Records from 1981 to 2018. Most recent: inspection, 2 March 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 112
2 March 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6371400
14 April 2017
Administrative Inspection · Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6124425
9 July 2009
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3537275
30 October 2008
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3354294
14 August 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3298143
9 May 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3202531
26 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3087618
12 July 2007
Underwater Inspection in lieu of Drydock
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3026505
25 June 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974017
30 May 2007
Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2961346
11 April 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2905986
19 June 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2692606
11 August 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2459153
11 August 2005
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2459311
10 June 2005
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2367188
1 April 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2324791
5 August 2004
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2133284
16 June 2004
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2050767
16 September 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1882581
3 March 2003
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1751787
1 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1751208
22 September 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1678545
22 August 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073354
26 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075004
30 May 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428061
23 January 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057149
16 July 2000
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 821150
30 June 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1052339
2 June 2000
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1389115
15 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812939
8 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812900
29 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045808
12 November 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805703
1 September 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 783117
30 June 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1080239
8 June 1999
Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1467610
26 May 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801843
24 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798901
8 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791556
9 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803447
2 June 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402672
5 May 1998
Persons In Addition to Crew
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 790362
4 March 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470706
9 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774452
4 February 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1383763
24 December 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1439953
23 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117704
18 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109188
13 November 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 775020
5 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119193
7 October 1997
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1108041
4 August 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 782463
24 July 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 782607
23 June 1997
Hull Examination · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1439896
17 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1100115
10 February 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103796
18 November 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1177499
24 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828229
11 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952054
18 June 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1079317
5 June 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1421141
10 May 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082926
5 March 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886230
26 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873168
25 September 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881410
8 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 41885
28 June 1994
Deadweight Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1175361
22 June 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1330030
7 June 1994
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1410996
18 March 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268751
7 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248069
13 June 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035296
21 March 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236178
9 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211327
21 March 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919013
9 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344737
24 June 1989
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200419
7 June 1989
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340886
22 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038140
27 March 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041157
26 October 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 887622
30 September 1988
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1202312
14 September 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350249
29 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341287
20 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209946
11 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1351746
24 March 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995863
22 June 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006871
10 June 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1029735
18 September 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318087
21 August 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001344
20 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996816
20 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296583
16 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300842
5 May 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990747
4 April 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985203
4 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297500
17 July 1985
Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289805
27 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983891
6 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287562
19 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283562
18 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284527
4 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280503
4 April 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279911
1 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969446
11 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277609
9 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970084
8 February 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1273197
1 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272274
23 February 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279857
17 July 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969468
2 July 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966051
Construction/Loadline › Hull › Side Shell
Issued 16 June 2004
Resolved
Complete phase II of SEILOD inspection prior to next rig move. Submit report (including gauging reports) to PATMS.
Action required: 705 - Other - as specified
Resolved 3 September 2004
Resolution: Phase II of SEILOD completed.
Construction/Loadline
Issued 30 May 2001
Resolved
MAKE REPAIRS AS REQUIRED AND PROVE INTEGRITY OF ENTIRE BILGE SYSTEM.
Condition: Unknown
Due 7 June 2001
Resolved 8 August 2001
Accommodation/Occupational Safety
Issued 30 May 2001
Resolved
REPLACE COMPONENTS AS REQUIRED; MAKE REPAIRS AND PROVE PROPER OPERATION OF RED FOXX UNITS AS ORIGINALLY APPROVED. A LAB ANALYSIS OF EFFLUENT DISCHARGEWILL BE REQUIRED TO SATISFY THIS REQUIREMENT.
Condition: Unknown
Due 29 June 2001
Resolved 8 August 2001
Construction/Loadline
Issued 30 May 2001
Resolved
CROP AND RENEW WASTED BULKHEAD IN PIT ROOM; REPAIR OR REPLACE WATERTIGHT DOOR.
Condition: Unknown
Due 29 June 2001
Resolved 8 August 2001
Electrical
Issued 2 June 2000
Resolved
1. Prove proper operation of total rig shutdown system prior to next rig _x001C_ move.
Condition: Unknown
Due 15 July 2000
Resolved 19 June 2000
Engineering
Issued 8 June 1999
Resolved
Hydro test both fuel oil and oil based mud xfer hoses and label them IAW 33CFR 154.500.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Electrical
Issued 8 June 1999
Resolved
Replace all faulty spring loaded outlets in all hazardous class locations.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Construction/Loadline
Issued 8 June 1999
Resolved
Complete ABS Dry-Docking Survey and fax ABS report to OCMI once survey is complete.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Accommodation/Occupational Safety
Issued 8 June 1999
Resolved
Properly Connect Exaust for dryers to proper exaust fitting in laundry room.
Condition: Unknown
Due 8 June 1999
Resolved 8 June 1999
Lifesaving
Issued 2 June 1998
Resolved
SUBMIT FIRE CONTROL PLAN FOR REVISION IN ACCORDANCE WITH NEW INTERNATIONAL IMO STANDARD SYMBOLS.
Condition: Unknown
Due 2 June 1998
Resolved 2 June 1998
Lifesaving
Issued 2 June 1998
Resolved
CONDUCT OPERATIONAL TEST UNDER A LOAD OF 1.1 TIMES THE TOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLIMENT OF PERSONS & EQUIPMENT.
