Records from 1982 to 2012. Most recent: casualty investigation, 17 December 2012.
Inspection history · 127
20 March 2009
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3445025
15 October 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3345120
17 June 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3231930
12 April 2007
Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2906781
26 August 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2760183
29 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2739971
24 May 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2658039
28 April 2006
COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2637840
25 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2645765
18 May 2005
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2426923
19 April 2005
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2337470
1 June 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2084703
5 April 2004
Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2037859
23 July 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1859603
1 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1751233
30 October 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1698598
1 May 2002
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1667941
17 April 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607194
8 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073267
26 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075007
13 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064140
25 April 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431022
3 February 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1058611
31 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 36802
28 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 63006
11 August 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821575
9 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 818898
12 May 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465561
24 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816978
16 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809354
7 September 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 782041
5 August 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117146
24 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798902
19 May 1999
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469900
10 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128875
1 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806529
14 October 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67976
25 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131866
17 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130751
21 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 795320
14 July 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375425
1 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124020
5 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118574
30 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 54312
29 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 6827
21 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115211
7 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114372
1 July 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1115966
27 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 79775
14 May 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455481
23 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099518
26 December 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 3116
26 December 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165044
23 October 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1160616
14 August 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095461
19 June 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214090
19 June 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467932
24 May 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466949
5 May 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 165701
12 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764738
27 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193980
27 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194007
27 March 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765183
7 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184863
25 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184828
19 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185049
22 August 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186978
19 June 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189140
6 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 654210
22 May 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461641
17 May 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 27667
4 April 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148439
1 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 135241
22 September 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 86540
28 June 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140421
6 June 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382788
27 May 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1170351
23 May 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438179
14 March 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 656377
29 November 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 86572
2 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 35840
13 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157214
2 June 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1155248
18 May 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469753
15 April 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373831
25 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 18985
19 January 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828009
16 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138633
10 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251405
3 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 76922
3 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212546
12 August 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958124
15 June 1992
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443319
10 June 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401628
13 May 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946114
5 November 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936630
21 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245550
14 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901825
24 January 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1220743
18 July 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923241
14 June 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235529
5 July 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1209097
16 June 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1341376
24 May 1989
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 900547
24 May 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1340113
31 October 1988
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1200737
13 May 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022509
11 June 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990938
6 June 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988241
13 May 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000043
28 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299116
7 April 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 997899
4 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988007
6 January 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1294609
13 November 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303730
17 October 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298632
19 September 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1299013
20 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290947
29 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 983301
26 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292467
28 January 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976004
24 December 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1286838
24 October 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282362
8 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280522
13 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970208
11 June 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964389
9 April 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276386
Construction/Loadline › Hull › Hull Plating
Issued 20 March 2009
No resolution recorded
Complete Phase II SEILOD NLT 19JUN09 or at next rig move, whichever sooner.
Action required: 705 - Other - as specified
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 17 June 2008
Resolved
Complete satisfactory repairs to fuel pump leak on #1 Generator Engine. Ensure that leak is monitored regularly and kept cleaned up.
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 23 June 2008
Resolution: Pump was renewed.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 17 June 2008
Resolved
Repair or renew emergency escape ladders to ensure free movement and allow for a reach that will not exceed a distance of 10' above the surface of the water.
Action required: 705 - Other - as specified
Due 17 September 2008
Resolved 13 October 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 12 April 2007
Resolved
UT Bulkhead between engine room and mudpit room in vicinity of pin holes; make proposal for repairs prior to using mudpits.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2007
Resolution: Received copy of ABS report that bulkhead had been UT''d and wasted areas had been cropped and renewed.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 19 April 2005
Resolved
Prove proper operation of sprinkler system for both lifeboats.
Due 20 May 2005
Resolved 18 May 2005
Lifesaving › Buoyant Smoke Signals › General
Issued 19 April 2005
Resolved
Provide two orange smoke signal flares for lifeboat #1. Current ones onboard are expired.
Due 20 May 2005
Resolved 18 May 2005
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 19 April 2005
Resolved
Prove proper operation of loss of purge alarm on the drill floor for the drill log 21C, drill graf, derrick camera monitor and top drive control system box.
Due 20 May 2005
Resolved 18 May 2005
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (air intake)
Issued 19 April 2005
Resolved
Replace hoses on emergency generator.
Due 20 May 2005
Resolved 18 May 2005
Lifesaving › Launching Appliances › Release Mechanism
Issued 1 June 2004
Resolved
RELEASE GEAR OVERDUE FOR WEIGHT TEST.
Condition: Improper/Lack of Maintenance
Due 26 June 2004
Resolved 22 June 2004
Resolution: WEIGHT TESTS COMPLETED ON BOATS AND RELEASE GEAR.
Construction/Loadline › Hull › Bottom Plating
Issued 5 April 2004
Resolved
Complete phase two of SEILOD inspection swim by of leg to spud can connections no later than 30June2004 or next rig move and provide ABS report/divers report to Morgan City Office.
Condition: Unknown
Due 30 June 2004
Resolved 30 June 2004
Resolution: Phase II completed. Rig is set for dry dock on 18 JULY 2004 to complete repairs noted during phase II.
Lifesaving › Lifeboat
Issued 23 July 2003
Resolved
Starboard lifeboat - Repair or replace hydraulic pump, intermittently seizes during engine operation
Condition: Improper/Lack of Maintenance
Due 6 August 2003
Resolved 1 August 2003
Resolution: Drive belt loose and worn, replaced and adjusted.
Electrical › Electric Generation Source (emergency)
Issued 23 July 2003
Resolved
Emergency Generator - Repair or replace water pump, leaks / Repair or replace oil filter or filter mount, excessive leak / Prove operation of auto start and auto-bus transfer / Thoroughly clean emergency enclosure - oil, rags, etc
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 August 2003
Resolved 1 August 2003
Electrical › Electrical Distribution System (emergency)
Issued 23 July 2003
Resolved
Operation of emergency autobus transfer. Transfer can be done manually. Auto start works. LEGACY COMPONENT DESC: Distribution Panel Bus
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 26 May 2004
Electrical › Electrical Distribution System (service)
Issued 23 July 2003
Resolved
Prove operation of #2 SCR reverse power relay LEGACY COMPONENT DESC: Overcurrent Device
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 26 May 2004
Lifesaving › Launching Appliances › Davit
Issued 1 May 2002
Resolved
PROVIDE LEVEL II NDT REPORT ON STBD DAVIT REPAIRS. PROVIDE DAVIT WT TEST. PROVE COMPLETION OF 17APR02 835 # 4. ALL TO [name withheld]
Condition: Improper/Lack of Maintenance
Due 30 May 2002
Resolved 6 May 2002
Resolution: PROVIDED COPY OF ALEXANDER/RYAN CERTIFICATE, AND NDT REPORT
Electrical › Electrical Distribution System (service) › Wiring
Issued 1 May 2002
Resolved
Address electrical safety involving intrensically safe and explosion proof penetrations, and connections. Properly strap all runs. Remove unapproved fixtures from haz locations. Remove dead end cables. Check all poured fittings.
