recorded 99 inspections since 1985, most recently in May 2026, along with 191 deficiencies and 1 casualty investigation in 2022.

Records from 1985 to 2026. Most recent: inspection, 8 May 2026.

Built
1980
Last inspected
8 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9468
Flag
UNITED STATES
368443320
Maury page id
psix-52182

Inspections, by type

…with no type recorded13
Years with a record 39 calendar years (1985–2026)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 19.6 ft × 4.2 ft
Registered tonnagegross 7 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNKNOWN · HONOLULU, HI, UNITED STATES · built 1980
Hull materialWood
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKEWALO BASIN HARBOR, HI
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 3 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Regulatory (Subpart C or D), Gross Ton
7 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6388MMSI 368443320 · active · compulsorily equipped · granted 21 November 2025, expires 21 November 2035
WDH9468MMSI 367668380 · expired · compulsorily equipped · granted 22 April 2015, cancelled 24 May 2025 · licensed under a name not among this hull’s recorded names (not shown)
WYQ8379MMSI 367305870 · expired · compulsorily equipped · granted 31 July 2007, cancelled 16 December 2017 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 99

8 May 2026 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8316768
16 May 2025 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8137920
17 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8095349
11 March 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7853690
29 August 2023 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7786533
11 April 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7659208
13 March 2023 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7622474
1 June 2022 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7465807
25 May 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7460638
14 March 2022 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408301
16 June 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7227658
6 April 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7170112
22 March 2021 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7160946
8 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6971517
19 August 2019 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6788573
7 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6678917
1 April 2019 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6653805
30 April 2018 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402897
20 July 2016 Deadweight Survey · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5947694
30 October 2014 Drydock Exam · Construction Oversight · Initial Certification · Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5019800
9 January 2012 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4221776
22 September 2011 Hull Examination · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4151848
10 November 2010 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3888389
29 January 2009 Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3426298
5 January 2009 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3392920
25 November 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3381932
16 October 2007 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3081325
1 May 2007 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2920277
24 October 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2807433
21 September 2006 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2784218
21 September 2006 Type not recorded
No type recorded · USCGC AHI (WPB 87364) · USCG Oceania District (CGD-O) · Activity 2787748
20 September 2006 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2806775
29 November 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2543045
5 October 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2507687
8 December 2004 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2251648
8 January 2004 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1975725
28 December 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1970313
14 July 2003 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1860754
12 June 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1816216
19 August 2002 Deficiency Check · Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1650474
12 December 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1477041
27 September 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1074274
15 August 2001 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1069023
13 July 2001 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1465050
24 August 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 822368
20 July 2000 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1381969
6 March 2000 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1046291
15 December 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451483
20 July 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365308
26 August 1998 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 798260
19 August 1998 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 795655
23 July 1998 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 796365
23 July 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1406358
24 December 1997 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1372069
29 July 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1364276
2 June 1997 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1109269
14 August 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355931
2 April 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1355677
12 February 1996 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 879133
21 December 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357428
15 September 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1184259
8 August 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 885949
2 August 1995 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357298
12 July 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 380544
12 May 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 661264
15 March 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 77512
3 October 1994 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 864408
10 August 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1356788
27 December 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353499
27 August 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1158688
16 August 1993 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1451886
10 August 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1265181
25 June 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1134141
18 May 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1256958
11 September 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 945595
13 August 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937387
28 November 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 905915
17 September 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235371
14 August 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1220479
1 February 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1240720
12 December 1989 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931316
29 October 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 895385
16 October 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345852
15 August 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1349884
6 February 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341655
15 November 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 893604
11 July 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1036088
27 June 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1341594
6 May 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1039600
16 March 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988252
11 August 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1340870
4 May 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1017979
19 August 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987110
14 January 1986 Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1302040
10 December 1985 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298069
28 August 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 986577
21 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 984331
14 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1291941
9 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982087

Deficiency record · 191

03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2026 Resolved
Each collision bulkhead required by § 179.210, must be constructed in accordance with § 179.320, except that a collision bulkhead: Must not be fitted with any type of penetration or opening except penetrations may be made if they are located as high and as far inboard as practicable and they have a means to make them watertight. Watertight inspection covers removed from collision bulkheads on both hulls. Reinstall watertight inspection covers on both hulls to satisfaction of attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2026
Resolution: Covers installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 May 2025 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Onboard Radio Station Authorization is expired. Vessel to provide an updated Radio Station Authorization. 47 CFR 80.13(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2025
Resolved 21 November 2025
Resolution: Received FCC Radio Station Authorization.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 April 2023 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Ammonia inhalants in first aid kit expired. Replace ammonia inhalants. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 28 April 2023
