Records from 2008 to 2026. Most recent: inspection, 23 March 2026.
Inspection history · 30
23 March 2026
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8325006
28 June 2025
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8173163
26 June 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8172076
26 March 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8097515
27 February 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7870542
11 December 2023
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7838656
16 August 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7769714
5 August 2023
Type not recorded
No type recorded · USCGC MAKO (WPB 87303) · USCG East District (CGD-E) · Activity 7763846
11 May 2023
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7686069
27 April 2023
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7677362
3 March 2023
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7645172
31 January 2022
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7387134
21 January 2022
COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7361362
28 October 2021
Internal Structural Exam · Drydock Extension
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7341547
20 July 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7263078
19 July 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7260782
17 July 2021
Type not recorded
No type recorded · Station Atlantic City · USCG East District (CGD-E) · Activity 7259515
29 April 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7185787
7 December 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7108090
20 May 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6956739
21 October 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6838479
1 October 2019
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6825835
28 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6696213
10 January 2018
Examination of Repairs · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6332105
3 October 2017
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6277893
18 July 2017
Examination of Repairs · Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6213280
16 July 2017
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6227140
28 February 2017
DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6095325
23 February 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5820424
12 January 2016
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5795635
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 March 2025
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Vessel’s interconnected smoke detection unit was not operational during time of inspection. Vessel is required to have the smoke detection unit operational prior to carrying passengers. 46 CFR 181.450
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2025
Resolution: Resolved issue with interconnected fire detection
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 26 March 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Engine room had excessive oil accumulation and oil-soaked sorbent pads throughout bilge area. Clean accumulated oil and remove pads prior to carry passengers. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2025
Resolution: Cleaned bildge and removed oily rags
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 26 March 2025
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Required alcohol test strips were expired. Provide alcohol test strips prior to carrying passengers. 46 CFR 4.06-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 April 2025
Resolution: Provided proof of new test strips
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 March 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessels Radio safety telephony certificate is expired. Vessel is restricted to 1000 feet from shore. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: Provided valid FCC Radiotelephony Certificate.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 March 2025
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59. Vessels MF radio was inoperable during course of inspection. Vessel is restricted with 20NM from shore until unit is operational. Have FCC inspector verify satisfactory condition of MF radio during renewal of radiotelephony certificate. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 7 April 2025
Resolution: prodived inspection certificate from FCC stating that everything was in operational condition.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 March 2025
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate. Vessels hydrostatic release on EPIRB is expired. Vessel is restricted within 3NM from territorial seas baseline. 46 CFR 180.64
Action required: 705 - Other - as specified
Resolved 1 April 2025
Resolution: Replaced hydrostatic release
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 26 March 2025
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Master of vessel could not produce her medical certificate during inspection. 46 CFR 15.401
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 7 April 2025
Resolution: Provided Medical Certificate
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. Battery in the engine room has exposed wiring and opposite terminal is connected with wing nut. Replace wing nut with permanent means of connection and cover exposed wiring. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 1 April 2025
Resolution: Replaced wing nut and permanently connected wires
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2025
Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter. Type I retro on life ring was faded and peeling off. Owner replaced retro during inspection. 46 CFR 180.70(b)
Action required: 10 - Deficiency Rectified
Resolved 26 March 2025
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 March 2025
Resolved
Each buoyant apparatus must be fitted with a lifeline, pendants, a painter, and a light. 02 paddles attached to life float were broken. Owner replaced both paddles and provided required markings during inspection. 46 CFR 180.75
Action required: 10 - Deficiency Rectified
Resolved 26 March 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 March 2025
Resolved
Flexible nonmetallic hose may be used in lube oil, fuel oil, and power fluid systems, subject to the following requirements: hose runs must be visible, easily accessible, and protected from damage. Flexible hose used for fuel tank cross connection and associated valve is showing signs of wear and deterioration. Replace hose and associated shut off valve handle prior to next credit dry dock.
Action required: 705 - Other - as specified
Resolved 13 May 2026
Resolution: Hose and handle renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 26 March 2025
Resolved
A hatch exposed to the weather must be watertight. Watertight gasket on hatch leading to engine room is deteriorated and unattached.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2025
Resolved 7 April 2025
Resolution: Provided picture of new gasket installed
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 11 December 2023
Resolved
An individual may not serve in a position required by law or regulation to hold a merchant mariner's credential, unless the individual holds all credentials required. Vessel operator has expired medical certificate. Actions should be taken immediately to rectify issue prior to operating the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2023
Resolved 18 December 2023
Resolution: Vessel operator sent in confirmation email from maritime center saying they'd recieved her updated physical.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 3 March 2023
Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. Because the Coast Guard considers proof of medical fitness as an essential part of the merchant mariner credential, it is required to be kept on board in the plastic sleeve provided on the last page. Vessel master was unable to provide proof of medical fitness upon request.
