Documentation record
Registered dimensions (L × B × D)350.0 ft × 100.0 ft × 24.3 ft
Registered tonnagegross 5,387 / net 5,387
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 21 February 2025 · expires 28 February 2026
Service, as the file records itOffshore Supply Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5387 - Regulatory (Subpart C or D), Gross Ton
5387 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Lifesaving › Inflatable Liferafts › Float Free
Issued 22 March 2018
Resolved
Life rafts could not be launched manually. Retention poles corroded in place and slide rails bent, blocking free passage to water. Prove proper opeartion of all launching stations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2018
Resolved 3 April 2018
Resolution: Poles freed up and slide rails corrected/replaced.
Engineering › Bilge Water Management System › Piping
Issued 22 March 2018
Resolved
Bilge piping wasted in pump room, C/R to satisfaction of attend MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Section called out replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 March 2018
Resolved
C/R wasted frames and watertight bulkhead #S6, #S7, #S4 & #S5 ballast tanks called out by ABS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: ABS verified repairs and signed Loadline Certificate.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 March 2018
Resolved
Pull dead end wires in fwd winch room and replace missing blank port side breaker panel.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Blank replaced and desd end cable removed.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 March 2018
Resolved
Replace missing Pressure relief valve in fwd winch flat Port side.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: PRV installed.
Deck/Cargo › Ballast › Tank
Issued 22 March 2018
Resolved
Secure C-1 ballast tank manhole cover (missing bolts)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Manhole secured in place with bolts.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 22 March 2018
Resolved
2008 NOI and plan onboard and not being maintained. Submit NOI,obtain/maintain 2013 plan.
[name withheld], [phone withheld], [email withheld] MSU HOUMA, LA- personnel onboard did not know of a VGP, after some searching the 2008 plan was located.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 3 April 2018
Resolution: NOI located and put onboard and 2013 VGP plan placed onboard.
Construction/Loadline › Structures › Superstructure
Issued 22 March 2018
Resolved
Replace chain securing brackets for rails on center bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: Chain brackets welded in place.
Construction/Loadline › Structures › Door
Issued 22 March 2018
Resolved
Adjust WTD @ living quarters aft.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: WTD adjusted to seal.
Construction/Loadline › Structures › Door
Issued 22 March 2018
Resolved
Replace WTD gasket aft generator room (twisted)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Gasket replaced and door adjusted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 22 March 2018
Resolved
Tighten flex loop connections for CO2 systems (Paint Locker, Generator room and on crane)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Conection tightened.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 March 2018
Resolved
Replace missing fire extinguisher #25
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: extinguisher replaced.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 22 March 2018
Resolved
Pull dead end wire STBD Crane pedestal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Cable pulled.
Documentation › Markings/Placards › Garbage Placard
Issued 22 March 2018
Resolved
Update MARPOL V placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: Placard updated.
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2018
Resolved
Place wire splices in junction boxes in Forman’s cabin, huff locker and OJ locker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: J-boxes installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 March 2018
Resolved
Remove Temp wires used as permanent in state rooms, overloading circuits.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: Extention cords removed.
Engineering › Freshwater Generation System › Pump
Issued 22 March 2018
Resolved
Fix leaks in non vital systems in pump room and pump bilges. P/W and other systems pumps/piping leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: Leaks corrected and bilges pumped.
Construction/Loadline › Structures › Deck Plating
Issued 22 March 2018
Resolved
Replace wasted deck frames in pump room at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 3 April 2018
Resolution: Deck plate frame replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 March 2018
Resolved
Replace guards on A/C blowers, air handler Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 3 April 2018
Resolution: Guards replaced.
Lifesaving › Inflatable Liferafts › Markings
Issued 2 May 2017
Resolved
install life raft plcards at the operation station
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 2 May 2017
Resolved
replace life jackets retroreflective material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 May 2017
Resolved
distruibuation panel located in main cabin needs stencil
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017