Resolution: Vessel rep purchased new ammonia inhalants.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Electrical wiring underneath operating station has several dead end wires and one improperly spliced wire connection. Properly remove dead end wires and remove and replace splice with proper wire splicing to prevent potential shock or fire hazards. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 28 April 2023
Resolution: Vessel rep removed dead end wires and properly spliced the wire.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 April 2023 Resolved
On a vessel of at least 26 ft. in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Vessel's visual and audible alarms are secured with tape. Permanently mount visual alarms and audible indicators at operating station. 46 CFR 182.530 (a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 28 April 2023
Resolution: Vessel rep permanently mounted the visual alarms at the operating station.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2023 Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with 47 CFR 80.59 once every five years. Vessel does not have a valid Safety Radiotelephony Certificate. Provide Radiotelephony Certificate. 47 CFR 80.903
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 4 May 2023
Resolution: Vessel POC emailed copy of new Safety Radiotelephony Cert.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 April 2023 Resolved
Equipment and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Bolts holding the swim ladder have backed out and need to be tightened back down. 46 CFR 176.800 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 23 June 2023
Resolution: Vessel owner tightened bolts to swim ladder.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 April 2023 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. One of the captains for the vessel could not provide their medical certificate. Provide proof of medical certificate. 46 CFR 15.401 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2023
Resolved 29 August 2023
Resolution: Recieved photo of new medical certificate for the captain missing theirs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2022 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Provide satisfactory evidence of a chemical testing program. 46 CFR 16.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 22 April 2022
Resolution: Received an email picture of the vessel's maritime consortium enrollment.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 March 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel's Certificate of Documentation does not have a Coastwise endorsement. 46 CFR 67.313
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 22 April 2022
Resolution: Received email verification of new COD.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 March 2022 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting drills and training. 46CFR185.524(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 2 August 2022
Resolution: Vessel provided email proof of logbook.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 March 2022 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel show proof of Maintenance logbook to the satisfaction of the Marine inspector. 46CFR176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 March 2022
Resolved 12 April 2022
Resolution: Received email of service reports from Ali'i Fire Protection Co., Ltd. as verification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2022 Resolved
Child size life jackets equal to 10% of the number of persons permitted on board must be provided. Vessel only has 5 child life jackets and is required to have 6 per the COI. Vessel corrected deficiency on the spot. 46 CFR 182.458(b)
Action required: 10 - Deficiency Rectified
Resolved 14 March 2022
Resolution: Vessel replaced 1 child life jacket on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 March 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel had 6 non serviceable life jackets. Vessel corrected deficiency on the spot. 46 CFR 182.458(b)
Action required: 10 - Deficiency Rectified
Resolved 14 March 2022
Resolution: Vessel replaced 6 adult life jackets on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 April 2021 Resolved
Vessel must be provided with satisfactory arrangement for draining any watertight compartment. Vessel was unable to demonstrate operation of the port and stbd electric bilge pumps. Prove proper operation of the bilge pumps to attending marine inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Bilge pumps operated satisfactory.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 April 2021 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Port and stbd bilge audible and visual alarms are not operational. Demonstrate proper operation to marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Alarms tested satisfactory
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 April 2021 Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. Port running light and vessel anchor light were not secured to the vessel. Provide navigation lights that are in compliance with the Navigation Rules and properly mounted to the vessel.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2021
Resolution: Lights adequately secured to hull.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 April 2021 Resolved
A hatch exposed to the weather must be watertight. Gasket material for each of the vessel's forward deck hatches does not provide a watertight seal and allows ingress of water. Properly renew hatch gasket material to prevent ingress of water.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 April 2021
Resolution: Gasket material renewed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 April 2021 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit missing wire splint.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 13 April 2021
Resolution: Purchased new wire splint for first aid kit.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 8 June 2020 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Two of vessels three required fire extinguishers were below the required charge. 46 CFR 176.810(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2020
Resolved 10 June 2020
Resolution: Vessel got extinguishers recharged by Fire Systems LLC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2020 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. One of vessels life jackets retro reflective tape in need of replacement. 46 CFR 176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2020
Resolved 27 June 2020
Resolution: Vessel renewed life jacket retro reflective with approved SOLAS tape.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 1 May 2018 Resolved
Replace 1 unserviceable adult life jacket with proper approval IAW subchapter Q. Passenger count reduced to 48 until this is corrected.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Received email proof of deficiency correction.
Lifesaving › Lifebuoys › Serviceable
Issued 1 May 2018 Resolved
Replace worn ring life buoy and label
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Received email proof of deficiency correction.
Fire Fighting › Portable CO2 Fire Extinguisher › Marine Type Label
Issued 1 May 2018 Resolved
Provide 2 BII and 1 BI as required on COI
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Received email proof of deficiency correction.
Engineering › Gasoline (Outboard) › General
Issued 1 May 2018 Resolved
Label locations in which fuel shutoff valves are placd.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 21 May 2018
Resolution: Received email proof of deficiency correction.
Engineering › Fuel Oil Service System › Hose
Issued 9 November 2010 Resolved
Renew gasoline fuel hose and primer bulbs.
Due 10 December 2010
Resolved 2 December 2010
Electrical › Electrical Distribution System (service) › Cable
Issued 9 November 2010 Resolved
Provide chafe protection for breaker pannel wiring. 46CFR183.10-20(f)
Due 10 December 2010
Resolved 2 December 2010
Electrical › Electric Generation Source (service) › Generator
Issued 9 November 2010 Resolved
Provide generator name plate IAW 46 CFR 183.10-5(a)
Due 10 December 2010
Resolved 13 December 2010
Resolution: Received pictures showing data plate and installation of data plate.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 9 November 2010 Resolved
Renew 5 adult and 1 childs lifejacket vessel is limited to 60 people until resolved 46CFR180.71
Due 10 December 2010
Resolved 2 December 2010
Lifesaving › Lifebuoys › Serviceable
Issued 9 November 2010 Resolved
Renew life line on ring bouy.
Due 10 December 2010
Resolved 2 December 2010
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 November 2010 Resolved
Mount fresh water pump.
Due 10 December 2010
Resolved 2 December 2010
Engineering › Bilge Water Management System › Hose
Issued 9 November 2010 Resolved
Provide double hose clamps on bilge system hoses.
Due 10 December 2010
Resolved 2 December 2010
Construction/Loadline › Penetrations › Gasket
Issued 9 November 2010 Resolved
Renew gaskets on forward hatches. 46CFR171.114
Due 10 December 2010
Resolved 2 December 2010
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 November 2010 Resolved
Renew port side net frame as original.
Due 17 December 2010
Resolved 2 December 2010
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 November 2010 Resolved
Update PFD markings to reflect actual count.
Due 10 December 2010
Resolved 2 December 2010
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 January 2009 Resolved
Found generator fuel tank not in compliance with 46 CFR 182.440. Tank met ABYC standards for vessel with 12 pax. Vessel carries 49 pax. Replace tank to conform to same.
Due 7 March 2009
Resolved 19 March 2009
Resolution: Tank installed and operationally tested/leak check for five minutes.
