FISH CITY PRIDE

FISH CITY PRIDE is a 1980 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1984, most recently in May 2025, along with 165 deficiencies — 1 with no resolution recorded —, 2 operational controls and 1 casualty investigation in 2008.

Records from 1984 to 2025. Most recent: inspection, 8 May 2025.

Built
1980
Last inspected
8 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WWDJ2144
Flag
UNITED STATES
367031770
Maury page id
psix-52313

Inspections, by type

…with no type recorded4
Years with a record 37 calendar years (1984–2025)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 8.3 ft
Registered tonnagegross 71 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPOMPANO BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Regulatory (Subpart C or D), Gross Ton
48 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2144MMSI 367031770 · active · compulsorily equipped · granted 23 September 2016, expires 23 September 2026
WYQ9289MMSI 367031770 · expired · compulsorily equipped · granted 8 April 2005, cancelled 1 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

8 May 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8130949
12 August 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7979324
26 January 2024 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7855988
16 January 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7849671
18 December 2023 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7852412
22 December 2022 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7611981
14 December 2021 Administrative Inspection · Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7368166
12 October 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7331079
27 September 2021 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7321377
21 December 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7114564
20 December 2019 DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6876896
10 December 2019 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6870755
21 December 2018 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6597124
12 January 2018 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6336841
4 January 2018 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6333898
23 September 2016 COI Inspection · Deficiency Check · DAPI Audit · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6007763
15 December 2015 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5782227
4 November 2015 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5780324
19 December 2011 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4211946
22 September 2011 COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4149168
1 December 2010 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3901774
8 December 2009 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3646748
20 November 2008 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3363133
14 February 2008 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3154537
10 October 2007 Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3075742
21 September 2006 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2782293
21 September 2005 Deficiency Check · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2498237
10 September 2005 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2488683
9 September 2004 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2190054
29 September 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1916826
15 September 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1905391
13 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1816417
5 September 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1671164
27 September 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1074278
18 September 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1422124
4 September 2001 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420578
19 September 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376319
28 September 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1369361
24 September 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1450348
11 September 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 799359
10 October 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112392
16 September 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1419825
27 September 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1142321
18 September 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1270037
13 September 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955426
12 January 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183433
11 September 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1185581
21 January 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163167
13 January 1994 Hull Examination · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1162315
17 September 1992 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 962556
30 September 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245177
18 September 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1244044
5 September 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940677
5 September 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245467
10 September 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 929918
29 June 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1222725
18 September 1989 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1219214
4 October 1988 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1198711
13 September 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1040261
29 October 1987 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1332224
28 September 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1313792
20 March 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1018577
6 October 1986 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1316965
15 October 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1294322
5 November 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1284445

Deficiency record · 165

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 May 2025 No resolution recorded
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel has not undergone an annual inspection within required timeline. Provide Sector Miami with a CG-3752 for a new COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 12 August 2024 Resolved
No vessel which is required by § 67.7 to be documented may engage in unlimited coastwise trade or the fisheries without being documented in accordance with the requirements of this part.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2024
Resolution: Vessel provided evidence of renewed COD. COD to expire on August 31, 2025.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 January 2024 Resolved
No person may use a vessel to which this part applies unless: (1) It has a number issued on a certificate of number by the issuing authority in the State of principal operation. Vessel owner could not produce a non-expired Florida state registration. Vessel must renew and carry documentation onboard. 33 CFR 173.15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided new state registration.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 January 2024 Resolved