Condition: Improper Installation
Due 30 May 2002
Resolved 7 May 2002
Resolution: via fax rcvd 08may02
Construction/Loadline › Hull
Issued 1 May 2002
Resolved
Conduct gauging at both inboard bkhd pitted areas P3, hull plate pitting at 45 degree bkhd in S3, stbd outbd bkhd ,floor, and aft bkhd of pit 1. Crop and renew/insert; holed and pitted area of hull plate tank top P5 rose box drain pipe S5, #1 pit stbd outbd bkhd as marked, and the grating support LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Due 30 June 2003
Resolved 10 March 2003
Resolution: Rcvd ABS survey documentation supporting the completion of the requirements.
Lifesaving › Launching Appliances
Issued 17 April 2002
Resolved
CONDUCT NDT ON FWD DAVIT BEAM APPROX. 8" INBOARD SIDE FROM END OF BEAM. PROVIDE RPT TO [name withheld]
Due 30 July 2002
Resolved 2 May 2002
Resolution: NDT/MP report from [name withheld] dated 05/02/02 with no indications.
Fire Fighting › Fire Main
Issued 17 April 2002
Resolved
CONDUCT NDT ON FIREMAIN PIPING @ STBD PIPE RACK DECK LEVEL ENTRANCE TO QTRS. PROVIDE REPORT/REPAIR PROC. TO [name withheld]
Due 17 May 2002
Resolved 13 May 2002
Resolution: ABS Survey report MC 17244
Fire Fighting › Fire Main
Issued 17 April 2002
Resolved
RESTORE FIREMAIN PIPING TO ORIGINAL CONFIGURATION @ FS#9 IN PUMP ROOM. PROVIDE ABS REPORT TO [name withheld].
Due 17 July 2002
Resolved 13 May 2002
Resolution: ABS report MC 17244
Lifesaving › Lifeboat Equipment
Issued 17 April 2002
Resolved
PROVIDE IN LB#1; THERMAL PROCTECTIVE DEFICES, 2 PAILS, BOAT HOOK, DRAIN CHECK BALL, HAND HELD FLARES, SEASICK KIT, RENEW RETRO AND DECALS TO IMO. LB #2 PROVIDE SAME W/ RENEW COX'N FWD WINDOW.
Due 17 May 2002
Resolved 8 May 2002
Resolution: E-Mail from company mgmt attesting to installation of missing gear, and photos.
Electrical › Lighting (service)
Issued 17 April 2002
Resolved
STRAP ALL WIRING ON RIG FLOOR, AND SHAKERS. PROPERLY TERMINATE AND DEAD-END WIRING.
Due 17 May 2002
Resolved 8 May 2002
Resolution: e-mail attesting to the repair and removal of items, and photos.
Fire Fighting › Miscellaneous Items
Issued 17 April 2002
Resolved
ADJUST AND REGASKET MUD PIT DOORS TO BE GAS TIGHT.
Due 30 September 2002
Resolved 1 August 2003
Resolution: Aas per company e-mail
Personnel › Manning/Qualifications
Issued 17 April 2002
Resolved
PROVIDE APPROIATE MANNING AS REQUIRED BY COI.
Due 17 May 2002
Resolved 8 May 2002
Resolution: As per company e-mail
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 17 April 2002
Resolved
PROVIDE/PROVE PROPER OPERATION OF FIRE EXTINGUISHING SYSTEM PROTECTING MOTO ROOM
Condition: Improper/Lack of Maintenance
Due 17 May 2002
Resolved 8 May 2002
Resolution: As per company e-mail
Deck/Cargo
Issued 25 April 2001
Resolved
Complete repairs and weight test port crane to the satisfaction of attending ABS surveyor. Forward copy of ABS report and statement of fact tothe [name withheld].
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Engineering
Issued 25 April 2001
Resolved
Re-configure lube oil line on lube oil purifier on all three main generators, no single section of flex line to exceed 30" in length.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Fire Fighting
Issued 12 May 2000
Resolved
PROVIDE U.S.C.G. APPROVED A-CLASS DOOR FOR CONTROL ROOM; ENSURE DOOR IS SELF CLOSING AND LATCHING.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Unknown
Issued 12 May 2000
Resolved
CONDUCT INTERNAL EXAM, GAUGE OR HYDROSTATICALLY TEST ALL AIR RECEIVERS AND BULK TANKS, TO SATISFACTION OF CLASS SURVEYOR OR MARINE INSPECTOR.
Condition: Unknown
Due 12 May 2000
Resolved 12 May 2000
Unknown
Issued 5 August 1999
Resolved
COMPLETE NDE OF REPAIRS TO LEG PINHOLES, MUD PIT BULKHEADS, TANK TOP TO #5 (P) DRILL WATER TANK, BULKHEAD ABOVE #3 (P & S) SALTWATER TANKS AND PIPE RACK DECK PLATING TO SATISFACTION OF ATTENDING MARINE INSPECTOR OR CLASS SURVEYOR. SUBMIT ALL REPORTS TO THE [name withheld].
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Engineering
Issued 19 May 1999
Resolved
INSTALL SAFETY RELIEF VALVE ON COLD RIG AIR COMPRESSOR BETWEEN COMPRESSOR DISCHARGE AND ISOLATION VALVE.
Condition: Unknown
Due 10 June 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
PROPERLY SECURE LADDER IN VOID #3 STBD.
Condition: Unknown
Due 19 June 1999
Resolved 25 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
COMPLETE NDE OF MAT TO LEG CONNECTIONS AND MAT SWIM-BY. PROVIDE COPY OF DIVERS REPORT AND VIDEO TO THE [name withheld].
Condition: Unknown
Due 19 June 1999
Resolved 25 July 1999
Electrical
Issued 19 May 1999
Resolved
CONDUCT SATISFACTORY TEST OF EMERGENCY TOTAL RIG SHUT-DOWN FROM ALL STATIONS, PROPERLY LOG THE SAME.
Condition: Unknown
Due 10 June 1999
Resolved 25 May 1999
Engineering
Issued 19 May 1999
Resolved
RE-PIPE FUEL SUPPLY AND RETURN LINES ON CEMENT UNIT. MAXIMUM ALLOWABLE LENGTH ON FUEL OIL FLEX LINE IS 30 INCHES.
Condition: Unknown
Due 25 May 1999
Resolved 25 May 1999
Engineering
Issued 19 May 1999
Resolved
PROVIDE DEAD MAN TYPE NOZZLE FOR REFUELING STATIONS.
Condition: Unknown
Due 10 June 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
COMPLETE GAUGINGS AS DIRECTED BY ABS, PROVIDE A COPY OF REPORT TO THE [name withheld].
Condition: Unknown
Due 19 June 1999
Resolved 25 July 1999
Lifesaving
Issued 19 May 1999
Resolved
PROPERLY SECURE MOTOR TO PUMP COUPLING GUARDS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 10 June 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
RENEW BILGE STRAINER IN VOID #7P.
Condition: Unknown
Due 19 June 1999
Resolved 25 May 1999
Electrical
Issued 19 May 1999
Resolved
PROPERLY INSTALL ELECTRICAL WIRING IN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 10 June 1999
Resolved 24 May 1999
Construction/Loadline
Issued 19 May 1999
Resolved
CROP AND RENEW WASTED AND HOLED MAIN DECK ABOVE VOID #7 PORT NEAR MAIN ENGINE EXHAUST THROUGH PIPING.