Condition: Unknown
Due 2 June 1998
Resolved 2 June 1998
Lifesaving
Issued 2 June 1998
Resolved
RENEW FUEL OIL SUPPLY AND RETURN LINES BETWEEN DAY TANK AND PRIME MOVERS (2) FOR DRILL FLOOR DRAW WORKS. ENSURE FLEX LINES DO NOT EXCEED 30".
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 2 June 1998
Resolved
PROVIDE 12 HAND HELD PARACHUTE FLARES.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Unknown
Issued 2 June 1998
Resolved
RENEW PAINT LOCKER VENT CLOSURE VALVE.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Lifesaving
Issued 2 June 1998
Resolved
IDENTIFY THOSE PERSONNEL PARTICIPATING IN TRAINING SESSION & DRILLS, LOG PROPERLY IN ACCORDANCE WITH 46 CFR 109.213 (h).
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 2 June 1998
Resolved
CONDUCT SATISFACTORY TEST OF RIG'S EMERGENCY TOTAL SHUT-DOWN, OPERATE EMERGENCY GENERATOR UNDER LOAD. PROPERLY LOG ABOVE TESTS.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Unknown
Issued 2 June 1998
Resolved
PROVIDE ABS/USCG APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Construction/Loadline
Issued 4 March 1998
Resolved
Complete repairs to leg to mat connections at wrapper plate where fractured, in accordance with repair proposal submitted by Global Divers. Repairs to be conducted to satisfaction of attending marine inspector or class surveyor. Submit report to [name withheld].
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Unknown
Issued 4 March 1998
Resolved
Place pressure relief valve on Global volume tank VT-6027 R/V.
Condition: Unknown
Due 6 March 1998
Resolved 9 March 1998
Lifesaving
Issued 4 March 1998
Resolved
Place retroreflective tape on both life capsules in accordance with_x001C_ NVIC 1-87.
Condition: Unknown
Due 4 March 1998
Resolved 4 March 1998
Unknown
Issued 4 March 1998
Resolved
Provide copies of volume tank and PVHO hyrostatic and annual inspection record, air hose pressure test, air certs for all compressors, and dive supervisor designation in writing.
Condition: Unknown
Due 6 March 1998
Resolved 9 March 1998
Construction/Loadline
Issued 24 December 1997
Resolved
MAKE REPAIRS TO BOW LEG-TO-MAT CONNECTION IN ACCORDANCE WITH APPROVED REPAIR PROCEDURE. CONDUCT REPAIRS TO SATISFACTION OF ATTENDING INSPECTOR PRIOR TO COMMENCING OPERATIONS AT NEXT LOCATION.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Construction/Loadline
Issued 24 December 1997
Resolved
MAKE REPAIRS TO LEG PINHOLES PER ABS REPORT (MC 7130), APPROVED CONSTRUCTION PORTFOLIO AND APPROVED WELDING PROCEDURE TO SATISFACTION OF ATTENDING INSPECTOR.
Condition: Unknown
Due 24 December 1997
Resolved 24 December 1997
Construction/Loadline
Issued 23 June 1997
Resolved
REPAIR WASTED SECTION OF STIFFENER IN MUD PUMP RM, STBD SIDE, FWD.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Lifesaving
Issued 23 June 1997
Resolved
REPLACE OR REPAIR WASTED PARTS OF EXHAUST VENTILATION FROM MUD PIT ROOM.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Unknown
Issued 23 June 1997
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION AIR RECEIVER ON DRILL FLOOR, CEMENT BULK TANKS #1, 3 AND BAROID TANK #2.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 23 June 1997
Resolved
PROPERLY LABEL ALL ALARMS, ALARM PULL STATIONS, AND HORNS THROUGHOUT RIG.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Engineering
Issued 23 June 1997
Resolved
PROVIDE FLAME SCREENS ON ALL OIL TANK VENTS.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Electrical
Issued 23 June 1997
Resolved
REMOVE, PROVE DEAD, OR END ALL DEAD ENDED WIRING IN COVERED JUNCTION BOXES,N AIR HANDLING UNIT SPACE AND INTERIOR REFRIGERATION SPACE.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Electrical
Issued 23 June 1997
Resolved
PROPERLY SECURE LOOSE WIRING BETWEEN DRILL FLOOR AND SHAKER AREA.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Electrical
Issued 23 June 1997
Resolved
REPAIR AND RELABEL, OR REPLACE DRILL FLOOR EXPLOSION PROOF BOX.
Condition: Unknown
Due 24 July 1997
Resolved 16 July 1997
Lifesaving
Issued 23 June 1997
Resolved
REPAIR THE FOLLOWING IN LIFEBOAT #2: AFT WINDOW CRACK; LEAK IN MANUAL HYDRAULIC START CYLINDER; 4 INCH CRACK IN OUTER SHELL AFT.