Provide medical certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 11 May 2023
Resolution: Provided photo of medical card
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 January 2022
Resolved
All machinery be installed and maintained in such manner to afford adequate protection against fire, explosion, machinery failure and personnel injury. Install guard on forward part of engine with moving belt. 46 CFR 182.01-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 9 March 2022
Resolution: Wooden guard was installed. Cleared during DD inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2022
Resolved
Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route must have a life jacket light approved in accordance with 161.012. Replace 2 adult life and 1 child life jacket light batteries. 46 CFR 180.75(a)
Action required: 10 - Deficiency Rectified
Due 21 January 2022
Resolved 21 January 2022
Resolution: Vessel owner replaced life jacket lights.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so child size life jackets aren’t mistaken for adult life jackets. Separate child size life jackets from adult life jackets. 46 CFR 180.78 (a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 31 January 2022
Resolution: On the port side of the vsl, the child lifejackets are stored in the same container as the adult lifejackets but are seperated by a divider; USCG is satisfied with this arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 January 2022
Resolved
Each life jacket kept in a stowage container must be readily accessible. Remove tarp around life jackets on port side life jacket stowage to allow life jackets to be readily accessible. 46 CFR 180.78(a)(2).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 31 January 2022
Resolution: The tarp was rearranged to make the lifejackets on the port side of the vsl readily accessible; USCG satisfied with this arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 January 2022
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Label life float paddles with vessel name. 46 CFR 185.604(g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 8 March 2022
Resolution: O/O provided photos of paddles that were marked appropriately.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2022
Resolved
Junction boxes, connection boxes and outlet boxes, for use in damp or wet locations shall be of watertight construction. Replace wooden cover on junction box in engine room. 46 CFR 183.10-20(k)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 9 March 2022
Resolution: Junction box was replaced in kind. Cleared during DD inspection.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 January 2022
Resolved
Marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. Pump/clean engine room bilges. 46 CFR 176.25-50(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 31 January 2022
Resolution: Bilges were clean on 31JAN2022 when USCG was in attendance.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 January 2022
Resolved
Marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Tidy up wiring in engine room compartment. 46 CFR 176.25-50(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2022
Resolved 9 March 2022
Resolution: Wiring was cleaned up by re-routing wires and groupig wires together. Cleared during DD inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 October 2021
Resolved
Significant pitting was found in way of the lazarette multiple frames to port and starboard from the keel and forward from the transom past the rudder post. Random sample of pits indicated greater than 50% wastage from the as-built 1/4" scantlings of 5068-H116 aluminum hull plating. Determine the extent of pitting requiring to be repaired/replaced and submit proposal for doing so at the next drydock scheduled no later than 31JAN2022.
CITE: 46 CFR §177.10-1 Old T
Action required: 705 - Other - as specified
Due 31 January 2022
Resolved 31 March 2022
Resolution: Entire section was cropped and renewed during drydock. See activity 7387134
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 7 December 2020
Resolved
Each Collision Bulkhead may have penetrations and openings that are located as high and as far inboard as practical; and have means to make them watertight. The forward Collision Bulkhead is not watertight due to a 1 inch diameter drain hole at the lowest point penetrating the Collision Bulkhead rendering the watertight bulkhead ineffective. Permanent repairs need to be made to replace the 'drain plug' currently in place, propose plan to marine inspectors with-in 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2021
Resolved 3 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020
Resolved
A vessel of 12 meters or more in length but less than 50 meters in length shall have sidelights visible of at least 2 miles. Vessel Port light was not visible more than 1 ft. Replace port light. Vessel restricted to daylight operations only until fixed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2020
Resolved 10 December 2020
Resolution: Replaced port light restoring required visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 December 2020
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. Two Life Float paddles were broken. Replace broken paddles and re-lash to life floats.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 December 2020
Resolution: Replaced Life Float Oars.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 December 2020
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. Each paddle did not have the vessel name marked or painted on.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2021
Resolved 10 December 2020
Resolution: Appropriately labeled new paddels with Vessel Name.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 7 December 2020
Resolved
