NANCY LEE III

NANCY LEE III is a 1980 passenger vessel (inspected). The Coast Guard has recorded 81 inspections since 1985, most recently in March 2026, along with 168 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1980
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP5305
Flag
UNITED STATES
368362190
Maury page id
psix-52270

Inspections, by type

…with no type recorded8
Years with a record 39 calendar years (1985–2026)
The 81 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.6 ft × 15.2 ft × 6.9 ft
Registered tonnagegross 29 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN WILLARD DUDLEY · SWANSBORO, NC, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSWANSBORO, NC
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 10 April 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Gross Ton
20 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP5305MMSI 368362190 · active · compulsorily equipped · granted 13 April 2024, expires 13 April 2034
WYQ6874MMSI 366941480 · expired · compulsorily equipped · granted 22 April 2014, cancelled 6 July 2024
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 81

19 March 2026 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8327411
25 April 2025 Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8098543
17 September 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7995527
18 March 2024 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7990500
13 February 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7864768
26 September 2023 Damage Survey · In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7798455
24 July 2023 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7751061
28 September 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7566129
14 February 2022 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7393632
21 July 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7234610
27 July 2020 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7013979
24 March 2020 Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6929672
14 October 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6830409
20 March 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6646144
19 June 2018 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6448873
19 March 2018 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6372089
8 August 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6206759
1 November 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6033699
31 August 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5989253
15 August 2016 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5973509
25 July 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5945640
17 March 2016 Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5831377
27 July 2015 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5169060
26 March 2014 Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4823652
18 June 2012 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4336396
3 March 2010 Drydock Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3688721
16 July 2008 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3263701
17 March 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3168346
8 June 2007 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2955150
15 March 2006 Hull Examination · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2606850
17 August 2005 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2471457
15 June 2004 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2100104
30 March 2004 Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 2479203
27 May 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1803098
14 May 2002 Annual Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1615992
17 April 2002 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1604903
8 November 2001 Administrative
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1075704
9 April 2001 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1439174
27 September 2000 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1455916
19 April 2000 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1437702
4 December 1999 Type not recorded
No type recorded · USCGC BLOCK ISLAND (WPB 1344) · USCG East District (CGD-E) · Activity 1507193
15 April 1999 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1372581
7 April 1999 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1459489
12 March 1999 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 807089
22 April 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 643385
9 April 1998 Deficiency Check · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 787054
3 December 1997 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1112542
10 November 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 643384
29 October 1997 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1414895
17 October 1997 Drydock Extension
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1113401
16 October 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 213615
16 October 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 220564
20 March 1997 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1096739
18 September 1996 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1437153
8 February 1996 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 876807
15 September 1995 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 874739
20 April 1995 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1340651
3 April 1995 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1150316
11 April 1994 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 857792
23 September 1993 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 841487
13 April 1993 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 835028
29 December 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 832178
2 July 1992 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 949841
14 April 1992 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1269064
24 March 1992 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258819
6 August 1991 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1251649
28 February 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 924353
26 September 1990 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 909600
13 August 1990 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 926362
8 August 1989 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1343144
8 March 1989 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 893675
4 August 1988 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1342654
22 October 1987 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1328165
30 September 1987 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1322823
24 August 1987 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1031363
12 January 1987 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1006858
12 August 1986 COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 990374
14 March 1986 Credit Drydock
Administrative · THE UNKNOWN UNIT · Activity 996470
14 November 1985 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1292927
4 September 1985 Re-Inspection
Physical examination · THE UNKNOWN UNIT · Activity 1299503
4 January 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 976138

Deficiency record · 168

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 April 2025 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition and fit for the service for whcih they are intended: (1)Maine propulsion machinery. Both shaft seals were found leaking more than normal. Make repairs and test to the satisfaction of attending CG Marine Inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 May 2025
Resolved 20 May 2025
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 13 February 2024 Resolved
A dry-dock examination conducted in compliance with 176.600 must be conducted while the vessel is hauled out of the water or placed in a dry-dock or slipway. Identified 2" area of rot ivo wind and water portside hull near bow. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024 Resolved
...Identified 3" soft area on port-side hull ivo wind and water profile. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024 Resolved
...Identified 6" soft area on portside hull midships ivo wind and water profile. Sand marked area for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Area was sand down to good wood. Filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 February 2024 Resolved