Condition: Unknown
Due 1 August 1997
Resolved 16 July 1997
Fire Fighting
Issued 23 June 1997
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR HALON ACTIVATION AT EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Electrical
Issued 23 June 1997
Resolved
PROPERLY LABEL ALL SWITCH BOARDS AND BREAKER BOXES.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Electrical
Issued 23 June 1997
Resolved
REPAIR ALL BROKEN/HANGING LIGHT FIXTURES THROUGHOUT RIG.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Construction/Loadline
Issued 23 June 1997
Resolved
REPAIR CRACKS IN LIMBER HOLES IN TANK #2P.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 23 June 1997
Resolved
REPLACE WASTED NUTS & BOLTS ON DOGS FOR HATCH TO SACK ROOM.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Construction/Loadline
Issued 23 June 1997
Resolved
REPAIR BROKEN WELD IN TANK #8 CENTERLINE.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Lifesaving
Issued 23 June 1997
Resolved
PROVIDE SUFFICIENT LENGTH OF ESCAPE LADDERS TO COME WITHIN AT LEAST 10 FEETOF WATERS EDGE.
Condition: Unknown
Due 8 July 1997
Resolved 16 July 1997
Lifesaving
Issued 23 June 1997
Resolved
PROVE PROPER OPERATION OF COMPASS FOR LIFEBOAT #1.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 23 June 1997
Resolved
PROVIDE COAST GUARD WITH GUAGING REPORT FOR BOTTOM PLATE IN TANK #4CL.
Condition: Unknown
Due 24 July 1997
Resolved 16 July 1997
Electrical
Issued 23 June 1997
Resolved
ROUTE EMERGENCY LIGHTING TO WATER EMBARKATION FOR LIFEBOATS SO AS TO BE SUPPLIED FROM THE EMERGENCY SOURCE OF LIGHTING AND POWER.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 23 June 1997
Resolved
PROVE PROPER OPERATION OF BATTERY "BATTLE" LANTERN TO AT STAIRWAY #7.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Fire Fighting
Issued 23 June 1997
Resolved
PROVE PROPER OPERATION OF SMOKE DETECTORS IN CHANGE/LAUNDRY ROOM AND PASSAGEWAY ADJACENT TO STAIRWAY #7.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Electrical
Issued 23 June 1997
Resolved
REPAIR BUNK LIGHT TO TOP BUNK, ROOM #32.
Condition: Unknown
Due 24 July 1997
Resolved 2 July 1997
Construction/Loadline
Issued 23 June 1997
Resolved
PROPERLY REPAIR DOUBLER IN BILGE PIPING, STBD SIDE BILGE PUMP AREA.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Accommodation/Occupational Safety
Issued 23 June 1997
Resolved
REPAIR WASTED SAFETY RAILING IN WAY OF LIFEBOAT #1 AND INBOARD CORNER OF CONTROL HOUSE.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Fire Fighting
Issued 23 June 1997
Resolved
REPLACE WASTED PARTS OF VALVES AT BOTH FIREMAIN SHORE CONNECTIONS.
Condition: Unknown
Due 24 July 1997
Resolved 3 July 1997
Construction/Loadline
Issued 23 June 1997
Resolved
PROVIDE COAST GUARD WITH ABS REPORT FOR CONDITION OF TANKS #2S, 8P, AND 7CL.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 23 June 1997
Resolved
PROVE OPERATION OF EMERGENCY GENERATOR LOW L/O SHUT DOWN.
Condition: Unknown
Due 24 July 1997
Resolved 16 July 1997
Fire Fighting
Issued 23 June 1997
Resolved
REPAIR WASTED FIREMAIN PIPING BY MAIN FIRE PUMP AND AT SALT WATER MANIFOLD.
Condition: Unknown
Due 1 July 1997
Resolved 2 July 1997
Documentation
Issued 7 June 1994
Resolved
SUBMIT FINAL STABILTY CALCULATIONS AND REVISED OPERATING MANUAL FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 7 June 1994
Resolved 7 June 1994
Navigation
Issued 21 March 1990
Resolved
PROPERLY MARK GENERAL ALARM BELL IN WIRE ROPE ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
RE-ADJUST GEN. ALARM IN SACK ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REPLACE OR REPAIR LOOSE COVER ON EXPLOSION PROOF SWITCH BOX NEXT TO LIGHT, JUST BENEATH RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REPAIR SHOWER EYE WASH STATION ON RIG FLOOR .
