Records from 1982 to 1986. Most recent: inspection, 15 August 1986.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
15 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 998775
21 September 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 991463
15 August 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973704
1 August 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282009
20 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975667
26 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281267
14 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971527
14 February 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973412
15 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278269
15 December 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280603
2 November 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965106
Accommodation/Occupational Safety
Issued 21 September 1985
Resolved
REMOVE THE OLD SANITARY SYSTEM PRESSURE TANK AND INSTALL THE NEW PRESSURE VESSEL.
Condition: Unknown
Due 5 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 September 1985
Resolved
REPAIR THE BUNK LIGHTS IN EACH STATEROOM.
Condition: Unknown
Due 21 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 September 1985
Resolved
INSTALL PROPER LIGHTS WITH 3 AND 1/2 INCH FOCAL HEIGHT LAMPS IN THE SIDE LIGHT FIXTURES.
Condition: Unknown
Due 12 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 21 September 1985
Resolved
REPAIR OR REPLACE THE AUTOMATIC DOOR CLOSURE DEVICE ON THE FIRE DOOR BETWEEN THE UPPER AND LOWER LIVING QUARTERS.
Condition: Unknown
Due 5 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 21 September 1985
Resolved
INSTALL A SAFETY RAILING OR CHAIN AROUND THE CARGO HATCH ABOVE THE STAR- BOARD STOREROOM.
Condition: Unknown
Due 5 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 September 1985
Resolved
TEST THE EMERGENCY GENERATOR LOW LUBE OIL PRESSURE SHUTDOWN FUNCTION AND OVERSPEED DEVICE.
Condition: Unknown
Due 5 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 21 September 1985
Resolved
REPAIR THE GROUND DETECTION SYSTEM ON THE EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 5 October 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 20 July 1984
Resolved
REPAIR O2 WATER.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Lifesaving
Issued 20 July 1984
Resolved
INSTALL QUICK RELEASE RACKS FOR THE 2 RING BUOYS WITH SMOKE SIGNALS.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Lifesaving
Issued 20 July 1984
Resolved
CONDUCT OPERATIONAL TEST OF BOTH LIFEBOATS IN WATER.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Lifesaving
Issued 20 July 1984
Resolved
HOLD FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD INSPECTOR UPON CREWING UP.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Navigation
Issued 20 July 1984
Resolved
REPAIR PORT AFT OBSTRUCTION LIGHT.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Construction/Loadline
Issued 20 July 1984
Resolved
PRESENT TWO SLUGGING PIT TANK DUMP VALVES FOR INSPECTION.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Accommodation/Occupational Safety
Issued 20 July 1984
Resolved
REPLACE BROKEN DOGS ON VENT COVERS ON MAIN DECK.
Condition: Unknown
Due 20 July 1984
Resolved 20 July 1984
Documentation
Issued 2 November 1982
Resolved
CONDUCT ANNUAL LOADLINE SURVEY
Condition: Unknown
Due 2 November 1982
Resolved 2 November 1982
Deck/Cargo
Issued 2 November 1982
Resolved
CONDUCT ANNUAL CRANE INSPECTIONS IN ACCORDANCE WITH 46 CFR 107.259.
Condition: Unknown
Due 2 November 1982
Resolved 2 November 1982