...Rotted wood plank found on stern port-side at the top. Provide repair plan and renew with in kind materials and fasteners.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Removed section of rotted plank. Install section of approx 6' new plank that landed between frames. Butt block instlled.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024 Resolved
...Rod room: 4 keel drift pins found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed 04 carriage bolts in lieu of drift pins.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024 Resolved
...Rod room: Stbd overhead transverse deck beam found 4" section of rot. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Section of deck beam was clean out and treated with epoxy, deteriotion was less than 10%.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024 Resolved
...Rod room: Found rot on portside 2nd frame fwd of front engine room bulkhead near chine. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Gouged out area of rot. 85% of good wood remains; filled in with epoxy after wood was dry.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 13 February 2024 Resolved
..Rod room: Butt block between 4th and 5th frames fwd of engine room bulkhead portside was found wasted. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Butt block renewed in kind, installed proper amount of fasteners.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 13 February 2024 Resolved
...Engine room: Signs of angel hair found on overhead plywood behind main engines. Treat wood or replace.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Angel hair was removed. MI advised owner for better ventilation to avoid further deteriation.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024 Resolved
...Engine room: Missing bolt on Starboard butt block between frames 10 and 11 aft of fwd engine room bulkhead. Renew in kind.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed proper bolt.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 13 February 2024 Resolved
...Engine room: Found transverse deck beam loose and missing hardware. Renew hardware as marked and properly tighten.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 22 February 2024
Resolution: Installed fastener and secured.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 13 February 2024 Resolved
...Port upper cabin below rail identified rot. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Section of rotted rail was cropped out and renewed in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 13 February 2024 Resolved
...Found rot on gunwale to cabin joint on starboard side. Clean marked area back to good wood for further evaluation. Provide repair plan to satisfaction of attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: Cabin joint section was cropped and renewed in kind.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 13 February 2024 Resolved
...Owner pointed out approx 4'X4' rotted section of wood under cabin windows starboard side. Crop out to good wood and renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2024
Resolution: 4' x 4' section of plywood was cropped out and renewed with marine type plywood.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 February 2024 Resolved
The cognizant OCMI may require that a vessel and it's equipment undergo any additional inspection to determine the vessel is suitable for service. Pull fasteners as marked by the [name withheld] as necessary.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 14 February 2024
Resolution: Pulled 17 fasteners in the presence of MI and documented on fastening inspection record that was uploaded in misle documents tab.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 September 2023 Resolved
Whenever damage or deterioration to hull plating is discovered the OCMI is to be notified and repairs made. Vsl found a deteriorated board on the STBD bow. Vsl must conduct repairs iaw approved plans. 46 CFR 176.600
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 2 October 2023
Resolution: MI attended vessel and inspected repair. All Sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 July 2023 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. Vessel's COI expired 05Jul23. Conduct a COI inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2023
Resolution: Hull/ISE and COI conducted iaw applicable laws, regulations and 840 book.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2023 Resolved
Marine employers may form or otherwise use sponsoring organizations, or may use contractors, to conduct the random chemical testing programs required by this part. Vessel owner could not prove C/TPA enrollment to implement Drug/Alcohol program during the inspection.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 26 July 2023
Resolution: Employer is properly enrolled in drug/alcohol consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 24 July 2023 Resolved
Arrangements not covered by standards in this sub-chapter may be inspected in accordance with standards as good marine practice. Re-route bitter end of life-float painter to be direct to the attachment point with no interferences.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Break-Free Link has been routed correctly, worth noting link is not required based on vessels route and water depth see NVIC 1-83
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 July 2023 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. Battery for life ring buoy water light found expired.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Waterlight battery replaced.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 24 July 2023 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post instruction placards for proper style life jackets onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Applicable life jacket instructions have been posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 July 2023 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: Revised stability letter has been re-issued and is posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 July 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge. Remove extension wires located in P&S distribution boxes using proper length of conductors.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 August 2023
Resolved 2 August 2023
Resolution: All excess pig tails have been removed and cabling directly wired in distribution panel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 September 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. One adult life jacket on board was found un-serviceable. Vessel restricted to 21 persons total.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2022
Resolved 13 October 2022
Resolution: One adult life jacket renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 September 2022 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. No indicators installed for electric pumps.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 October 2022
Resolution: Visual indicators installed on pilothouse for all automatic bilge pumps.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 28 September 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date nautical publications IAW 46 CFR 184.420(a). Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. All pubs on board are outdated. In lieu of updated charts, make appropriate corrections.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 13 October 2022
Resolution: Pubs and charts updated and onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 28 September 2022 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radio-beacon (EPIRB). EBIRB is not properly marked with vessel's name.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2022
Resolved 13 October 2022
Resolution: EPIRB properly marked with vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2022 Resolved
Power conductors for interior wiring shall be insulated in accordance with table 183.05-45(e). Insulation was missing on several cables leading from port engine room battery. Renew in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 13 October 2022
Resolution: Cables were renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 September 2022 Resolved
Conductors shall be protected from over-current in accordance with their current-carrying capacities as given in Table 183.05-45(a). Prove to the Marine Inspector that power conductors from port battery to electric pumps are properly protected.
