Records from 1981 to 1999. Most recent: inspection, 23 December 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 52
23 December 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1046765
10 August 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 796304
5 March 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1441349
8 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 149133
16 May 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1108309
15 April 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1100408
17 March 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460939
24 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 675146
18 October 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1360729
17 September 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1270284
8 August 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1087627
8 March 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078251
8 March 1996
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1377634
4 March 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 64388
4 March 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 118421
4 March 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 214355
24 March 1995
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466929
28 January 1994
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1163088
5 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 683643
3 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 53706
7 October 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248071
24 July 1991
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944020
8 June 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1242618
12 February 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 229980
12 February 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911078
6 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1305631
24 July 1989
Deficiency Check · Damage Survey · Drydock Extension
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037124
10 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344821
23 May 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042128
16 June 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 890989
22 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331082
10 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022583
23 September 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012544
24 August 1987
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1001091
17 July 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1020449
29 June 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1320480
26 February 1987
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1311377
20 June 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 993522
25 February 1986
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 989553
30 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296691
27 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983897
26 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981628
25 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287955
21 February 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1289543
8 June 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280367
27 June 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968479
16 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274471
13 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967422
13 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275813
10 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281607
25 January 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967374
10 December 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277520
Lifesaving
Issued 5 March 1998
Resolved
PROPERLY REPAIR ALL DAMAGE TO BOTH LIFEBOATS AND PROVIDE ALL REQUIRED EQUIPMENT ON BOARD SAME.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Lifesaving
Issued 5 March 1998
Resolved
PROPERLY INSTALL AND PROVE PROPER OPERATION OF MUD PIT ROOM LOSS OF VENTILATION ALARM.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Construction/Loadline
Issued 5 March 1998
Resolved
PROVE PROPER OPERATION OF BOTH BILGE PUMPS.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Engineering
Issued 5 March 1998
Resolved
PROVE PROPER OPERATION OF BOTH EMD MUD PUMP ENGINES, SHIP SERVICE GENERATORS AND STAND-Y GENERATOR, AND ALL ALARMS AND SHUTDOWNS.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Navigation
Issued 5 March 1998
Resolved
INSTALL A PROPER NAVIGATIONAL LIGHT (PORT SIDE) TO COMPLY WITH THE COLREGS.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 5 March 1998
Resolved
PROVE PROPER OPERATION OF THE MSD SYSTEM.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Engineering
Issued 5 March 1998
Resolved
INSTALL PROPER APPROVED FUEL OIL FILTERS ON ALL ICE'S (INTERNAL COMBUSTION ENGINES).
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Accommodation/Occupational Safety
Issued 5 March 1998
Resolved
PROVE PROPER OPERATION OF ALL DOORS ON THE RIG, ESPECIALLY THE THREE (3) MUD PIT ROOM DOORS.
Condition: Unknown
Due 7 May 1998
Resolved 7 May 1998
Electrical
Issued 17 March 1997
Resolved
REMOUNT THE MOTOR CONTROL BOX FOR THE VENT MOTOR IN WAY OF THE STANDBY GENERATOR SPACE. REPAIRS TO BE MADE TO THE SATISFACTION. OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
REWIRE THE CONTROL CIRCUITS FOR THE STANDBY GENERATOR. REPAIRS TO BE COMPLETED AFTER ITEM #1 IS COMPLETED.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
EFFECT PERMANENT REPAIRS TO THE #1 SHIP SERVICE GENERATOR, CONDUCT OVERSPEED, LOW LUBE OIL, AND REMOTE SHUT DOWN TRIPS TO SAME. DEMONSTRATE PARALLEL OPERATION WITH THE #2 SHIP SERVICE GENERATOR. REPAIRS AND TESTS TO BE CONDUCTED TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
EFFECT PERMANENT REPAIRS TO THE AIR INTAKE SHUTDOWN IN BOTH SHIP SERVICE GENERATORS AND BOTH MUD PUMP PRIME MOVERS. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Fire Fighting
Issued 17 March 1997
Resolved
EFFECT PERMANENT REPAIRS TO THE #2 FIRE PUMP. DEMONSTRATE 50 POUNDS PITOT TUBE PRESSURE AT THE FIRE STATION ON THE FLIGHT DECK. REPAIRS AND TEST TO BE COMPLETED TO THE STATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Electrical
Issued 17 March 1997
Resolved
PROVIDE METAL CABLE HANGERS FOR ALL ELECTRICAL CICUITS LOADING FROM THE STANDBY GENERATOR SPACE. REPAIRS TO BE COMPLETED TO SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Construction/Loadline
Issued 17 March 1997
Resolved
EFFECT PERMANENT REPAIRS TO BOTH BILGE PUMPS. REPAIRS TO BE TO THE SATISFACTION OF ATTENDING MARINE INSPECTIOR.
