MAURY USCG vessel records Sign in
← All vessels

NOBLE EDDIE PAUL

NOBLE EDDIE PAUL is a 1975 mobile offshore drilling unit. The Coast Guard has recorded 99 inspections since 1980, most recently in June 2006, along with 193 deficiencies.

Records from 1980 to 2006. Most recent: inspection, 19 June 2006.

Built
1975
Last inspected
19 June 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753603 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRW2663
Flag
LIBERIA
—
Maury page id
psix-52360

Inspections, by type

…with no type recorded38
Years with a record 27 calendar years (1980–2006)
The 99 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1983 - Convention (Subpart B), Net Ton
6613 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 99

19 June 2006 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2685119
29 November 2005 Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2542370
17 November 2004 Periodic Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2243095
14 May 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2106700
30 October 2003 Annual Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1938999
24 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762202
24 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1762222
3 March 2003 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1752056
12 December 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1716321
18 October 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1692243
15 July 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646351
18 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075882
17 October 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1075928
15 August 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073167
16 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1065370
27 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054230
2 December 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809842
27 October 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1395292
31 March 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 783603
10 March 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804432
10 December 1998 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1463428
23 November 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806921
30 October 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434635
31 October 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445132
7 August 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765112
19 July 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1087135
15 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 197084
18 June 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 883297
8 February 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 874911
17 December 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1191667
13 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880122
8 November 1995 COI Inspection · Hull Examination · Construction Oversight
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434245
16 August 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 752213
7 August 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 204224
1 February 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1417737
16 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154833
5 July 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1171750
15 April 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409112
28 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163428
1 February 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465771
27 January 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161911
23 March 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447230
10 March 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1359488
18 February 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1143684
25 January 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 825721
12 August 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266582
12 May 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267358
12 March 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257759
27 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1265885
11 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 945730
5 December 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1257058
18 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1243755
16 March 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997404
7 March 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219701
30 January 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 921997
18 January 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927842
17 January 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1242270
15 November 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930394
7 November 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233399
25 January 1990 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 911826
16 June 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1035872
24 April 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205965
25 January 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1206158
6 December 1988 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 896718
10 November 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 894819
13 October 1988 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886803
8 August 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343405
8 June 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209136
17 May 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350144
26 April 1988 Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347173
7 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030540
23 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985289
18 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1023916
13 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322672
16 December 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009827
7 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313618
27 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019087
21 November 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312809
9 July 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993826
30 May 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995031
18 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299202
4 April 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987315
6 February 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307655
2 October 1985 Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 992686
13 September 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1300601
11 June 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1291308
10 May 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978168
28 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974916
28 December 1984 Re-Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307072
2 February 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970727
12 January 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971282
10 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276402
19 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970292
2 March 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275633
23 February 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273854
21 December 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273950
27 August 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972069
30 January 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281509
30 March 1980 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969838