Condition: Unknown
Due 19 May 1999
Resolved 19 May 1999
Engineering
Issued 19 May 1999
Resolved
TROUBLE-SHOOT AND REPAIR REVERSE POWER RELAY ON #2 MAIN GENERATOR.
Condition: Unknown
Due 10 June 1999
Resolved 24 May 1999
Electrical
Issued 14 July 1998
Resolved
PROPERLY SECURE WIRING AND JUNCTION BOXES ON DRILL FLOOR AND SHALE SHAKER AREA, REMOVE DEAD END WIRING, THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 14 July 1998
Resolved
CROP AND RENEW WASTED SHROUD ON MUD PIT FANS.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Construction/Loadline
Issued 14 July 1998
Resolved
ADJUST, REPAIR OR REPLACE WATERTIGHT DOORS, HATCHES AND VENT CLOSURES THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
CONDUCT OPERATIONAL TEST OF RELEASE GEAR ON BOTH LIFEBOATS UNDER A LOAD OF 110% IN PRESENCE OF ATTENDING MARINE INSPECTOR OR PROVIDE AN ALTERNATE MEANS OF TESTING TO [name withheld].
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
IMPLEMENT AND LOG PROPERLY LIFERAFT DAVIT TRAINING, LINE THROWING_x001C_ APPLIANCE TRAINING AND INSPECTION OF EMERGENCY LIGHTING AT EVERY DRILL.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
RENEW WINDOWS TO BOTH LIFEBOATS.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
REPAIR / REPLACE REMOTE VALVE ASSEMBLIES FOR FUEL OIL HIGH AND LOW SUCTIONS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 14 July 1998
Resolved
REPLACE OUTDATED FLARES IN LIFEBOAT #1.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
EXPEDITE PLANS TO REPLACE SEWAGE TREATMENT SYSTEM.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Lifesaving
Issued 14 July 1998
Resolved
PROPERLY SECURE / STOW FLAMMABLES LOCATED NEAR PAINT LOCKER.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 14 July 1998
Resolved
MAKE MUD PIT DOORS SELF CLOSING AND GAS TIGHT.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
REPLACE MISSING CEILING TILES IN DRY STORES. PROVIDE COVER GUARDS OVER REEFER COMPRESSOR EQUIPMENT.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Fire Fighting
Issued 14 July 1998
Resolved
PROVIDE CLOSURE DEVICES FOR GALLEY FIRE DOOR (2).
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
PROVIDE PROPER NUMBER OF LOCKERS IN ALL BIRTHING SPACES AS NECESSARY.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
INSTALL SAFETY PRESSURE RELIEF VALVE ON COLD RIG START AIR COMPRESSOR BETWEEN DISCHARGE OUTLET AND ISOLATION VALVE.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
UPDATE AND SUBMIT TO [name withheld] FOR APPROVAL, FIRE AND LIFESAVING PLAN, TO ALSO REFLECT ADDITION OF NEW IMO SYMBOLS.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Electrical
Issued 14 July 1998
Resolved
PROPERLY LABEL MOTOR CONTROLLERS THROUGHOUT AS NECESSARY.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Lifesaving
Issued 14 July 1998
Resolved
REPLACE GENERAL ALARM BELL IN SCR ROOM. TRACE OUT POSSIBLE DELAY PROBLEM INGENERAL ALARM CIRCUIT.
Condition: Unknown
Due 17 July 1998
Resolved 17 July 1998
Electrical
Issued 14 July 1998
Resolved
CONDUCT AND LOG SATISFACTORY TEST OF EMERGENCY TOTAL RIG SHUT-DOWN AND RUN EMERGENCY GENERATOR UNDER A LOAD FOR TWO HOURS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 1 July 1997
Resolved
SUBMIT DIVER'S REPORT AND VIDEO OF UNDERWATER EXAM OF LEGS AND MAT TO [name withheld].
Condition: Unknown
Due 22 July 1997
Resolved 22 July 1997
Construction/Loadline
Issued 14 May 1997
Resolved
RENEW MANHOLE COVER FOR VOID 7P.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Accommodation/Occupational Safety
Issued 14 May 1997
Resolved
CROP AND RENEW WASTED SECTIONS OF SUPPLY VENT SHROUD IN MUD PIT ROOM AND WASTED SECTIONS OF VENT DUCTING IN COMPRESSOR ROOM.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Construction/Loadline
Issued 14 May 1997
Resolved
GUAGE BOTTOM TWO FEET OF WATERTIGHT BULKHEAD IN CORRODED ZONES OF VOID 4C. SUBMIT REPORT TO [name withheld].
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Fire Fighting
Issued 14 May 1997
Resolved
INSPECT ENTIRE FIREMAIN SYSTEM, CROP AND RENEW WASTED SECTIONS AS NECESSARY. COMPLETE PRIOR TO COMMENCING ANY FURTHER DRILLING OPERATIONS. _x001C__x001C_
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Electrical
Issued 14 May 1997
Resolved
TEST AUTO BUS TRANSFER ON EMERGENCY GENERATOR AND TOTAL RIG SHUT-DOWN.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Construction/Loadline
Issued 14 May 1997
Resolved
COMPLETE PHASE II (UNDERWATER SWIM-BY, CRITICAL CONNECTIONS) HULL EXAM.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Electrical
Issued 14 May 1997
Resolved
REPLACE PLASTIC WIRE TIES ON CABLE RUNS ON DRILL FLOOR WITH METAL BANDING.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Lifesaving
Issued 14 May 1997
Resolved
PROVIDE NEW AIR HOIST FOR TEXAS DECK.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Construction/Loadline
Issued 14 May 1997
Resolved
REPLACE DOOR OPEN INDICATOR LIGHT IN MUD PIT ROOM.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Electrical
Issued 14 May 1997
Resolved
REPLACE CRACKED GLASS ON SELECTOR PANEL OF DRILLERS CONSOLE WITH TEMPERED GLASS.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Lifesaving
Issued 14 May 1997
Resolved
CROP AND RENEW WASTED FRAMING UNDER CATWALK TO V-DECK IN ACCORDANCE WITH APPROVED SUBMITTED PROPOSAL.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Construction/Loadline
Issued 14 May 1997
Resolved
GAUGE PITTED AREAS ON DECK IN VOID 9C, FIRST BAT STARBOARD SIDE; GUAGE PITTED AREAS ON SWASH BULKHEAD ON PORT SIDE FROM BOTTOM UP TWO FEET. SUBMIT REPORTS TO [name withheld].