Action required: 705 - Other - as specified
Due 5 October 2022
Resolved 13 October 2022
Resolution: Overcurrent protection provided for electrical sub pumps.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 28 September 2022 Resolved
Suitable storm rails or hand grabs shall be installed where necessary in all passageways, at deck-house sides, at ladders and hatches where passengers or crew might have normal access. The following locations are missing storm rails or hand grabs: 1. Port and starboard deck-house sides leading to bow. 2. Ladder leading from pilothouse to cockpit. Submit a plan to the USCG for approval and install to the satisfaction of the attending Marine Inspector.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2022
Resolved 13 October 2022
Resolution: Hand grabs at locations noted by Inspector were installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2021 Resolved
Vsl requires Drug and Alcohol program. Provide proof of enrollment.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Provided proof of program and enrollment.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 21 July 2021 Resolved
Vsl required Nav pubs and charts, tide table for AOR. Provide proof of paper work onboard.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Master provided proof of proper nav pubs, tide tables, and charts.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 July 2021 Resolved
M/I noticed small leak port side on butt block IVD #8 frame aft of E/R BHD. Provide log and or repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2021
Resolved 21 July 2021
Resolution: Master provided objective evidence butt block was not leaking. Resolved to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 21 July 2021 Resolved
Vsl requires ring buoy with float light. Battery was wrong type and ring is needing remarking.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 19 August 2021
Resolution: Inspected to the satisfaction of the attending marine inspector this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2021 Resolved
Required to maintain fuel oil service system. Port engine fuel return line is loose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 August 2021
Resolved 21 July 2021
Resolution: Master provided proof the loose return line was properly tighten.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 July 2021 Resolved
Exhaust riser on port engine 01 hose clamp is missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 July 2021
Resolved 21 July 2021
Resolution: Master provided proof the loose return line was properly tighten.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 July 2021 Resolved
Conduct drills in company of Coast Guard. (Fire and man overboard)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 August 2021
Resolved 19 August 2021
Resolution: Drills were conducted and witnessed satisfactory this date, by the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 July 2020 Resolved
Replace worn fire hose with 3/4" x 25' iaw 46 CFR 181.320 (c) 1& 2.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 July 2020 Resolved
Port engine exhuast shows signs of leaking, determine and inspect to the satisfaction of the attending inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 6 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 July 2020 Resolved
The main starting batteries had signs of corrosion.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 27 July 2020 Resolved
Remove water from bilges, inspect, and clean drain holes to ensure they are free of obstructions and draining as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 July 2020 Resolved
Replace the battery in the float light, past expiration date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020 Resolved
Replace worn line on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 July 2020 Resolved
The ring buoy was missing retro tape.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 27 July 2020 Resolved
Provide vessel log for drills and safety equipment and conduct additional training and log as required.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 July 2020
Resolved 4 August 2020
Resolution: The deficiency was rectified to the satisfaction of the attending inspector.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 30 October 2019 Resolved
Rescue platform neededs to be remounted in the stern of the vessel to accomadate one crew member being able to properly assist in MOB.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 October 2019 Resolved
CPR first aid expired
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2019 Resolved
Exhaust lagging held in place with electrical tape, reinstall with proper lagging wire.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 October 2019 Resolved
Exhaust system temp repaired with JB weld. STBD exhaust outboard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2019
Resolved 3 December 2019
Resolution: Found satisfactory to the attending inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Found multiple bilge clamps and fittings loose on bilge system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: All clamps found to be in place and tight
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Port and Starboard engines has several raw water hoses which are worn, cracked, and missing hose clamps. Several clamps installed are wasted and or rusted.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: All r/w hose replaced with new