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 November 2008 Resolved
Found bilge alarm float switch located in the stbd bow not fastened to the boat. Refasten stbd bow bilge alarm.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Alarm securley fastened to the boat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 November 2008 Resolved
Found stbd running light inoperable. Prove proper operation of the stbd running light.
Due 20 December 2008
Resolved 17 December 2008
Resolution: New stbd running light installed and operating sat.
Documentation › Certificates/Documents › FCC SSL
Issued 25 November 2008 Resolved
Found FCC Safety Radio Certificate expired. Renew certificate.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Rep provided proof of current FCC Safety Cert.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 November 2008 Resolved
Found life jacket stowage not properly marked regarding size and number. Make markings to agree with requirement.
Due 20 December 2008
Resolved 19 December 2008
Resolution: Sighted proper life jacket stowage and marking.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 25 November 2008 Resolved
Found portable BII fire extinguisher excessively rusted and indicating an overcharge condition. Replace this portable fire extinguisher.
Due 2 December 2008
Resolved 2 December 2008
Resolution: Owner purchased new portable extinguisher and provided proof of purchase. Witnessed installation of same on 17DEC08.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 25 November 2008 Resolved
Found forward anchor line chaffed. Replace anchor line.
Due 20 December 2008
Resolved 17 December 2008
Resolution: New line installed with splice vice bowline knot.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 November 2008 Resolved
The port amidships watertight bulkhead has non-watertight penetrations a piping penetrations. Seal same to make watertight.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Penetrations sealed.
Engineering › Bilge Water Management System › Piping
Issued 25 November 2008 Resolved
Found bilge line/pipe joint in the forward port space loose from apparent abuse (repeatedly stepped on). Re-braze/solder union to bilge line. Recommend installing guard to protect bilge line from future abuse.
Due 20 December 2008
Resolved 19 December 2008
Resolution: Sighted proper repair including addition of a wooden step over the bilge line to prevent recurrence of the problem caused by crew stepping on the bilge line when entering the space.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 November 2008 Resolved
Found approx 07 PFDs requiring remarking with retro-reflective tape.
Due 20 December 2008
Resolved 25 November 2008
Resolution: PFDs were remarked with retroreflective tape prior to completion of inspection.
Stability › Weathertight Integrity › General
Issued 25 November 2008 Resolved
Found substantial amount of water in the wing area (between hulls) under the deck forward of the cabin windows. Determine source of water and seal to prevent further water ingress.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Vessel rep indicated that water was discovered to be entering the space from loose and improperly sealed hand rail fasteners. Space was dried out and fasteners were tightened and resealed.
Construction/Loadline › Structures › Manhole
Issued 25 November 2008 Resolved
Found wood rot under stbd bow hatch coaming. Remove angel hair and seal.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Rot removed and area resealed.
Construction/Loadline › Penetrations › Gasket
Issued 25 November 2008 Resolved
Found worn/rotted gaskets on the port and stbd forward hatches. Replace same.
Due 20 December 2008
Resolved 17 December 2008
Resolution: New gaskets installed.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 25 November 2008 Resolved
the emergency broadcast placard is not located where it can be seen from the operating station. Relocate it to where it can be more easily seen.
Due 20 December 2008
Resolved 17 December 2008
Resolution: Placard was reaffixed on operating station to the left of the wheel in plain sight.
Navigation › Piloting/Steering › Marine Charts
Issued 8 November 2007 Resolved
Provide updated marine chart and light list pages for the vessel's operational area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Sighted new Kaneohe Bay chart and proper light list pages for area of operation.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 November 2007 Resolved
Provide a complete 1st aid kit including replenishment of expired items such as aspirin and eye wash in the existing kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Sighted updated 1st aid kit.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 16 October 2007 Resolved
Repair fractured wooden port motor mount. (Worklist noted during drydock)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Sighted completed repair. Motor satisfactorily mounted.
Construction/Loadline › Hull › Stiffener
Issued 16 October 2007 Resolved
Treat deck support member above the port water tank for possible termite damage, and clean and treat deck support in port aft compartment for minor signs of dry rot (angel fir). (Worklist items discovered during drydock inspection)
Action required: 705 - Other - as specified
Resolved 21 November 2007
Resolution: Sighted treated deck support member.
Fire Fighting › Fire Pumps › Pressure
Issued 16 October 2007 Resolved
Demonstrate proper operation of fire and bilge pump. Discharge piping port and starboard wasted in both hulls possibly due to the use of dissimilar metals (stainless steel and bronze), in the system. System operates at reduced pressure. (Worklist item brought to inspector's attention at the beginning of the drydock inspection)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Witnessed satisfactory operation of the fire/bilge pump.
Construction/Loadline › Hull › Double Hull
Issued 16 October 2007 Resolved
Grind through FRP sheath to wood and determine if fractured sheath 40" from port bow at waterline and 22" form the bottom affects the structure of the hull. (Worklist item discovered during drydock inspection)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Hull faired and re-sheathed in this area.
Construction/Loadline › Hull › Double Hull
Issued 16 October 2007 Resolved
Grind FRP sheath to good wood and re-sheath port hull amidships inboard 1" from bottom where water appears to have ingress behind the FRP sheath. (Worklist item discovered during drydock inspection.)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Hull faired and resheathed in this area.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 16 October 2007 Resolved
Provide 1 additional child and 6 additional adult lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Sighted newly acquired and properly marked child and adult lifejackets bringing vessel to it''s required quota per the COI.
Lifesaving › Buoyant Smoke Signals › General
Issued 16 October 2007 Resolved
Provide (3) orange smoke signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: Sighted (3) new smoke floats aboard vessel.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 16 October 2007 Resolved
Post EAP "hotline" number aboard vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2007
Resolution: EAP Hotline number posted on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 16 October 2007 Resolved
Establish an acceptable method for determining when to conduct and who to screen for random drug and alcohol testing. Date pending appointment with company's DER.
