MAURY USCG vessel records Sign in
← All vessels

JOHN HENRY

JOHN HENRY is a 1980 offshore supply vessel. The Coast Guard has recorded 66 inspections since 1981, most recently in May 2026, along with 44 deficiencies, 1 operational control and 2 casualty investigations between 2016 and 2021.

Records from 1981 to 2026. Most recent: inspection, 27 May 2026.

Built
1980
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8978174 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDH7347
Flag
UNITED STATES
367647270
Maury page id
psix-52346

Inspections, by type

…with no type recorded12
Years with a record 37 calendar years (1981–2026)
The 66 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)100.9 ft × 26.1 ft × 11.7 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)100.9 ft × 26.1 ft × 11.7 ft
ITC tonnagegross 208 / net 62
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portLOS ANGELES, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
208 - Convention (Subpart B), Gross Ton
62 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH7347MMSI 367647270 · active · compulsorily equipped · granted 14 November 2024, expires 14 November 2034
WDH2293MMSI 367596120 · expired · compulsorily equipped · granted 19 November 2013, cancelled 20 January 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDF5512MMSI 367464080 · expired · voluntarily equipped · granted 19 August 2010, cancelled 24 October 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDF4849MMSI 367456510 · expired · voluntarily equipped · granted 10 June 2010, cancelled 15 August 2020 · licensed under a name not among this hull’s recorded names (not shown)
WDC2545MMSI 366994580 · expired · compulsorily equipped · granted 1 December 2004, cancelled 31 January 2015 · licensed under a name not among this hull’s recorded names (not shown)
WCV3170MMSI 338057000 · cancelled · compulsorily equipped · granted 29 April 1998, cancelled 17 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
WYQ8137MMSI not assigned · expired · compulsorily equipped · granted 1 March 1995, cancelled 7 May 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 66

27 May 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8295029
23 June 2025 Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8076529
10 June 2025 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063097
27 September 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8010311
20 June 2024 Annual Inspection · Cargo Tank Internal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7856062
18 September 2023 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7765717
6 June 2023 Internal Structural Exam · Annual Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7680586
12 January 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620617
30 August 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7473758
10 August 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284946
17 June 2021 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7406130
9 April 2021 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7172310
6 August 2019 Examination of Repairs · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6775333
24 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6769514
3 July 2019 Uninspected Other
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6728852
6 May 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638105
29 December 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6603853
7 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385221
4 October 2017 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6262526
31 May 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6143971
3 January 2017 Inclining Experiment · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084388
7 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6054220
20 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829473
11 September 2015 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5222741
26 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4232167
17 January 2012 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4225730
14 February 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3946021
20 February 2009 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3424947
14 November 2008 Deficiency Check · Administrative Inspection · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3368444
19 February 2008 Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3149842
21 February 2006 Ballast Water Examination · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2588938
10 January 2005 In-Service Inspection · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2272287
9 November 2004 Internal Structural Exam · Hull Examination · Examination of Repairs · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2237872
5 October 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1352348
22 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402793
14 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473431
30 September 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1388389
6 May 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383540
26 March 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1374576
29 January 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880690
20 October 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412881
5 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 655366
3 July 1995 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1182199
28 June 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 15000
3 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454175
7 April 1994 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469426
10 November 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 833189
15 April 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422224
28 April 1992 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1271013
5 September 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1245420
23 May 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 928285
25 May 1990 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 914782
22 June 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044760
28 November 1988 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1206148
23 June 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 894010
26 June 1987 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1014411
9 July 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1292795
22 January 1986 Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 997776
11 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1286607
9 July 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281136
29 July 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963638
29 July 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973421
18 January 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970603
2 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971372
5 August 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276539
3 August 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276063