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Starboard outboard of engine exhaust lagging is oil soaked and has suspected raw water leak at the inlet piping at wet exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: Wet exhaust found to have pin hole and o/o stated that he had it welded as a repair and new lagging was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Starboard outboard reduction gear mount is loose and missing hardware.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: New mount installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
Port engine raw water pump housing is missing hardware and appears to be leaking from gasket as a result.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: New hardware installed and not leaking
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 15 October 2019 Resolved
Provide proof of drug testing for master and crewmembers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2019
Resolved 30 October 2019
Resolution: Provided approval/ enrollment information.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2019 Resolved
Make proper repairs to the vessels life float ivo data plate.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Life float repaired
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 October 2019 Resolved
Renew the line on life float (install around eye) and properly rig.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Line around body of life float
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 October 2019 Resolved
Replace float light with approved kind. Prior to night operations or nte 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 October 2019
Resolved 30 October 2019
Resolution: New float light installed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 October 2019 Resolved
Prove proper operation of all electrical and navigation equipment. Additionally, conduct fire and man overboard drill to the satisfaction of the attending inspector once all prior to passengers are completed.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: All equipment tested and drills conducted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 October 2019 Resolved
The port engine heat exchanger mount is damaged and worn. Repair or replace inkind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2019
Resolved 30 October 2019
Resolution: Replaced heat exchanger mount.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2019 Resolved
The port engine cooling hose is showing signs of damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2019
Resolved 12 April 2019
Resolution: Found satisfactory to the attending inspectior.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 June 2018 Resolved
Vessel port and stbd MDE sea chest hoses are missing and have broken clamps.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and confirmed replacement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 June 2018 Resolved
Port engine shaft packing was leaking excessive.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 19 June 2018 Resolved
Vessels first aid kit is missing ammonia.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 6 July 2018
Resolution: Found satisfactory to the attending M/I.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 June 2018 Resolved
Vessels visual bilge alarms is inoperative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 June 2018 Resolved
Vessels fire buckets needed to be remarked and missing layards.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 19 June 2018 Resolved
Provide documentation for Hydro release.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2018
Resolved 6 July 2018
Resolution: Found satisfactory to the attending M/I.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 June 2018 Resolved
Engine room bilge pump suction discharge hose clamp was loose.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 July 2018
Resolved 6 July 2018
Resolution: M/I attended vsl and found noted corrected.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 19 June 2018 Resolved
Conduct man overboard and fire drills.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 6 July 2018
Resolution: Removed requirement due to weather, discuss, found acceptable to the attending M/I.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 June 2018 Resolved
Conduct sea trials and operational test of the vessels fire-boy fire system.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2018
Resolved 6 July 2018
Resolution: Verified and cleared by the attending M/I.
Engineering › Steering Gear System › Rudder Bearing
Issued 8 August 2017 Resolved
Port side rudder packing leaking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Tighted Rudder packing nut
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 August 2017 Resolved
Shaft log missing hose clamp STBD side
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Added one hose clamp to shaft log
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 8 August 2017 Resolved
STBD engine and R/G mounts loose
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Tightened Engine mount to R/G
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2017 Resolved
Install two hose clamps on STBD wet exhaust
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2017
Resolved 9 August 2017
Resolution: Installed two new hose clamps to wet exhaust.
Communications › Radio Communications › EPIRB
Issued 8 August 2017 Resolved
provide proper paperwork for EPIRB. Current paperwork doesnt have correct make model and numbers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2017
Resolution: Contacted NOAA and recieved e-mail of corrcet info. Once hard copy arrives to vessel the owner will submit to CG.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 August 2017 Resolved
Missing COD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 August 2017
Resolution: E-mailed copy to CG.