Marine employers must ensure that data submitted by a consortium or other employer representative … is correct. Vessel does not have a copy of the most recent Management Information System (MIS) report onboard and thus cannot verity that their consortium submitted correctly. Vessel must obtain and verity MIS report. 46 CFR 16.500(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided the latest MIS report from 2022.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 January 2024 Resolved
A durable placard must be posted next to all radiotelephone installations with the emergency broadcast instructions and information, specific to the individual vessel. Vessel did not have a placard posted to radiotelephone installation with emergency broadcast instructions/information. Vessel must create and post placard. 46 CFR 184.506
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Emergency broadcast instructions posted at operating station.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 26 January 2024 Resolved
A ship, … , must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, … , stating the following: DISCHARGE OF OIL PROHIBITED... . Vessel is missing its oil discharge placard. Vessel must create/install in approprate spaces. 33 CFR 155.450(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Oil discharge placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts. Vessel did not have up-to-date charts on board. Vessel must update charts. 46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided current chart.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 January 2024 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is certified to carry 50 persons on board, but the vessel only had 48 onboard that were in good condition. Vessel must purchase 2 adult lifejackets. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided 2 new adult life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 January 2024 Resolved
The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyany type synthetic material having a minimum breaking strength of 1,350 pounds. MIs observed grab line break at the splice. Vessel must replace or re-splice grab line to attain minimum breaking strength. 46 CFR 160.050-3(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Lifebuoy provided with satisfactory spliced grab lines.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 26 January 2024 Resolved
The master or person in charge of a ship to which this section applies shall ensure that the ship is not operated unless a garbage management plan meeting paragraph (b) of this section is on the ship and that each person handling garbage follows the plan. Vessel does not have a garbage management plan onboard. Vessel must create and maintain a garbage management plan onboard at all times. 33 CFR 151.57(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided garbage management plan.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 26 January 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Vessel’s disposable hydrostatic release unit was past its expiration date. Vessel must purchase and install a new hydrostatic release unit. 46 CFR 185.740(b)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel provided new hydrostatic release unit for EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 January 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel’s starboard navigation light is inop. Vessel must replace bulb. In addition, vessel’s port and starboard navigation lights are open and exposed to weather. Make proper repairs. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel installed with new running board lights (port/starboard).
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 January 2024 Resolved
A vessel must carry either a first-aid-kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel operator presented a first aid kit that has expired. Provide a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Vessel purchased new first aid kit.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 January 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Found a hole in aft bulkhead of #2 Void. Make proper repairs. 46 CFR 179.320(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Bulkhead penetration sealed.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 26 January 2024 Resolved
All electrical installations shall be to the satisfactio of the OCMI. Found two rusted out junction box for light switches in #2 Void, located in the overhead position in way of entrance hatch. Replace corroded out junction boxes. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: 2 new junction boxes installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 26 January 2024 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crew. Plastic rail siding along portside midship was found with a crack. Make proper repairs to rail siding. 46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Rail siding fixed to rail post with screws.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 January 2024 Resolved
The visual bilge high level alarm for lazareet in way of operating station is extinguished. Replace bulb for visual bilge high level alarm. 46 CFR 177.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: New bulb installed for high bilge level alarm for lazarette.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 January 2024 Resolved
Insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation of vessel. Found in #2 Void two overhead transverse frames in way of hatch opening completely cracked through and or severely damaged by wood rot. Make proper repairs to two overhead transverse frames. 46 CFR177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: 2 new frames scarfed into existing frames.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 January 2024 Resolved
Insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation of vessel. Found in #2 Void along portside two overhead transverse frames with sever wood rot. Remove wood rot and make proper repairs to the transverse overhead frames. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Wood rot removed and sister frames installed as temporary repair. Vessel operator informed to check area on a regular basis for monitoring and maintenance.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 26 January 2024 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] engine room, found electrical wiring spliced improperly (spliced outside a junction box). Make proper electrical wire connections using a junction box in way of the sea strainer located on the port side of the engine room. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Observed new junction box installed.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 January 2024 Resolved
Insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation of vessel. Observed during steering gear test in lazarette, sea water leaking through in way of both port and starboard rudder posts. Make proper repairs to ensure watertight integrity. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Witnessed satisfactory steering gear test. No evidence of water intrusion from port and starboard rudder posts in lazarette.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 January 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, shall be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank shall be operable from outside the tank compartment. The emergency fuel shutoff valve for the service generator did not work as the securing band around the remote reach rod was loose, causing a free spin of the reach rod without closing the valve. Tighten down securing band and ensure emergency fuel shutoff valve works properly. 46 CFR 182.20-40(b)(3)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Satisfactorily tested emergency fuel shutoff valves.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 26 January 2024 Resolved
Insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation of vessel. Found multiple holes in side shell of lazarette, porside and a single hole in forward bulkhead, portside in lazarette. Make proper repairs to ensure compartment is watertight. 46 CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Hole in forward bulkhead made watertight.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 January 2024 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Did not find markings for remote fuel shutoffs. Make proper markings for remote fuel shutoffs. 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Marking for fuel shutoff valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 January 2024 Resolved
Rigid non-metallic materials are acceptable for use in bilge. Found non-metallic hose in bilge piping and pin hole in the metal bilge piping within engine room. Replace non-metallic hose with rigid non-metallic hose and make proper repairs to pin hole leak in the metal bilge piping. 46 CFR 182.40-5
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Section of bilge pipe replaced new piping.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 January 2024 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.46CFR176.502 / 701 c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2024
Resolution: Annual inspection completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 December 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Seal port and starboard rubber post leaks. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2022
Resolution: Attended for def check.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 December 2022 Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. High water alarms for the forward and aft compartments were inoperable. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2022
Resolution: Attended vessel for def check.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 December 2022 Resolved
Propulsion machinery shall be suitable in type and design for the propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. Repair port engine alternator and tighten belt. 46 CFR 182.05-1
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 January 2023
Resolution: Attended vessel, alternator was repaired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 December 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Cap unused through-hull valves. Seal bulkhead penetrations. 46 CFR 177.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2022
Resolution: Attended vessel for def check.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 December 2022 Resolved
The general construction of a vessel must be such as to minimize fire hazards insofar as reasonable and practicable. Clean engine room bilges and remove excess oil which represents a fire hazard. 46 CFR 177.405
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 December 2022
Resolution: Attended vsl for def check.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 December 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Tighten starboard shaft seal packing. 46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2022
Resolution: Attended vsl for def check.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 December 2022 Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. In addition, there shall be provided a number of approved life preservers suitable for children up to 10% of the total persons carried. Replace 06 adult lifejackets and 03 child life-jackets. 46 CFR 180.25-5
Action required: 705 - Other - as specified
Resolved 23 December 2022
Resolution: Attended vessel, new lifejackets purchased and onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 December 2022 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Replace missing railing bolts and seal to ensure weather-tightness. Make proper repairs to missing starboard forward cleat. 46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2023
Resolution: Attended vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 December 2022 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. Remount bilge high water alarms in all spaces to appropriate heights. 46 CFR 182.25-1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 December 2022
Resolution: Attended vsl for def check.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 December 2022 Resolved
All electrical installations shall be to the satisfaction of the Office in Charge, Marine Inspection. Add junction boxes to wiring where needed, clean wiring behind the bridge panel. 46 CFR 183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2023
Resolution: Attended vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 December 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards. Replace corroded battery connections. 46 CFR 183.210
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 January 2023
Resolution: Attended vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 October 2021 Resolved
Each bilge high level alarm must have a visual indicator at the operating station to indicate when any automatic bilge pump is operating. Aft compartment bilge alarm light isn't working properly. Repair/replace. 46 CFR 182.530(c)
Action required: 705 - Other - as specified
Due 18 October 2021
Resolved 15 October 2021
Resolution: visual and audible alarms now functioning properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 14 October 2021 Resolved
Moving belts on aux engines must have a guard around them to protect from slips,trips or falls that could result in serious injury if a person would to come in contact with the belts. Replace guard around aux engine in engine room. 46 CFR 182.310
Action required: 705 - Other - as specified
Due 18 October 2021
Resolved 15 October 2021
Resolution: Guard has been placed around belts on the generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 October 2021 Resolved
A number of child life jackets equal to 10% of total number of persons permitted must be supplied. Replace 01 missing child life jacket. 46 CFR 180.71(b)
Action required: 705 - Other - as specified