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Unknown
Issued 14 May 1997
Resolved
COMPLETE WORKLIST ISSUED BY ABS ON 13MAY97.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Fire Fighting
Issued 14 May 1997
Resolved
PROVIDE TWO FULL SCBA BOTTLES WITHIN HYRO DATE FOR EACH FIREMANS OUTFIT. PROVIDE ONE ADDITION TENDING LINE.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Lifesaving
Issued 14 May 1997
Resolved
RENEW DAMAGED LIFERAFT DAVIT FALLS ON STARBORD SIDE. WEIGHT TEST TO 110% CAPACITY. PROVIDE 3rd PARTY CERTIFICATE OF WEIGHT TEST TO OCMI MORGAN CITY.ENSURE COMPANY MAINTAINS STAND-BY VESSEL AT RIG UNTIL COMPLETE.
Condition: Unknown
Due 23 May 1997
Resolved 23 May 1997
Electrical
Issued 14 May 1997
Resolved
PROVIDE NEW SWITCHES FOR CONTROL BOXES FOR FUEL TRANSFER PUMP #2, SUPPLY VENT IN PUMP ROOM, EXHAUST FAN FOR MUD PITS, AND EXHAUST VENT IN COMPREESORROOM.
Condition: Unknown
Due 14 May 1997
Resolved 14 May 1997
Construction/Loadline
Issued 23 October 1996
Resolved
SUBMIT REQUIRED PLANS, ASME CERTIFICATES OF COMPLIANCE, STRUCTURAL ANALYSIS, AND STABILITY REVIEW FOR PROPOSED BULK TANK INSTALLATION TO OCMI.
Condition: Unknown
Due 23 October 1996
Resolved 23 October 1996
Lifesaving
Issued 14 August 1996
Resolved
CONDUCT PERMANENT REPAIRS IN WAY OF PITTING ON STBD FWD DRY BULK TANK, IN PRESENCE OF AUTHORIZED INSPECTOR NO LATER THAN 15SEP96._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 August 1996
Resolved 14 August 1996
Accommodation/Occupational Safety
Issued 19 June 1996
Resolved
FREE UP DOOR TO STAIRWELL ON LOWER LEVEL IN ACCOMODATIONS.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Lifesaving
Issued 19 June 1996
Resolved
ADJUST MUD PIT ROOM DOORS. ENSURE GAS TIGHT SEAL.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Construction/Loadline
Issued 19 June 1996
Resolved
CROP AND RENEW WASTED BULKHEAD, ADJACENT TO FAN IN MUD PIT ROOM.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Lifesaving
Issued 19 June 1996
Resolved
REPAIR GENERAL ALARM IN SHOP AND SHAKER ROOM.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Accommodation/Occupational Safety
Issued 19 June 1996
Resolved
REPAIR HOLE IN AIR LINE TO MSD.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Documentation
Issued 19 June 1996
Resolved
PROVIDE ON BOARD APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Deck/Cargo
Issued 19 June 1996
Resolved
GAUGE PITTING ON STARBOARD, FORWARD DRY BULK TANK. GAUGING MUST BE REPRESENTATIVE OF EXCESSIVE PITTING ON LOWER, OUTBOARD PORTION OF TANK.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Lifesaving
Issued 19 June 1996
Resolved
PROVIDE MONKEYS FISTS OR BUOYANT COIT FOR BOTH HEAVING LINES IN LIFEBOAT #1.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Electrical
Issued 19 June 1996
Resolved
REPLACE BATTERY FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 19 June 1996
Resolved 19 June 1996
Construction/Loadline
Issued 22 May 1995
Resolved
SUBMIT REPAIR PROPOSAL TO USCG/ABS UPON COMPLETION OF INSPECTION OF MUD PUMP ROOM BILGE AND BULKHEAD AREAS.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Lifesaving
Issued 22 May 1995
Resolved
PROVIDE BREATHING AIR BOTTLES (2) FOR THE #1 LIFEBOAT WITH CURRENT HYDRO TEST (WITHIN 5 YEARS).
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Construction/Loadline
Issued 22 May 1995
Resolved
CLEAN AND MAKE READY FOR INSPECTION BY ABS/USCG, BILGE AND BULKHEAD AREAS OF MUD PUMP ROOM.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Engineering
Issued 22 May 1995
Resolved
RENEW AS ORIGINAL WASTE OIL TANK DECK VENT.
Condition: Unknown
Due 22 May 1995
Resolved 22 May 1995
Electrical
Issued 6 June 1994
Resolved
TEST THE FOLLOWING REMOTE SHUTDOWNS: 1. TOTAL RIG 2. FUEL TRANSFER PUMPS_x001C_ 3. VENTILATION
Condition: Unknown
Due 6 June 1994
Resolved 6 June 1994
Construction/Loadline
Issued 23 May 1994
Resolved
COMPLETE UNDERWATER SWIM-BY OF THE UNDERNEATH SIDE OF THE MAT.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 2 June 1993
Resolved
MAKE PERMANENT REPAIRS TO THE AFT STBD LEG COLUMN DAMAGE AT LEVEL 102'-9" IN ACCORDANCE WITH REPAIR PROPOSAL FROM BETHSHIP DATED 25MAY93.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE ONBOARD VESSEL THREE (3) PARACHUTE FLARES.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993
Resolved
CLEAN SIGHT GLASS ON THE FOLLOWING TANKS IN THE PUMPROOM: SOLUBLE OIL; GEAR OIL; CHAIN OIL; HYDRAULIC OIL.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993
Resolved
REPLACE COOLING WATER HOSES TO COMPRESSORS IN COMPRESSOR ROOM.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
REPAIR WTD #2 (DOES NOT CLOSE PROPERLY).
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
MAKE PRESSURE VESSEL ON DRILL FLOOR (AND RELIEF VALVE) AVAILABLE FOR USCG INSPECTION.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
REPAIR WATER TIGHT DOOR # 10 (DOES NOT CLOSE).
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
INSTALL RELIEF VALVES, WITH HANK LIFT, SET AT 40 PSI OR LESS, AT STEP DOWN FROM CPMPRESSOR TO BULK TANK.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
REPAIR WATERTIGHT DOOR FROM MAIN DECK TO PUMP ROOM, (FROZEN, DOES NOT CLOSE).
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Fire Fighting
Issued 18 May 1993
Resolved
REPLACE AND TEST IN PRESENCE OF USCG INSPECTOR, GASKET ON SEA VALVE TO FIREPUMP IN COMPRESSOR ROOM.(WHEN PUMP OPERATES, VALVE LEAKS)
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE FALL RENEWAL DATES FOR #1 LIFEBOAT AND #3,#4 LIFERAFT DAVITS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993
Resolved
PROVIDE PROOF OF HYDRO TEST, AND PROPERLY MARK OIL TRANSFER HOSE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
INSTALL LANYARD ON #4 LIFERAFT HOOK RELEASE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Fire Fighting
Issued 18 May 1993
Resolved
PROVIDE ONBOARD VESSEL ONE (1) NFPA 1962 50' LENGTH FIRE HOSE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
RENEW ALL WINDOWS IN LIFEBOAT #2 (PORT SIDE BOAT).