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
PROVIDE PROPER DOG ON #II BARITE TANK. BRASS HATCH TYPE DOGS NOT ACCEPT- ABLE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
MARK PROPERLY GENERAL ALARM HORN IN SHALE SHAKER.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
INSPECTION TO CONTINUE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
MARK PROPERLY GENERAL ALARM [name withheld]
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
REPAIR INOPERATIVE GENERAL ALARM BELL IN MSD ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
REPAIR ROTATING GENERAL ALARM LT. IN GENERATOR ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Documentation
Issued 21 March 1990
Resolved
SUBMIT TO [name withheld] SHOWING THE INSTALLATION OF THE EXTERIOR AIR COMPRESSOR "FLUFFING UNIT." INCLUDE RELIEF VALVE AND PIPING DETAILS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Documentation
Issued 21 March 1990
Resolved
SUBMIT PLANS TO [name withheld] ADDITIONAL INSTALLATION OF TWO BARITE TANKS, INCLUDE TANK DATA AND ANALYSIS TO DETERMINE THE LOADING OF DECK HAS NOT BEEN EXCEEDED.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
PROVIDE SELF CLOSING VALVES FOR FUEL OIL DAY TANKS ON RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYS FITTING ON EXPLOSION PROOF SWITCH BOX AFT RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REPLACE OR REPAIR EXPLOSION PROOF PLLUG BOX ABOVE WORK BENCH(TO THE RIGHT OF ITEM 23) RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYS FITTING ON EXPLOSION PROOF PLUG BOX ABOVE WORK BENCH/RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROPERLY SUPPRT ALL OVERHEAD TIE WRAPS NOT PERMITTED, SUPPORTING BANDS SHALL BE MIN. 5/8" DIA. NON-CORROSIVE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REPAIR LOSS VENT ALARM FOR SUPPLY FAN MUD PITS, ALARMS NOT ACTUATING ON RIGFLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROPERLY SUPPORT/SQUARE AWAY WIRING #2 LEG SPACE IN VICINITY OF TOTCO CONTROL PANEL.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Deck/Cargo
Issued 21 March 1990
Resolved
REPLACE SEVERELY DETERIORATED PERSONNEL BASKET FROM SERVICE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
PROPERLY MARK HALON ALARM IN MUD PUMP ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Documentation
Issued 21 March 1990
Resolved
CONDUCT AND LOG SEMI-ANNUAL LOAD TEST OF EMERGENCY BATTERIES.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Lifesaving
Issued 21 March 1990
Resolved
REWORK THE CAPSULE LIMIT SWITCH SO THAT THEY WORK EFFICIENTLY.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Lifesaving
Issued 21 March 1990
Resolved
FILL THE AIR BOTTLE IN THE STBD CAPSULE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
RESCINDED
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Fire Fighting
Issued 21 March 1990
Resolved
REPLACE FIRE EXTINGUISHER BRACKETS ON STATIONS 34 AND 35 ON RIG FLOOR.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROPERLY SUPPORT OVERHEAD WIRING RUN BETWEEN PIT LEVEL INDICATOR #1 AND LT.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYS FITTINGS ON ALL MUD PIT LEVEL INDICATORS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYS FITTINGS ON ALL GAS DETECTOR INDICATORS IN MUD PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
IDENTIFY AND MARK ALARMHORN STBD MUD PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Deck/Cargo
Issued 21 March 1990
Resolved
RE-ATTACH GUARD ON MUD MIXING PUMP,SHALE SHAKER.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
POUR EYS FITTING ON JUNCTION BOX LOCATED BY VENT SUPPLY FAN NEXT TO SHALE SHAKER.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
RE-ATTACH WIRE OUTER CONDUCTOR TO GLAND FITTING ON EXPLOSION PROOF PLUG BOXBY DESANDER UNIT.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
RE-MOUNT GAS DETECTOR IN SHALE SHAKER, REMOVE ALL SO WIRE FROM AREA (ARMORED OR [name withheld]).
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
POUR EYS FITTINGS, TIGHTEN ALL FITTINGS, RE-MOUNT EXPLOSION PROOF PLUG BOX IN PAINT LOCKER.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROVIDE PURGED CABINET IN ACCORDANCE WITH NFPA-496 OR REMOVE DRILL STRING ANGLE INDICATOR ON RIG FLOOR BY DRILLER'S CONSOLE. ENSURE ALL SONAT TELECO EQUIPMENT IS EXPLOSION PROOF OR MEETS THE PURGED REQUIREMENTS OF NFPA-496.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROVIDE AFFADAVIT FOR TEST OF GAS DETECTING EQUIPMENT. UNIT IS CURRENTLY SHOWING 8 PPM (NO DRILLING IS CURRENTLY BEING CONDUCTED).
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Documentation
Issued 21 March 1990
Resolved
RENEW THE INTERNATIONAL LOADLINE CERTIFICATE ENSURING THAT IT REFERENCES THE NEW STABILITY LETTER DATED 02JAN90.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PERFORM FULL TESTS ON GENERATORS INCLUDING OVERSPEED DEVICES, LOW LUBE SHUTON, HIGH TEMP ALARMS, AND REVERSE POWER RELAYS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
RESCINDED 05APR90.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
CLEAN OFF EXCESSIVE MUD FROM COOLING COWLING AND COOLING VANES ON MUD MIX- ING PUMP MOTORS/SHALE SHAKER.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROPERLY SUPPORT OVERHEAD RUN OF WIRING BETWEEN EXPLOSION PROOF SPEAKER HORN AND AND LIGHT ABOVE #1 MUD PIT AGITATOR MOTOR, IN MUD PIT.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYES ON PHONE BOX IN MUD PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