Due 18 October 2021
Resolved 15 October 2021
Resolution: childrens lifejackets have been replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 September 2021 Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in 176.500(b)(1) [annual inspection within 3 months before or after each anniversary date] and your Certificate of Inspection must be endorsed. Vessel is outside of three month window for Inspection and is not permitted to operate until annual inspection has been completed.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 September 2021
Resolved 14 October 2021
Resolution: Vessel sucessfully completed a renewal COI inspection
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 December 2020 Resolved
Each life ring buoy must be an approved type and constructed iaw 46CFR160.050. Replace retroreflective material on life ring. 46CFR180.30-1
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2020
Resolved 24 December 2020
Resolution: Reflective tape replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 December 2020 Resolved
Vessel must carry either a first aid kit approved under 46CFR160.041 or equivalent. 46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2020
Resolved 24 December 2020
Resolution: First aid kit purchased.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 December 2020 Resolved
Vessel must be equipped with properly operating bilge pump iaw 46CFR182.520(a) Vessel at least 26ft of length must have visual and audible alarms. Demonstrate pump and alarms are working properly. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2020
Resolved 24 December 2020
Resolution: Pump and audible alarms operating properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 December 2020 Resolved
Diesel engine exhaust cooling shall be installed iaw 46CFR182.15-15. Replace generator exhaust cooling valve coupling. 46CFR182.20-15
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 December 2020
Resolved 24 December 2020
Resolution: Coupling replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 December 2019 Resolved
Vessel required 6 red flares and 6 orange flares. Vessel has only 8 flares onboard. 4 more flares required. 46CFR180.68(a)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: Vessel representative purchased and placed onboard new flares to meet the required number.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 December 2019 Resolved
Battery on EPIRB is expired. Replace battery for EPIRB. Vessel restricted to no more then 3 NM from shore. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2020
Resolved 20 December 2019
Resolution: Vessel representative replaced EPIRB battery.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 December 2018 Resolved
Provide 08 more flares, vessel only had 4 onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2018
Resolution: Owner provided all required flares.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 21 December 2018 Resolved
Make repairs where the deck and sideshell meet on the port bow.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 December 2018
Resolution: Owner repaired the damage to the deck/sideshell area.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 21 December 2018 Resolved
Provide current epirb registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 January 2020
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 24 January 2018 Resolved
Vessel did not have valid COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Vessel operator provided proof of application.
Lifesaving › Lifefloat › Serviceable
Issued 24 January 2018 Resolved
Life float requires vessel name, retroreflective tape and weak link.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Vessel operator provided proof that life float vessel name, retroreflective tape and weak link were in proper operating condition.
Communications › Radio Communications › EPIRB
Issued 24 January 2018 Resolved
Vessel's EPIRB hydrostatic release was expired.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 February 2018
Resolution: Vessel operator provided valid hydrostatic release.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 12 January 2018 Resolved
Vessel required to complete annual inspection prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2018
Resolution: Inspector conducted annual inspection.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 4 January 2018 Resolved
46 CFR 176.600: Vessel must undergo a drydock and internal structural exam prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 10 January 2018
Resolution: Completed Credit DD/ISE.
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2016 Resolved
Charts were found outdated. Provide updated charts. 46 CFR 400
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 27 September 2016
Resolution: New charts were provided onboard.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 September 2016 Resolved
Provide most recent MIS report. 46 CFR 16.260
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 27 September 2016
Resolution: Owner provided copy of MIS report.
Lifesaving › Lifefloat › Serviceable
Issued 26 September 2016 Resolved
Found cracked/holed and wasted but in serviceable condition. Repair as original.
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 29 November 2016
Resolution: Repaired as orig.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 September 2016 Resolved
Multiple dead-end wires found under bridge console.
Due 10 October 2016
Resolved 11 October 2016
Resolution: All dead end wires were removed.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 September 2016 Resolved
Main generator cable found chaffed; repair and provide chaffing gear.
Due 3 October 2016
Resolved 11 October 2016
Resolution: Chaffing gear was installed on cable for main generator.
Engineering › Fuel Oil Service System › Valve
Issued 23 September 2016 Resolved
Generator fuel supply shut off valve found not working.
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 26 September 2016
Resolution: Repaired while onboard. Found working satisfactory.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 23 September 2016 Resolved
Hydraulic pump on port engine found leaking.
Due 21 October 2016
Resolved 29 November 2016
Resolution: Rebuilt pump and replaced seals as original.
Engineering › Freshwater System (jacketwater cooling) › Valve Manifold
Issued 23 September 2016 Resolved
Leak found on starboard main engine.
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 11 October 2016
Resolution: Renewed as orig.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 September 2016 Resolved
Distribution panels (3) in pilothouse found unapproved and in poor condition. Unable to properly close.
Action required: 705 - Other - as specified
Due 14 October 2016
Resolved 11 October 2016
Resolution: Renewed as orig.
Construction/Loadline › Hull › Transverse Frame
Issued 23 September 2016 Resolved
Deck beam in forward compartment (third back on port side) found in early stages of rot. Prior to credit dry-dock (2017) provide repair proposal to this office.