Action required: 705 - Other - as specified
Due 7 December 2007
Resolved 21 November 2007
Resolution: Educated company''s designated employer representative regarding methodology for selecting the time and person for random drug screening.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 21 September 2006 Resolved
Provide material for DAPI audit prior to carrying passengers.
Condition: Unknown
Due 26 September 2006
Resolved 18 October 2006
Engineering › Bilge Water Management System › Interface Detector
Issued 21 September 2006 Resolved
Prove proper operation of high water alarms prior to carrying passengers.
Condition: Unknown
Due 26 September 2006
Resolved 18 October 2006
Fire Fighting › Fire Pumps › Capacity
Issued 21 September 2006 Resolved
Prove proper operation of fire pump IAW 46CFR181.300. Pump must have pressure gauge, remote operation from operating station and provide 50 GPM.
Condition: Unknown
Due 26 September 2006
Resolved 18 October 2006
Construction/Loadline › Structures › Transverse Bulkhead
Issued 21 September 2006 Resolved
Repair collsion bulkheads IAW CG approved plans. Access hatches removed.
Condition: Unknown
Due 26 September 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 September 2006 Resolved
Provide metal fasteners for wire runs.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 September 2006 Resolved
Prove proper operation of Amp and voltage gauges.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 September 2006 Resolved
Prove proper operation of gauges located at helm.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 September 2006 Resolved
Make proper repairs to distruibution panel box.
Condition: Improper/Lack of Maintenance
Due 15 October 2006
Resolved 18 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 September 2006 Resolved
Remove or properly repair dead end wires located throughout vessel.
Condition: Improper/Lack of Maintenance
Due 15 October 2006
Resolved 18 October 2006
Lifesaving › Lifejacket/PFD (Type II) › Condition
Issued 21 September 2006 Resolved
Provide (2) CG approved adult lifejackets.
Condition: Improper/Lack of Maintenance
Due 25 September 2006
Resolved 18 October 2006
Stability › Severe Wind/Roll › General
Issued 21 September 2006 Resolved
Provide rigging survey.
Condition: Improper/Lack of Maintenance
Due 15 October 2006
Resolved 18 October 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 21 September 2006 Resolved
Provide crew CPR cards for 50% of crew.
Condition: Improper/Lack of Maintenance
Due 15 October 2006
Resolved 18 October 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 September 2006 Resolved
Provide tide tables and tidal crrent tables.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 September 2006 Resolved
Make proper repairs to fractured stanchion bases.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 21 September 2006 Resolved
Provide clousres for stbd generator space.
Condition: Unknown
Due 15 October 2006
Resolved 18 October 2006
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 September 2006 Resolved
Provide anchor and line.
Condition: Unknown
Due 25 September 2006
Resolved 18 October 2006
Engineering › Fuel Oil Service System › Piping
Issued 21 September 2006 Resolved
Provide fuel lines for generator IAW 46CFR182.458.
Condition: Improper Installation
Due 15 October 2006
Resolved 18 October 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 October 2005 Resolved
Provide (2) adult PFD's. Passenger count is reduced to 67 until corrected.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Provided (2) adult PFD''s. Passenger count authorized for 69.
Engineering › Bilge Water Management System › Not Operational
Issued 5 October 2005 Resolved
Prove operation of bilge systems.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2005
Resolved 8 November 2005
Resolution: Proved operation of bilge systems.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 October 2005 Resolved
Provide (2) portable lights.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Provided (2) portable lights.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 October 2005 Resolved
Label high level alarms at operating station.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Labeled high level alarms at operating station.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 October 2005 Resolved
Label locations of adult and child PFD's.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Labeled locations of adult and child PFD''s.
Fire Fighting › Fire Bucket › Lanyard
Issued 5 October 2005 Resolved
Label w/ vessel name and attach lanyards to fire buckets.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Labeedl w/ vessel name and attached lanyards to fire buckets.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 October 2005 Resolved
Renew retro tape and line on ring buoy.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Provided new ring buoy with retro tape & line.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 5 October 2005 Resolved
Relocate or remove canopy over operating station to allow visibility of stern light.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Relocates canopy over operating station to allow visibility of stern light during dusk/evening ops.
Stability › Severe Wind/Roll › General
Issued 5 October 2005 Resolved
Provide rigging survey.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Sail taken down and off vessel. Rigging to be removed from vessel during scheduled NOV05 dry-dock per Master''s statement.
Stability › Watertight Integrity › General
Issued 5 October 2005 Resolved
Secure all watertight hatches.
Due 30 November 2005
Resolved 8 November 2005
Resolution: Secured all watertight hatches.
Documentation › Certificates/Documents › Stability Letter
Issued 8 December 2004 Resolved
Post vessel stability letter IAW 46 CFR 176.306.
Due 22 December 2004
Resolved 17 December 2004
Resolution: Posted vessel stability letter IAW 46 CFR 176.306.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 8 December 2004 Resolved
Mark lifejackets with vessel name IAW 46 CFR 185.604(b).
Due 22 December 2004
Resolved 10 December 2004
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 8 December 2004 Resolved
Mark lifejackets with Type I reflective material as needed IAW 46 CFR 185.604(h).
Due 22 December 2004
Resolved 10 December 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 8 December 2004 Resolved
Provide (4) adult and (2) children lifejackets IAW 46 CFR 180.71. Vessel passenger count reduced by (6) until corrected.
Due 22 December 2004
Resolved 10 December 2004
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 December 2004 Resolved
Post lifejacket donning placards for all types of PFD's carried on vessel IAW 46 CFR 185.516.
Due 22 December 2004
Resolved 17 December 2004
Resolution: Posted lifejacket donning placards for all types of PFD''s carried on vessel IAW 46 CFR 185.516.
Documentation › Markings/Placards › Capacity Marking
Issued 8 December 2004 Resolved
Label upper deck "no passengers allowed" as per vessel stability letter IAW 46 CFR 185.602(g).