Construction/Loadline › Structures › Deck Plating
Issued 8 August 2017 Resolved
Make temp repairs to port side outboard 2 ft from transom. Deck is soft and has hole in it. Deck is to be cut out and repaired at next dry dock NLT Mar 2018.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 14 August 2017
Resolution: Made temp repairs in aft deck to ensure water is sealed from entering hull. Vessel will need to repair aft deck after season and during dry dock.
Communications › Radio Communications › EPIRB
Issued 25 July 2016 Resolved
EPIRB battery expires in AUG.
Action required: 705 - Other - as specified
Due 30 August 2016
Resolved 31 August 2016
Resolution: A new EPIRB installed on vessel.
Construction/Loadline › Hull › Hull Plating
Issued 25 July 2016 Resolved
Leaking butt blocks STBD FWD IWO cabin.
Action required: 705 - Other - as specified
Due 30 October 2016
Resolved 15 June 2018
Resolution: Reviewed and closed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 July 2016 Resolved
Expired Fire ext. in the wheelhouse.
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: old ext. removed from wheel house and a new ext. was installed. All SAT.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 July 2016 Resolved
Expired Alcohol test strips
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Old strips removed and three new strips added with exp date of 2017.
Electrical › Electric Supply System (service) › Cable
Issued 25 July 2016 Resolved
Clean port engine to started battery cable connection
Action required: 705 - Other - as specified
Due 15 August 2016
Resolved 15 August 2016
Resolution: Cleaned starter cable to battery terminals.
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016 Resolved
Remove decayed wood IWO port frames 5-7 from fwd engine room blkhd to good wood (paint to prevent further decay)
Due 17 April 2016
Resolved 4 May 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 March 2016 Resolved
Secure overhead wires in stbd engine room fwd
Due 17 April 2016
Resolved 4 May 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 17 March 2016 Resolved
Provide support to STBD engine mount
Due 17 April 2016
Resolved 4 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016 Resolved
Remove angel hair in fwd engine room to good wood
Due 17 April 2016
Resolved 4 May 2016
Construction/Loadline › Hull › Transverse Frame
Issued 17 March 2016 Resolved
Remove decay IWP transverse frame near port exhaust to good wood & pain to prevent further damage
Due 17 April 2016
Resolved 4 May 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 27 July 2015 Resolved
Provide up to date alcohol swabs for alcohol testing.
Due 27 August 2015
Resolved 25 August 2015
Construction/Loadline › Structures › Manhole
Issued 27 July 2015 Resolved
repair broken hatch opening in MSD space overhead.
Due 27 August 2015
Resolved 25 August 2015
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 27 July 2015 Resolved
Renew all raw water hose clamps on port and stbd main diesel engines.
Due 27 August 2015
Resolved 25 August 2015
Engineering › Fuel Oil Service System › Piping
Issued 27 July 2015 Resolved
Re-affix fuel line to hull at the stbd fuel shut off valve, both brackets are broken.
Due 27 August 2015
Resolved 25 August 2015
Construction/Loadline › Penetrations › Gasket
Issued 27 July 2015 Resolved
Replace gasket on hatch to steering compartment.
Due 27 August 2015
Resolved 25 August 2015
Fire Fighting › Fire Bucket › Quantity
Issued 27 July 2015 Resolved
Provide 2 additional 2.5 gallon fire buckets with lanyards.
Due 27 August 2015
Resolved 25 August 2015
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 27 July 2015 Resolved
Determine and isolate cause of vibration from shaft arrangement. possible bent fluke on on wheel.
Due 27 August 2015
Resolved 25 August 2015
Construction/Loadline › Hull › Bottom Plating
Issued 26 March 2014 Resolved
Attending inspectors called out wasted fasteners IWO port (fwd) garboard.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified installation/renewal of wasted fasteners IWO port (fwd) garboard.
Engineering › Steering Gear System › Rudder
Issued 26 March 2014 Resolved
Attending inspectors called out worn packing IWO port & starboard rudders.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 4 April 2014
Resolution: Rudder post packing will be replaced at next scheduled dry-dock.
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2014 Resolved
Attending inspectors called out wasted fasteners IWO port forepeak @ FR#2 (x1), FR#3 (x2), & collision bulkhead (x2).
