MAURY USCG vessel records Sign in
← All vessels

U-RASCAL

U-RASCAL is a 1977 passenger vessel (inspected). The Coast Guard has recorded 62 inspections since 1985, most recently in June 2026, along with 101 deficiencies — 3 with no resolution recorded —.

Records from 1985 to 2026. Most recent: inspection, 23 June 2026.

Built
1977
Last inspected
23 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAS9780
Flag
UNITED STATES
367135630
Maury page id
psix-52260

Inspections, by type

…with no type recorded3
Years with a record 37 calendar years (1985–2026)
The 62 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.9 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 28 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE & LAKE UNION · SEATTLE WA · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portKODIAK, AK
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 26 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAS9780MMSI 367135630 · active · compulsorily equipped · granted 27 August 2026, expires 15 November 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 62

23 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8412224
9 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8198843
9 May 2025 Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8131798
7 May 2025 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 8130608
1 April 2024 In-Service Inspection · Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7888286
28 April 2023 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7677603
13 October 2022 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7573605
7 April 2022 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7426596
24 March 2022 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7418178
3 February 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7390620
4 July 2021 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7260169
27 November 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7106564
7 November 2019 Damage Survey · Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6858133
8 May 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6681429
10 December 2018 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6595454
8 November 2017 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6302615
25 April 2017 Drydock Exam
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6132703
15 November 2016 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 6041893
9 November 2015 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5769180
20 August 2015 DAPI Audit
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 5742710
18 May 2012 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 4314452
24 June 2008 Annual Inspection · Uninspected Passenger Vessel · DAPI Audit
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3246956
15 May 2007 Administrative Inspection · Internal Structural Exam · MARPOL Annex V Examination · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2931106
27 October 2006 Deficiency Check
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2811008
11 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2775868
7 June 2006 Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2673132
22 March 2005 Liferaft Servicing · Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2317090
6 April 2004 Annual Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 2038781
15 May 2003 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1794138
26 June 2002 COI Inspection
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 1637377
7 December 2001 Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1366693
14 September 2001 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1395807
6 June 2001 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1382290
13 October 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 822979
22 September 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1054512
26 July 2000 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1052334
13 June 2000 Deficiency Check · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1440285
19 October 1999 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1397227
15 June 1999 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1375815
11 June 1998 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1375814
10 November 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785434
30 May 1997 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 794346
9 July 1996 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1371485
6 July 1995 Deficiency Check · Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 882086
12 May 1995 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 882089
25 May 1994 COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 861125
1 July 1993 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1379843
7 March 1993 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 837480
14 September 1992 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 946535
10 June 1992 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1269464
3 May 1991 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1211935
4 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1296822
26 August 1989 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1350396
28 April 1989 Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 973912
13 April 1989 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1210562
28 March 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1345405
7 March 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 888599
14 June 1988 Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1205884
27 May 1988 Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1045395
19 June 1987 Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1029948
9 May 1986 Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1007003
6 June 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 982381