Due 22 December 2004
Resolved 17 December 2004
Resolution: Labeled upper deck "no passengers allowed" as per vessel stability letter IAW 46 CFR 185.602(g).
Engineering › Bilge Water Management System › Not Operational
Issued 8 December 2004 Resolved
Prove operation of high level audible and visible bilge alarms IAW 46 CFR 182.530.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 8 December 2004 Resolved
Remove all dead end/unused wires from generator fuel tank space IAW 46 CFR 183.340.
Due 22 December 2004
Resolved 17 December 2004
Resolution: Removed all dead end/unused wires from generator fuel tank space IAW 46 CFR 183.340.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 December 2004 Resolved
Provide first-aid kit in compliance with 46 CFR 184.710.
Due 22 December 2004
Resolved 17 December 2004
Resolution: Provided first-aid kit in compliance with 46 CFR 184.710.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 8 December 2004 Resolved
Mark lifebuoy with vessel name IAW 46 CFR 185.604(a).
Due 22 December 2004
Resolved 17 December 2004
Resolution: Marked lifebuoy with vessel name IAW 46 CFR 185.604(a).
Engineering › Bilge Water Management System › Pump
Issued 8 December 2004 Resolved
Provide portable bilge pump IAW 46 CFR 182.520(b).
Due 22 December 2004
Resolved 17 December 2004
Resolution: Provided portable bilge pump IAW 46 CFR 182.520(b).
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 December 2004 Resolved
Provide (2) crewmembers, as per COI, to conduct sat. M.O.B. and fire drills IAW 46 CFR 185.520 and 185.524.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 December 2004
Communications › Alarms/Indicators
Issued 12 June 2003 Resolved
Prove Bilge high water alarms for the port side hull. LEGACY COMPONENT DESC: Bilge Alarm
Due 13 July 2003
Resolved 14 July 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 12 June 2003 Resolved
Provide marking for lifejacket stowage as per 46 CFR 185.604 LEGACY COMPONENT DESC: Storage
Due 13 July 2003
Resolved 14 July 2003
Engineering › Gasoline Engine (propulsion)
Issued 12 June 2003 Resolved
Provide permanent means to fix outboard Engines in position.
Due 13 July 2003
Resolved 14 July 2003
Navigation › Collision/Grounding Avoidance
Issued 12 June 2003 Resolved
Prove Navigation lights. LEGACY COMPONENT DESC: Navigation Lights
Due 13 July 2003
Resolved 14 July 2003
Navigation › Collision/Grounding Avoidance
Issued 12 June 2003 Resolved
Provide rules of the road book.
Due 13 July 2003
Resolved 14 July 2003
Documentation › Markings/Placards
Issued 28 August 2002 Resolved
Make vessels name and hailing port legible on stern.
Due 6 September 2002
Resolved 9 October 2002
Engineering › Bilge Water Management System
Issued 19 August 2002 Resolved
Install bilge high level alarms IAW 46CFR182.115 & 46CFR182.530. LEGACY COMPONENT DESC: Alarm (high level)
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 9 October 2002
Fire Fighting › Fire Hoses
Issued 19 August 2002 Resolved
Provide fire and nozzle that meet the requirements of 46CFR181.10. LEGACY COMPONENT DESC: Connections
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Engineering › Bilge Water Management System
Issued 19 August 2002 Resolved
Install strainers on all bilge suctions IAW 46CFR182.25-5. LEGACY COMPONENT DESC: Strainer
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 9 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 19 August 2002 Resolved
Install missing chain or cable at deck rail aft of the operating station. 46CFR177.35-1 LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 19 August 2002 Resolved
Repair cracked deck railing port side fwd at base. 46CFR177.35-1 LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Engineering › Steering Gear System
Issued 19 August 2002 Resolved
Repair steering system helm assembly to prevent wheel from falling off. 46CFR176.25-35 LEGACY COMPONENT DESC: Helm Assembly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Engineering › Steering Gear System
Issued 19 August 2002 Resolved
Repair steering system linkage at hydraulic ram by removing excessive play in system. (check pin and bushing for wear) LEGACY COMPONENT DESC: Linkage
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Electrical › Electrical Distribution System (service)
Issued 19 August 2002 Resolved
Provide missing cover on junction box port side adjacent to the water heater. 46CFR183.10-20 (f) (1) LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 19 August 2002 Resolved
Install missing cover at shore power connection. 46CFR183.10-20 (f) (1) LEGACY COMPONENT DESC: Receptacle Outlet
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Electrical › Electric Generation Source (service)
Issued 19 August 2002 Resolved
Install generator meters IAW 46CFR183.10-5 (g). (frequency meter damaged) LEGACY COMPONENT DESC: Panelboard
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Electrical › Electrical Distribution System (service)
Issued 19 August 2002 Resolved
Provide permanent wire connections in port side head IAW 46CFR183. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Personnel › Training
Issued 19 August 2002 Resolved
Provide proof of First Aid/CPR certification for at least 50% of the crew. NVIC 1-91 LEGACY COMPONENT DESC: First Aid/CPR
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Documentation › Safety/Response Plans/Programs
Issued 19 August 2002 Resolved
Post emergency instruction list IAW 46CFR185.510. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 28 August 2002
Operations/Management › Drills/Instruction
Issued 19 August 2002 Resolved
Conduct fire and Man Ovbd drills. LEGACY COMPONENT DESC: Fire/Man Ovbd
Action required: 705 - Other - as specified
Due 27 August 2002
Resolved 9 October 2002
Lifesaving › Lifejacket/PFD (General)
Issued 19 August 2002 Resolved
Install retro reflective tape on at least 09 of the 17 life jackets that were failed due to loose or missing retro tape. 46CFR180.25-25 The number of passengers are reduced to 56 until the lifejackets are repaired or renewed. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 9 October 2002
Personnel › Certificates/Documents/Licenses
Issued 19 August 2002 Resolved
Conduct fire and man overboard drills.