POUR EYS ON SPEAKER HORN IN MUD PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REPLACE SEVERELY WASTED EXPLOSION PROOF PLUG BOX IN PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Engineering
Issued 21 March 1990
Resolved
REMOVE PET COCKS PROVIDE FLAME SHIELDS FOR STBD 16V567 EMD MUD PUMP MOVER, RACOR FILTERS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REPAIR EMERGENCY LT IN FIRE PUMP ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
CORRECT PROBLEMS WITH MSD UNIT, HIGH LEVEL OF ODOR PRESENT IN SPACES.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REMOVE TAPE AND PROPERLY STENCIL GEN. ALARM BELL IN HALON 1301 ROOM.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Navigation
Issued 21 March 1990
Resolved
REPAIR ALL SOUND POWERED PHONE SYSTEMS/STATIONS ON RIG, SOME MISSING HAND SETS,SOME MISSING HANDSETS, SOME SELECTOR SWITCHES ETC.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REPLACE WASTED LADDER RUNGS ON #3 DRY BULK TANK.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Unknown
Issued 21 March 1990
Resolved
REMOVE PET COCKS, INSERT PLUGS ON PORT PRIME MOVER FOR MUD PUMP.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Deck/Cargo
Issued 21 March 1990
Resolved
RE-ATTACH GUARDS ON DRIVE SHAFTS FOR ALL 3 MUD PUMP AGITATOR PUMP MOTOR DRIVESHAFTS
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROVIDE PURGE AND LOSS OF PURGE ALARM FOR CANTILEVER BEAM SKID INDICATORS RIG FLOOR AFT.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REMOVE NON-EXPLOSION PROOF HORN CONTROL BOX LOCATED IN BACK OF DRILLERS CONSOLE(NOT UL, FM DRCSA)
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
PROVIDE LOSS OF PURGE INDICATOR FOR TOTCO T.V. MONITOR ON RIG FLOOR(DOES NOT MEET NFPA-496
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Fire Fighting
Issued 21 March 1990
Resolved
REPLACE PACKING ON PRIMARY FIRE PUMP.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Fire Fighting
Issued 21 March 1990
Resolved
REPAIR INOPERABLE VENTILATION FAN FOR SPACE ADJACENT TO MARINE SANITATION DEVICE.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REPLACE EMERGENCY SHUT OFF SWITCH.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Electrical
Issued 21 March 1990
Resolved
REMOVE OR REPAIR ALL DOOR OPEN INDICATOR LTS IN MUD PITS.
Condition: Unknown
Due 21 March 1990
Resolved 21 March 1990
Construction/Loadline
Issued 24 June 1989
Resolved
COMPLETE UNDERWATER VIDEO SWIM-BY EXAMINATION OF MAT BOTTOM SURFACE AND KEYWAY AREAS IN CONJUNCTION WITH NEXT RIG MOVE. PROVIDE DIVER'S SURVEY REPORT OF ALL UNDERWATER EXAMINATIONS.
Condition: Unknown
Due 24 June 1989
Resolved 24 June 1989
Construction/Loadline
Issued 7 June 1989
Resolved
MAKE PERMANENT REPAIRS TO TANKTOP DAMAGE IN SALT WATER DEEP TANK NO. 3/P TO SATISFACTION OF COGNIZANT [name withheld] TO BE COMPLETED PRIOR TO COMPLETION OF CREDIT HULL EXAMINATION. REPAIR PROPOSAL TO BE APPROVED BY COGNIZANT [name withheld] REPAIR.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Construction/Loadline
Issued 30 September 1988
Resolved
MAKE FOUR MUD PIT DUMP VALVES (SEA VALVES) AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Construction/Loadline
Issued 30 September 1988
Resolved
COMPLETE UNDERWATER EXAMINATION OF CRITICAL COLUMN-TO-MAT CONNECTIONS.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Construction/Loadline
Issued 30 September 1988
Resolved
COMPLETE UNDERWATER VIDEO EXAMINATION OF THE COLUMNS, MAT, SKIRT AND ANY OTHER AREAS DIRECTED BY THE ATTENDING INSPECTOR.
Condition: Unknown
Due 30 September 1988
Resolved 30 September 1988
Construction/Loadline
Issued 20 June 1988
Resolved
NOTIFY THIS OFFICE PRIOR TO CONDUCTING FIT UP AND SUBSEQUENT REPAIRS TO MODU LEG REFERENCED IN YOUR LETTER OF 10 JUNE 1988. 46CFR 107.275 (C)
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Construction/Loadline
Issued 24 March 1988
Resolved
REPLACE VENT ATOP PAINT LOCKER TO BE CLOSEABLE FOR ACTUATION OF FIXED FIRE FIGHTING SYSTEM AND ACCESSIBLE FROM THE DECK SURROUNDING THE LOCKER. (46 CFR 108.455)
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Lifesaving
Issued 24 March 1988
Resolved
MAKE LIFEBOAT NUMBER ONE AND TWO AVAILABLE FOR WEIGHT TEST. (46 CFR 107.239)
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Electrical
Issued 24 March 1988
Resolved
REPLACE CONTACT MAKER ON DRILL FLOOR WITH ONE SUITABLE FOR HARZARDOUS LOCATION. (46 CFR 108.170)
Condition: Unknown
Due 24 March 1988
Resolved 24 March 1988
Construction/Loadline
Issued 18 September 1986
Resolved
MAKE WATER TIGHT THE PORT AND STARBOARD QUICK ACTING WATER TIGHT HATCHES THAT LEAD TO THE MACHINERY SPACES. THE HATCHES ARE LOCATED ON MAIN DECK FORWARD ON THE PORT AND STARBOARD SIDE.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Construction/Loadline
Issued 18 September 1986
Resolved
REPAIR OR REPLACE 3 DOGS ON CARGO HATCH FOR THE MUD PIT ROOM.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Construction/Loadline
Issued 18 September 1986
Resolved
REPAIR OR REPLACE 3 DOGS ON CARGO HATCH FOR THE SACK ROOM.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Construction/Loadline
Issued 18 September 1986
Resolved
REPAIR OR REPLACE 1 DOG ON CARGO HATCH FOR PORT STORAGE ROOM.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Lifesaving
Issued 18 September 1986
Resolved
RENEW OR RELINE THE CUTLASS BEARING ON THE PORT SIDE LIFE BOAT.
