Records from 2016 to 2026. Most recent: inspection, 19 March 2026.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2025
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service for whcih they are intended: (1)Maine propulsion machinery. Both shaft seals were found leaking more than normal. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 February 2024
Resolved
A dry-dock examination conducted in compliance with 176.600 must be conducted while the vessel is hauled out of the water or placed in a dry-dock or slipway. Identified 2" area of rot ivo wind and water portside hull near bow. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024
Resolved
...Identified 3" soft area on port-side hull ivo wind and water profile. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024
Resolved
...Identified 6" soft area on portside hull midships ivo wind and water profile. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024
Resolved
...Rotted wood plank found on stern port-side at the top. Provide repair plan and renew with in kind materials and fasteners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Removed section of rotted plank. Install section of approx 6' new plank that landed between frames. Butt block instlled.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024
Resolved
...Rod room: 4 keel drift pins found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed 04 carriage bolts in lieu of drift pins.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024
Resolved
...Rod room: Stbd overhead transverse deck beam found 4" section of rot. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Section of deck beam was clean out and treated with epoxy, deteriotion was less than 10%.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024
Resolved
...Rod room: Found rot on portside 2nd frame fwd of front engine room bulkhead near chine. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Gouged out area of rot. 85% of good wood remains; filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024
Resolved
..Rod room: Butt block between 4th and 5th frames fwd of engine room bulkhead portside was found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Butt block renewed in kind, installed proper amount of fasteners.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 February 2024
Resolved
...Engine room: Signs of angel hair found on overhead plywood behind main engines. Treat wood or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Angel hair was removed. MI advised owner for better ventilation to avoid further deteriation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024
Resolved
...Engine room: Missing bolt on Starboard butt block between frames 10 and 11 aft of fwd engine room bulkhead. Renew in kind.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed proper bolt.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024
Resolved
...Engine room: Found transverse deck beam loose and missing hardware. Renew hardware as marked and properly tighten.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed fastener and secured.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 February 2024
Resolved
...Port upper cabin below rail identified rot. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Section of rotted rail was cropped out and renewed in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 13 February 2024
Resolved
...Found rot on gunwale to cabin joint on starboard side. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Cabin joint section was cropped and renewed in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 February 2024
Resolved
...Owner pointed out approx 4'X4' rotted section of wood under cabin windows starboard side. Crop out to good wood and renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: 4' x 4' section of plywood was cropped out and renewed with marine type plywood.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2024
Resolved
The cognizant OCMI may require that a vessel and it's equipment undergo any additional inspection to determine the vessel is suitable for service. Pull fasteners as marked by the [name withheld] as necessary.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 February 2024
Resolution: Pulled 17 fasteners in the presence of MI and documented on fastening inspection record that was uploaded in misle documents tab.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 September 2023
Resolved
Whenever damage or deterioration to hull plating is discovered the OCMI is to be notified and repairs made. Vsl found a deteriorated board on the STBD bow. Vsl must conduct repairs iaw approved plans. 46 CFR 176.600
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: MI attended vessel and inspected repair. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2023
Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Vessel's COI expired 05Jul23. Conduct a COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2023
Resolution: Hull/ISE and COI conducted iaw applicable laws, regulations and 840 book.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2023
Resolved
Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Vessel owner could not prove C/TPA enrollment to implement Drug/Alcohol program during the inspection.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 26 July 2023
Resolution: Employer is properly enrolled in drug/alcohol consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 July 2023
Resolved
Arrangements not covered by standards in this sub-chapter may be inspected in accordance with standards as good marine practice. Re-route bitter end of life-float painter to be direct to the attachment point with no interferences.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Break-Free Link has been routed correctly, worth noting link is not required based on vessels route and water depth see NVIC 1-83
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 July 2023
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Battery for life ring buoy water light found expired.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Waterlight battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 July 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post instruction
placards for proper style life jackets onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Applicable life jacket instructions have been posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2023
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Revised stability letter has been re-issued and is posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2023
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge. Remove extension wires located in P&S distribution boxes using proper length of conductors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: All excess pig tails have been removed and cabling directly wired in distribution panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket on board was found un-serviceable. Vessel restricted to 21 persons total.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2022
Resolved 13 October 2022
Resolution: One adult life jacket renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 September 2022
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. No indicators installed for electric pumps.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 October 2022
Resolution: Visual indicators installed on pilothouse for all automatic bilge pumps.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 September 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications IAW 46 CFR 184.420(a). Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. All pubs on board are outdated. In lieu of updated charts, make appropriate corrections.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 13 October 2022
Resolution: Pubs and charts updated and onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 September 2022
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radio-beacon (EPIRB). EBIRB is not properly marked with vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 13 October 2022
Resolution: EPIRB properly marked with vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2022
Resolved
Power conductors for interior wiring shall be insulated in accordance with table 183.05-45(e). Insulation was missing on several cables leading from port engine room battery. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 13 October 2022
Resolution: Cables were renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2022
Resolved
Conductors shall be protected from over-current in accordance with their current-carrying capacities as given in Table 183.05-45(a). Prove to the Marine Inspector that power conductors from port battery to electric pumps are properly protected.