Due 27 August 2002
Resolved 9 October 2002
Electrical › Electrical Distribution System (service)
Issued 19 August 2002 Resolved
Provide cover for electrical box in galley cabinet.
Due 6 September 2002
Resolved 9 October 2002
Communications › Visual Communication
Issued 19 August 2002 Resolved
Post a no passengers allowed on the upper deck above ladder stbd side main deck.
Due 6 September 2002
Resolved 9 October 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 19 August 2002 Resolved
Make Lifejackets accessible ( remove from aft hull compartments). LEGACY COMPONENT DESC: Storage
Due 6 September 2002
Resolved 9 October 2002
Construction/Loadline › Structures
Issued 9 January 2002 Resolved
Address rotten wood on starboard forward hatch aft end. LEGACY COMPONENT DESC: Hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2002
Resolved 9 January 2002
Construction/Loadline › Hull
Issued 9 January 2002 Resolved
Provide plans and complete repairs to rotted structural wood in port stem and bow. LEGACY COMPONENT DESC: Port Stem
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 January 2002
Resolved 9 January 2002
Construction/Loadline › Penetrations
Issued 9 January 2002 Resolved
Replace spool piece and exhaust hose for starboard generator. LEGACY COMPONENT DESC: Generator Spool Piece
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2002
Resolved 9 January 2002
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 January 2002 Resolved
Replace valve for starboard generator intake.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 9 January 2002
Resolved 9 January 2002
Construction/Loadline › Hull
Issued 9 January 2002 Resolved
Provide proof vessel rigging will be replaced prior to 30JAN2002. LEGACY COMPONENT DESC: Rigging
Action required: 705 - Other - as specified
Due 9 January 2002
Resolved 9 January 2002
Engineering
Issued 13 July 2001 Resolved
Provide copper or other suitable material for generator fuel line in accordance with 46 CFR 182.455.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Navigation
Issued 13 July 2001 Resolved
Prove proper operation of engine RPM gauges in accordance with 46 CFR 182.410.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Documentation
Issued 13 July 2001 Resolved
Provide an FCC Marine Operator Permit for [name withheld] in accordance with 47 CFR.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Navigation
Issued 13 July 2001 Resolved
Provide navigation lights in accordance with COLREGS and 46 CFR 183.420. _x001C_Vessel restricted from operating during periods of limited visibility.
Condition: Unknown
Due 13 July 2001
Resolved 13 July 2001
Lifesaving
Issued 20 July 2000 Resolved
Replace retrograde material on (18) adult lifejackets and mark (2) adult and (3) children's life jackets with vessel name IAW 46CFR 185.604(h).
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Electrical
Issued 20 July 2000 Resolved
Re-wire lights in heads IAW 46CFR 183.340.
Condition: Unknown
Due 20 July 2000
Resolved 20 July 2000
Construction/Loadline
Issued 15 December 1999 Resolved
Make forward hatches weathertight iaw 46CFR 179.360.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Engineering
Issued 15 December 1999 Resolved
Permanently remount ventilation piping for generator compartment iaw 46CFR 182.465(d).
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Electrical
Issued 15 December 1999 Resolved
Remove deadended wires and secure wiring in junction box in port hull, second compartment. Cover junction box. 46CFR 183.210.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Accommodation/Occupational Safety
Issued 20 July 1999 Resolved
Effect repairs to Port rail attachment points and Stbd rail welding at embarkation point. 46CFR 177.900
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Construction/Loadline
Issued 20 July 1999 Resolved
Replace bottom piece of bridle for forward stay prior to operating in the sailing mode. 46CFR 177.330
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 20 July 1999 Resolved
Add triangular cravat to first aid kit iaw guidance found in 46CFR 160.041-4.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 20 July 1999 Resolved
Attach 60' of line to ring life buoy and if attached light is retained, attach to ring bouy with 3' lanyard and detachable clip. (IAW 46CFR180.70)
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Lifesaving
Issued 20 July 1999 Resolved
Demonstrate evidence of performance of drills required IAW 46CFR185.520 and185.524.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 20 July 1999 Resolved
Replace wire nuts in vicinity of STBD head (pump) and float switch in generator tank space with proper wire connectors, IAW 46CFR183.340(g).
Condition: Unknown
Due 20 August 1999
Resolved 3 September 1999
Engineering
Issued 20 July 1999 Resolved
Replace chaffed fuel hose on STBD engine. 46CFR 182.720.
Condition: Unknown
Due 6 August 1999
Resolved 6 August 1999
Electrical
Issued 23 July 1998 Resolved
Relocate battery located under steering console or provide adequate ventalation of explosive gases to prevent explosive concentration of battery gases.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Fire Fighting
Issued 23 July 1998 Resolved
Provide proof of required annual servicing as per NFPA 10.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Electrical
Issued 21 December 1995 Resolved
TEST PORTABLE GENERATOR AND BILGE SYSTEM DAILY UNTIL INSTALLATION OF PERMANENT GENERATOR. ANY DEFICIENCIES ARE TO BE REPORTED TO MSO HONOLULU IMMEDIATELY. NO PASSENGERS MAY BE CARRIED IF AT ANY TIME BILGE SYSTEM OR PORTABLE GENERATOR IS NOT OPERATING AS TESTED BY CG INSPECTOR ON 04JAN96.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Electrical
Issued 21 December 1995 Resolved
INSTALL APPROVED MAIN GENERATOR ON VESSEL. TESTING OF GENERATOR INCLUDING EXAMINATION OF INSTALLATION AND TEST OF VESSEL'S BILGE PUMP SYSTEM TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING CG INSPECTOR PRIOR TO REMOVALOF CURRENT PORTABLE GENERATOR.