Condition: Unknown
Due 17 March 1997
Resolved 17 March 1997
Documentation
Issued 18 October 1996
Resolved
The vessel sahll not put to sea until the stability and weight changes ahvebeen reviewed by the Marine Safety Center and found satisfactory.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Unknown
Issued 18 October 1996
Resolved
Make choke and kill piping ready for inspection and testing.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Accommodation/Occupational Safety
Issued 18 October 1996
Resolved
The new 28 man qtrs are not to be used until the issues of ventlation and stair way fire protection are resolved.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Documentation
Issued 18 October 1996
Resolved
Provide plans and data to Marine Safety Center on the installation of new accomodations and relocation of dry bulk tanks for their review of sturctural and stability issues. The new accomodations unit and relocated bulk tanks are not to used until MSC has completed their review.
Condition: Unknown
Due 7 November 1996
Resolved 24 February 1997
Unknown
Issued 18 October 1996
Resolved
Provide plans and welding procedures, welding certificates on new choke line and flare boom line.
Condition: Unknown
Due 26 February 1997
Resolved 26 February 1997
Lifesaving
Issued 18 October 1996
Resolved
Davit launched liferafts shall not be used prior to plan approval is received from USCG Maine Safety Center. Vessel to provide a copy of plan approval letter to cognizant OCMI before liferaft system authorized for use.
Condition: Unknown
Due 18 October 1996
Resolved 18 October 1996
Documentation
Issued 18 October 1996
Resolved
Provide an updated fire and safety equipment plan showing the new accomodations unit, new davit lauched liferafts and associated changes to cognizant OCMI for review.
Condition: Unknown
Due 1 November 1996
Resolved 24 February 1997
Documentation
Issued 18 October 1996
Resolved
Provide all necessary data, plans and details to Marine Safety Center for review and approval of changes made to vessel since last operations manual approval. The submittals are do be sufficient in scope and detail to allowthe MSC to approve a revised ops manual and new stability letter.
Condition: Unknown
Due 18 October 1996
Resolved 18 October 1996
Navigation
Issued 8 March 1996
Resolved
REPLACE AS NEEDED ALL CRACKED OBSTRUCTION LIGHT LENS.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Documentation
Issued 8 March 1996
Resolved
PROVIDE HULL GAUGING REPORT FOR 1996 ABS HULL SURVEY.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Navigation
Issued 8 March 1996
Resolved
COMPLETE REPAIRS TO STBD NAVIGATION LIGHT.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 8 March 1996
Resolved
BLANK OFF SPRINKLER SYSTEM FOR MAIN ENGINE EXHAUST VENTS.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 8 March 1996
Resolved
PRIOR TO DRILLING OPERATIONS, REPLACE LEAKING FIREMAIN JUMPER HOSE TO THE DRILL FLOOR.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Accommodation/Occupational Safety
Issued 8 March 1996
Resolved
REPAIR WASTED SUPPLY VENT TO MUD PIT ROOM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Electrical
Issued 8 March 1996
Resolved
REPAIR DOOR SWITCH TO EMERGENCY GENERATOR ROOM NEXT TO FIRE STATION #15.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 8 March 1996
Resolved
POST BLOCK DIAGRAM DETAILING USE OF HALON SYSTEM ON BULKHEAD ADJACENT TO HALON CYLINDERS.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Documentation
Issued 8 March 1996
Resolved
REVISE AND RESUBMIT FOT COAST GUARD APPROVAL FIRE CONTROL PLAN.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Documentation
Issued 8 March 1996
Resolved
PROVIDE COAST GUARD APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 8 March 1996
Resolved