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 13 October 2022
Resolution: Overcurrent protection provided for electrical sub pumps.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 September 2022
Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deck-house sides, at ladders and hatches where passengers or crew might have normal access. The following locations are missing storm rails or hand grabs:
1. Port and starboard deck-house sides leading to bow.
2. Ladder leading from pilothouse to cockpit.
Submit a plan to the USCG for approval and install to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 October 2022
Resolution: Hand grabs at locations noted by Inspector were installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2021
Resolved
Vsl requires Drug and Alcohol program. Provide proof of enrollment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Provided proof of program and enrollment.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 July 2021
Resolved
Vsl required Nav pubs and charts, tide table for AOR. Provide proof of paper work onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Master provided proof of proper nav pubs, tide tables, and charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 July 2021
Resolved
M/I noticed small leak port side on butt block IVD #8 frame aft of E/R BHD. Provide log and or repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2021
Resolved 21 July 2021
Resolution: Master provided objective evidence butt block was not leaking. Resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 21 July 2021
Resolved
Vsl requires ring buoy with float light. Battery was wrong type and ring is needing remarking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 19 August 2021
Resolution: Inspected to the satisfaction of the attending marine inspector this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2021
Resolved
Required to maintain fuel oil service system. Port engine fuel return line is loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Master provided proof the loose return line was properly tighten.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2021
Resolved
Exhaust riser on port engine 01 hose clamp is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2021
Resolved 21 July 2021
Resolution: Master provided proof the loose return line was properly tighten.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2021
Resolved
Conduct drills in company of Coast Guard. (Fire and man overboard)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2021
Resolved 19 August 2021
Resolution: Drills were conducted and witnessed satisfactory this date, by the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2020
Resolved
Replace worn fire hose with 3/4" x 25' iaw 46 CFR 181.320 (c) 1& 2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2020
Resolved
Port engine exhuast shows signs of leaking, determine and inspect to the satisfaction of the attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 6 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 July 2020
Resolved
The main starting batteries had signs of corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 July 2020
Resolved
Remove water from bilges, inspect, and clean drain holes to ensure they are free of obstructions and draining as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 July 2020
Resolved
Replace the battery in the float light, past expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020
Resolved
Replace worn line on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020
Resolved
The ring buoy was missing retro tape.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 July 2020
Resolved
Provide vessel log for drills and safety equipment and conduct additional training and log as required.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 October 2019
Resolved
Rescue platform neededs to be remounted in the stern of the vessel to accomadate one crew member being able to properly assist in MOB.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 October 2019
Resolved
CPR first aid expired
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2019
Resolved
Exhaust lagging held in place with electrical tape, reinstall with proper lagging wire.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2019
Resolved
Exhaust system temp repaired with JB weld. STBD exhaust outboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Found multiple bilge clamps and fittings loose on bilge system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: All clamps found to be in place and tight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Port and Starboard engines has several raw water hoses which are worn, cracked, and missing hose clamps. Several clamps installed are wasted and or rusted.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: All r/w hose replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Starboard outboard of engine exhaust lagging is oil soaked and has suspected raw water leak at the inlet piping at wet exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: Wet exhaust found to have pin hole and o/o stated that he had it welded as a repair and new lagging was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Starboard outboard reduction gear mount is loose and missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: New mount installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
Port engine raw water pump housing is missing hardware and appears to be leaking from gasket as a result.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: New hardware installed and not leaking
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 October 2019
Resolved
Provide proof of drug testing for master and crewmembers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: Provided approval/ enrollment information.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2019
Resolved
Make proper repairs to the vessels life float ivo data plate.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Life float repaired
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 October 2019
Resolved
Renew the line on life float (install around eye) and properly rig.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Line around body of life float
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2019
Resolved