Condition: Unknown
Due 18 September 1986
Resolved 18 September 1986
Electrical
Issued 4 April 1986
Resolved
PROVE PROPER OPERATION OF "LOSS OF VENTILATION" ALARMS ON DRILL FLOOR FOR ALL HELOW DECK SPACES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
PROVIDE ROTATING GENERAL ALARM LIGHT VISIBLE IN DRILL FLOOR AREA DUE EXCESIVE NOISE LEVELS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986
Resolved
PROVE OPERATION OF BOTH MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986
Resolved
PROVE OPERATION OF BOTH MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
RECHARGE AS NECESSARY THE PORT FIRE EXTINGUISHER IN #1 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
REFILL ALL AIR BOTTLES IN #1 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Navigation
Issued 4 April 1986
Resolved
RELAMP WITH APPROVED LAMPS BOTH SIDELIGHTS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
MAKE OPERABLE THE WATER TIGHT DOORS TO THE GALLEY AND THE PORT STERN JACKING ROOMAND REPAIR THE GASKET ON THE DECK HATCH TO THE MUD PITS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
REPLACE THE THROUGHT HULL FITTING FOR THE CO2 LINE, CAPSULE #2 RIGHTING SYSTEM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
REPAIR BROKEN LOCKER, STARBOARD SIDE AFT #2 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986
Resolved
PROVIDE HAND SIGNAL CHART IN THE PORT CRANE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
PROVIDE APPROVAL LETTER FOR THE FIRE CONTROL AND HAZARDOUS LOCATION PLANT LETTER DATED 6AUG82, GALVESTON TEXAS. IF THE APPROVAL LETTER COMMENTS DO NOT COVER THE DISCREPANCIES NOTE PER 46CFR108.171 RESUBMIT FOR APPROVAL.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
PROVIDE ON BOARD THE REQUIRED FIRST AID SUPPLIES PER 46CFR 108.707 REF 30CFR77.1707.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
PROFIDE ONBOARD SPARE SCBA BOTTLE FOR THE FIREMANS OUTFIT IN THE FIRE PUMP ROOM.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Lifesaving
Issued 4 April 1986
Resolved
REPLACE THE FORWARD LIMIT SWITCH ON THE #2 CAPSULE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
PROVE PROPER OPERATION OF "LOS OF AIR PURGE" ALARMS AT ADAIR UNITS ON DRILLFLOOR AT DRILLS CONSOLE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
PROVIDE NON-CONDUCTIVE (E.G.,RUBBER) MAT BEHIND MAIN SWITCHBOARD AND AUXILIARY (EMERGENCY) GENERATOR SWITCHBOARD. NON-CONDUCTIVE GRATINGS ARE AN ACCEPTABLE ALTERNATIVE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
PROPERLY ATTACH (HAND WIRE) STARTER CABLES TO AUXILIARY (EMERGENCY) GENERATOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
PROVE PROPER OPERATION OF HIGH TEMPERATURE ALARM ON #2 STARBOARD MAIN GENERATOR.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986
Resolved
PROVIDE RELIEF VALUES FOR #1 AND #III BULK AIR TANKS TO RELIEVE AT OR BELOW 45 PSIG.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
PROVE OPERATION OF PORT BILGE PUMP.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986
Resolved
REPAIR OR RENEW, AND PROVE PROPER OPERATION OF PRESSURE GAUGE ON SANITARY WATER TANK.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Engineering
Issued 4 April 1986
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION AND TEST RELIEF VALVES ON TWO MACHINERY SPACE AIR RECEIVERS AND ONE-DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Accommodation/Occupational Safety
Issued 4 April 1986
Resolved
CONDUCT AIR SAMPLE TEST ON THE DRILL FLOOR TEST FOR CARBON MONOXIDE DUE TO HEAVY CONCENTRATION OF EXHAUST SMOKE FROM THE DRAW WORKS ENGINES AND GENERATORS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Construction/Loadline
Issued 4 April 1986
Resolved
MAKE FORWARD MUD PIT DOOR SEL-CLOSING.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Deck/Cargo
Issued 4 April 1986
Resolved
PROVE AN FLEXIBLE FUEL HOSE IS RATED FOR "OIL SERVICE" AND HYDROSTATICALLY TEST SAME TO AT LEAST 225 PSIG IN ACCORDANCE WITH 33 CFR 156.170 AND 33 CFR 154. 500
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1986
Resolved
PROVE ADEQUATE EMERGENCY ILLUMINATION OF SWITCHBOARD AND MAIN GENERATOR SPACE. ADDITIONAL EMERGENCY LIGHTING MAY BE REQUIRED.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
PROVE PROPER OPERATION OF GENERAL ALARMS/FLASHING LIGHTS IN THE FOLLOWING AREAS: MUD PUMP ROOM, MSD)(SEWAGE TREATMENT) SPACE, MUD PIT AREA, MACHINE SHOP SPACE, STARBOARD AFT LEG HOUSE AND SHAKE HOUSE.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Fire Fighting
Issued 4 April 1986
Resolved
MAKE GENERAL ALARM CONTACT MAKE ON DRILL FLOOR OPERATIONAL. EXCESSIVE NOISE LEVELS.