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2014 Resolved
Attending inspectors called for the removal of corrosion from fasteners IWO forepeak for further evaluation.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Superstructure
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renew of main deck IWO bunkroom.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Side Shell
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renew of port chine plank IWO bunkroom (decayed).
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 4 April 2014
Resolution: Attending inspectors verified removal and installation of port chine plank IWO bunkroom. The plank measured >5'' IAW NVIC 7-95.
Construction/Loadline › Hull › Girder
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renew of main deck beam/girder IWO bunkroom @ FR#1 & 2, portside.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renew of port side shell frames #2 & 3 IWO bunkroom.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Manhole
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renewal of engine room sill IWO bunkroom steps.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Stiffener
Issued 26 March 2014 Resolved
Attending inspector called for crop & renewal of port deck support (outboard) IWO engine room.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 March 2014 Resolved
Attending inspectors called out renewal of fastener hardware (nut & washer) IWO port engine room watertight bulkhead.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Engineering › Bilge Water Management System › Pump
Issued 26 March 2014 Resolved
Attending inspectors noted that bilge pump float switch (fwd engine room) was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2014 Resolved
Attending inspectors called for removal of corrosion from fasteners IWO side shell frames, port & starboard engine room for further evaluation.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Engineering › Fuel Oil Service System › Filter
Issued 26 March 2014 Resolved
Atttending inspectors called for removal of corrosion IWO port & starboard fuel filter/strainers (RACOR), located in E/R for further evaluation.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Engineering › Reduction Gearing/Clutches › Hose
Issued 26 March 2014 Resolved
Attending inspectors called for renewal of hydraulic oil lines IWO port & starboard reduction gears due to fittings being severely deterioated/wasted.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 26 March 2014 Resolved
Attending inspectors called for renewal of flexible exhaust couplings (from manifold - transom) due to dry-rot and deterioration of rubber.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Stiffener
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renewal of deck support stanchion IWO port aft (inboard) engine room.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Hull › Transverse Frame
Issued 26 March 2014 Resolved
Attending inspectors called for removal of corrosion IWO side shell frame fasteners, port & starboard lazarette for further evaluation.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Engineering › Reduction Gearing/Clutches › Gear
Issued 26 March 2014 Resolved
Attending inspector called for renewal of moutings for shift cables IWO port & starboard reduction gears.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 26 March 2014 Resolved
Attending inspector called for renewal of MSD discharge valve (seized).
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Superstructure
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renewal of decayed areas of cabin tops.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Superstructure
Issued 26 March 2014 Resolved
Attending inspectors called for crop & renewal of covering boards, port & starboard aft main deck.
Action required: 705 - Other - as specified
Due 2 May 2014
Resolved 22 May 2014
Construction/Loadline › Structures › Manhole
Issued 18 June 2012 Resolved
Renew work/deteriorated aft hatch IWO steering space.
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 29 July 2013
Resolution: Attending inspectors verified repairs made IWO aft hatch for lazarette.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 July 2008 Resolved
Provide replacement for condemned PFD passengers reduced by one.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Marine Charts
Issued 16 July 2008 Resolved
Provide updated Charts for area of operation
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › US Coast Pilot
Issued 16 July 2008 Resolved
Provide updated U.S. Coast Pilot or similar publication
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 July 2008 Resolved
Provide U.S. Coast Guard Light List
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 July 2008 Resolved
Provide tide tables and current tables for area of operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 July 2008
Resolved 29 July 2008
Navigation › Piloting/Steering › Marine Charts
Issued 8 June 2007 Resolved
Provide updated Charts and Pubs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2007
Resolved 26 September 2007
Construction/Loadline › Hull › Bottom Plating
Issued 15 March 2006 Resolved
Reseal butts and nail heads.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2006
Resolved 20 March 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 March 2006 Resolved
Slide shaft back approx 10-12" for examinations.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2006
Resolved 20 March 2006
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 March 2006 Resolved
Remove Sea Valves for exam
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 March 2006
Resolved 20 March 2006
Lifesaving › Buoyant Apparatus › Marking
Issued 15 March 2006 Resolved
Label buoyant apparatus and apply new retro tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 5 April 2006
Resolution: corrected
Engineering › Bilge Water Management System › Pump
Issued 15 March 2006 Resolved
Remove mud from forward bilge area.