Deficiency record · 101

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 23 June 2026 No resolution recorded
Each Ring life buoy on a vessel must be approved in accordance with 160.050 and meet requirements for retro-reflective material. the ring life buoys reflective material is heavily faded and weathered. Replace retro-reflective material on ring life buoy. Vessel is limited to day light hours only until replaced.
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 June 2026 No resolution recorded
A vessel must carry one floating waterlight, unless limited to daylight hours. Vessels waterlight battery was expired. Replace battery with new manufactured approved battery. Vessel is limited to daylight hours only until replaced.
Action required: 705 - Other - as specified
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 23 June 2026 No resolution recorded
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct inspections of the hull, decks, and bulkheads. The aft portion of the superstructure bonded to the air intake pipping vest was found cracked. Ruff out the crack and conduct repair.
Action required: 50 - Rectify deficiencies w/in 30 days
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2025 Resolved
Vessel shall be structurally adequate for it intended service. The port-side main deck forward of the operating station was found in need of repair and accumulating water. Vessel authorized to operate 2025 season. Vessel not authorized to operate 2026 season until repairs are made. Provide repair proposal for intended repairs for the review of a USCG marine inspector.
Action required: 705 - Other - as specified
Resolved 12 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 May 2025 Resolved
Vessel shall be structurally adequate for it intended route & service. Found two Sister boards in the Center Void compartment collecting water due to Item (NO. 1) Crop and Renew defective supports.
Action required: 705 - Other - as specified
Resolved 12 December 2025
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 May 2025 Resolved
The vessel shall be made available for Dry Dock Examination (DDX) and Internal Structural Examination (ISE) once every year until port repairs have been made. Vessel owner did not schedule dry dock prior to 31MAR25. Make vessel available and obtain credit DDX and ISE from an attending USCG marine inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2025
Resolution: Conducted required drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 June 2024 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in a space with a through hull fitting below the deepest load waterline. Vessel's lazarette high water alarm not functioning, and the center compartment high water alarm has no visual. 46 CFR 182.530(a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2024
Resolution: Vessel's highwater alarms are functioning.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 June 2024 Resolved
A vessel of 12 meters or more in length shall be provided with a whistle. Vessel's whistle is not functioning and there is no back up on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2024
Resolution: ships whistle works.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 June 2024 Resolved
At each initial and subsequent inspection for certification the marine inspector may require that a man overboard drill be held. Vessel was unable to complete man overboard drill. 46 CFR 176.808(G)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 June 2024
Resolution: Vessel completed man overboard drill.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 June 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information specific to the vessel. Vessel does not have placard at radio operating station. 46 CFR 184.506
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2024
Resolved 11 June 2024
Resolution: Vessel has emergency radio broadcast instructions.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 June 2024 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Vessel does not have life jacket donning placards. 46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2024
Resolved 11 June 2024
Resolution: Vessel has lifejacket placard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 June 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible. Vessel's chart is out of date. 46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2024
Resolved 11 June 2024
Resolution: Vessel's chart is updated
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 June 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date publications. Vessels U.S. Coast Pilot and light list are out of date. 46 CFR 184.420(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 July 2024
Resolved 11 June 2024
Resolution: Vessels U.S. Coast Pilot and light list are up to date
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2022 Resolved
An adult life jacket must be provided for each person carried on board the vessel. Discovered 4 lifejackets were unservicable. Passenger count reduced to 13 until lifejackets are replaced. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 October 2022
Resolution: Master purchased 2 new lifejackets.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 13 October 2022 Resolved
If a garden hose is used it shall be of good commerical grade. Vessel's fire hose was a garden hose that was not of good commerical grade, and the nozzle was plastic. 46 CFR 181.15-10(e) (Old T)
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 27 October 2022
Resolved 13 October 2022
