Records from 2005 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 25
12 May 2026
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8383411
5 May 2025
COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8113887
22 October 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8036520
20 September 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7814616
8 December 2022
Annual Inspection · Administrative Inspection · Hull Examination · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7607645
9 May 2022
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7454113
1 March 2022
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7434767
19 January 2022
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7382679
27 September 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7339158
4 June 2020
COI Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6968287
28 May 2020
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6962532
28 October 2019
MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6860529
11 April 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6667712
17 January 2019
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6612224
16 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6598006
16 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6619903
7 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599712
7 November 2018
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6599726
25 October 2018
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6570264
13 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6539905
29 September 2017
MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6277780
26 January 2017
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6081919
17 October 2016
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6028833
22 June 2016
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5925139
24 February 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5820982
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2023
Resolved
MDE exhaust lagging loose & not properly secured.
Must be corrected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 15 June 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 12 June 2023
Resolved
V-drive room emergency exit guard for rotating machinery is missing, must be replaced.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 June 2023
Resolved 12 June 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 12 June 2023
Resolved
V-drive compartment has about 1 inch of entrained water, must be removed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2023
Resolved 12 June 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2023
Resolved
Pump control junction box covers are missing (located in front of MDEs). Must be re-installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 14 June 2023
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2023
Resolved
Maindeck child PFD stowage msut be made so the PFD's are readily accessible.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2023
Resolved 12 June 2023
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 27 September 2021
Resolved
Main deck cracked at forward bit, must be permanently repaired.
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 19 April 2022
Resolution: Bit replaced, all sat.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 27 September 2021
Resolved
10-12 seats are cracked and require replacement.
Action required: 705 - Other - as specified
Due 1 May 2022
Resolved 19 April 2022
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 September 2021
Resolved
engineroom access cover gasket is deteriorated, must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 October 2021
Resolved 15 October 2021
Resolution: replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2020
Resolved
Masthead light is extinguished. Make Masthead light operable. Vessel will not operate during low visibility or darkness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 11 June 2020
Resolution: Replaced bulb.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 4 June 2020
Resolved
Watertight door indicator light in pilothouse is inoperable. Make indicator light function correctly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 11 June 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2020
Resolved
Discharge hose on electric bilge pump in the engine room is detached from the overboard valve on the port bulkhead.
Reattach hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 11 June 2020
Resolution: Reattached
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 28 October 2019
Resolved
Guard must installed in V-drive compartment forward the watertight door at egress route to prevent accidental falls into V-drive shafts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 4 June 2020
Resolution: Corrected. Added guards.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 28 October 2019
Resolved
Stbd MDE outboard turbo lagging loose, must be securely fastened.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 May 2020
Resolved 4 June 2020
Resolution: Corrected, Lagging tightend up.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 October 2019
Resolved
Masthead, stern & anchor lights are inoperative. Repair and make ready for inspection. Vessel not allowed to operate in low visibility or night time conditions until corrected.
Action required: 705 - Other - as specified
Due 28 October 2019
Resolved 4 June 2020
Resolution: Corected
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 October 2018
Resolved
Lifejacket stowage bins need to be relabled with proper quantity.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2018
Resolved 17 January 2019
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 October 2018
Resolved
Replace lifelines on ring buoy at wheelhouse due to deterioration.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2018
Resolved 17 January 2019
Resolution: replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 October 2018
Resolved
Remove and replace expired medication in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 November 2018
Resolved 17 January 2019
Resolution: replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 October 2018
Resolved
Remove insulation hooks in compartments where insulation is no longer being utilized prior to next operating season.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 June 2019
Resolved 11 April 2019
Resolution: re-installed insulation.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 25 October 2018
Resolved
Repair weld fractures IWO the forward access hatch prior to next operating season.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 June 2019
Resolved 11 April 2019
Resolution: repaired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018
Resolved
The vessel is currently broadcasting (1) Improper IMO Number, (2) Improper Call Sign, ()
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 October 2018
Resolved 1 May 2019
Resolution: Received notification of AIS broadcasting correction from vessel owner. Verified no errors in VIVS.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 October 2017
Resolved
Properly mount E/R PFE
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 15 November 2017
Resolution: mounted.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 October 2017
Resolved
replace worn retro-reflective tape on 2 RLBs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 12 October 2017
Resolution: replaced.
Fire Fighting › Fire Hoses › Connections
Issued 10 October 2017
Resolved
relocate spanner wrenches to each fire station - make readily available
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 15 November 2017
Resolution: completed.
Fire Fighting › Combustible Materials › Insulation
Issued 17 October 2016
Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 19 April 2017
Resolution: corrected during hull exam.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 October 2016
Resolved
Install guards and signage to prevent entanglement in rotating driveshafts at both main engines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 19 April 2017
Resolution: completed during hull exam.
Engineering › Bilge Water Management System › Strainer
Issued 17 October 2016
Resolved
Raise bilge suction strainer away from hull plating in lazarette, to provide adequate suction clearance.
Condition: Improper/Lack of Maintenance
Due 19 November 2016
Resolved 19 April 2017
Resolution: corrected during hull exam
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2016
Resolved
man-overboard recovery davit malfunctioned, jammed during drill, corrected during inspection.
Condition: Design Flaw
Due 22 June 2016
Resolved 22 June 2016