Action required: 705 - Other - as specified
Due 20 March 2006
Resolved 5 April 2006
Engineering › Bilge Water Management System › Strainer
Issued 15 March 2006 Resolved
Remove debris from bilge piping pick ups
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 5 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2006 Resolved
Repair/replace battery terminals on batteries and bilge pump terminal block.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 5 April 2006
Personnel › Training › First Aid/CPR
Issued 17 August 2005 Resolved
rovide First aid training for 50% of the crew.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 August 2005
Resolved 23 August 2005
Lifesaving › Lifefloat › Painter
Issued 17 August 2005 Resolved
Replace Lifefloat seapainter with proper line as required by 46 CFR 180.175 (f)(3). Vessel not to sail until painter replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2005
Resolved 17 August 2005
Resolution: Painter replace prior to Inspector departure.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 August 2005 Resolved
Replace Retro on 5 adult PFD's. Passengers reduced by 5 until retro replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 August 2005
Resolved 23 August 2005
Lifesaving
Issued 19 April 2000 Resolved
REPLACE 6 ORANGE HAND HELD FLARES. VESSEL IS NOT TO OPERATE UNTIL PROVIDED.
Condition: Unknown
Due 19 April 2000
Resolved 24 April 2000
Lifesaving
Issued 19 April 2000 Resolved
REPAIR/REPLACE 4 ADULT PFD'S. VESSEL LIMITED TO 26 TOTAL PERSONS UNTIL PROVIDED.
Condition: Unknown
Due 30 April 2000
Resolved 24 April 2000
Fire Fighting
Issued 9 April 1998 Resolved
PROVIDE FIXED FIREFIGHTING AND DETECTION SYSTEM IN ENGINE ROOM AS REQUIRED BY 46 CFR 181.400, NO LATER THAN 11 MARCH 1999. SYSTEM INSTALLATION SHALL BE APPROVED BY THE COGNIZANT [name withheld] WITH PASSENGERS.
Condition: Unknown
Due 9 April 1998
Resolved 9 April 1998
Lifesaving
Issued 9 April 1998 Resolved
PRIOR TO OPERATING WITH PASSENGERS, RENEW EXPIRED HYDRO RELEASE FOR EPIRB.
Condition: Unknown
Due 9 April 1998
Resolved 13 April 1998
Lifesaving
Issued 9 April 1998 Resolved
CONDUCT SATISFACTORY FIRE/MAN OVERBOARD DRILLS IN PRESENCE OF CG INSP NO LATER THAN 14 APRIL 1998.
Condition: Unknown
Due 14 April 1998
Resolved 22 April 1998
Lifesaving
Issued 9 April 1998 Resolved
PRIOR TO OPERATING WITH PASSENGERS, REPAIR/REPLACE RING BUOY.
Condition: Unknown
Due 9 April 1998
Resolved 13 April 1998
Lifesaving
Issued 9 April 1998 Resolved
PROVIDE FOUR (4) ADULT TYPE I PFD'S - UNTIL SUCH TIME, THE VESSEL IS LIMITED TO THE CARRIAGE OF 26 TOTAL PERSONS.
Condition: Unknown
Due 9 April 1998
Resolved 13 April 1998
Documentation
Issued 9 April 1998 Resolved
PROVIDE RECORDS OF LIFESAVING, FIREFIGHTING, CREW TRAINING AND DRILLS AS REQUIRED BY 46 CFR 185.520-524 AND 46 CFR 185.702, NO LATER THAN 07 APRIL 1998.
Condition: Unknown
Due 9 April 1998
Resolved 13 April 1998
Documentation
Issued 9 April 1998 Resolved
PROVIDE RECORD OF IMPLEMENTATION OF PASSENGER COUNT DATA PER 46 CFR 185.504NO LATER THAN 14APR98.