Replace float light with approved kind. Prior to night operations or nte 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 October 2019
Resolved 30 October 2019
Resolution: New float light installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019
Resolved
Prove proper operation of all electrical and navigation equipment. Additionally, conduct fire and man overboard drill to the satisfaction of the attending inspector once all prior to passengers are completed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: All equipment tested and drills conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019
Resolved
The port engine heat exchanger mount is damaged and worn. Repair or replace inkind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Replaced heat exchanger mount.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2019
Resolved
The port engine cooling hose is showing signs of damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 12 April 2019
Resolution: Found satisfactory to the attending inspectior.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 June 2018
Resolved
Vessel port and stbd MDE sea chest hoses are missing and have broken clamps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and confirmed replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2018
Resolved
Port engine shaft packing was leaking excessive.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 19 June 2018
Resolved
Vessels first aid kit is missing ammonia.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 6 July 2018
Resolution: Found satisfactory to the attending M/I.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 June 2018
Resolved
Vessels visual bilge alarms is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2018
Resolved
Vessels fire buckets needed to be remarked and missing layards.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 June 2018
Resolved
Provide documentation for Hydro release.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 6 July 2018
Resolution: Found satisfactory to the attending M/I.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 June 2018
Resolved
Engine room bilge pump suction discharge hose clamp was loose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 19 June 2018
Resolved
Conduct man overboard and fire drills.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 6 July 2018
Resolution: Removed requirement due to weather, discuss, found acceptable to the attending M/I.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 June 2018
Resolved
Conduct sea trials and operational test of the vessels fire-boy fire system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 6 July 2018
Resolution: Verified and cleared by the attending M/I.
Engineering › Steering Gear System › Rudder Bearing
Issued 8 August 2017
Resolved
Port side rudder packing leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Tighted Rudder packing nut
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017
Resolved
Shaft log missing hose clamp STBD side
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Added one hose clamp to shaft log
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 8 August 2017
Resolved
STBD engine and R/G mounts loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Tightened Engine mount to R/G
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2017
Resolved
Install two hose clamps on STBD wet exhaust
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Installed two new hose clamps to wet exhaust.
Communications › Radio Communications › EPIRB
Issued 8 August 2017
Resolved
provide proper paperwork for EPIRB. Current paperwork doesnt have correct make model and numbers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2017
Resolution: Contacted NOAA and recieved e-mail of corrcet info. Once hard copy arrives to vessel the owner will submit to CG.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 August 2017
Resolved
Missing COD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2017
Resolution: E-mailed copy to CG.
Construction/Loadline › Structures › Deck Plating
Issued 8 August 2017
Resolved
Make temp repairs to port side outboard 2 ft from transom. Deck is soft and has hole in it. Deck is to be cut out and repaired at next dry dock NLT Mar 2018.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 14 August 2017
Resolution: Made temp repairs in aft deck to ensure water is sealed from entering hull. Vessel will need to repair aft deck after season and during dry dock.
Communications › Radio Communications › EPIRB
Issued 25 July 2016
Resolved
EPIRB battery expires in AUG.
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 31 August 2016
Resolution: A new EPIRB installed on vessel.
Construction/Loadline › Hull › Hull Plating
Issued 25 July 2016
Resolved
Leaking butt blocks STBD FWD IWO cabin.
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 15 June 2018
Resolution: Reviewed and closed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 July 2016
Resolved
Expired Fire ext. in the wheelhouse.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: old ext. removed from wheel house and a new ext. was installed. All SAT.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2016
Resolved
Expired Alcohol test strips
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Old strips removed and three new strips added with exp date of 2017.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2016
Resolved
Clean port engine to started battery cable connection
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Cleaned starter cable to battery terminals.
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016
Resolved
Remove decayed wood IWO port frames 5-7 from fwd engine room blkhd to good wood (paint to prevent further decay)
Due 17 April 2016
Resolved 4 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2016
Resolved
Secure overhead wires in stbd engine room fwd
Due 17 April 2016
Resolved 4 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 17 March 2016
Resolved
Provide support to STBD engine mount
Due 17 April 2016
Resolved 4 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016
Resolved
Remove angel hair in fwd engine room to good wood
Due 17 April 2016
Resolved 4 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016
Resolved
Remove decay IWP transverse frame near port exhaust to good wood & pain to prevent further damage
Due 17 April 2016
Resolved 4 May 2016