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #1 (STARBOARD): HYDROSTATIC TEST AIR CYLINDERS, REPAIR OR RENEW ENGINE COVER LATCHES.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Navigation
Issued 18 May 1993
Resolved
RENEW LENS ON THE FOLLOWING OBSTRUCTION LIGHTS: PORT AFT AND STARBOARD BOW.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
MAKE EMERGENCY LIGHTING FOR DAVIT LIFERAFTS AND P/S LIFEBOATS PERMENENT. (NOT TO BE ROTATABLE)
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
FREE-UP, OR REPLACE ALL SELF-CLOSING CABLES ON WATERTIGHT DOORS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
MAKE HATCH IN OVERHEAD OF ENGINEROOM WATERTIGHT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
REPAIR OVERSPEED TRIP ON EMERGENCY DIESEL ENGINE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
REPAIR EMERGENCY GENERATOR EXHAUST (RE-ATTACH @ OVERHEAD) OR REPLACE EXHAUST PIPING.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
REPLACE MISSING BOLT ON EXPLOSION PROOF BOX IN MUD ROOM.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
REPACK, AT BULKHEAD, WIRES WHICH PASS FROM MUD-PIT ROOM TO PUMP ROOM.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE DOCUMENTATION THAT CERTIFIED SERVICING AGENT HAS MADE OPERATIONAL DAVIT FOR LIFERAFT #4.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE PROPER OPERATION OF REMOTE BRAKE RELEASE ON DAVIT LIFERAFT #4.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
CONDUCT WEIGHT TEST ON DAVIT FOR #4 LIFERAFT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
RE-ATTACH PULLY FOR BRAKE CONTROL CABLE ON #1 LIFEBOAT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVE PROPER OPERATION OF LIMIT SWITCHES ON #1 AND #2 LIFEBOAT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993
Resolved
INSTALL FLAME SCREEN (30X03 MESH) ON DIESEL FUEL TANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993
Resolved
RENEW GASKET AND STRAIGHTEN DOG ON VENT OUTBOARD OF BARITE TANKS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Electrical
Issued 18 May 1993
Resolved
INSTALL BLANK IN LIGHTING PANEL IN WAY OF #15 FIRE EXTINGUISHER.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993
Resolved
REPLACE SIGHT GLASS ON DIESEL OIL TANK IN ENGINE ROOM (CURRENTLY MISSING).
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVE PROPER OPERATION FOR DAVIT FOR LIFEBOAT #4.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993
Resolved
RENEW CONTAINMENT UNDER WASTE OIL TANK IN WAY OF SHALE SHAKER AREA.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
INSTALL RELIEF VALVES ON HOT WATER HEATERS FOR NOT MORE THAN 100 PSI @ 210F.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993
Resolved
INSTALL EXHAUST FLAP ON TOP OF EXHAUST PIPE FOR STARBOARD CRANE ENGINE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993
Resolved
REPLACE SEVERELY CRACKED VIBRATOR (MUD) HOSE LOCATED NEAR SHAKERS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
REPAINT LOADLINE MARKS AND 12" X 1" DECKLINE ON PORT AND STARBOARD SIDES OFHULL.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
RENEW HANDRAIL WHERE DAMAGED ON STARBOARD SIDE OF MAIN DECK.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 18 May 1993
Resolved
SUBMIT REPAIR PROPOSAL FOR PINHOLE REPAIR TO STBD AFT LEG, PINHOLE AT 102.5' LEVEL 7 O'CLOCK POSITION. MAKE PROPER REPAIRS IN ACCORDANCE WITH APPROVED CONSTRUCTION PORTFOLIO USING CERTIFIED WELDERS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
REPLACE TWO RING BOUYS AS INDICATED AND RELOCATE TWO RING BOUYS LOCATED BEHIND BULKTANKS (1-PORT AND 1-STBD). CLEAN WATER LIGHT LENS.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Accommodation/Occupational Safety
Issued 18 May 1993
Resolved
REPLACE DRYER VENT HOSE WITH METAL VENT DUCT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Lifesaving
Issued 18 May 1993
Resolved
PROVIDE THE FOLLOWING ITEMS FOR LIFEBOAT #2 (PORT SIDE BOAT): 40 BAGS POTABLE WATER, REPAIR OR RENEW HOLDDOWN CLIPS ON ENGINE COVER.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Construction/Loadline
Issued 15 June 1992
Resolved
MAKE PERMANENT REPAIRS TO 6 INCH FRACTURE ON PORT FINGER OF MAT AT JUNTION OF MAT TOP AND STERN PLATING OF FINGER. REPAIRS TO BE COMPLETED WITHIN 15 DAYS OF COMPLETION OF PRESENT JOB BUT NO LATER THAN 30 SEPT 1992.
Condition: Unknown
Due 15 June 1992
Resolved 15 June 1992
Documentation
Issued 10 June 1992
Resolved
SUBMIT OPERATION MANUAL FOR APPROVAL PER 46 CFR 109.121.
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Construction/Loadline
Issued 10 June 1992
Resolved
CONDUCT UNDERWATER PORTION OF S.E.I.L.O.D. (E.G. NDE OF HIGH STRESS AREAS AND SWIM-BY) AT NEXT RIG MOVE.
Condition: Unknown
Due 10 July 1992
Resolved 18 June 1992
Electrical
Issued 21 May 1991
Resolved
POUR EYS TO LIGHT ATTACHED TO OVERHEAD SUBSTRUCTURE BENEATH STBD FWD RIG FLOOR.
Condition: Unknown
Due 11 July 1991
Resolved 11 July 1991
Electrical
Issued 21 May 1991
Resolved
PROVIDE EXPLOSION PROOF FLASHLIGHT FOR THE FIREMAN'S OUTFIT IN MUD PUMP ROOM.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Electrical
Issued 21 May 1991
Resolved
REMOVE SCOTT SPLICE ABOVE SKID CONSOLE AND REPLACE WITH JUNCTION BOX OR RERUN WITH PROPER TYPE OF CABLE.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 21 May 1991
Resolved
REMOVE SMOKE ALARM FROM PAINT LOCKER OR MAKE SAFE FOR ZONE 1 DIVISION 1 LOCATION.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Lifesaving
Issued 21 May 1991
Resolved
GREASE ENTIRE FALLS AND PROPERLY WIND ON DRUMS FOR DAVIT LAUNCHED LIFE RAFTS: #1 AND #2.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 21 May 1991
Resolved
PROPERLY MOUNT ALL LIFE RING BOUYS.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Navigation
Issued 21 May 1991
Resolved
PROVIDE PROPER NAVIGATION RUNNING LIGHT FOR STARBOARD SIDE OF VESSEL.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 21 May 1991
Resolved
RENEW SHEAVE BUSHINGS ON PORT AND STARBOARD LIFE RAFT DAVITS._x001C_
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Electrical
Issued 21 May 1991
Resolved
PROPERLY MARK ALL EMERGENCY LIGHTS FOR LIFEBOATS AND LIFERAFT STATIONS.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Fire Fighting
Issued 21 May 1991
Resolved
PROPERLY INSTALL FIRE HYDRANT #7 AND #3 TO PREVENT POINTING ABOVE THE HORIZONTAL AS PER 46 CFR 108.423.