PRIOR TO DRILLING OPERATIONS, PROVIDE PURGE ALARM ON SKID RAM INDICATOR PANEL.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 8 March 1996
Resolved
REPAIR/REPLACE BILGE PUMP IN COMPRESSOR ROOM BY FIRE STATION #36.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 8 March 1996
Resolved
PROVIDE A 4 FOOT APPLICATOR AT FIRE STATION #8.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 8 March 1996
Resolved
CLEAN OR REPLACE ALL WINDOWS IN LIFE CAPSULE #1.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Fire Fighting
Issued 8 March 1996
Resolved
REDIRECT NIPPLES AT FIRE STATIONS #3 AND #11 SO THAT THEY POINT DOWNWARD.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 8 March 1996
Resolved
ADJUST/REALIGN FOLLOWING SPRUNG WATERTIGHT DOORS: ALL ON MAINDECK AND STBDSIDE ENTRANCE TO PUMPROOM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 8 March 1996
Resolved
RENEW SEA CHEST SUCTION VALVE.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 8 March 1996
Resolved
LABEL BILGE MANIFOLD VALVES ON BOTH SIDES.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 8 March 1996
Resolved
PROVIDE DIRT CAPS FOR EYE WASH STATION IN MUD PIT ROOM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Lifesaving
Issued 8 March 1996
Resolved
PROVIDE A GENERAL ALARM RED BEACON IN MUD PIT ROOM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 8 March 1996
Resolved
ADJUST SELF-CLOSING DOOR BETWEEN MUD PIT ROOM AND SACK ROOM.
Condition: Unknown
Due 22 April 1996
Resolved 22 April 1996
Construction/Loadline
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL BILGE AND BALLAST PUMPS AND VALVES, REQUIRED PRIOR TO VESSEL BEING REACTIVATED AND LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Unknown
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF AIR COMPRESSOR UNITS, CONTROLS AND GUAGES TO BE COMPLETED AT REACTIVATION OF VESSEL AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Documentation
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE VALID LICENSES FOR REQUIRED MANNING LEVELS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
PERFORM ABANDONMENT LIFE BOAT DRILLS AT REACTIVATION. TO BE COMPLETED PRIORTO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Documentation
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE CURRENT CRANERECORD BOOK.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Documentation
Issued 24 March 1995
Resolved
AT ACTIVATION OT PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE CURRENT REFUSE LOG.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Documentation
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE CURRENT PERSON IN CHARGE LOG.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE CURRENT MAINTENANCE LOG FOR LIFE CAPSULES.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PROVIDE CURRENT SERVICING REPORT FOR FIREFIGHTING EQUIPMENT.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PERFORM OPERATIONAL TEST OF ALL DAVITS FOR LIFE CAPSULES.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, PERFORM OPERATIONAL TEST OF ALL LIFE CAPSULES.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, REPAIR WIRE MESH RETAINING CABLE ON PORT BOW OF HELO DECK.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, SUPPLY ALL LIFE CAPSULES WITH REQUIRED EQUIPMENT.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, REPAINT DRAFT MARKS AND LOADLINE.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH REQUIRED NUMBER OF RING BUOYS AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH REQUIRED NUMBER OF LIFE PRESERVERS AND ASSOCIATED GEAR.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH A LINE THROWING APPARATUS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH REQUIRED NUMBER OF FIREMAN'S OUTFITS AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Navigation
