MAURY USCG vessel records
← All vessels

WINDWALKER II

Built
1979
Last inspected
25 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 February 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5572
Flag
UNITED STATES
Maury page id
psix-52243

Documentation record

Registered dimensions (L × B × D)39.7 ft × 14.8 ft × 7.1 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEWEY G SALTER · SWANSBORO NORTH CAROLINA, UNITED STATES · built 1979
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDOUGLASVILLE, GA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 27 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

25 February 2026 Vessel Attendance · COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8304810
23 January 2026 Vessel Attendance · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8300551
28 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8123471
5 March 2025 Deficiency Check · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8089152
20 February 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8082275
8 April 2024 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7891943
26 February 2024 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7869390
20 July 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7747667
30 March 2023 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7659988
27 March 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7657911
16 February 2023 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7643695
6 February 2023 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7632848
25 May 2022 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7459549
4 May 2022 Construction Oversight
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7444097
2 March 2021 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7145522
16 February 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7141143
10 March 2020 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6921705
17 July 2019 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6752839
26 March 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6658683
7 March 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6640048
24 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570743
27 March 2018 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6375981
6 February 2018 Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6352300
3 August 2017 Type not recorded
No type recorded · Station Destin · USCG Heartland District (CGD-H) · Activity 6230039
9 May 2017 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6139092
23 February 2017 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6089056
10 March 2016 Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5815271

Deficiency record · 27

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2026 Resolved
Vessel is missing 01 ventilation closure device (vent plug). Vessel is fitted with 04 ventilation louvers and only has 03 closure devices on hand.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2026
Resolved 9 March 2026
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 25 February 2026 Resolved
Vessel must have a means to recover person from the water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2026
Resolved 9 March 2026
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 25 February 2026 Resolved
Vessel O/O must be enrolled with consortium as a Marine Employer and make available for inspection: - Vessel Drug and Alcohol Policy - Employee Assistance Program - Supervisor Training
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2026
Resolved 9 March 2026
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2024 Resolved
Automatic bilge pump float switch was loose and inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2024
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2024 Resolved
Vessel's stern light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 April 2024
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 March 2023 Resolved
Inspect watertight closures. Through hull valve was loose in wood hull and held in place with caulk.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 April 2023
Resolution: Through hull fitting made tight.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2023 Resolved
Inspect fasteners in accordance with 46 CFR 176.30-1. Identified rotted frame on port side of engine compartment, replace frame from shine up to deck, caulk and through-bolt with carriage bolts at hull frame.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2023
Resolution: New frame added aft of affected frame.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 6 February 2023 Resolved
Inspect fasteners in accordance with 46 CFR 176.30-1. Identified wasted carriage bolts from engine room forward where floors are attached to the hull frames up to chain locker. Owner to identify and replace wasted bolts.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2023
Resolution: Fasteners renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 February 2023 Resolved
Inspect fasteners in accordance with 46 CFR 176.30-1. Identified rotted hull plank on fwd/stbd side approximately 37 feet forward of stern. Owner to identify extent of rot and repair in-kind.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 March 2023
Resolution: Repaired.
Lifesaving › Lifefloat › Serviceable
Issued 27 March 2018 Resolved
Replace lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 March 2018
Resolved 7 April 2018
Resolution: new life float provided.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 March 2018 Resolved
Secure wires in vertical wire way in cabin (at least every 24")
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 7 April 2018
Resolution: corrected
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 27 March 2018 Resolved
Gouge and reweld crack on ladder to pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2018
Resolved 7 April 2018
Resolution: corrected
Construction/Loadline › Hull › Collision Strap
Issued 9 May 2017 Resolved
Collision bulkhead bilge alarm was inoperable.
Condition: Improper/Lack of Maintenance
Due 24 May 2017
Resolved 24 May 2017
Communications › Radio Communications › EPIRB
Issued 9 May 2017 Resolved
EPIRB was not registered
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 9 May 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Resolution: radio station license was renewed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2017 Resolved
FIRST AID KIT was out of date.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Resolution: first aid kit was replaced.
Construction/Loadline › Penetrations › Gasket
Issued 9 May 2017 Resolved
Rudder post was leaking excessively
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Resolution: rudder was repacked.
Lifesaving › Lifefloat › Lifeline
Issued 9 May 2017 Resolved
Life float needed line replaced.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Resolution: life line was replaced
Construction/Loadline › Structures › Machinery Space Opening
Issued 9 May 2017 Resolved
wood vessel had small leaks
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2017
Resolved 24 May 2017
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2016 Resolved
STBD side Eng Room Butt Block Leaking.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 24 March 2016
Resolution: corrected
Engineering › Steering Gear System › Rudder Bearing
Issued 10 March 2016 Resolved
Re-new Steering Post Packing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2016
Resolved 24 March 2016
Resolution: corrected
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 March 2016 Resolved
Repair fwd hatch cover
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected
Lifesaving › Lifefloat › Lifeline
Issued 10 March 2016 Resolved
Renew lifefloat light line
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected
Lifesaving › Lifefloat › Lifeline
Issued 10 March 2016 Resolved
Renew retro tape on lifefloat
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected
Fire Fighting › Fire Bucket › Lanyard
Issued 10 March 2016 Resolved
One forebucket is missing its lanyard
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 March 2016 Resolved
Mount bilge pump in steering box
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected
Lifesaving › Lifefloat › Painter
Issued 10 March 2016 Resolved
Renew painter line
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 March 2016
Resolved 24 March 2016
Resolution: corrected

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.