Due 30 September 2017
Resolved 8 February 2018
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 December 2015 Resolved
provide updated COD.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 26 September 2016
Documentation › Certificates/Documents › FCC SSL
Issued 15 December 2015 Resolved
provide updated FCC station license.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 26 September 2016
Navigation › Piloting/Steering › Marine Charts
Issued 15 December 2015 Resolved
Provide updated chart.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 17 December 2015
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 December 2015 Resolved
Renew first aid kit.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 17 December 2015
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 15 December 2015 Resolved
Replace broken hose clamps on the PMDE.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 17 December 2015
Electrical › Electric Generation Source (service) › Conductor
Issued 15 December 2015 Resolved
Remove wire nuts from the SSDG.
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 17 December 2015
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 4 November 2015 Resolved
Replace both shaft cutlass bearings.
Action required: 705 - Other - as specified
Resolved 12 November 2015
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 November 2015 Resolved
Repair/mount the port side railings.
Action required: 705 - Other - as specified
Resolved 14 October 2016
Engineering › Fuel Oil Service System › Valve
Issued 4 November 2015 Resolved
Repair/replace all emergency fuel shutoffs.
Action required: 705 - Other - as specified
Resolved 12 November 2015
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 November 2015 Resolved
Replace stbd pilothouse window.
Action required: 705 - Other - as specified
Resolved 12 November 2015
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 1 December 2010 Resolved
Replace wasted bridge distribution panel covers.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Communications › Radio Communications › EPIRB
Issued 1 December 2010 Resolved
Replace EPIRB antenna prior to operation more than 3miles from shore.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Lifesaving › Lifefloat › Lifeline
Issued 1 December 2010 Resolved
Prior to carriage past 3miles from shore, properly service life floats (wasted grab lines, painter attachment fabric loops, 4ft oars) IAW mfg instructions.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Engineering › Bilge Water Management System › Piping
Issued 1 December 2010 Resolved
Replace bilge piping with proper/approved pipe or rigid material IAW approved plans.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 December 2010 Resolved
Provide machinery guards for both MDE fly wheels.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 1 December 2010 Resolved
Provide cover and properly mark remote fire pull station, and provide op's instructions at CO2 cylinder.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Engineering › Bilge Water Management System › Piping
Issued 1 December 2010 Resolved
Provide metallic valve for drain through hole at transom.
Action required: 705 - Other - as specified
Due 15 December 2010
Resolved 21 December 2010
Construction/Loadline › Hull › Hull Plating
Issued 20 November 2008 Resolved
Make proper repair to fiberglass on port bow approximately 10'' from deck and approximately 4-5'' from bow.
Action required: 705 - Other - as specified
Due 19 December 2008
Resolved 20 December 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 November 2008 Resolved
Provide alcohol test kits onboard.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 November 2008 Resolved
Replace port and starboard running lights lens covers.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 November 2008 Resolved
Provide guards on lights exterior port side.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Engineering › Steering Gear System › Ram Seal
Issued 20 November 2008 Resolved
Repair/tighten port rudder post stuffing.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 20 November 2008 Resolved
Replace oil filter hose on starboard side of port engine with approved SAE J1942 hose.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 November 2008 Resolved
Repair exhaust lagging on starboard engine.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 November 2008 Resolved
Properly dead end wires on port engine in proper box.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Documentation › Markings/Placards › Warning Signs
Issued 20 November 2008 Resolved
Post emergency broadcast placard at operating station.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 November 2008 Resolved
Remove dead end wires under operating station or properly terminate in a box.
Action required: 705 - Other - as specified
Due 5 December 2008
Resolved 3 December 2008
Construction/Loadline › Hull › Hull Plating
Issued 20 November 2008 Resolved
Repair or replace rotted wood at: aft laz hatch box longitudinal on inboard side; eng room 1st & 2nd transverse under deck beam IWO fwd vents; eng room longitudinal & transverse (stbd and fwd side) under deck beam box for stack/exhaust pipes aft.
Action required: 705 - Other - as specified
Due 19 December 2008
Resolved 20 December 2008
Engineering › Bilge Water Management System › Pump
Issued 10 October 2007 Resolved
Properly mount all electrical submersible pumps.