Deficiency record · 44

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2026 Resolved
S and L, if 1.5 inch diameter fire hose is used each length of hose must be lined commercial fire hose that conforms to UL 19 or Federal Specification ZZ H-451E. MI observed fire hoses did not have UL 19 rating. Provide documentation for current fire hose rating or install UL 19 rated fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 1 June 2026
Resolution: Operator provided imagery showing purchase and install of new UL 19 rated fire hoses.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 May 2026 Resolved
The weatherdeck on a flush deck vessel must be watertight. MI observed main deck Port and STBD soft patches above Engine Room were not watertight. Make main deck soft patches watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 1 June 2026
Resolution: Operator provided imagery showing the main deck soft patches were re-sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 June 2024 Resolved
A vessel on an international voyage subject to SOLAS must meet the requirements of subchapter W. Each liferaft must be arranged for float-free launching. Vessels' hydrostatic release unit is expired. Vessel restricted from international voyage. 46 CFR 180.10 46 CFR 199.130(c)(7)
Action required: 702 - Prior to embarking on international voyage
Due 20 July 2024
Resolved 24 June 2024
Resolution: Hydrostatic release unit replaced.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 June 2024 Resolved
A vessel which complies with the requirements in subchapter S of this chapter, must have stability details on the vessel's Certificate of Inspection, a stability letter, or an approved stability booklet. Trim and Stability Booklet, allows for 8 passengers and 4 crew, while vessel's COI permits 14 passengers and 4 crew. Vessel restricted to 8 passengers and 4 crew until a new approved Trim and Stability booklet is provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 22 July 2024
Resolution: Vessel did not update their Stability Booklet. COI has been amended to reflect the current passenger allowance of 8 listed in their Stability Booklet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023 Resolved
All electrical installations shall be such to the satisfaction of the Officer in Charge, Marine Inspection. MI Observed break panel with unsatisfactory latch. 46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 8 June 2023
Resolution: MI attest to proper repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 August 2021 Resolved
Adequate emergency lighting automatically actuate upon failure of the main lighting system shall be fitted along the route of escape in any vessel with lounge areas below the main deck. Emergency light in the lower salon, part of the emergency egress route, was not functioning. Repair E-lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2021
Resolved 13 August 2021
Resolution: Emergency light replacerd and operating as should.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 May 2019 Resolved
Provide proof of MSC review and Stability letter from Incline stability exam conducted on 07FEB2017. The vessel's deck cargo load is reduced to 53 long tons with its vertical center of gravity not to exceed three feet above the cargo deck until the receipt of a new Stability Letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 24 October 2019
Resolution: ABS Houston issued booklet
Engineering › Pressure Vessel › Piping
Issued 7 May 2018 Resolved
Replace ruptured non-metallic flexible piping on pressure vessel in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 8 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 May 2018 Resolved
Emergency lighting in crew accomodation space below main deck was not funbctional.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 May 2018
Resolved 7 May 2018
Resolution: Deficiency corrected on the spot to the satisfaction of the attending Coast Guard Marine Inspector.
Communications › Public Address System › Loudspeaker
Issued 31 May 2017 Resolved
Install a functional fixed public address system below the main deck to be heard throughout all accommodation spaces, per 46 CFR 184.610 & 184.115(b)
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: See Narrative
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 May 2017 Resolved
Provide smoke detectors for all below deck accommodation spaces.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 31 May 2017
Resolution: See Narrative
Documentation › Certificates/Documents › Stability Letter
Issued 16 February 2017 Resolved
Provide proof of MSC Review and Stability Letter from Incline Stability Exam conducted on 9 February 2017. The vessel's deck cargo load is reduced to 53 long tons with it's vertical center of gravity not to exceed 3 feet above the cargo deck until the receipt of a new Stability Letter.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 24 October 2019
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 April 2016 Resolved
Pvovide adequate lighting in accomidations
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: lighting added
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 April 2016 Resolved
repair junction box in refer.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2016 Resolved
provide bulbs in accomidation racks and one on main deck
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: repaired
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 17 January 2012 Resolved
Vsl did not have a copy of the Inland Navigation Rules on board and the copy of 33 CFR onboard was out of date.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Navigation › Piloting/Steering › Marine Charts
Issued 17 January 2012 Resolved
Vsl's charts were not updated with the Local Broadcast Notice to Mariners.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 17 January 2012 Resolved