Condition: Unknown
Due 21 May 1991
Resolved 21 May 1991
Lifesaving
Issued 14 June 1990
Resolved
REPAIR THE BREATHING AIR SYSTEM IN THE PORT BOAT.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
REPAIR THE BREATHING AIR SYSTEM IN THE PORT AND STBD BOATS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
RENEW THE CONTACTORS IN THE PORT AND STBD WINCH CONTOLLERS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
PROVIDE THE PROPER MANUFACTUERERS INSTRUCTIONS FOR THE LIFERAFT WINCHES.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROPERLY SUPPORT OVERHEAD RUN OF WIRING TO LIGHT STBD SIDE RIG FLOOR.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
POUR EYS ON RIG SHUTDOWN SWITCH AND TONG UNIT EXPLOSION PROOF SWITCH BOXES ON DRILLER'S CONSOLE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
POUR EYS FITTING FOR EXPLOSION PROOF SWITCH BOX FOT ELECTRIC BRAKE ON DRILLER'S CONSOLE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPAIR AUDIBLE LOSS OF PURGE ALARM TO DRILLER'S CONSOLE AND INSTRUMENTATIONCABINET ON RIGFLOOR.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROVIDE EXPLOSION PROOF INSTALLATION FOR GEOGRAPH UNIT ON RIG FLOOR. FOR CLASS I DIV II AREA/ UNIT CURRENTLY HAS OPEN CONTACTORS WITH TOGGLE SWITCHES UNIT MAY BE PURGED IN ACCORDANCE WITH NFPA-496
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REMOUNT PROPERLY 3 EXPLOSION PROOF JUNCTION BOXES BEHIND TOTCO PANEL.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROVIDE EXPLOSION PROOF HORN FOR WMCO PIT LEVEL ALARM ON RIG FLOOR. INSTALLATION MUST BE IL, FM, OR CSA APPROVED IN ACCORDANCE WITH CHAPTER 500NATIONAL ELECTRIC CODE AND 46 CFR SUBCH J.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROPERLY INSTALL EXPLOSION PROOF JUNCTION BOX LOCATED AFT CATWALK BENEATH RIG FLOOR.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
REPAIR THE LEAKS IN THE HATCHES AND WINDOWS ON THE STARBOARD BOAT.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
PROVIDE A CAP FOR THE LAUNCHING CABLE PENETRATING IN PORT AND STBD BOAT ROOF.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
CLEAN THE BILGE IN THE STBD BOAT.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
REPAIR THE AFT LIMIT SWITCH ON THE STBD BOAT DAVIT.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Deck/Cargo
Issued 14 June 1990
Resolved
PROVIDE "DEAD MAN" TYPE FUEL NOZZELS FOR THE CRANE FUELING HOSES.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPAIR THE SPLICE IN THE ELECTRIC CABLE IN THE PORT CRANE PEDESTAL.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
FREE THE BRAKE LEVER ON THE PORT LIFEBOAT.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
HARD WIRE THE LIGHTS FOR THE PORT CRANE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
PAINT THE STARBOARD LIFEBOAT INTERNATIONAL ORANGE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
REPAIR THE EXHAUST LEAKS IN THE STARBOARD BOAT ENGINE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Documentation
Issued 14 June 1990
Resolved
PERFORM AND LOG ALL DRILLS, TESTS, AND INPECTIONS AS REQUIRED BY 46 CFR 109.207-211,213,.215,.217,.221, AND .228
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Documentation
Issued 14 June 1990
Resolved
PAINT THE LOADLINE MARK AND PLIMSOL MARK ON THE STARBOARD SIDE OF THE VESSEL.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPAIR THE ELECTRIC CABLE CONNECTION TO THE MECHANICAL VENT OUTSIDE OF THE SKID BEAM ON THE STBD SIDE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Accommodation/Occupational Safety
Issued 14 June 1990
Resolved
LOWER ONE (1) ESCAPE LADDER ON EACH SIDE OF THE VESSEL SO THAT THE BOTTOM IS WITHIN 20' OF THE WATER.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
CLEAR ACCESS TO THE LIFERING BEHIND THE P-TANKS ON THE STARBOARD SIDE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPAIR THE ELECTRICAL CABLE DECK PENETRATIONS(KICK PIPES) FOR THE MECHAN- ICAL SHOP VENTS AND ON THE MAIN DECK PORT SIDE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
PROVIDE A FIRST AID KIT WITH 15 TRIANGUALR BANDAGES, 8-4" BANDAGE COMPRESS-ES AND TWO LEG AND TWO ARM SPLINTS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Lifesaving
Issued 14 June 1990
Resolved
PROVIDE A TOTAL OF THREE REWINDING SPINDLES AND A PLASTIC OF INSTRUCTIONS FOR THE LINE THROWING GUN.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REHANG/SUPPORT ALL WIRING BENEATH RIG FLOOR,PLASTIC TIE WRAPS NOT PERMITTED. BANDING MATERIAL IF USED MUST BE A MINIMUM OF 5/8" IN DIAMETER, NON- CORROSIVE METAL BANDS IN ACCORDANCE WITH IEEE-45.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROVIDE EXPLOSION PROOF PHONE FOR SHALE SHAKER AREA OR PURGE IN ACCORDANCE WITH NFPA-496 OR REMOVE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Deck/Cargo
Issued 14 June 1990
Resolved
PROVIDE DOCUMENTATION DRIVE BELTS FOR DEGASSER, SHALE SHAKER, AND SWACO CENTRIFUGE, ARE CONDUCTIVE BELTS IN ACCORDANCE WITH NFPA77.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROVIDE SEALED FITTIG FOR DE-GASSER MOTOR.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
POUR EYS FITTING ON SWACO-GEOGRAPH CENTRIFUGE LOCATED IN SHALE SHAKER, ENSURE SEALANT IS POURED AROUND INDIVIDUAL CONDUCTORS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPAIR "E" LIGHT IN MUD PITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
POUR EYS FITTING ON DOOR CLOSURE LIGHT EXPLOSION PROOF SWITCH BOX IN MUD PITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROVIDE LOSS OF PURGE ALARM IN ACCORDANCE WITH NFP-496 FOR PHONE BOX IN MUDPITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROPERLY MOUNT GAS DETECTOR SENSOR IN MUD PITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Accommodation/Occupational Safety
Issued 14 June 1990
Resolved
RE-FILL AND MOUNT EYE WASH STATION IN MUD PITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Accommodation/Occupational Safety
Issued 14 June 1990
Resolved
REPLACE WASTEDD GUARD ON EXHUAST FAN MUD PITS.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
RELACE GENERAL ALARM BELL IN MUD PITS WITH UL, FM, OR CSA APPROVE FOR CLASSI DIV II LOCATION.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPLACE GUAGE TO LEMARQUE CHARGER IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
REPLACE BATTERY WITH BAD POST IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Construction/Loadline
Issued 14 June 1990
Resolved
ADJUST ALL MAIN DECK WATER TIGHT DOORS FOR PROPER CLOSURE.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Electrical
Issued 14 June 1990
Resolved
PROPERLY MARK GENERAL ALARM BELL IN PORT AFT JACKING ROOM.