Condition: Unknown
Due 9 April 1998
Resolved 13 April 1998
Construction/Loadline
Issued 29 October 1997 Resolved
CROP AND RENEW AFFECTED PORTION OF PORT BULWARK TOP, WHERE FOREDECK MEETS GUNWHALE.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Lifesaving
Issued 20 March 1997 Resolved
STENCIL OARS FOR BUOYANT APPARATUS WITH VESSEL'S NAME NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Engineering
Issued 20 March 1997 Resolved
INSTALL BELT GUARD ON PORT MAIN ENGINE NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Construction/Loadline
Issued 20 March 1997 Resolved
MAKE FORWARD HATCH COVER WATERTIGHT NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Electrical
Issued 20 March 1997 Resolved
RESECURE WIRING, WHERE HANGING IN ENGINE ROOM, NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Electrical
Issued 20 March 1997 Resolved
INSTALL FIRE PROOF COVERS OVER ENGINE ROOM ELECTRICAL POWER PANEL NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Engineering
Issued 20 March 1997 Resolved
RENEW BAND ON STBD EXHAUST AT TRANSOM WHERE WASTED, NO LATER THAN 20 APRIL 1997.
Condition: Unknown
Due 20 April 1997
Resolved 28 April 1997
Electrical
Issued 15 September 1995 Resolved
VSL'S S/S BATTERY BOX NEEDS REPLACING.
Condition: Unknown
Due 15 September 1995
Resolved 15 September 1995
Engineering
Issued 3 April 1995 Resolved
REPLACE WORN FUEL HOSE ON STARBOARD MAIN ENGINE IAW 46 CFR 182.20-409(ii)
Condition: Unknown
Due 14 April 1995
Resolved 5 May 1995
Accommodation/Occupational Safety
Issued 3 April 1995 Resolved
PROVIDE VENT AND FLAME SCREEN FOR MSD HOLDING TANK.
Condition: Unknown
Due 14 April 1995
Resolved 5 May 1995
Navigation
Issued 3 April 1995 Resolved
PROVIDE BOTH SIDE LIGHTS IAW COLREGS.
Condition: Unknown
Due 14 April 1995
Resolved 5 May 1995
Engineering
Issued 14 April 1992 Resolved
REPAIR EXHAUST COOLING WATER LEAK ON STBD ENGINE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
INSTALL FCC APPROVED 406MHZ EPIRB ON VESSEL PRIOR TO 31 AUGUST 1993.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992 Resolved
CORRECT LOOSE ENGINE MOUNT ON PORT MAIN ENGINE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992 Resolved
RENEW FLEXIBLE HOSE ON BOTH MAIN ENGINE FUEL FILTERS WITH CG TYPE A-1 HOSE AND APPROVED FITTINGS.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Navigation
Issued 6 August 1991 Resolved
MAKE HORN OPERABLE.
Condition: Unknown
Due 6 August 1991
Resolved 6 August 1991
Navigation
Issued 6 August 1991 Resolved
RENEW WORN STEERING RAM CONNECTOR PINS.
Condition: Unknown
Due 6 August 1991
Resolved 6 August 1991
Lifesaving
Issued 6 August 1991 Resolved
RENEW WATER LIGHT FOR RING BUOY.
Condition: Unknown
Due 6 August 1991
Resolved 6 August 1991
Lifesaving
Issued 6 August 1991 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 6 August 1991
Resolved 6 August 1991
Documentation
Issued 13 August 1990 Resolved
PROVIDE A CURRENT FCC MARINE RADIO OPERATORS PERMIT
Condition: Unknown
Due 13 August 1990
Resolved 13 August 1990
Navigation
Issued 24 August 1987 Resolved
REPLACE NAVIGATION LIGHTS WITH TYPE LISTED FOR VESSELS LESS THAN 20 METERS
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Fire Fighting
Issued 12 August 1986 Resolved
ALL CO2 FIRE EXTINGUISHERS ARE TO HYDROSTATICALLY TESTED.
Condition: Unknown
Due 12 August 1986
Resolved 12 August 1986
Navigation
Issued 4 September 1985 Resolved
PROVIDE COPY OF INLAND NAVIGATION RULES.
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Navigation
Issued 4 September 1985 Resolved
REPAIR MASTHEAD LIGHT
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985
Navigation
Issued 4 September 1985 Resolved
PROVIDE BELL IAW NAVIGATIONS RULES
Condition: Unknown
Due 4 September 1985
Resolved 4 September 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.