This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it2094 - Convention (Subpart B), Gross Ton 628 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 27 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; 1 other vessel inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
Vessel did not have a COI at the time, having Hazzard cargo on board
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 May 2004
Resolved 28 May 2004
Resolution: Vessel rcvd COI
Construction/Loadline › Structures › Air Pipe
Issued 26 May 2004No resolution recorded
Stbd Side Rub rail bursted open, wasted due to water intrustion
Condition: Damaged By Earlier Event
Due 27 June 2004 — due date passed with no resolution recorded
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 26 May 2004Resolved
Vessel need to paint draft marks and hailing port on stern and bow.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 May 2004
Resolved 28 May 2004
Resolution: Attended vessel found Sat
Construction/Loadline
Issued 16 July 1991Resolved
Remove helo pad on barge. No helo landings allowed. Pad to be remove by 31aug91_x001C_
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Unknown
Issued 22 August 1990Resolved
REMOVE ALL PAINT CANS, OIL BUCKETS, OXYGEN TANKS & EXTRA FIRE EXTINGUISHER BRACKETS FROM VESSEL (MACH ROOM).
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990Resolved
INSTALL REMOTE FUEL SHUTOFF FOR MACH RM. REMOTE FUEL SHUTOFF SHALL BE OUT- SIDE MACHINERY RM(ON DECK) AND ATTACHED TO VALVE CLOSEST TO TANK LEADING TOGENERATOR AND LABEL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990Resolved
CAP OR PLUG FUEL TANK DRAIN VALVE AT BOTTOM MACH SPACE FUEL TANK.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990Resolved
OVERSPEED STARBOARD GENERATOR TO SATISFACTION OF ATTENDING MARINE INSPECTOR
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990Resolved
REMOVE/REPAIR AIR COMPRESSOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990Resolved
INSTALL HEAT SHIELDS ON BOTH GENERATOR RACOR FUEL FILTERS.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Engineering
Issued 22 August 1990Resolved
REPAIR FUEL FILTER FUEL LEAK AT PORT GENERATOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Documentation
Issued 22 August 1990Resolved
MOUNT PLACARD ADJACENT TO BALLAST PUMP
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990Resolved
PROVIDE BLANKS FOR OPENINGS IN DISTRIBUTION PANEL.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990Resolved
PROVIDE COVER FOR LIGHTS SWITCH ADJACENT TO MACHINERY ROOM DOOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1990Resolved
PROVIDE GLOBE FOR LIGHT IN MACHINERY ROOM ADJACENT TO DOOR.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990Resolved
INSTALL PERMANENT BALLAST TANK VENT CLOSURES.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 22 August 1990Resolved
PROVIDE MARINE TYPE FIRE EXTINGUISHER BRACKETS FOR ALL FIRE EXTINGUISHERS
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990Resolved
REPLACE MISSING DOG (3) ON MACHINERY ROOM HATCH COVER.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Fire Fighting
Issued 31 July 1989Resolved
SERVICE PORTABLE FIRE EXTINGUISHER PRIOR TO PUTTING VESSEL INTO SERVICE3.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989Resolved
(CONT) AS A MANNED SEAGOING BARGE AND PROVIDE EVIDENCE THAT THE PVHO'S MEETTHE REQUIREMENTS OF SUBPART B OF 46 CFR PART 197.
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Construction/Loadline
Issued 31 July 1989Resolved
REMOVE MODULAR LIVING QUARTERS, HELO PAD, AND PRESSURE VESSELS FOR HUMAN OCCUPANCY (PVHO'S) PRIOR TO PUTTING BARGE INTO SERVICE BUT NOT LATER THAN 19AUG89, TO THE SATISFACTION OF THE LOCAL OCMI OR SUBMIT APPLICATION FOR INSPECTION AND PLANS AS REQUIRED BY 46CFR91.20 FOR VESSEL TO BE RECERTIFIED
Condition: Unknown
Due 31 July 1989
Resolved 31 July 1989
Electrical
Issued 16 December 1987Resolved
PROVE TO THE SATISFACTION OF A COAST GUARD MARINE INSPECTOR BOTH GENERATORSOVERSPEED TRIPS AND SHUTDOWN ON LOSS OF LUBRICATING PRESSURE.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.