Resolution: Master purchased commercial grade garden hose.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 October 2022 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or equivalent. Vessel's first aid kit has multiple expired medication.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2022
Resolved 13 October 2022
Resolution: Master purchased new first-aid kit approved under 160.041
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 June 2022 Resolved
Found delam FRP in port side of the transom. Satisfactory repairs made up to the main deck. Make satisfactory repairs IWO the main deck and above prior to next required drydock (31MAR23).
Action required: 705 - Other - as specified
Due 31 March 2023
Resolved 7 April 2024
Resolution: Satsifactory repairs made.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 February 2022 Resolved
Battery expired
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 February 2022
Resolved 7 February 2022
Resolution: renewed
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 3 February 2022 Resolved
Safety radio expired
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 7 April 2022
Resolution: Renewed Ship radio safety cert
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 February 2022 Resolved
CG light list expired
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 7 February 2022
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 3 February 2022 Resolved
U.S Coast Pilot outdated
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2022
Resolved 7 February 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 February 2022 Resolved
Cover missing on light switch in wheel house
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 February 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 3 February 2022 Resolved
406 EPIRP not registered with NOAA
Action required: 705 - Other - as specified
Resolved 7 April 2022
Resolution: Renewed NOAA 406 EPIRB registration
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 7 November 2019 Resolved
U-RASCAL suffered damage due to a fire onboard the SILVER BULLET. Replace vessel's liferaft and make permanent repairs to the satisfaction of a Coast Guard Marine Inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 March 2020
Resolution: Vessel completed repairs to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 December 2018 Resolved
Life ring labeling was found to be peeling off the life ring and the 60' line wa not buoyant 5/16" line. Provide new lettering for vessel's name on the lifering and required 60' line.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2019
Resolved 8 May 2019
Resolution: Life ring relabeled and required 60' line properly attached.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 20 August 2015 Resolved
Company representative did not have clear arrangements for post casualty testing outlined.
Due 20 September 2015
Resolved 26 August 2015
Resolution: Company representative provided outlined arrangements for post-casualty testing.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 20 August 2015 Resolved
Company representative did not have clearly outlined arrangments for reasonable cause testing.
Due 20 September 2015
Resolved 26 August 2015
Resolution: Company representative provided outlined procedures for reasonable cause testing.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 20 August 2015 Resolved
Company representative did not have proof of 1 hour EAP training for supervisors.
Due 20 September 2015
Resolved 26 August 2015
Resolution: Company representative provided documentation of intent to conduct required training.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 May 2012 Resolved
Conduct and log monthly EPIRB testing as per 46 CFR 185.728.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 18 May 2012
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2012 Resolved
Provide chart corrections IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 18 June 2012
Engineering › Bilge Water Management System › Valve
Issued 18 May 2012 Resolved
Provide non-return valve for midship electrical submersible pump IAW 46 CFR 182.520(e)(7).
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 4 October 2012
Engineering › Bilge Water Management System › Valve
Issued 18 May 2012 Resolved
Provide non-return valve for engine room electrical submersible pump IAW 46 CFR 182.520(e)(7).
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 4 October 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 May 2012 Resolved
Blank off/remove old bilge high level alarm labels on the bridge.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 4 October 2012
Stability › Watertight Integrity › General
Issued 18 May 2012 Resolved
Make midship bulkhead watertight in way of port battery.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 4 October 2012
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 May 2012 Resolved
Provide employee assistance information to crew IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 18 June 2012
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 May 2012 Resolved
Conduct supervisory and general crew member drug awareness training IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 4 October 2012
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 18 May 2012 Resolved
Post drug and alcohol hotline numbers in a common space IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 18 June 2012
Resolved 18 June 2012
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 September 2006 Resolved
Properly mark escape route in fwd compartment and properly mark the escape hatch on the weather deck.
Due 11 October 2006
Resolved 27 October 2006
Resolution: New placards made
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 11 September 2006 Resolved
Provide non-combustible metal trash receptacle with lid.
