MAURY USCG vessel records
← All vessels

JOHN HENRY

Built
1980
Last inspected
27 May 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8978174
WDH7347
Flag
UNITED STATES
Maury page id
psix-52346

Documentation record

Registered dimensions (L × B × D)100.9 ft × 26.1 ft × 11.7 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)100.9 ft × 26.1 ft × 11.7 ft
ITC tonnagegross 208 / net 62
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
208 - Convention (Subpart B), Gross Ton
62 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 23 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 23

27 May 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8295029
23 June 2025 Drydock Extension · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8076529
10 June 2025 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8063097
27 September 2024 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8010311
20 June 2024 Annual Inspection · Cargo Tank Internal
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7856062
18 September 2023 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7765717
6 June 2023 Internal Structural Exam · Annual Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7680586
12 January 2023 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7620617
30 August 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7473758
10 August 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7284946
17 June 2021 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7406130
9 April 2021 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7172310
6 August 2019 Examination of Repairs · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6775333
24 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6769514
3 July 2019 Uninspected Other
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6728852
6 May 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6638105
29 December 2018 Excursion Permit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6603853
7 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6385221
4 October 2017 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6262526
31 May 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6143971
3 January 2017 Inclining Experiment · In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084388
7 December 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6054220
20 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5829473

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2026 Resolved
S and L, if 1.5 inch diameter fire hose is used each length of hose must be lined commercial fire hose that conforms to UL 19 or Federal Specification ZZ H-451E. MI observed fire hoses did not have UL 19 rating. Provide documentation for current fire hose rating or install UL 19 rated fire hose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 1 June 2026
Resolution: Operator provided imagery showing purchase and install of new UL 19 rated fire hoses.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 May 2026 Resolved
The weatherdeck on a flush deck vessel must be watertight. MI observed main deck Port and STBD soft patches above Engine Room were not watertight. Make main deck soft patches watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2026
Resolved 1 June 2026
Resolution: Operator provided imagery showing the main deck soft patches were re-sealed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 June 2024 Resolved
A vessel on an international voyage subject to SOLAS must meet the requirements of subchapter W. Each liferaft must be arranged for float-free launching. Vessels' hydrostatic release unit is expired. Vessel restricted from international voyage. 46 CFR 180.10 46 CFR 199.130(c)(7)
Action required: 702 - Prior to embarking on international voyage
Due 20 July 2024
Resolved 24 June 2024
Resolution: Hydrostatic release unit replaced.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 20 June 2024 Resolved
A vessel which complies with the requirements in subchapter S of this chapter, must have stability details on the vessel's Certificate of Inspection, a stability letter, or an approved stability booklet. Trim and Stability Booklet, allows for 8 passengers and 4 crew, while vessel's COI permits 14 passengers and 4 crew. Vessel restricted to 8 passengers and 4 crew until a new approved Trim and Stability booklet is provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 July 2024
Resolved 22 July 2024
Resolution: Vessel did not update their Stability Booklet. COI has been amended to reflect the current passenger allowance of 8 listed in their Stability Booklet.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2023 Resolved
All electrical installations shall be such to the satisfaction of the Officer in Charge, Marine Inspection. MI Observed break panel with unsatisfactory latch. 46CFR183.01-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2023
Resolved 8 June 2023
Resolution: MI attest to proper repair.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 August 2021 Resolved
Adequate emergency lighting automatically actuate upon failure of the main lighting system shall be fitted along the route of escape in any vessel with lounge areas below the main deck. Emergency light in the lower salon, part of the emergency egress route, was not functioning. Repair E-lighting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 August 2021
Resolved 13 August 2021
Resolution: Emergency light replacerd and operating as should.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 May 2019 Resolved
Provide proof of MSC review and Stability letter from Incline stability exam conducted on 07FEB2017. The vessel's deck cargo load is reduced to 53 long tons with its vertical center of gravity not to exceed three feet above the cargo deck until the receipt of a new Stability Letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 24 October 2019
Resolution: ABS Houston issued booklet
Engineering › Pressure Vessel › Piping
Issued 7 May 2018 Resolved
Replace ruptured non-metallic flexible piping on pressure vessel in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2018
Resolved 8 May 2018
Resolution: Deficiency corrected to the satisfaction of the attending Coast Guard Marine Inspector.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 May 2018 Resolved
Emergency lighting in crew accomodation space below main deck was not funbctional.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 7 May 2018
Resolved 7 May 2018
Resolution: Deficiency corrected on the spot to the satisfaction of the attending Coast Guard Marine Inspector.
Communications › Public Address System › Loudspeaker
Issued 31 May 2017 Resolved
Install a functional fixed public address system below the main deck to be heard throughout all accommodation spaces, per 46 CFR 184.610 & 184.115(b)
Action required: 705 - Other - as specified
Due 16 June 2017
Resolved 15 June 2017
Resolution: See Narrative
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 31 May 2017 Resolved
Provide smoke detectors for all below deck accommodation spaces.
Action required: 705 - Other - as specified
Due 31 May 2017
Resolved 31 May 2017
Resolution: See Narrative
Documentation › Certificates/Documents › Stability Letter
Issued 16 February 2017 Resolved
Provide proof of MSC Review and Stability Letter from Incline Stability Exam conducted on 9 February 2017. The vessel's deck cargo load is reduced to 53 long tons with it's vertical center of gravity not to exceed 3 feet above the cargo deck until the receipt of a new Stability Letter.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 24 October 2019
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 April 2016 Resolved
Pvovide adequate lighting in accomidations
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: lighting added
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 April 2016 Resolved
repair junction box in refer.
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: repaired
Electrical › Lighting (service) › Lighting Fixture
Issued 20 April 2016 Resolved
provide bulbs in accomidation racks and one on main deck
Action required: 705 - Other - as specified
Due 21 May 2016
Resolved 21 May 2016
Resolution: repaired

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.