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH REQUIRED NUMBER OF DAY SHAPES.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Navigation
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH REQUIRED NUMBER OF SIGNALING DEVICES.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Lifesaving
Issued 24 March 1995
Resolved
AT ACTIVATION OR PRIOR TO LEAVING SABINE PASS, TEXAS, SUPPLY RIG WITH A LITTER USEABLE IN A HELO.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
PERFORM FIRE FIGHTING DRILLS WHEN VESSEL IS REACTIVATED. TO BE COMPLETED PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL FOUR MAIN GENERATORS: OVERSPEED TRIP, LOW LUBE OIL TRIP, REVERSE POWER RELAY TRIP, AND PARALLELING ALL FOUR GENERATOR UNITS. ITEMS TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
EMERGENCY GENERATOR ROOM POWER DISTRIBUTION BOARD MISSING GROUND DETECTION FAULT LIGHT. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 24 March 1995
Resolved
REPLACE VENT SCREEN TO PAINT LOCKER. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
DRILL FLOOR FUEL DAY TANKS MUST HAVE GUARDS INSTALLED AROUND SIGHT GLASS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
REPAIR WIRING HARNESS TO EMERGENCY GENERATOR AND REMOVE DEAD END WIRING ON HARNESS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
EXAMINE MAIN GENERATOR SWITCH BOARDS FOR PROPER OPERATION OF GUAGES, METERS, GROUND FAULT DETECTORS, INDICATORS. TO BE COMPLETED AT REACTIVATIONAND PRIOR TO LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
EXAMINE BATTERIES, CABLES, CONTAINERS AND CHARGER UNITS, AT REACTIVATION OFVESSEL AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL EMERGENCY LIGHTING AND ADEQUATE MARKINGS FOR "E" LIGHTS. REQUIRED TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF VENTILATION SHUTDOWNS, GENERATOR PRIME MOVER SHUTDOWNS,ESSENTIAL AND NON-ESSENTIAL EQUIPMENT SHUTDOWNS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Navigation
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL NAVIGATIONAL LIGHTING. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL FIRE PUMPS AND ASSOCIATED PIPING AND GUAGES. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF ALL FIRE HOSE STATIONS AND HYDRO TEST FIRE HOSES AS REQUIRED BY COGNIZANT MARINE INSPECTOR. TO BE COMPLETED AT REACTIVATION ANDPRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
OPERATIONAL TEST OF EMERGENCY GENERATOR LOW OIL PRESSURE TRIP AND OVERSPEEDTRIP SYSTEM. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS, TX.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Accommodation/Occupational Safety
Issued 24 March 1995
Resolved
REPAIR VENTILATION DUCTING IN WAY OF AIR COMPRESSOR ROOM. TO BE COMPLETED AT REACTIVATION AND LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Electrical
Issued 24 March 1995
Resolved
NO.1 EMD GENERATOR (PORT SIDE) MISSING PROTECTIVE GUARD AROUND ARMATURE ANDBRUSHES. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 24 March 1995
Resolved
REPAIR OPEN PENETRATIONS TO WATER TIGHT BULKHEAD TO PUMP ROOM (PORT SIDE).
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 24 March 1995
Resolved
REPAIR WATERTIGHT DOOR CLOSURE HANDLES IN WAY OF MUD PIT ROOM. TO BE COMPLETED AT REACTIVATION AND PRIOR TO LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Fire Fighting
Issued 24 March 1995
Resolved
REPAIR FROZEN NOZZLE HANDLE TO PORTABLE FIRE EXTINGUISHER AT STATION 21. TOBE COMPLETED AT REACTIVATION AND LEAVING SABINE PASS, TEXAS.
Condition: Unknown
Due 24 March 1995
Resolved 24 March 1995
Construction/Loadline
Issued 28 January 1994
Resolved
SUBMIT RESULTS OF UNDERWATER PORTION OF SEILOD EXAM TO [name withheld], TEXAS.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Documentation
Issued 28 January 1994
Resolved
SUBMIT FOR APPROVAL REVISIONS TO OPERATIONS MANUAL.