Condition: Unknown
Due 14 June 1990
Resolved 14 June 1990
Fire Fighting
Issued 24 May 1989
Resolved
CONDUCT FIRE AND BOAT DRILLS WHEN CREW ASSIGNED AND PRIOR TO PLACING VESSELIN OPERATION.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Construction/Loadline
Issued 24 May 1989
Resolved
CONDUCT UNDERWATER EXAMINATION FOR CREDIT DRYDOCK PRIOR TO PLACING VESSEL IN OPERATION.
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Lifesaving
Issued 31 October 1988
Resolved
MAKE PERMANENT REPAIRS TO OR REPLACE THE PORT LIFEBOAT AND DAVIT.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Construction/Loadline
Issued 31 October 1988
Resolved
REPAIR THE DAMAGE TO THE RAILS IN THE AREA AROUND THE PORT LIFEBOAT.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Lifesaving
Issued 31 October 1988
Resolved
MAKE PERMANENT REPAIRS TO OR REPLACE THE MOVABLE LADDER NEXT TO THE PORT LIFEBOAT.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Construction/Loadline
Issued 31 October 1988
Resolved
MAKE PERMANENT REPAIRS TO THE 18" TEAR IN SIDESHELL AT THE 12' DRAFT MARK BELOW THE PORT DAVIT.
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Lifesaving
Issued 13 May 1986
Resolved
CONDUCT A WEIGHT TEST OF THE #1 LIFEBOAT IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE WTD MIDSHIP ACCESS TO THE TOOLPUSHERS OFFICE.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE WTD MUD PUMP ROOM ACCESS TO THE SCR ROOM.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
PLACE A BLANK COVER ON SLOT 19 OF THE CIRCUIT BREAKER PANEL #2 (ADJACENT TOSTATEROOM 12).
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE SECOND DECK REC-ROOM MAIN PASSAGE DOOR (#19).
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE MAIN DECK PORTSIDE FIRE DOOR ACCESS TO THE CHANGE ROOM.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE AUTO CLOSING DEVICE ON DOOR #33.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE STAIRTOWER DOOR #32.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE STAIRTOWER DOOR #18.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE AUTO CLOSING DEVICE TO THE GALLEY ACCESS DOOR
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 13 May 1986
Resolved
ADJUST FOR PROPER CLOSURE THE WTD MAIN ACCESS TO THE PORT SIDE CHANGE ROOM.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
RENEW THE CRACKED MOTOR CONNECTION JUNCTION BOX ON THE #1 SHALESHAKER PUMP MOTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
POUR ALL (EYS) FITTINGS ON ELECTRICAL EQUIPMENT IN THE PHONE BOOTH NEXT TO SHALESHAKER UNIT.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
PERMANENTLY WIRE LIGHTING SYSTEM (FLOOD LIGHTS) OVER DRILL FLOOR IN A MANNER SUITABLE FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
PROPERLY STRAP UP CABLE FROM SWITCH MOUNTED ON DRILLERS STAND WHICH RUNS BACK TO BREAKER PANEL MOUNTED ON REAR BULKHEAD.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Accommodation/Occupational Safety
Issued 13 May 1986
Resolved
REPLACE RELIEF VALVE ON AIR RECEIVER ATOP THE DRILL FLOOR AND TEST TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
MAKE REPAIRS OR REPLACE TELEPHONE BOX MOUNTED ON BULKHEAD IN FRONT OF THE SWACO UNIT UNDER THE DRILL FLOOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
REPACK STUFFING TUBE CABLE CONNECTION ON THE MIDDLE PUMP MOTOR IN THE MUD PIT ROOM.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
MAKE PERMANENT REPAIRS TO STUFFING TUBES THAT PENETRATE THE BULKHEAD IN THEMUD PIT ROOM. STUFFING TUBES SHALL HAVE NO MORE THAN ONE (1) CABLE PER TUBEAND ALL MUST BE PROPERLY PACKED.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 13 May 1986
Resolved
MAKE REPAIRS TO PULLEY/WEIGHT SYSTEM ON ALL DOORS ENTERING TO MUD PIT ROOM SO THAT ALL DOORS WILL PROPERLY SELF CLOSE.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Accommodation/Occupational Safety
Issued 13 May 1986
Resolved
RENEW ALL FLEXIBLE HOSES BETWEEN NIPPLE AT TOP OF ALL P-TANKS AND PIPING TORELIEF VALVES (TOTAL OF 5).
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Lifesaving
Issued 13 May 1986
Resolved
CONDUCT A WEIGHT TEST OF THE PORT LIFERAFT DAVIT IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Lifesaving
Issued 13 May 1986
Resolved
PROVIDE DOCUMENTATION OF THE ANNUAL SERVICING OF INFLATABLE LIFERAFT #4.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
REINSTATE THE NITROGEN PROPELLANT CYLINDER TO THE RIGHT SIDE HELIPORT BV SEMI-PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986
Resolved
REPLACE OR HAVE A HYDROSTATIC TEST CONDUCTED ON THE BOW LEG JACKING HOUSE FIREMANS SPARE SCBA CYLINDER.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Navigation
Issued 13 May 1986
Resolved
PLACE THE PROPER/DESIGNATED LIGHT BULBS AND FIXTURES IN THE VESSEL SIDE, STERN AND NOT-UNDER-COMMAND/SPECIAL OPS NAVIGATION LIGHTS.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Navigation
Issued 13 May 1986
Resolved
MOUNT THE STERN NAVIGATION LIGHTS JUNCTION BOXES TO AN ADJACENT STANCHION.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Lifesaving
Issued 13 May 1986
Resolved
CONDUCT A WEIGHT TEST OF THE #2 LIFEBOAT IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Lifesaving
Issued 13 May 1986
Resolved
CONDUCT A WEIGHT TEST OF THE STARBOARD LIFERAFT DAVIT IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 13 May 1986
Resolved
MAKE PERMANENT REPAIRS TO AIR PURGE SYSTEM ON DRILLERS CONSOLE AND TEST TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Electrical
Issued 4 March 1986
Resolved
REPAIR AND TEST THE EMERGENCY GENERATOR AUTOMATIC BUS TIE CIRCUIT BREAKER.