Due 11 October 2006
Resolved 27 October 2006
Resolution: Metal trash can with lid provided
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 11 September 2006 Resolved
Provide updated coast pilot and currents table.
Due 11 October 2006
Resolved 27 October 2006
Resolution: new pubs provided
Deck/Cargo › Mooring/Anchoring › Winch
Issued 11 September 2006 Resolved
Properly repair leaks in hydraulic anchor windlass lines.
Due 11 October 2006
Resolved 27 October 2006
Resolution: Leak repaired
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 September 2006 Resolved
Provide covers for electrical boxes in fwd cabin and outrigger junction boxes.
Due 11 October 2006
Resolved 27 October 2006
Resolution: Cover provided
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 11 September 2006 Resolved
Properly repair leaks in fuel system piping on both fuel tanks.
Due 11 October 2006
Resolved 27 October 2006
Resolution: Fuel leak repaired
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 September 2006 Resolved
Properly mark the location of the First Aid Kit and the flares so that it is visible to passengers.
Due 11 October 2006
Resolved 27 October 2006
Resolution: Location marked
Construction/Loadline › Structures › Transverse Bulkhead
Issued 11 September 2006 Resolved
Provide screw type valve for thru-bulkhead penetration aft of the collision bulkhead.
Due 11 October 2006
Resolved 27 October 2006
Resolution: New valve installed
Communications › Audible Communications › Horn/Whistle
Issued 11 September 2006 Resolved
Provide adequate, fixed sound producing device.
Due 11 October 2006
Resolved 27 October 2006
Resolution: New sound producing device installed
Engineering › Steering Gear System › Rudder Bearing
Issued 22 March 2005 Resolved
While underway inspector noted excessive water leaking from port rudder shaft packing. Owner confirmed that the lazarette space needed to be dewater more then normal. Owner will install new packing.
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 11 September 2006
Resolution: New packing installed
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 22 March 2005 Resolved
Servicing on extinguishers is due by the end of May.
Due 31 May 2005
Resolved 11 September 2006
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 6 April 2004 Resolved
New engine installation required operator to re-establish engine shut down feature. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2004
Fire Fighting › Ventilation Systems
Issued 6 April 2004 Resolved
Provide vent closures for machinery space in accordance with 46 CFR 182.465 (h) LEGACY COMPONENT DESC: Ducts
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 April 2004 Resolved
Renew expired items in first aid kit.
Action required: 705 - Other - as specified
Resolved 19 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Size
Issued 6 April 2004 Resolved
3 child type 1 life jackets were very moldy and no longer orange in color. Provide 3 child size life jackets prior to carrying children on board who are under 90lbs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2004
Resolved 19 June 2004
Construction/Loadline › Structures
Issued 6 April 2004 Resolved
New engine installation resulted in new holes drilled in the forward and after engineroom bulkheads. Make all engineroom bulkheads watertight and capable of withstanding waterpressure in the event of flooding in adjacent compartments in accordance with 46 CFR 179.320 (c) LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2004
Resolved 21 May 2004
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 April 2004 Resolved
Mount ring buoy light
Action required: 705 - Other - as specified
Due 19 June 2004
Resolved 19 June 2004
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 15 May 2003 Resolved
Three deck rail stanchions on the starboard side had fractures in the base plate
Condition: Unknown
Due 25 June 2003
Resolved 11 September 2006
Engineering › Fuel Oil Service System
Issued 26 June 2002 Resolved
Newly installed fuel piping was leaking in way of 'T' connection in engineroom ceiling, leaking fuel was soaking into wooden deck beams LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Resolution: Owner tightened fitting
Operations/Management › Drug and Alcohol Testing
Issued 26 June 2002 Resolved
Newly hired deckhand was scheduled for preemployment drug screening, but had been employed as deckhand while vessel operated as a six-pack prior to testing. Owner instructed to conduct preemployment testing prior to operations whether operating under COI or as six-pack LEGACY COMPONENT DESC: Employee Coverage
Action required: 705 - Other - as specified
Due 26 June 2002
Resolved 26 June 2002
Resolution: Owner/operator scheduled drug test
Navigation › Piloting/Steering
Issued 26 June 2002 Resolved
out of date publication LEGACY COMPONENT DESC: US Coast Pilot
Condition: Improper/Lack of Maintenance
Due 26 July 2002
Resolved 21 August 2002
Navigation › Piloting/Steering
Issued 26 June 2002 Resolved
out of date publication LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Due 26 July 2002
Resolved 21 August 2002
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 7 December 2001 Resolved
ATTACH FUEL TANK FILL BOND STRAPS.
Condition: Unknown
Due 11 September 2006
Resolved 11 September 2006
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 7 December 2001 Resolved
REPAIR P/S RPM GAUGES.
Condition: Unknown
Due 11 September 2006
Resolved 11 September 2006
Accommodation/Occupational Safety
Issued 13 June 2000 Resolved
REPLACE BROKEN WINDOW IN STOVE.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Navigation
Issued 13 June 2000 Resolved