Condition: Unknown
Due 21 December 1995
Resolved 21 December 1995
Lifesaving
Issued 2 August 1995 Resolved
PROVIDE REFLECTIVE TAPE FOR 8 ADULT AND 3 CHILD PFD'S AND REPAIR DAMAGE COATING ON 5 ADULT PFD'S. VSL LIMITED TO 56 ADULTS AND 4 CHILDREN UNTIL ITEM IS CORRECTED.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Fire Fighting
Issued 2 August 1995 Resolved
PROVIDE PROPER MOUNTING BRACKETS FOR PORTABLE B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 August 1995
Resolved 2 August 1995
Unknown
Issued 10 August 1994 Resolved
SHOW COMPLIANCE WITH DRUG TESTING REQUIREMENTS OF 46 CFR PART 16.
Condition: Unknown
Due 8 September 1994
Resolved 13 September 1994
Navigation
Issued 10 August 1994 Resolved
REPLACE BADLY CRAZED COMPASS DOME.
Condition: Unknown
Due 8 September 1994
Resolved 13 September 1994
Fire Fighting
Issued 10 August 1994 Resolved
SERVICE FIRE EXTINGUISHER IN FORWARD PORT BATTERY COMPARTMENT.
Condition: Unknown
Due 8 September 1994
Resolved 13 September 1994
Electrical
Issued 10 August 1994 Resolved
REMOVE ALL DEAD END WIRES THROUGHOUT VESSEL.
Condition: Unknown
Due 8 September 1994
Resolved 13 September 1994
Lifesaving
Issued 10 August 1994 Resolved
MAKE REPAIRS TO PAINTERS FOR BUOYANT APPARATUS. ATTACH WEAK LINKS AND_x001C_ LIGHT AND PROPERLY STOW PAINTER. ROUTE RESTRICTED TO NOT MORE THAN ONE MILEFORM SHORE UNTIL COMPLETED.
Condition: Unknown
Due 8 September 1994
Resolved 26 August 1994
Construction/Loadline
Issued 10 August 1994 Resolved
PROVIDE SUITABLE STRAINERS FOR ALL BILGE SUCTIONS.
Condition: Unknown
Due 8 September 1994
Resolved 2 September 1994
Lifesaving
Issued 10 August 1994 Resolved
REMOVE ALL HAZARDOUS MATERIALS FORM HOLDS OF VESSEL; FLAMMABLES, COMBUSTIBLES, AND OXIDIZERS.
Condition: Unknown
Due 24 September 1994
Resolved 30 August 1994
Lifesaving
Issued 10 August 1994 Resolved
REPLACE BATTERY IN WATERLIGHT OF RINGBOUY. VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL COMPLETED.
Condition: Unknown
Due 8 September 1994
Resolved 26 August 1994
Lifesaving
Issued 10 August 1994 Resolved
REPLACE RING BOUY AND LINE.
Condition: Unknown
Due 26 August 1994
Resolved 26 August 1994
Engineering
Issued 10 August 1994 Resolved
REPAIR OR REPLACE QUICK DISCONNECT IN FUEL LINE TO GAS TANK.
Condition: Unknown
Due 8 September 1994
Resolved 26 August 1994
Navigation
Issued 10 August 1994 Resolved
REPLACE STARBOARD AND MASTHEAD RUNNING LIGHTS. VESSEL RESTRICTED TO DAYLIGHT OPERATION UNTIL REPAIRS ARE COMPLETED.
Condition: Unknown
Due 8 September 1994
Resolved 26 August 1994
Electrical
Issued 27 December 1993 Resolved
PROVIDE QUICK DISCONNECT FOR GROUND WIRE ON FUEL TANK FOR OUTBOARD ENGINES.
Condition: Unknown
Due 25 January 1994
Resolved 25 January 1994
Engineering
Issued 27 December 1993 Resolved
MAKE THE ENCLOSED OUTBOARD ENGINE FUEL TANK SPACE OPEN TO ATMOSPHERE OR PROVIDE POWER VENTILATION AS REQUIRED BY 46 CFR 182.15-45, AND A FIXED FIREEXTINGUISHING SYSTEM IAW 46 CFR 181.20-1(a)(1)._x001C_
Condition: Unknown
Due 6 February 1994
Resolved 2 February 1994
Electrical
Issued 16 August 1993 Resolved
REINSTALL THE COVERS ON THE GENERATOR ELECTRICAL C0NTROL BOX AND THE BATTERY COMPARTMENT JUNCTION BOX TO COMPLY WITH 46 CFR 183.05-50(B).
Condition: Unknown
Due 30 August 1993
Resolved 7 September 1993
Engineering
Issued 16 August 1993 Resolved
REPLACE IMPROPER FUEL HOSES FROM FUEL TANK TO BOTH MAIN ENGINES AND FROM THE FUEL TANK TO THE GENERATOR AND INSTALL FLEXIBLE HOSES WHICH COMPLY WITHTHE REQUIREMENTS OF 46 CFR 182.15-40(B)(5).
Condition: Unknown
Due 30 August 1993
Resolved 7 September 1993
Construction/Loadline
Issued 16 August 1993 Resolved
REMOVE ALL OIL FROM THE GENERATOR COMPARTMENT BIGE TO COMPLY WITH THE REQUIREMENTS OF 46 CFR 176.25-50(B).
Condition: Unknown
Due 30 August 1993
Resolved 7 September 1993
Lifesaving
Issued 10 August 1992 Resolved
REPAIR SPLICE ON BUOYANT APPARATUS LIFELINE.
Condition: Unknown
Due 10 September 1992
Resolved 9 September 1992
Lifesaving
Issued 10 August 1992 Resolved
PROVIDE APPROPRIATE SIZE WEAK LINKS FOR TWO BUOYANT APPARATUS. _x001C_
Condition: Unknown
Due 10 September 1992
Resolved 9 September 1992
Construction/Loadline
Issued 10 August 1992 Resolved
PROVIDE OPERABLE BILGE PUMP IN PORT HULL.