Condition: Unknown
Due 4 March 1986
Resolved 4 March 1986
Electrical
Issued 17 October 1985
Resolved
REAPIR AND TEST THE EMERGENCY GENERATOR AUTOMATIC BUS TIE CIRCUIT BREAKER.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Electrical
Issued 17 October 1985
Resolved
REPAIR AND TEST THE PORT VENTILATION SYSTEM SHUTDOWN DEVICE
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE LAUNCHING INSTRUCTIONS FOR THE PORTQTR DAVIT LAUNCHED LIFERAFT STATION.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
LABEL EACH LIFERAFT STATION IN ACCORDANCE WITH FIRE AND SAFETY PLAN AND 46CFR108.647.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Accommodation/Occupational Safety
Issued 17 October 1985
Resolved
ADJUST THE ACCOMODATION SPACE DOOR FROM CLOSURE ON THE STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
MOUNT AND EQUIP ALL LIFERINGS IN ACCORDANCE WITH FIRE AND SAFETY PLAN AND 46CFR108.515.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Fire Fighting
Issued 17 October 1985
Resolved
PROVIDE ONBOARD AN OPERABLE OXYGEN COMBUSTABLE GAS ANALYZER.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985
Resolved
REMOVE ALL LOCKING HASPS FROM WATERTIGHT DOORS TO MANNED SPACES.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE DOCUMENTATION OF THE LAST LIFEBOAT ANNUAL FUEL CHANGE.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985
Resolved
INSTALL "BEWARE OF TAIL ROTOR" SIGNS AT EACH ACCESS TO THE HELO DECK
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Engineering
Issued 17 October 1985
Resolved
REPLACE OR CONDUCT A HYDROSTATIC TEST OF THE FOLLOWING EQUIPMENT: (1) THE CO2 CYLINDERS OF THE HELODECK BV FIRE EXTINGUISHERS (2) SPARE SELF-CONTAINED BREATHING APARATUS (SCBA) BOTTLES (3) MUD PUMP ROOM OUTFIT SCBA CYLINDER
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Accommodation/Occupational Safety
Issued 17 October 1985
Resolved
PROVIDE A DOOR HANDLE FOR STATEROOM #23 (LOWER BERTHING LEVEL)
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE FOR THE PORT LIFEBOAT ONE BOATHOOK AND ONE RED HAND-HELD FLARE.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE 18 LIGHTS FOR THOSE EXPIRED ON LIFEJACKETS.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Electrical
Issued 17 October 1985
Resolved
TEST ALL OF THE AIR PURGE SYSTEMS ON THE DRILL FLOOR.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE THREE FULLY EQUIPPED ADULT TYPE I LIFEJACKETS FOR A TOTAL OF 62 ONBOARD. UNTIL SUCH TIME MANNING OF THE VESSEL SHALL BE REDUCED TO 47 PERSONNEL (MAXIMUM).
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Electrical
Issued 17 October 1985
Resolved
REPLACE AND TEST THE #2 GENERATOR BUS TIE CIRCUIT BREAKER AND TEST THE REVERSE POWER RELAY IN THE SAME.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Electrical
Issued 17 October 1985
Resolved
REPAIR AND TEST THE MUD PUMP ROOM VENTILATION FAILURE ALARMS (2)
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985
Resolved
REINSTALL THE MISSING WATER TIGHT DOOR POSITION INDICATING DEVICE ON THE STARBOARD MUD PIT ROOM WTD.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Electrical
Issued 17 October 1985
Resolved
PROPERLY REWIRE THE 220V RECEPTACLE WITH A EYS FITTING BEHIND THE DRAW WORKS ON THE DRILL FLOOR
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE 12 HAND-HELD PROPELLED RED FLARES ONBOARD THE VESSEL.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
CONDUCT FIRE AND ABANDON VESSEL DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Accommodation/Occupational Safety
Issued 17 October 1985
Resolved
REINSTATE THE STAIRTOWER DOOR AUTO CLOSING DEVICE AT THE UPPER DECK LEVEL ACROSS FROM REC-ROOM.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Lifesaving
Issued 17 October 1985
Resolved
PROVIDE FOR THE STARBOARD LIFEBOAT ONE BOATHOOK AND 2 RED HAND-HELD FLARES.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Deck/Cargo
Issued 17 October 1985
Resolved
PROVIDE ONBOARD THE RIG ONE STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Construction/Loadline
Issued 17 October 1985
Resolved
RENEW THE DECK DRAIN COVER PLATES AROUND THE ROTARY TABLE WITH THICKER GAUGE METAL TO THE EXTENT THAT IT WILL REMOVE THE PRESENT TRIPPING HAZARDS.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985
Unknown
Issued 20 June 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, BROUGHTON I, DN619440
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Documentation
Issued 20 June 1985
Resolved
MAKE RIG AVAILABLE FOR MID PERIOD INSPECTION BY COAST GUARD (REF 46 CFR 107.269)
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Construction/Loadline
Issued 20 June 1985
Resolved
REPAIR 2" BY 1/4" CRACK LOCATED PORT SIDE AFT OF MAT IN THE PRESENCE OF U.S. COAST GUARD INSPECTOR 46 CFR 108.13.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Construction/Loadline
Issued 20 June 1985
Resolved
REPAIR 1/2" BY 10" CRACK LOCATED STARBOARD SIDE OUTBOARD OF KEYWAY IN THE PRESENCE OF A U.S. COAST GUARD INSPECTOR 46 CFR 108.113.
Condition: Unknown
Due 20 June 1985
Resolved 20 June 1985
Unknown
Issued 8 May 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL BROUGHTON I, DN619440.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Documentation
Issued 8 May 1984
Resolved
SUBMIT A FIRE CONTROL AND CLASSIFIED LOCATION PLAN FOR APPROVAL TO THE OFFICER IN CHARGE AND PROVIDE A COPY ON BOARD THE RIG. 46 CFR 107.305(V).
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Documentation
Issued 8 May 1984
Resolved
SUMBIT A CONSTRUCTION PORTFOLIO TO THE EIGHT DISTRICT MARINE TECHNICAL OFFICE FOR APPROVAL AND PROVIDE A COPY ON BOARD. 46 CFR 107.305.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Electrical
Issued 8 May 1984
Resolved
REPAIR THE REMOTE VENTILATION EMERGENCY SHUTDOWN. 46 CFR 111.80-13.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Accommodation/Occupational Safety
Issued 8 May 1984
Resolved
REPAIR OR REPLACE (1) ONE BULK TANK RELIEF VALVE WHICH IS INOPERATIVE. 46 CFR 54.15-5.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Unknown
Issued 8 May 1984
Resolved
PROVIDE A NIPPLE FOR FIRE STATION NUMBER 6. 46 CFR 109.33.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Unknown
Issued 8 May 1984
Resolved
PROVIDE A WIND DIRECTION INDICATOR FOR THE HELIPORT. 46 CFR 108.241
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Electrical
Issued 8 May 1984
Resolved
REPAIR THE LOSS OF VENTILATION ALARM IN THE MUD PIT. 46 CFR 111.92
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Electrical
Issued 8 May 1984
Resolved
PROVIDE AN EMERGENCY GENERATOR TEST SWITCH INDEPENDENT OF THE MAIN GENERATORS. 46 CFR 112.45-5 AND 46 CFR 112.15.
Condition: Unknown
Due 8 May 1984
Resolved 8 May 1984
Unknown
Issued 9 April 1982
Resolved
REPAIR ELECTRICAL CABLE ON #3 PRESSURE SWITCH TO ALARM PANEL.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
PROPERLY MOUNT THE FIRE EXTINGUISHER IN THE STBD CRANE.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
TEST AND REPAIR THE LOW LUBE ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
TEST FUEL OIL HOSES AND RECORD DATA IN ACCORDANCE WITH 33 CFR 154.500.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
SERVICE HYDROSTATIC RELEASES ON THE DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
REPAIRS THE SELF CLOSING DEVICES ON BOTH DOORS IN MUD PIT ROOM.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
TEST REVERSE POWER RELAYS ON ALL MAIN GENERATORS.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
TEST RELIEVE VALVES ON ALL PRESSURE VESSELS.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Unknown
Issued 9 April 1982
Resolved
TEST THE EMERGENCY FUEL OIL SHUT DOWN.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982