Inspection history · 17
23 July 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8185726
7 July 2025
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8178567
10 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8109047
1 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7757746
19 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7671679
19 May 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7460592
21 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7435200
24 August 2021
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7284367
21 September 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7284349
29 April 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6945874
19 September 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6815927
31 July 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6496279
9 May 2018
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6409797
14 August 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6240124
24 June 2016
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5915314
23 March 2016
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5838725
24 February 2016
Plan Review "T" Boat
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5821340
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 July 2025
Resolved
"Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date." Vessel did not complete annual inspection within 3 months of anniversary date of AUG 30; last annual inspection was 01 AUG 23. Complete a US Coast Guard inspection prior to the carriage of passengers.
46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2025
Resolution: Cleared per COI activity
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2023
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment including the following...For fixed gas fire extinguishing systems, the inspections and tests required by Table 176.810(b), in addition to 46 CFR 147.60 and 147.65. At the time of inspection, vessel was unable to test pre engineered fixed fire suppression system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 August 2023
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a). At the time of inspection, vessel could not demonstrate operation of bilge system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2023
Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. At the time of inspection, the vessel was not found in compliance with the above regulation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2023
Resolved
Except as otherwise provided in this section, all vessels shall carry pyrotechnic distress signals as follows: 6 red flare distress signals and 6 hand orange smoke distress signals or, 12 hand combination flare and smoke distress signals. Vessel's pyrotechnics were expired at the time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 August 2023
Resolved
Vessel's shall be equipped with a suitable number of portable battery lights. At the time of inspection, the vessel did not have working portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2023
Resolved
Life preserves shall be distributed through the upper part of the vessel in protected places convenient to the persons on board. Vessel's life perseveres were not stored in an accessible location to passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 August 2023
Resolved
All life preservers shall be marked with the vessel's name. A number of life-jackets on board the vessel were inaccurately labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2023
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 August 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2020
Resolved
Vessel’s fwd area of bench seat was broken IWO it’s attachment to the forward bulkhd, this needs to repaired to like new condition and a written repair proposal submitted for approval to the Coast Guard Marine Inspector prior to repair being done.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2021
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 30 April 2020
Resolved
Engine room hatch gasket must be replaced to be water tight as designed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2021
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 April 2020
Resolved
The deck support stanchion (2x4) on the port and stbd side IWO engine room is rotten and needs to be replaced to like new condition. A written repair proposal listing material to be used and drawing of the area must be submitted for approval prior to repairs being started.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2021
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 April 2020
Resolved
Engine room compartment IWO first stringer/engine bed outboard sides port & stbd has some material that is built up making it flush with the stringer, this material is coming loose, must investigate this area and possibly remove and repair to like new condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 31 July 2018
Resolved
A vessel must have a visual and audible alarm at the operating station to indicate high water level in unmanned spaces. The bilge alarm at the control station must be replaced. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 7 August 2018
Resolved 6 August 2018
Resolution: Bilge alarm was replaced and function checked.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 July 2018
Resolved
The vessel may be inspected in accordance with standards
acceptable to the cognizant OCMI as good marine
practices. Covers must be obtained for the engine space ventilation. 46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 6 August 2018
Resolution: Ventilation covers were obtained and function tested.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 31 July 2018
Resolved
The vessel may be inspected in accordance with standards
acceptable to the cognizant OCMI as good marine
practices. The gasket on the hatch for the engine space must be replaced. 46 CFR 176.800(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2018
Resolved 6 August 2018
Resolution: Gasket was replaced resulting in a good seal.
Construction/Loadline › Hull › Hull Plating
Issued 23 March 2016
Resolved
SH01: Provide repair proposal for damage to bow fiberglass noted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 10 May 2016
Resolution: Approved repair proposal was submitted to [name withheld].
Construction/Loadline › Structures › End Bulkhead
Issued 23 March 2016
Resolved
SH02: Re-pack stuffing tube in forward compartment for cable run.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 7 June 2016
Resolution: Cable stuffing tube to was repacked.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 23 March 2016
Resolved
SH03: Repair area around STBD vent in forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2016
Resolved 7 June 2016
Resolution: STBD vent area was reapired.