Condition: Unknown
Due 28 January 1994
Resolved 28 January 1994
Documentation
Issued 28 January 1994
Resolved
SUBMIT FOR APPROVAL CORRECTIONS TO FIRE CONTROL PLAN.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 8 June 1990
Resolved
REPAIR THE BENT LATTICE MEMBER IN THE SECTION BELLOW THE TOP SECTION ON THE LEFT SIDE OF THE STBD CRANE.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Lifesaving
Issued 8 June 1990
Resolved
PROVIDE TWO (2) ORANGE SMOKE FLARES FOR THE PORT LIGHT CAPSULE.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Navigation
Issued 8 June 1990
Resolved
CORRECT THE SEQUENCE OF THE OBSTRUCTION LIGHTS SO THAT THEY ALL FLASH SIMULTANEOUSLY.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990
Resolved
MOVE THE LOSS OF PURGE ALARM FOR THE DRILLER'S DATA TV MONITOR SO THAT IT IS IN THE VIEW OF THE DRILLER.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990
Resolved
REMOVE THE TYPE "SO" CABLE FROM THE LOGGER'S SHACK.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990
Resolved
PROVIDE A STROKE COUNTER IN PLACE OF THE SUNCO STROKE COUNTER SUITABLE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Fire Fighting
Issued 8 June 1990
Resolved
WIRE THE GENERATOR AND MUD PUMP ENGINES SHUTDOWNS INTO THE HALON FLOODING SYSTEM.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 24 July 1989
Resolved
PROVIDE A REPAIR PREPOSAL FOR THE DAMAGE TO THE PORT LEG AND CALCULATIONS SHOWING THE VARIBLE DECK LOAD HAS NOT BEEN AFFECTED BY THE DAMAGE.
Condition: Unknown
Due 24 July 1989
Resolved 24 July 1989
Unknown
Issued 23 May 1989
Resolved
REPLACE WIND SOCK FOR HELO DECK.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Unknown
Issued 23 May 1989
Resolved
CORRECT DURATION OF FOG HORN TO COMPLY WITH 33 CFR 167.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Lifesaving
Issued 23 May 1989
Resolved
CORRECT CABLE LENGTHS ON LIFEBOATS #1 AND #2 SO THEY ARE NOT DOUBLE WRAPPEDON DRUM.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Unknown
Issued 23 May 1989
Resolved
CLEAN CONTACTERS ON BOTH LIFEBOAT WIRCH CONTROLLERS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Unknown
Issued 23 May 1989
Resolved
CORRECT PURGE SYSTEM ON STROKE COUNTER ON DRILL FLOOR. MUST HAVE VISIBLE INDICATION OF LOSS OF PURGE OR AUDIBLE ALARM IAW NFPA 496. TYPE "Z" PURGE.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Electrical
Issued 23 May 1989
Resolved
CORRECT "E" LIGHT IN MUD PIT.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Documentation
Issued 23 May 1989
Resolved
PROVIDE DOCUMENTATION ON THE RIDING BELTS USED ON THE RIG AS BEING APPROVED AND MEETING ANSI 10.4.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Electrical
Issued 23 May 1989
Resolved
CLEAN AND/OR REPLACE EMERGENCY GENERATOR RADIATOR.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Construction/Loadline
Issued 24 August 1987
Resolved
MAKE UPPER HULL TANK INTERNALS READY FOR EXAM BY A COGNIZANT [name withheld] AS POSSIBLE.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Construction/Loadline
Issued 24 August 1987
Resolved
PROVIDE REPAIR PROPOSAL FOR DAMAGE TO THE PORT LEG AT THE 83' ELEVATION TO THE OUTBOARD PIN HOLE ON THE FORWARD AREA TO THE NEXT CG MARINE INSPECTION ZONE FOR APPROVAL AS SOON AS POSSIBLE.
Condition: Unknown
Due 24 August 1987
Resolved 24 August 1987
Electrical
Issued 29 June 1987
Resolved
CONDUCT TEST OF THE REVERSE CURRENT RELAY MECHANISM.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Navigation
Issued 29 June 1987
Resolved
REPLACE OR REPAIR STERNLIGHT FIXTURE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Lifesaving
Issued 29 June 1987
Resolved
HOLD FIRE AND ABANDON VESSEL DRILLS.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Deck/Cargo
Issued 29 June 1987
Resolved
HYDRO THE OIL TRANSFER HOSE FOR DIRTY L/O TRANSFER TO 1.5 X MAX HEAD PRESSURE EXPOSED.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Accommodation/Occupational Safety
Issued 29 June 1987
Resolved
MAKE READY FOR TEST ALL FIRE DAMPERS PER FIRE SAFETY AND CONTROL PLAN.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Electrical
Issued 29 June 1987
Resolved
CONDUCT TEST OF OVERSPEED TRIP MECHANISM, LOW LUBE OIL ALARM FOR NUMBER 2 SS GENERATOR.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Deck/Cargo
Issued 29 June 1987
Resolved
CONDUCT TEST OF THE RIG FLOOR AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Accommodation/Occupational Safety
Issued 29 June 1987
Resolved
INSTALL ASME APPROVED RELIEF VALVES FOR POTABLE WATER AND SANITATION WATER PRESSURE VESSELS.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Engineering
Issued 29 June 1987
Resolved
CLEAN OR RELABEL BOTH PORT AND STARBOARD BILGE MANIFOLD VALVES.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Fire Fighting
Issued 29 June 1987
Resolved
PROVIDE A LEGIBLE COPY OF THE FIRE SAFETY AND CONTROL PLAN.