Due 23 October 2007
Resolved 23 October 2007
Accommodation/Occupational Safety › Ventilation › General
Issued 10 October 2007 Resolved
Remove plastic vent hose throughout vessel and replace with corrugated metal.
Due 23 October 2007
Resolved 23 October 2007
Construction/Loadline › Hull › Longitudinal Frame
Issued 10 October 2007 Resolved
Crop and renew wasted beam in engine room by way of port forward ventilation. Remove surface rot from remaining beams and seal.
Due 23 October 2007
Resolved 23 October 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 October 2007 Resolved
Provide means to determine sewage tank 3/4 full.
Due 23 October 2007
Resolved 23 October 2007
Engineering › Steering Gear System › Rudder Stock
Issued 10 October 2007 Resolved
Provide rudder stop starboard rudder.
Due 23 October 2007
Resolved 23 October 2007
Navigation › Piloting/Steering › Marine Charts
Issued 10 October 2007 Resolved
Provide updated charts.
Due 30 October 2007
Resolved 5 November 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 October 2007 Resolved
Prove proper operation of stern light.
Due 30 October 2007
Resolved 23 October 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 10 October 2007 Resolved
Properly repair electrical plug at stern light.
Due 30 October 2007
Resolved 5 November 2007
Lifesaving › Embarkation Appliances/Stations › Designated Location
Issued 10 October 2007 Resolved
Provide platform for rescue platform.
Due 30 October 2007
Resolved 5 November 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 October 2007 Resolved
Update emergency procedures to reflect one deck hand.
Due 30 October 2007
Resolved 5 November 2007
Fire Fighting › Fire Bucket › Capacity
Issued 21 September 2006 Resolved
Provide 03 2.5 fire buckets onboard.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: Fax
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 21 September 2006 Resolved
Provide means to perform alcohol testing within two hours.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: fax
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 21 September 2006 Resolved
Perform Drug Testing Background checks.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 22 September 2006
Resolution: fax
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 September 2006 Resolved
Post EAP information.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: fax
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 September 2006 Resolved
Provide gross and tare weights on fixed co2 cylinders.
Action required: 705 - Other - as specified
Due 28 September 2006
Resolved 25 September 2006
Resolution: fax
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 21 September 2006 Resolved
Provide 53 Adult and 6 Child size life jackets onboard. Properly mark and stow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 September 2006
Resolved 22 September 2006
Resolution: Fax.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 September 2005 Resolved
Found both tanks severely corroded. The starboard tank was found to have numerous patches and repairs which appeared to have been on the tanks for several years. A puddy compound was scraped of a corner weld of the starboard tank and a large pit/hole in the weld allowed diesel fuel to pour into the bilge. A requirement was issued to remove both fuel tanks and replace with approved tanks.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2005
Engineering › Fuel Oil Service System › Filter
Issued 8 September 2005 Resolved
Repair oil leaks near starboard oil filter.
Due 7 October 2005
Resolved 13 October 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 September 2005 Resolved
Repair water leak near heat exchanger, located on the starboard side/raw water cooling area.
Due 7 October 2005
Resolved 13 October 2005
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 8 September 2005 Resolved
Replace all retroreflective tape on all lifejackets. (Adult/Child)
Condition: Unknown
Due 7 October 2005
Resolved 13 October 2005
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 8 September 2005 Resolved
Repair support bracket on fresh water tank, located up forward store.
Condition: Unknown
Due 7 October 2005
Resolved 13 October 2005
Navigation › Piloting/Steering › Marine Charts
Issued 8 September 2005 Resolved
Update all charts (applicable to route). Also, provide proof of corrections being completed.
Condition: Unknown
Due 7 October 2005
Resolved 13 October 2005
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 September 2004 Resolved
Properly repair bow bilge alarm indicator light.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2004
Resolved 10 September 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, Positive Displacement
Issued 9 September 2004 Resolved
Properly repair/replace hydrulic oil leak on starboard MDE transmission pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 September 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 September 2004 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Due 9 October 2004
Resolved 10 September 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 9 September 2004 Resolved
Provide updated copy of Nav. Rules.
Condition: Improper/Lack of Maintenance
Due 9 October 2004
Resolved 10 September 2004
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 September 2004 Resolved
Provide compass deviation table.