Condition: Unknown
Due 4 April 1986
Resolved 4 April 1986
Electrical
Issued 4 April 1984
Resolved
REPAIR AND PRESENT FOR INSPECTION RESERVE POWER PROTECTION FOR BOTH MAIN GENERATORS. REF. 46 CFR 111.10.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Lifesaving
Issued 4 April 1984
Resolved
REPLACE EMBARKATION LADDER AT PORT CAPSULE. REF-46 CFR 108.525.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL J. STORM XI, DN617208.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Lifesaving
Issued 4 April 1984
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Fire Fighting
Issued 4 April 1984
Resolved
CLEAN AND FREEUP AL STICKING FIRE NOZZLE. REF. 46 CFR 108.419
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Deck/Cargo
Issued 4 April 1984
Resolved
PROVIDE PROPERLY SET RELIEF VALVES FOR ALL AIR RECEIVERS. REF. 46 CFR 54
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Fire Fighting
Issued 4 April 1984
Resolved
COMPLETED LABELING OF ALL FIRE STATIONS AND FIRE EXTINGUISHERS. REF 46 CFR 108.419.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Fire Fighting
Issued 4 April 1984
Resolved
REPLACE FLEXIBLE LOOP ON CO2 BOTTLE IN HALON SYSTEM. REF. 46 CFR 108.431.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Electrical
Issued 4 April 1984
Resolved
PROPERLY FILL ALL EYS FITTINGS AS NECESSARY IN ALL HAZARDOUS AREAS.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Navigation
Issued 4 April 1984
Resolved
REPAIR AND MAKE SERVICABLE WITH PROPER BULBS ALL NAVIGATION LIGHTS. REF. 46 CFR 111.75
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Navigation
Issued 4 April 1984
Resolved
CLEAN AND ALIGN ALL OBSTRUCTION LIGHTS. REF. 46 CFR 111
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
PROVIDE PROPER FLAME BOWLS FOR ALL RACOR TYPE FILTERS. REF. 46 CFR 56.50.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Construction/Loadline
Issued 11 March 1983
Resolved
ADJUST DOOR CLOSER ON PORT MUD PIT DOOR FOR PROPER OPERATION.
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Electrical
Issued 11 March 1983
Resolved
REPAIR STERN LIGHT RECEPTACLE TO CORRECT SHORT AND MAKE OPERATIONAL.
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Unknown
Issued 11 March 1983
Resolved
(REQUIREMENT 5 CONTINUED) (E) PIT ROOM TO PUMP ROOM.
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Electrical
Issued 11 March 1983
Resolved
PROVIDE DOCUMENTATION THAT EMPCO RED LIGHTS MEET REQUIREMENTS OF 72 COLREGSFOR AGROUND LIGHTS.
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Construction/Loadline
Issued 11 March 1983
Resolved
ADJUST FOLLOWING WT DOORS (A) PIT ROOM TO SACK ROOM (B) AIR COMPRESSOR ROOMTO SACK ROOM (C) GENERATOR ROOM TO PARTS ROOM (D) MSD TO PARTS ROOM
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Unknown
Issued 11 March 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, J. STORM XI DN617208.
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Lifesaving
Issued 11 March 1983
Resolved
MARK EMERGENCY FLASHING LIGHT IN GENERATOR ROOM "GENERAL ALARM, WHEN LIGHT FLASHES GO TO YOUR STATION".
