Records from 1982 to 1993. Most recent: inspection, 3 December 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
3 December 1993
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 849467
27 July 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239562
13 June 1988
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 889951
16 June 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000298
11 February 1987
Drydock Extension · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012684
17 December 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000994
10 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1310862
20 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1301541
4 February 1986
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305038
23 August 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986389
13 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1288683
29 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 979649
6 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287937
18 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286409
20 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278752
8 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971871
2 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279613
3 August 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271648
29 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274976
25 January 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965835
29 November 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964913
14 June 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964122
Fire Fighting
Issued 17 December 1986
Resolved
POST A LEGIBLE DIAGRAM AND/OR INSTRUCTIONS FOR FIXED FIREFIGHTING SYSTEM OPERATION.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Lifesaving
Issued 17 December 1986
Resolved
REPLACE STEERING RUDDER CONNECTING CABLES IN BOTH LIFE CAPSULES.
Condition: Unknown
Due 17 December 1986
Resolved 17 December 1986
Deck/Cargo
Issued 4 February 1986
Resolved
INSTALL FUEL OIL SHUT OFF VALVE ON THE PORT CRANE ENGINE FUEL OIL SUCTION LINE AS PER 46 CFR 56.50-60(D)(4).
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Deck/Cargo
Issued 4 February 1986
Resolved
INSTALL FUEL OIL SHUT OFF VALVE ON THE STARBOARD CRANE ENGINE FUEL OIL SUCTION LINE AS PER 46 CFR 56.50-60(D)(4).
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Accommodation/Occupational Safety
Issued 4 February 1986
Resolved
TEST RELIEF VALVES ON THE TWO RIG AIR RECEIVERS.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Electrical
Issued 4 February 1986
Resolved
INSTALL FUEL OIL SHUT OFF VALVE ON THE EMERGENCY GENERATOR FUEL OIL SUCTIONLINE AS PER 46 CFR 56.50-60(D)(4).
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Fire Fighting
Issued 4 February 1986
Resolved
PROVIDE A SECOND OPERABLE OXYGEN METER FOR THE SICKBAY/MAIN DECK FIREMANS OUTFIT.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Accommodation/Occupational Safety
Issued 4 February 1986
Resolved
REPAIR OR REPLACE THE DOORKNOB ON ACCESS FROM LOWER ACCOMODATION SPACES TO THE STOREROOM ON THE STARBOARD SIDE.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Electrical
Issued 4 February 1986
Resolved
REPAIR THE STARBOARD VENTILATION SHUTDOWN SWITCH.
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Lifesaving
Issued 4 February 1986
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO THE COMMENCING OF DRILLING OPERATIONS AND IN NO CASE LATER THAN 04JUN86
Condition: Unknown
Due 4 February 1986
Resolved 4 February 1986
Construction/Loadline
Issued 13 June 1985
Resolved
REPOSITION THE DECK DRAIN BOXES AND PIPING ON BOTH PORT AND STARBOARD MAIN DECKS AND ESTABLISH A DECK LINE MARK ABOVE THE LOADLINE PLIMSOLL.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985
Construction/Loadline
Issued 13 June 1985
Resolved
REPLACE THE WEATHER TIGHT DOOR AND FOOTING OF THE RIG CONTROL ROOM.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985
Electrical
Issued 18 January 1985
Resolved
MODIFY THE GENERAL ALARM SYSTEM SO THAT ALARM SIGNALS ARE AUDIBLE ON THE MAIN DECK BETWEEN THE CANTILEVER BEAMS.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Construction/Loadline
Issued 18 January 1985
Resolved
RENEW THE PORT JACK HOUSE WATERTIGHT DOOR SEAL AND ADJUST ALL THE WATERTIGHT DOORS TO INSURE A PROPER SEAL.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Accommodation/Occupational Safety
Issued 18 January 1985
Resolved
REPAIR THE OIL BATH AIR DRYER ON THE #3 AIR COMPRESSOR AND DEMONSTRATE PROPER OPERATION OF THE SYSTEM TO A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Accommodation/Occupational Safety
Issued 18 January 1985
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION BY A COAST GUARD INSPECTOR THE THREEBARITE TANKS, THE #2 CEMENT TANK AND THE DRILL FLOOR AIR RECEIVER.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Accommodation/Occupational Safety
Issued 18 January 1985
Resolved
TEST THE RELIEF VALVES ON THE THREE BARITE TANKS, THE #2 CEMENT TANK, THE AIR RECEIVER IN THE AIR COMPRESSOR ROOM AND THE THREE AIR COMPRESSOR AIR COOLERS.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Construction/Loadline
Issued 18 January 1985
Resolved
EFFECT PERMANENT REPAIRS TO THE FRACTURE IN THE PORT MAT FINGER ON THE AFTER END IN WAY OF THE #4 PORT TANK TOP AND SIDE SHELL PLATING, AT THE NEXT RIG MOVE.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Construction/Loadline
Issued 18 January 1985
Resolved
COMPLETE AN UNDERWATER SURVEY OF THE SIDES AND BOTTOM OF THE MAT AT THE NEXT RIG MOVE.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Electrical
Issued 18 January 1985
Resolved
MARK ALL EMERGENCY LIGHT FIXTURES WITH "E".