Condition: Unknown
Due 10 September 1992
Resolved 9 September 1992
Navigation
Issued 10 August 1992 Resolved
MAKE PORT AND STARBOARD RUNNING LIGHTS OPERABLE. VESSEL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL THE DEFICIENCY IS CORRECTED.
Condition: Unknown
Due 10 September 1992
Resolved 9 September 1992
Documentation
Issued 10 August 1992 Resolved
PROVIDE MSO HONOLULU WITH A COPY OF FCC RADIO OPERATORS PERMIT.
Condition: Unknown
Due 10 September 1992
Resolved 9 September 1992
Navigation
Issued 13 August 1991 Resolved
PROVE THE PROPER OPERATION OF THE STARBOARD RUNNING LIGHT. VESSEL OPERATION IS RESTRICTED TO DAYTIME UNTIL REPAIRS ARE COMPLETE.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Deck/Cargo
Issued 13 August 1991 Resolved
PROVIDE 8-12 FEET OF SUITABLE CHAIN FOR MAIN ANCHOR LINE.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Construction/Loadline
Issued 13 August 1991 Resolved
FRESHEN UP ALL HULL MARKINGS AND ADD VESSEL NAME TO STERN.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Lifesaving
Issued 13 August 1991 Resolved
RENEW THE NYLON THROW LINE AND WATER LIGHT LINE ON THE RING BOUY.
Condition: Unknown
Due 13 August 1991
Resolved 13 August 1991
Documentation
Issued 14 August 1990 Resolved
POST ON BOARD THE VESSEL A GARBAGE DUMPING PLACARD AS REQUIRED BY 33 CFR 151.59.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Construction/Loadline
Issued 14 August 1990 Resolved
MAKE PERMANENT REPAIRS TO AND PROVE SATISFACTORY OPERATION OF THE PORT FIXED ELECTRIC POWER BILGE PUMP. VESSEL IS RESTRICTED TO THE CARRIAGE OF 49 PASSENGERS UNTIL THE ABOVE REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 15 August 1989 Resolved
REMOVE PLASTIC FUEL TANKS FROM VESSEL AND REPLACE WITH TANK OR TANKS OF METALIC CONTRUCTION EQUIPPED WITH QUICK DISCONNECT FITTINGS.
Condition: Unknown
Due 15 August 1989
Resolved 15 August 1989
Lifesaving
Issued 27 June 1988 Resolved
INSTALL NEW REFLECTIVE TAPE ON ALL PFD'S WHERE TAPE IS TORN, FADED, MILDEWED, OR MISSING. VESSEL CAN CARRY PASSENGERS DURING DAYLIGHT HOURS ONLY UNTIL TAPE HAS BEEN RENEWED.
Condition: Unknown
Due 27 June 1988
Resolved 27 June 1988
Fire Fighting
Issued 6 May 1988 Resolved
AT NEXT SCHEDULED DRYDOCK AND NO LATER THAN 30NOV88, INSTALL BILGE AND FIREMAIN SYSTEMS AS REQUIRED BY 46 CFR 181.10-1, 182.25-10 AND 182.40-5 AND AS DETAILED IN MSO LETTER DATED 28MAR88. UNTIL CORRECTED VSL MUST CARRY TWO ADDITIONAL B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Fire Fighting
Issued 16 March 1988 Resolved
INSTALL BILGE AND FIRE MAIN PIPING SYSTEMS AS REQUIRED BY 46 CFR 181.10-1, 182.25-10 AND 182.40-5 AND DETAILED IN MSO LTR OF 28 MAR 88.
Condition: Unknown
Due 16 March 1988
Resolved 16 March 1988
Unknown
Issued 19 August 1986 Resolved
PROVIDE FOLLOWING DETAILS FOR STABILITY CALCULATIONS: MAST HEIGHT; SAIL AREA; DISTANCE BETWEEN HULL CENTERLINES; AND DISPLACEMENT.
Condition: Unknown
Due 19 August 1986
Resolved 19 August 1986
Unknown
Issued 19 August 1986 Resolved
PROVIDE AND PLACE ON BOARD VESSEL ONE HAND PORTABLE FIRE PUMP IN ACCORDANCE WITH 46 CFR 181.10-5.
Condition: Unknown
Due 19 August 1986
Resolved 19 August 1986
Accommodation/Occupational Safety
Issued 9 April 1985 Resolved
INSTALL 36 INCH RAILS IN THE FORWARD AREA OF VESSERL. SUBMIT DETAILS OF INSTALLATION TO [name withheld].
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Accommodation/Occupational Safety
Issued 9 April 1985 Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN FORWARD BOARDING LADDER.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Accommodation/Occupational Safety
Issued 9 April 1985 Resolved
INSTALL LOCKING DEVICE FOR OVERBOARD DISCHARGE VALVE. INSTALL VENT LINES AND PROPERLY SECURE ELECTRICAL CONDUCTORS FOR TYPE III MSDS.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Accommodation/Occupational Safety
Issued 9 April 1985 Resolved
SECURE PORT AND STARBOARD BILGE PUMP SUCTION LINES.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Accommodation/Occupational Safety
Issued 9 April 1985 Resolved
INSTALL RELIEF VALVE PIPING TO BILGE AND PROPERLY SECURE FRESH WATER PIPING FOR HOT WATER HEATER.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Electrical
Issued 9 April 1985 Resolved
RENEW DELAMINATED SECTION OF SERVICE GENERATOR EXHAUST NONMETALLIC FLEX. PIPING.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985
Construction/Loadline
Issued 9 April 1985 Resolved
RENEW DECAYED AREA ON SUPERSTRUCTURE DECK IN WAY OF PORT SKYLIGHT AS ORIGINAL.
Condition: Unknown
Due 9 April 1985
Resolved 9 April 1985

Casualty record · 1

1 June 2022Routine · role: Involved in a Marine Casualty · activity 7465807
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.