MAURY USCG vessel records
← All vessels

ARAPAHO

Built
1980
Last inspected
26 March 2026
Documentation
Case Pending · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8757958
WDC4780
Flag
UNITED STATES
Maury page id
psix-52307

Documentation record

Registered dimensions (L × B × D)350.0 ft × 100.0 ft × 24.3 ft
Registered tonnagegross 5,387 / net 5,387
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTODD SHIPYARDS CORP · HOUSTON, TX, UNITED STATES · built 1980
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMOBILE, AL
Endorsements, as the file codes themcw_un
DocumentationCase Pending · issued 21 February 2025 · expires 28 February 2026
Service, as the file records itOffshore Supply Vessel
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5387 - Regulatory (Subpart C or D), Gross Ton
5387 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 7 inspections, each with its date, unit and type; 22 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 1 other vessel inspected with it; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MARS1 Towing Vessel · MISLE 178002 · 26 March 2026 · activity 8358249

Inspection history · 7

26 March 2026 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8358249
23 March 2026 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8331351
2 September 2025 Load Line/Change of Employment · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8229889
11 April 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6660687
22 March 2018 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6376484
22 March 2017 Hull Examination · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6109721
6 April 2016 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5849382

Deficiency record · 22

Lifesaving › Inflatable Liferafts › Float Free
Issued 22 March 2018 Resolved
Life rafts could not be launched manually. Retention poles corroded in place and slide rails bent, blocking free passage to water. Prove proper opeartion of all launching stations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2018
Resolved 3 April 2018
Resolution: Poles freed up and slide rails corrected/replaced.
Engineering › Bilge Water Management System › Piping
Issued 22 March 2018 Resolved
Bilge piping wasted in pump room, C/R to satisfaction of attend MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Section called out replaced.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 22 March 2018 Resolved
C/R wasted frames and watertight bulkhead #S6, #S7, #S4 & #S5 ballast tanks called out by ABS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: ABS verified repairs and signed Loadline Certificate.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 March 2018 Resolved
Pull dead end wires in fwd winch room and replace missing blank port side breaker panel.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Blank replaced and desd end cable removed.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 22 March 2018 Resolved
Replace missing Pressure relief valve in fwd winch flat Port side.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: PRV installed.
Deck/Cargo › Ballast › Tank
Issued 22 March 2018 Resolved
Secure C-1 ballast tank manhole cover (missing bolts)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Manhole secured in place with bolts.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 22 March 2018 Resolved
2008 NOI and plan onboard and not being maintained. Submit NOI,obtain/maintain 2013 plan. [name withheld], [phone withheld], [email withheld] MSU HOUMA, LA- personnel onboard did not know of a VGP, after some searching the 2008 plan was located.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 3 April 2018
Resolution: NOI located and put onboard and 2013 VGP plan placed onboard.
Construction/Loadline › Structures › Superstructure
Issued 22 March 2018 Resolved
Replace chain securing brackets for rails on center bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: Chain brackets welded in place.
Construction/Loadline › Structures › Door
Issued 22 March 2018 Resolved
Adjust WTD @ living quarters aft.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: WTD adjusted to seal.
Construction/Loadline › Structures › Door
Issued 22 March 2018 Resolved
Replace WTD gasket aft generator room (twisted)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Gasket replaced and door adjusted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 22 March 2018 Resolved
Tighten flex loop connections for CO2 systems (Paint Locker, Generator room and on crane)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Conection tightened.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 22 March 2018 Resolved
Replace missing fire extinguisher #25
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: extinguisher replaced.
Electrical › Electrical Distribution System (emergency) › Cable
Issued 22 March 2018 Resolved
Pull dead end wire STBD Crane pedestal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2018
Resolved 3 April 2018
Resolution: Cable pulled.
Documentation › Markings/Placards › Garbage Placard
Issued 22 March 2018 Resolved
Update MARPOL V placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: Placard updated.
Electrical › Electric Supply System (service) › Cable
Issued 22 March 2018 Resolved
Place wire splices in junction boxes in Forman’s cabin, huff locker and OJ locker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: J-boxes installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 March 2018 Resolved
Remove Temp wires used as permanent in state rooms, overloading circuits.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 3 April 2018
Resolution: Extention cords removed.
Engineering › Freshwater Generation System › Pump
Issued 22 March 2018 Resolved
Fix leaks in non vital systems in pump room and pump bilges. P/W and other systems pumps/piping leaking.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 March 2018
Resolved 3 April 2018
Resolution: Leaks corrected and bilges pumped.
Construction/Loadline › Structures › Deck Plating
Issued 22 March 2018 Resolved
Replace wasted deck frames in pump room at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2019
Resolved 3 April 2018
Resolution: Deck plate frame replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 March 2018 Resolved
Replace guards on A/C blowers, air handler Room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 3 April 2018
Resolution: Guards replaced.
Lifesaving › Inflatable Liferafts › Markings
Issued 2 May 2017 Resolved
install life raft plcards at the operation station
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 2 May 2017 Resolved
replace life jackets retroreflective material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 May 2017 Resolved
distruibuation panel located in main cabin needs stencil
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 2 May 2017

Recorded names · 1

TETRA ARAPAHO (2006–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.