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Lifesaving
Issued 18 January 1985
Resolved
SUPPLY A SERVICEABLE FIRE EXTINGUISHER, A LIFELINE, AND DRINKING WATER FOR LIFESAVING CAPSULE #2.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Lifesaving
Issued 18 January 1985
Resolved
PROVIDE ONE SERVICE LINE FOR THE SHOULDER TYPE LINE THROWING GUN.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Construction/Loadline
Issued 18 January 1985
Resolved
EFFECT PERMANENT REPAIRS TO THE SET UP BOTTOM PLATE AND RENEW ASSOCIATED DAMAGED LONGITUDINAL AND TRANSVERSE FRAMING IN THE #5 PORT VOID TANK.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Lifesaving
Issued 18 January 1985
Resolved
CONDUCT DAVIT AND HOOK RELEASE TESTS AT ALL OF THE INFLATABLE LIFERAFT STATIONS.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Navigation
Issued 18 January 1985
Resolved
ADJUST THE FOG HORN TO EFFECT A PROPER SIGNAL.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Electrical
Issued 18 January 1985
Resolved
SECURE THE WIRE LEADS ON ALL THE FORCED VENTILATION FAN MOTORS.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Electrical
Issued 18 January 1985
Resolved
SECURE ALL HORIZONTAL WIRE RUNS IN THE SHAKERHOUSE.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Fire Fighting
Issued 18 January 1985
Resolved
SERVICE THE OXYGEN/COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 18 January 1985
Resolved 18 January 1985
Unknown
Issued 8 February 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE COMANCHE, DN629921.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
TEST THE LOW LUBE OIL PRESSURE SHUTDOWNS FOR THE #1, 2, AND 3 AC GENERATORSAND THE EMERGENCY GENERATOR.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
CONDUCT THE ANNUAL EXAMINATION FOR THE CRANES.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
TEST THE OVERSPEED TRIP FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE AND POST THE LABEL PLATE BY THE REACH ROD IN THE MUD PUMP ROOM FOR THE FUEL OIL DAY TANK SUCTION VALVE.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
POST WIRING DIAGRAM FOR GEN. ALARM SYS IN DISTRIBUTION PANEL, PROVIDE DIR- ECTORY CARD WITH FUSE SIZES, DESIGNATION & GEN ALARM BELLS & LTS FOR EACH.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE LABELS FOR ALL CIRCUIT BREAKERS, MOTOR CONTROLLERS, AND NAVIGATION SWITCHES.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROPERLY PACK WITH PACKING RINGS STUFFING TUBE FOR CABLE, CABLES ABOVE FIREEXTINGUISHER #41, CABLES ABOVE BOTTLE LANTERN, REMOTE CONTROL LINES.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE NEW RELIEF VALVE FOR AIR RECEIVER IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
ADJUST MUD PIT ROOM DOOR ON THE MAIN DECK TO SEAT GASKET AGAINST DOOR KNIFEEDGE.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
MAKE REPAIRS TO STARBOARD JOINER DOOR TO THE MUD PIT ROOM TO SEAT AGAINST DOOR GASKET.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE AND POST LABELS INDICATING THE CORRECT SETTINGS FOR ALL ADJUSTMENTSON THE LARGE CIRCUIT BREAKERS (GENERATOR, SCR, AND TRANSFORMERS).
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
REPAIR AND TEST THE #1 FIRE PUMP IN THE MUD PUMP ROOM.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
INSTALL VISIBLE OR AUDIBLE ALARM AS REQUIRED BY NFPA 496 FOR COOLING WATER PANEL, DISTRIBUTION PANEL, & SKID INDICATOR PANEL.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
BRING INTO COMPLIANCE THE TRANSFORMERS ON THE AFT BULKHEAD OF THE DRILL FLOOR WITH CFR 111.80-5(C)(2) FOR CLASS 1, DIVISION 2 HAZARDOUS LOCATION.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
MAKE CONTROL PANEL FOR DRILLING EQUIPMENT EXPLOSION PRROF AND PURGED TO MEET NFPA 496.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
MAKE REPAIRS TO AND TEST THE PURGE AIR GAUGE ON TOTCO'S DRILLER'S CONSOLE FOR PUMP STROKE COUNTER.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE PROOF ON BOARD THAT TOTCO CURRENT SENSOR AND TOTCO E/P DC SIGNAL DEVICES ON DRILL FLOOR ARE INTRINSICALLY SAFE.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 8 February 1984
Resolved
PROVIDE PERMANENT LABEL PLATES FOR THE REMOTE VENT SHUTDOWN AND VENTILATIONBREAKERS ON THE MAIN BOARD AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 8 February 1984
Resolved 8 February 1984
Unknown
Issued 2 February 1984
Resolved
REPLACE THE FOLLOWING PORTABLE FIRE EXTINGUISHERS WITH UL OR COAST GUARD APPROVAL: 4, 6, 9, 13, 15, 16, 18, 23, 32, 35, 38, 39 AND 40.
Condition: Unknown
Due 2 February 1984
Resolved 2 February 1984
Unknown
Issued 2 February 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE COMANCHE, DN629921.
Condition: Unknown
Due 2 February 1984
Resolved 2 February 1984
Unknown
Issued 2 February 1984
Resolved
SERVICE BOTH OXYGEN EXPLOSION METERS.
Condition: Unknown
Due 2 February 1984
Resolved 2 February 1984
Unknown
Issued 2 February 1984
Resolved
SERVICE THE #1 LIFERAFT.
Condition: Unknown
Due 2 February 1984
Resolved 2 February 1984
Unknown
Issued 2 February 1984
Resolved
PROVIDE FOR CAPSULE #1 A DOOR WINDOW, 1 FLOATING ORANGE DISTRESS SIGNAL, 1 SEA ANCHOR; FOR CAPSULE #2 1 FLOATING ORANGE DISTRESS SIGNAL, 1 SEA ANCHOR.
Condition: Unknown
Due 2 February 1984
Resolved 2 February 1984