MAURY USCG vessel records
← All vessels

MOBRO 5000

Built
1976
Last inspected
24 June 2004
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 24 June 2004
…with no type recorded8
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 13 calendar years (1981–2004)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-52257

Documentation record

Tonnage as PSIX records it2094 - Convention (Subpart B), Gross Ton
628 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 27 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIMBERLY POLING Towing Vessel · MISLE 434725 · 18 May 2004 · activity 2071372

Inspection history · 27

24 June 2004 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2108968
21 June 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2105788
26 May 2004 COI Inspection · MARPOL Annex I Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2084610
18 May 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2071372
28 June 1996 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 934713
13 January 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172444
14 December 1994 COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1150752
10 June 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 439533
2 June 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 41396
1 June 1993 COI Inspection · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 840203
28 August 1992 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1266658
11 August 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250876
31 March 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 96054
31 March 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664631
6 February 1992 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 949444
3 October 1991 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 936882
16 July 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 936015
28 August 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 917731
22 August 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 907564
13 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 914708
25 September 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1208411
15 September 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347013
31 July 1989 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 894084
27 January 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1332176
16 December 1987 Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1328040
29 January 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272056
14 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970551

Deficiency record · 22

Deck/Cargo › Cargo Stowage
Issued 26 May 2004 Resolved
Vessel did not have a COI at the time, having Hazzard cargo on board
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2004
Resolved 28 May 2004
Resolution: Vessel rcvd COI
Construction/Loadline › Structures › Air Pipe
Issued 26 May 2004 No resolution recorded
Stbd Side Rub rail bursted open, wasted due to water intrustion
Condition: Damaged By Earlier Event
Due 27 June 2004 — due date passed with no resolution recorded
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 May 2004 Resolved
Vessel need to paint draft marks and hailing port on stern and bow.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2004
Resolved 28 May 2004
Resolution: Attended vessel found Sat
Construction/Loadline
Issued 16 July 1991 Resolved
Remove helo pad on barge. No helo landings allowed. Pad to be remove by 31aug91_x001C_
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Unknown
Issued 22 August 1990 Resolved
REMOVE ALL PAINT CANS, OIL BUCKETS, OXYGEN TANKS & EXTRA FIRE EXTINGUISHER BRACKETS FROM VESSEL (MACH ROOM).
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990 Resolved
INSTALL REMOTE FUEL SHUTOFF FOR MACH RM. REMOTE FUEL SHUTOFF SHALL BE OUT- SIDE MACHINERY RM(ON DECK) AND ATTACHED TO VALVE CLOSEST TO TANK LEADING TOGENERATOR AND LABEL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990 Resolved
CAP OR PLUG FUEL TANK DRAIN VALVE AT BOTTOM MACH SPACE FUEL TANK.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990 Resolved
OVERSPEED STARBOARD GENERATOR TO SATISFACTION OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990 Resolved
REMOVE/REPAIR AIR COMPRESSOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990 Resolved
INSTALL HEAT SHIELDS ON BOTH GENERATOR RACOR FUEL FILTERS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990 Resolved
REPAIR FUEL FILTER FUEL LEAK AT PORT GENERATOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 22 August 1990 Resolved
MOUNT PLACARD ADJACENT TO BALLAST PUMP
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990 Resolved
PROVIDE BLANKS FOR OPENINGS IN DISTRIBUTION PANEL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990 Resolved
PROVIDE COVER FOR LIGHTS SWITCH ADJACENT TO MACHINERY ROOM DOOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990 Resolved
PROVIDE GLOBE FOR LIGHT IN MACHINERY ROOM ADJACENT TO DOOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990 Resolved
INSTALL PERMANENT BALLAST TANK VENT CLOSURES.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990 Resolved
PROVIDE MARINE TYPE FIRE EXTINGUISHER BRACKETS FOR ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990 Resolved
REPLACE MISSING DOG (3) ON MACHINERY ROOM HATCH COVER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 31 July 1989 Resolved
SERVICE PORTABLE FIRE EXTINGUISHER PRIOR TO PUTTING VESSEL INTO SERVICE3.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989 Resolved
(CONT) AS A MANNED SEAGOING BARGE AND PROVIDE EVIDENCE THAT THE PVHO'S MEETTHE REQUIREMENTS OF SUBPART B OF 46 CFR PART 197.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989 Resolved
REMOVE MODULAR LIVING QUARTERS, HELO PAD, AND PRESSURE VESSELS FOR HUMAN OCCUPANCY (PVHO'S) PRIOR TO PUTTING BARGE INTO SERVICE BUT NOT LATER THAN 19AUG89, TO THE SATISFACTION OF THE LOCAL OCMI OR SUBMIT APPLICATION FOR INSPECTION AND PLANS AS REQUIRED BY 46CFR91.20 FOR VESSEL TO BE RECERTIFIED
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 16 December 1987 Resolved
PROVE TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR BOTH GENERATORSOVERSPEED TRIPS AND SHUTDOWN ON LOSS OF LUBRICATING PRESSURE.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.