Each child life jacket must be marked and stowed in a location separate from Adult life jackets. Child and Adult life jackets were stored together and not properly segregated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 January 2021
Resolved 10 December 2020
Resolution: Separated Child and Adult Life Jackets and labled the specific location for all Child Life jackets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 20 May 2020
Resolved
03110 Each hatch exposed to the weather deck must be watertight. Replace gasket on engine room watertight hatch. 46CFR(Old-S)171.124(a) 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 June 2020
Resolved 7 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 20 May 2020
Resolved
Remove zipties from grab lines and painter on life floats. Def corrected on the spot. 46 CFR 180.130(a)(3) 10c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2020
Resolved 20 May 2020
Resolution: Corrected on the spot
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 October 2019
Resolved
Toilet sea water intake valve has 90 degree elbow at hull and could not be examined. Valve must be removed and made available for inspection when boat is removed from water in January 2020. Due date extended to January 31, 2020.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2019
Resolved 13 May 2020
Resolution: [name withheld] saw this valve in person at Yanks marine back in January of 2020 but we forgot to clear the def in misle.//[name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2019
Resolved
Crew and Passenger List has not been kept for each voyage with overnight passengers. 46 CFR 185.502
Action required: 10 - Deficiency Rectified
Due 1 October 2019
Resolved 1 October 2019
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 October 2019
Resolved
Install Emergency Lighting in Overnight Passenger Accommodations. Emergency Lighting must turn on automatically upon failure of main lighting system. Passengers are prohibited from accessing the space between sunset and sunrise until this is installed. 46 CFR "Old T" 184.30-5
Action required: 705 - Other - as specified
Due 1 November 2019
Resolved 7 December 2020
Resolution: Vessel no longer operating with overnight passenger accomodations.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 May 2019
Resolved
Provide current hydrostatic release for EPIRB with the appropriate expiration date marked. - 46 CFR 185.740
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 9 October 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2019
Resolved
Attach proper 60ft lifeline to the ring life buoy that meets 46 CFR 180.20 requirements. - 46 CFR 180.20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2019
Resolved 29 May 2019
Resolution: Master provided a life line while the MIs were still onboard.
Lifesaving › Lifefloat › Platform
Issued 18 January 2018
Resolved
MAB07: Make lifefloats available to be safely launched by crewmembers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 1 February 2018
Lifesaving › Lifefloat › Float Free
Issued 18 January 2018
Resolved
MAB08: Placed spacers in between lifefloats.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 February 2018
Resolved 1 February 2018
Engineering › Bilge Water Management System › Valve
Issued 10 January 2018
Resolved
MAB01: Bilge line for the submersible pump must have a positive shutoff valve. Stbd side bilge line in ER missing shutoff valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 9 October 2019
Engineering › Fuel Oil Service System › Valve
Issued 10 January 2018
Resolved
MAB02: Valve for removing water or impurities from fuel in strainers must be permanent. Petcock installed on fuel strainer is not permanent.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2018
Resolved
Wiring, where subject to mechanical damage shall be protected. Junction box in ER missing guard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 January 2018
Resolved
MAB04: Replace/ repair 01 child life jacket. Child carrying capacity reduced to 02 children.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 22 May 2018
Resolution: Receibed satisfactory picture on 19 May 2018.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 January 2018
Resolved
MAB05: Vessel must carry one floating waterlight which is inoperable. Daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Lifesaving › Visual Distress Signals (General) › Approval
Issued 10 January 2018
Resolved
MAB06: EPIRB battery must be replaced before required by FCC. Battery is expired. Operating area reduced to w/i 3 NM.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 February 2018
Resolved 18 January 2018
Construction/Loadline › Penetrations › Pipe Flange
Issued 3 October 2017
Resolved
RT01: Replace through hull plate around hydraulic line penetrating collision bulkhead. 46CFR 182.720 Due 17 OCT 2017.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 20 October 2017
Resolution: Visually verified flange installed on hydraulic line prenetrating collision bulkhead.
Electrical › Electric Supply System (service) › Cable
Issued 3 October 2017
Resolved
RT02: Provide electrical drawing to include all modified electrical equipment, wire gauge, loads, and breakers. PTCP
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 20 October 2017
Resolution: Electrical plan submitted and approved by [name withheld].
Electrical › Electric Supply System (service) › Cable
Issued 3 October 2017
Resolved
RT03: Verify operation of electrical operation in presence of Marine Inspector. PTCP
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 20 October 2017
Resolution: Tested raido and navigation equipment while underway.
Communications › Radio Communications › Satellite Communications Capability
Issued 3 October 2017
Resolved
RT04: Install operational Single Side Band Radio Prior to operating beyond coastwise route.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 21 November 2017
Resolution: Verified installation and operation of newly installed SSB.