PROVIDE STEERING STOPS; CLOSELY MONITOR HYDRAULIC SYSTEM & OPS IN INTERIM.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Documentation
Issued 13 June 2000 Resolved
PROVIDE CURRENT FCC TELEPHONY & OPERATOR CERTIFICATES.
Condition: Unknown
Due 13 June 2000
Resolved 13 June 2000
Construction/Loadline
Issued 19 October 1999 Resolved
REPAIR DELAMINATION MIDSHIP AFT ENGINEROOM BULKHEAD IN LAZERETTE.
Condition: Unknown
Due 21 October 1999
Resolved 21 October 1999
Construction/Loadline
Issued 19 October 1999 Resolved
REPLACE LEAKING NUT AND BOLT ON SKEG INTERNAL AFT OF AFT ENGINEROOM BULKHEAD INBOARD PORT SIDE. CHECK EVERY 4 HOURS WHEN OPERATING UNTIL REPAIRED.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Construction/Loadline
Issued 19 October 1999 Resolved
REPAIR LEAKING PORT & STBD RUDDER BOXES AND DETERMINE SOURCE OF LEAKAGE. CHECK AREA EVERY 4 HOURS WHEN OPERATING UNTIL REPAIRED.
Condition: Unknown
Due 19 October 1999
Resolved 19 October 1999
Construction/Loadline
Issued 15 June 1999 Resolved
MAKE PERMANENT REPAIR TO PORT SKEG HULL FASTENER, SPACER AND HULL DELAMINATION AND RUDDER BOX INTERNAL IN WAY OF SAME AREA.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 15 June 1999 Resolved
REPAIR DELAMINATION ON PORT AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Navigation
Issued 15 June 1999 Resolved
REPLACE 30 FEET OF FLEXIBLE HOSE FOR HYDRAULIC STRG LINE W/APPROVED PIPING.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Construction/Loadline
Issued 15 June 1999 Resolved
MAKE PERMANENT REPAIR TO HOLES IN BOW FROM ANCHOR SHIELD.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Fire Fighting
Issued 15 June 1999 Resolved
PROVIDE FIRE SUPPRESSION AND DETECTION SYSTEM PER 46 CFR 181.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Engineering
Issued 15 June 1999 Resolved
REPLACE STB PROP LOCKNUT W/NEW GROOVED LOCKNUT.
Condition: Unknown
Due 30 September 1999
Resolved 30 September 1999
Engineering
Issued 15 June 1999 Resolved
REPAIR EXHAUST LEAK ON PORT ENGINE.
Condition: Unknown
Due 15 June 1999
Resolved 15 June 1999
Lifesaving
Issued 11 June 1998 Resolved
LIFERING WATERLOGGED. REPLACE AS ORIGINAL NLT 11AUG98.
Condition: Unknown
Due 11 August 1998
Resolved 14 June 1999
Lifesaving
Issued 11 June 1998 Resolved
POST PFD DONNING PLACARD.
Condition: Unknown
Due 11 August 1998
Resolved 14 June 1999
Lifesaving
Issued 11 June 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 August 1998
Resolved 14 June 1999
Lifesaving
Issued 6 July 1995 Resolved
PROVIDE 4 ADDITIONAL ORANGE SMOKES - 1 RED FLARE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Engineering
Issued 6 July 1995 Resolved
PROPERLY MARK EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Navigation
Issued 6 July 1995 Resolved
PROVE PROPER OPERATION OR REMOVE S/S.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Fire Fighting
Issued 6 July 1995 Resolved
PROVE SERVICING OF PORTABLE F/E.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Lifesaving
Issued 6 July 1995 Resolved
RELOCATE LINE AND WATERLIGHT FOR LIFEFLOAT.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Electrical
Issued 6 July 1995 Resolved
PROVIDE ADDITIONAL OPERATIONAL FLASHLIGHT.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Navigation
Issued 6 July 1995 Resolved
PROVIDE CURRENT TIDAL AND TIDAL CURRENT TABLES.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 6 July 1995 Resolved
PROVE PROPER OPERATION OF LAZZARETTE HATCH RELEASE.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Engineering
Issued 6 July 1995 Resolved
REDUCE FLOW OF WATER ON SHAFTS.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Lifesaving
Issued 6 July 1995 Resolved
DEMONSTRATE SR DECHAND COMPETENCY DURING MAN OVERBOARD DRILL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Navigation
Issued 6 July 1995 Resolved
R/R ANCHOR LIGHT.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Electrical
Issued 12 May 1995 Resolved
PROPERLY LINE BATTERY BOX.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 12 May 1995 Resolved
REPAIR HOLE IN CORNER OF STEP, MAIN DECK.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 12 May 1995 Resolved
PROVIDE KEEPER CHAIN FOR W/T HATCH AFT OF HOUSE.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 12 May 1995 Resolved
REPLACE BROKEN WINDOW.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Construction/Loadline
Issued 12 May 1995 Resolved
SCRAPE AND TREAT FURRED WOOD OVERHEAD IN E/R.
Condition: Unknown
Due 20 March 1996
Resolved 20 March 1996
Navigation
Issued 3 May 1991 Resolved
ANCHOR LIGHT NOT OPERATIONAL.
Condition: Unknown
Due 25 May 1991
Resolved 3 September 1991
Lifesaving
Issued 3 May 1991 Resolved
HOLDER FOR LIFE-FLOAT PAINTER HAD BROKEN WELDS. CAUSE UNKNOWN. REQUIRED REPAIR OR REPLACEMENT.
Condition: Unknown
Due 25 May 1991
Resolved 3 September 1991
Lifesaving
Issued 3 May 1991 Resolved
EMERGENCY CHECK-OFF LIST NOT AVAILABLE OR POSTED.
Condition: Unknown
Due 25 May 1991
Resolved 3 September 1991
Engineering
Issued 3 May 1991 Resolved
STBD REMOTE FUE CUT-OFF MISSING DUE TO FAILURE AND PENDING REPLACEMENT.
Condition: Unknown
Due 25 May 1991
Resolved 3 September 1991
Lifesaving
Issued 3 May 1991 Resolved
WATER LIGHT FOR 10 MAN LIFE-FLOAT HAD FRACTURED HOUSING AND DID NOT OPERATE.
Condition: Unknown
Due 25 May 1991
Resolved 3 September 1991
Accommodation/Occupational Safety
Issued 14 June 1988 Resolved
PROVIDE WATERTIGHT COVER FOR VENT IN HEAD.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Electrical
Issued 14 June 1988 Resolved
REPAIR TACHOMETER ON STARBOARD ENGINE.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988
Construction/Loadline
Issued 14 June 1988 Resolved
CONDUCT STABILITY TEST.
Condition: Unknown
Due 14 June 1988
Resolved 14 June 1988

Ownership record