Condition: Placed in Improper Service
Due 9 October 2004
Resolved 13 October 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 September 2004 Resolved
Properly mark breakers in pilot house panel.
Condition: Placed in Improper Service
Due 9 October 2004
Resolved 13 October 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 9 September 2004 Resolved
Properly mount solinoid on prot MDE.
Condition: Improper/Lack of Maintenance
Due 9 October 2004
Resolved 10 September 2004
Engineering › Freshwater System (cylinder head cooling) › Piping
Issued 9 September 2004 Resolved
Double clamp jacket water system on both MDEs.
Condition: Placed in Improper Service
Due 9 October 2004
Resolved 10 September 2004
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 9 September 2004 Resolved
Properly repair broken ground wire in engine room.
Condition: Improper/Lack of Maintenance
Due 9 October 2004
Resolved 10 September 2004
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 September 2004 Resolved
Properly wire battery charger in engine room.
Condition: Placed in Improper Service
Due 9 October 2004
Resolved 10 September 2004
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 9 September 2004 Resolved
Provide proper cover for outlet box.
Condition: Improper/Lack of Maintenance
Due 9 October 2004
Resolved 10 September 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 September 2002 Resolved
Crew not able to demonstrate satisfactory recovery of MOB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2002
Resolution: Crew conducted extensive training on MOB procedures
Communications › Radio Communications
Issued 5 September 2002 Resolved
EPIRB battery is expired LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 22 September 2002
Electrical › Electric Generation Source (service)
Issued 5 September 2002 Resolved
Vessel's generator is not rated for 50deg ambient temperature LEGACY COMPONENT DESC: Generator
Due 10 October 2002
Resolved 30 September 2002
Fire Fighting › Ventilation Systems
Issued 5 September 2002 Resolved
E/R ventilation Closures require locking devices to remain in the closed position
Due 9 September 2002
Resolved 9 September 2002
Lifesaving
Issued 4 September 2001 Resolved
Prior to operation on the high-seas greater than 3 nautical miles, replace the EPIRB hydrostatic release._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Documentation
Issued 4 September 2001 Resolved
Provide a waste management plan and waste log._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Documentation
Issued 4 September 2001 Resolved
Provide a bridge log with all required entries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Construction/Loadline
Issued 4 September 2001 Resolved
Provide securing and retaining mechanism for forward hatch cover._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Provide access to the life floats._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Navigation
Issued 4 September 2001 Resolved
Provide a current Coast Pilot and Light List._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 4 September 2001 Resolved
Provide CPR cards for 50% of the crew._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Engineering
Issued 4 September 2001 Resolved
Provide and install belt guards on both main engines._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Lifesaving
Issued 19 September 2000 Resolved
Prior to 26SEP00, rewrite emergency instructions attesting to the use of your FFFE system with Masters permission.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Navigation
Issued 19 September 2000 Resolved
Prior to 26SEP00, provide publications and charts IAW 46CFR185.20-35.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Construction/Loadline
Issued 19 September 2000 Resolved
Prior to 26SEP00, label bilge high level alarm lights on bridge.
Condition: Unknown
Due 19 September 2000
Resolved 19 September 2000
Construction/Loadline
Issued 24 September 1999 Resolved
PROVIDE A COMPLETE HIGH BILGE LEVEL ALARM SYSTEM.
Condition: Unknown
Due 8 October 1999
Resolved 8 October 1999
Unknown
Issued 13 September 1996 Resolved
IMPROVE THE MAN OVERBOARD PROCEDURE. CONDUCT U/W TRAINING, PROVIDE BETTER GEAR.
Condition: Unknown
Due 13 September 1996
Resolved 13 September 1996
Unknown
Issued 13 September 1996 Resolved
COMPLY WITH 46 CFR, PART 16, DRUG TESTING PROGRAM.
Condition: Unknown
Due 20 September 1996
Resolved 18 September 1996
Lifesaving
Issued 13 January 1994 Resolved
RENEW REFLECTIVE TAPE ON ALL LIFEJACKETS. DEFICIENCY IS TO BE CLEARED PRIORTO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 30 January 1994
Resolved 21 January 1994
Electrical
Issued 13 January 1994 Resolved
PROVIDE MEANS TO MEASURE FREQUENCY OF INSTALLED SHIPS SERVICE GENERATOR AS PER 46 CFR 183.10-1(g).