Condition: Unknown
Due 11 March 1983
Resolved 11 March 1983
Lifesaving
Issued 9 February 1983
Resolved
PROVIDE 12 EACH HAND HELD FLARES FOR #1 AND #2 CAPSULES: 46 CFR 108.503.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Documentation
Issued 9 February 1983
Resolved
PROVIDE CONSTRUCTION PORTFOLIO: 46 CFR 107.305.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Unknown
Issued 9 February 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL J. STORM XI, DN617208.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Accommodation/Occupational Safety
Issued 9 February 1983
Resolved
REPAIR MACHINERY SPACE REMOTE VENTILATION SHUT DOWN: 46 CFR 111.80.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Construction/Loadline
Issued 9 February 1983
Resolved
ADJUST ALL WATERTIGHT DOORS FOR PROPER CLOSURE OPERATION.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Accommodation/Occupational Safety
Issued 9 February 1983
Resolved
REPAIR HOLE IN EXHAUST VENT DUCT FROM MUD PITS TO SACK ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Electrical
Issued 9 February 1983
Resolved
PROPERLY SUSPEND ALL WIRING IN MUD PUMP ROOM AND DRILL FLOOR USING METAL BANDING OR INSTALLED WIRE RUNS: 46 CFR 111.75.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Electrical
Issued 9 February 1983
Resolved
PROPERLY MOUNT REPAIR AND MARK GENERAL ALARM BELL IN PITS: 46 CFR 113.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Electrical
Issued 9 February 1983
Resolved
REMOVE OR MAKE SUITABLE FOR CLASS 1, DIVISON 2 LOCATION, ENGINE ALARM PANELON DRILL FLOOR: 46 CFR 111.92.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Electrical
Issued 9 February 1983
Resolved
REMOVE SPLICE FROM WIRE OVER DRAWWORKS AFT CATHEAD AND PROPERLY INSTALL NEWWIRE: 46 CFR 111.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Electrical
Issued 9 February 1983
Resolved
REMOVE OR MAKE SUITABLE FOR CLASS 1, DIVISION 2 LOCATION, GAS DETECTOR ON DRILL FLOOR: 46 CFR 111.92.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Accommodation/Occupational Safety
Issued 9 February 1983
Resolved
PROVIDE RELIEF VALVES FOR 3 P-TANK, NOT TO EXCEED 45 PSI AND FITTED WITH HAND RELIEVING GEAR: 46 CFR 54.15.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Lifesaving
Issued 9 February 1983
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Navigation
Issued 9 February 1983
Resolved
REPAIR NAVIGATION LIGHTS AND WIRING: 33 CFR 87.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Navigation
Issued 9 February 1983
Resolved
REPAIR OBSTRUCTION LIGHTS: 33 CFR 67.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Navigation
Issued 9 February 1983
Resolved
PROVIDE NOT UNDER COMMAND AND ANCHOR LIGHTS DAY SHAPES: 33 CFR 87.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Lifesaving
Issued 9 February 1983
Resolved
REPLACE FORWARD LIMIT SWITCH ON #1 CAPSULE: 46 CFR 108.507.
Condition: Unknown
Due 9 March 1983
Resolved 9 February 1983
Construction/Loadline
Issued 23 February 1982
Resolved
PROVIDE DOCUMENTATION OF A.B.S. SPECIAL UNDERWATER SURVEY.
Condition: Unknown
Due 23 February 1982
Resolved 23 February 1982
Fire Fighting
Issued 2 July 1981
Resolved
REMOUNT BRACKET FOR FIRE EXTINGUISHER NUMBER 15.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Fire Fighting
Issued 2 July 1981
Resolved
RENEW ALL PURPOSE NOZZLES TO FIRE HOSE STATIONS 14 AND 15.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Construction/Loadline
Issued 2 July 1981
Resolved
PROVIDE ALL WATERTIGHT DOORS WITH A SUITABLE DOGGING WRENCH.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
INSTALL PERSONNEL GUARDS IN WAY OF GENERATOR COMMUTATOR RINGS SO AS TO PREVENT PERSONNEL FROM INJURY OR ELECTRICAL SHOCK.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Fire Fighting
Issued 2 July 1981
Resolved
PROVIDE ONE ADDITIONAL LIFELINE FOR THE FIREMENS OUTFIT WHERE MISSING.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Fire Fighting
Issued 2 July 1981
Resolved
PROVIDE ONE PAIR OF ELECTRICALLY NON CONDUCTIVE GLOVES FOR EACH FIREMANS OUTFIT.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Unknown
Issued 2 July 1981
Resolved
INSTALL HEAT RESISTANT GLASS SIGHTGLASSES IN INDEPENDENT OIL TANKS.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Unknown
Issued 2 July 1981
Resolved
INSTALL SUITABLE SIGHTGLASS GAUGE GUARDS TO ALL INDEPENDENT OIL TANKS.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Unknown
Issued 2 July 1981
Resolved
PRIOR TO OPERATION OF THE CEMENTING UNIT PROVIDE PERSONNEL GUARDS IN WAY OFTHE EXHAUST MANIFOLDS AND RADIATORS.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Lifesaving
Issued 2 July 1981
Resolved
RENEW THE AFT WINDOW IN NUMBER TWO SURVIVAL CAPSULE.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Documentation
Issued 2 July 1981
Resolved
PROVIDE ONBOARD A VALID STABILITY LETTER.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Unknown
Issued 2 July 1981
Resolved
MAKE SUITABLE REPAIRS TO THE LOWER PIN CYLINDER ON THE FORWARD PORT QUARTER ON THE NUMBER ONE LEG TO PREVENT HYDRAULIC FUILD FROM LEAKING.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
PROVIDE COVERS TO ALL GAI-TRONICS PHONE BOXES WHERE PHONES ARE MISSING.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
PROPERLY INSTALL ELECTRIC RECEPTICAL IN THE #1 LEG ROOM ON THE AFT BULKHEAD
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
REMOUNT THE ELECTRIC RECEPTICAL ON THE AFT BULKHEAD OF THE QUARTERS ON THE MAIN DECK AT THE WATERCOOLER.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
PROPERLY RUN ELECTRICAL CABLE IN THE MUD PUMPROOM WHERE PENETRATING THE STOREROOM AND ACTIVE MUD PITS.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981
Electrical
Issued 2 July 1981
Resolved
PROPERLY RUN ELECTRICAL WELDING LEAD AND PORTABLE CABLES TO EMERGENCY GENERATOR ROOM OR REMOVE CABLES.
Condition: Unknown
Due 2 July 1981
Resolved 2 July 1981