Condition: Unknown
Due 29 June 1987
Resolved 29 June 1987
Construction/Loadline
Issued 30 July 1985
Resolved
REPAIR DOOR TO LIVING QUARTERS SO IT CLOSED PROPERLY REF. 46 CFR 108.114.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Electrical
Issued 30 July 1985
Resolved
REPAIR THE LOSS OF AIR PURGE IN THE MUD PIT REF. 46 CFR 108.170.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Electrical
Issued 30 July 1985
Resolved
RECHARGE EMPTY AIR BOTTLE IN NO.2 LIFEBOAT REF. 46 CFR 108.503.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Electrical
Issued 30 July 1985
Resolved
PROVIDE APPROVED LIGHT BULBS FOR RUNNING LIGHTS. REF 46 CFR 111.75-17.
Condition: Unknown
Due 30 July 1985
Resolved 30 July 1985
Construction/Loadline
Issued 21 February 1985
Resolved
CONDUCT UNDERWATER VIDEO INSPECTION OF THE MAT BOTTOM AND SKIRT AT THE NEXTRIG MOVE BUT NO LATER THAN 21MAR85.
Condition: Unknown
Due 21 February 1985
Resolved 21 February 1985
Construction/Loadline
Issued 21 February 1985
Resolved
MAKE MUD PIT DUMP VALES AVAILABLE FOR EXAMINATION AT THE NEXT RIG MOVE BUT NO LATER THAN 21MAR85.
Condition: Unknown
Due 21 February 1985
Resolved 21 February 1985
Navigation
Issued 10 June 1982
Resolved
PROVIDE NAVIGATIONAL DAY SHAPES TO CONFORM WITH 1972 COLREGS RULES 27 AND 34.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Fire Fighting
Issued 10 June 1982
Resolved
PROVIDE FOG APPLICATOR FOR FIRE STATION IN MUD PUMP ROOM.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Fire Fighting
Issued 10 June 1982
Resolved
REPLACE NOZZLES ON FIRE STATIONS AT PORT MAIN DECK AND RED FOX ROOM.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Lifesaving
Issued 10 June 1982
Resolved
REP./REPL. THE FOLLOWING LIFE RINGS: (A) P' SIDE MAIN DK. (B) STBD SIDE FWDMAIN DECK (C) AFT MAIN DECK & REPLACE WATERTIGHT ON AFTER STBD RING.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Navigation
Issued 10 June 1982
Resolved
PROVIDE ONE (1) ALL AROUND WHITE ANCHOR LIGHT & TWO ALL AROUND RED AGROUND LIGHTS. PROVIDE NAV. LIGHTS TO CONFIRM WITH 1972 COLREGS, RULES 27A & 30A.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Navigation
Issued 10 June 1982
Resolved
REPLACE/REPAIR LAMP CHANGER ON THE STARBOARD FORWARD AND PORT AFT. OBSTRUCTION LIGHTS. REPLACE BURNT OUT LAMPS IN FWD STBD OBSTRUCTION LIGHT.
Condition: Unknown
Due 10 June 1982
Resolved 10 June 1982
Unknown
Issued 25 January 1982
Resolved
RE-PIPE AIR INTAKE AND EXHAUST PIPING FROM LISTER DIESEL ON DRILL FLOOR INTAKE AND EXHAUST PIPING TO BE RE-PIPED OUTSIDE OF CLASSIFIED AREA.
Condition: Unknown
Due 25 January 1982
Resolved 25 January 1982