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Documentation
Issued 13 January 1994 Resolved
PROVIDE PROOF OF CURRENT FCC STATION AND MARINE OPERATORS LISC.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 17 September 1992 Resolved
INSTALL FLOAT FREE LINK AND PAINTER OR PROVIDE A CONNECTING PAINTER BETWEENBOTH BUOYANT APPARATUS.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Construction/Loadline
Issued 17 September 1992 Resolved
REMOVE FUEL OIL/LUBE OIL FROM THE ENGINE COMPARTMENT BILGES.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Engineering
Issued 17 September 1992 Resolved
REPAIR THE STBD MAIN DIESEL ENGINE INBOARD MANIFOLD IN WAY OF THE FWD JACKET WATER LEAK. PORT MDE OIL PSI DRIVE GAUGE NOT OPERATING.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
MSD SYSTEM: REPAIR/REWEN THE TOILET BOWL FLANGE ON THE MENS TOILET, SECURE THE MSD HOLDING TANK LOCATED IN THE STEERING COMPARTMENT, PROVIDE A VENT FOR THE HOLDING TANK, AND REPAIR THE SEWAGE LEAK ON THE PORT LINE.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Electrical
Issued 17 September 1992 Resolved
SHIP SERVICE DIESEL GENERATOR: REPAIR THE SEAWATER COOLING WATER LINE AND LEAKING FUEL OIL INJECTOR/TUBING.
Condition: Unknown
Due 20 September 1992
Resolved 5 October 1992
Accommodation/Occupational Safety
Issued 17 September 1992 Resolved
REPAIR THE WOOD FACING AROUND THE MACHINERY ACCESS DOOR IN THE PASSENGER CABIN.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Construction/Loadline
Issued 17 September 1992 Resolved
SECURE ALL 24V BILGE PUMPS AND PROVE PROPER OPERATION OF ALL BILGE FLOAT ALARMS.
Condition: Unknown
Due 30 September 1992
Resolved 5 October 1992
Lifesaving
Issued 4 October 1988 Resolved
RENEW GRABLINE AROUND PERIMETER OF STARBOARD BUOYANT APPARATUS.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Lifesaving
Issued 4 October 1988 Resolved
PROVIDE USCG APPROVED WATERLIGHTS FOR EACH BUOYANT APPARATUS.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Engineering
Issued 4 October 1988 Resolved
PROVIDE DETAILS OF FUEL SYSTEM MODIFICATIONS FOR REVIEW AND APPROVAL. PROVIDE DETAILED INFORMATION ON HOSE TYPE AND MANUFACTURER.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Electrical
Issued 4 October 1988 Resolved
REMOVE UNUSED ELECTRICAL WIRING FROM LAZARETTE AND ENGINE COMPARTMENTS.
Condition: Unknown
Due 4 October 1988
Resolved 4 October 1988
Documentation
Issued 28 September 1987 Resolved
NO VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Documentation
Issued 28 September 1987 Resolved
NO OIL DISCHARGE PLACARD IN ENGINEROOM.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Accommodation/Occupational Safety
Issued 28 September 1987 Resolved
MSD INSTALLED BUT NOT PROPERLY CONNECTED. TOILETS STILL DISCHARGE OVER SIDE.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Lifesaving
Issued 28 September 1987 Resolved
INSTALL APPROVED FLOAT-FREE LINK ON LIFEFLOAT PAINTER.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Construction/Loadline
Issued 28 September 1987 Resolved
SKIN VALVE PORT SIDE OF ENGINEROOM, MIDSHIPS, AT THE TURN OF THE BILGE IS UNUSED BUT IS NOT PROPERLY PLUGGED OR CAPPED.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Electrical
Issued 28 September 1987 Resolved
REPLACE HOUSEHOLD FIXTURES IN ER OVERHEAD WITH APPROVED TYPE.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987
Construction/Loadline
Issued 28 September 1987 Resolved
MAIN DECK WATERTIGHT HATCHES DO NOT HAVE LANYARDS TO ATTACH COVER TO HULL.
Condition: Unknown
Due 28 September 1987
Resolved 28 September 1987

Casualty record · 1

14 February 2008Routine · role: Involved in a Marine Casualty · activity 3154537
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.