Vsl had outdated Tide/Tide Current Tables
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Lifesaving › Lifefloat › Float Free
Issued 17 January 2012 Resolved
Life Floats were arranged in such a way that they would not float free due to line tangling.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 January 2012 Resolved
Line on lifebouy was not of an approved type
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 January 2012 Resolved
Vsl's name and port was not present on lifebouys and retro tape needed to be replaced
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 January 2012 Resolved
Retro tape was worn and needed to be replaced
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Communications › Radio Communications › EPIRB
Issued 17 January 2012 Resolved
Hydrostatic release for the EPIRB was not installed correctly and was expired
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 January 2012 Resolved
Emergency light in galley did not work due to installation of wrong voltage of light bulb
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 January 2012 Resolved
Outlet box in the engine room was missing a waterproof cover over the top electrical outlets
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 January 2012 Resolved
The electrical panel door in the pilot house was loose and held shut by a role of paper towels
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 January 2012 Resolved
Dead end wiring under pilot house control panel needs to be removed
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 January 2012 Resolved
A outlet box located on the pilot house control panel was hard wired and plugged into another outlet box. Outlet box needs to be removed or installed properly
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 17 January 2012 Resolved
Draft markings needed to be repainted with a contrasting color
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2012
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 January 2012 Resolved
Vessel had no proof of annual DAPI audit on board
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 February 2012
Resolved 2 February 2012
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2012 Resolved
Not Under Command lights had house hold bulbs installed inplace of approved vertical fiament types
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2012
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 17 January 2012 Resolved
Metal garbage cans did not have metal lids
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Construction/Loadline › Hull › Hull Plating
Issued 17 January 2012 Resolved
Water was discovered on small portions of the sideshell just below the waterline behind a wall in the crew cabin on the starboard side. Vessel rep was required to dye pen the area to see if any cracks or pin holes were present.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 17 January 2012 Resolved
Rudder direction (port and Starboard) needs to be labeled on Aux steering to indicate that the rudder will turn in the opposite direction as the wheel due to the arrangement of the steering system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Documentation › Markings/Placards › Lifejacket Placard
Issued 17 January 2012 Resolved
Vsl only had a donning placard for one of the three types of PFDs onboard
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 January 2012 Resolved
Refrigerator door had no locking mechanism or means of keeping the door from opening while underway
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 17 January 2012 Resolved
Replace exhaust vent cover gaskets or bend covers to ensure a propper fit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Fire Fighting › Ventilation Systems › Ducts
Issued 17 January 2012 Resolved
Lable ventilation ducts "close in case of fire"
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 January 2012 Resolved
Repack or tighten tail shafts to reduce the flow of water entering the bilge
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 January 2012 Resolved
Drills were not conducted to give the crew time to better train and better prepare. Drills will be conducted to the satisfaction of the attending MI during deficiency follow up examination
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 January 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 14 February 2011 Resolved
P/H electrical engine shutdowns were being converted to an air system. Engines operated normally but crew had to secure engines locally.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2011
Resolution: [name withheld] reported P/H engine shutdowns operating normally.
Lifesaving › Hand Flares › Quantity
Issued 14 February 2011 Resolved
Vessel had only 3 red and 3 orange flares.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 February 2011
Resolution: Capt provided documentation for the addition of 3 additional red and orange flares.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 November 2008 Resolved
Man overboard drill was unsatisfactorily and unsuccessfully completed. Train crew and conduct proper drill to CG marine inspector approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2008
Resolution: Drill was competently completed.
Engineering › Steering Gear System › Rudder
Issued 19 November 2008 Resolved
Rudder was striking rudder stop. Reconfigure system to align properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 November 2008
Resolution: Rudder stop adjusted and steering system works properly.

Casualty record · 2

7 December 2016Routine · role: Involved in a Marine Casualty · activity 6054220
9 April 2021Routine · role: Involved in a Marine Casualty · activity 7172310
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.