Deficiency record · 193

Construction/Loadline › Hull › Hull Plating
Issued 29 November 2005 Resolved
Complete SEILOD Phase II NLT 28 Feb 06
Due 28 February 2006
Resolved 11 March 2011
Resolution: Closed deficiency that was inadvertently never updated.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 November 2004 Resolved
Complete inspection of and verify proper installation of explosion proof electrical cable seals/penetrations in hazardous locations. Repair seals identified by the cg inspector. Provide statement of fact, from the rig OIM, that the work has been completed.
Condition: Improper Installation
Due 12 December 2004
Resolved 30 November 2004
Resolution: Received signed statement from the vessels OIM, [name withheld] that the deficiency had been corrected.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 17 November 2004 Resolved
During next rig shut down, prove proper operation of the engine room CO2 system, rig shut down pressure switch and provide signed statement of fact from the OIM to the [name withheld] prior to the next rig move.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 December 2004
Resolution: Received signed verification from [name withheld] that the test had been satisfactorily completed.
Navigation › Collision/Grounding Avoidance
Issued 20 November 2003 Resolved
Replace obstruction light flasher controller to a 60 flash per minute characteristic. LEGACY COMPONENT DESC: Obstruction lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 December 2003
Resolved 22 December 2003
Construction/Loadline › Structures › Deck Plating
Issued 30 October 2003 Resolved
Complete Phase II of SEILOD at next rig move. LEGACY COMPONENT DESC: SEILOD Phase II
Action required: 705 - Other - as specified
Due 30 January 2004
Resolved 17 November 2004
Resolution: Verified by [name withheld]
Lifesaving › Lifeboat
Issued 27 December 2002 Resolved
Provide survey report for "excessive sagging"on #2 lifeboat. This was identified in Alexander-Ryan survey dated 17SEP02. Lifeboat had wood wedge installed so throttle could be fully operational. LEGACY COMPONENT DESC: Hull
Due 27 February 2003
Resolved 20 February 2003
Resolution: Life boat sent to Alexander/Ryan for repairs and re-installed onboard Noble Eddie Paul 19FEB 03.
Construction/Loadline
Issued 27 December 2002 Resolved
Crop and renew bulkhead where wasted through between mud pits and pump room.
Due 27 January 2003
Resolved 24 January 2003
Lifesaving
Issued 17 October 2001 Resolved
UPDATE MUSTER LIST TO CLEARLY SHOW "PERSONS IN CHARGE" OF LIFEBOATS IN ACCORDANCE WITH 46 CFR 109.323.
Condition: Unknown
Due 17 November 2001
Resolved 7 March 2002
Documentation
Issued 17 October 2001 Resolved
PROVIDE PROOF OF USCG APPROVAL OF OPERATIONS MANUAL REV. 2. CURRENT APPROVAL INDICATES ABS APPROVAL ONLY.
Condition: Unknown
Due 17 November 2001
Resolved 30 December 2002
Documentation
Issued 17 October 2001 Resolved
PROVIDE UPDATED FIRE AND SAFETY PLANS BEARING "ORIGINAL" CG APPROVAL STAMP.NEW PLANS MUST BE SUBMITTED TO THE OCS BRANCH OF MSO NEW ORLEANS AND CONTAIN IMO SYMBOLOGY AS REQUIRED BY 46 CFR 109.563.
Condition: Unknown
Due 17 November 2001
Resolved 7 March 2002
Lifesaving
Issued 17 October 2001 Resolved
ADJUST AND PROVE LIMIT SWITCHES ON LIFEBOATS 2 AND 3.
Condition: Unknown
Due 30 October 2001
Resolved 19 November 2001
Deck/Cargo
Issued 17 October 2001 Resolved
PROVIDE PROOF OF ANNUAL CRANE EXAMS FOR PORT AND PORT AFT CRANES.
Condition: Unknown
Due 22 October 2001
Resolved 19 November 2001
Documentation
Issued 17 October 2001 Resolved
UPDATE CG LOG BOOK TO INCLUDE A METHOD TO TRACK EACH INDIVIDUAL BOAT ACTIVITIES AS REQUIRED BY 109.213(D). PROVIDE TRACEABLE METHOD TO VERIFY WHEN BOATS ARE OPERATED IN WATER WITH SPRINKLER SYSTEM TEST.
Condition: Unknown
Due 17 November 2001
Resolved 7 March 2002
Lifesaving
Issued 17 October 2001 Resolved
ENSURE LIFEBOAT ASSIGNMENTS ARE MADE TO INDICATE PRIMARY ABANDONMENT STATIONS ON ONE SIDE OF VESSEL AND ALTERNATE STATION IN DIFFERENT LOCATION.
Condition: Unknown
Due 17 November 2001
Resolved 19 November 2001
Lifesaving
Issued 17 October 2001 Resolved
PROVE PURGE SYSTEM OPERATION AND PROTECTION ON THE FOLLOWING; 2 EA GAS DETECTION JUNCTION BOXES, VISUAL LOGGER MONITOR ENCLOSURE, DERRICK VIDEO ENCLOSURE AND DRILL GRAPH ENCLOSURE.
Condition: Unknown
Due 30 October 2001
Resolved 7 March 2002
Lifesaving
Issued 27 October 1999 Resolved
#1 STBD L/B LIMIT SWITCH TRIPPED WITHIN INCHES OF DAVIT STOP. LIMIT SWITCHADJUSTED TO 10-12 INCHES FROM DAVIT STOP DURING COURSE OF INSPECTION.
Condition: Unknown
Due 29 October 1999
Resolved 29 October 1999
Electrical
Issued 10 December 1998 Resolved
REMOVE WIRES RUNNING THROUGH LOUVERS IN EMERGENCY GENERATOR SPACE SO LOUVERS CAN BE PROPERLY CLOSED AND NATURAL VENTILATION CAN BE CUT OFF TO SPACE IN THE EVENT OF A FIRE.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
SECURELY MOUNT 3 JUNCTION BOXES AND PLUG CIRCULAR JUNCTION BOX IN DOG HOUSEON DRILL FLOOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
PROVIDE PROPER MEANS TO ENCLOSE D79 MOTOR DRAWWORKS VENTILATION EXPANSION DUCT, SO AIR CANNOT ESCAPE OUT OF EXHAUST AND OUT ON DRILL FLOOR.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
SECURE JUNCTION BOX IN DRILLER'S SHACK FOR DRILLING RECORDER.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Fire Fighting
Issued 10 December 1998 Resolved
REPAIR/REPLACE STEEL MOLDING AROUND UPPER PORTION OF BULKHEADS ON DECK LEVEL 3 IN ORDER TO RETAIN STRUCTURAL FIRE PROTECTION INTEGRITY FOR ADJACENT SPACES.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Lifesaving
Issued 10 December 1998 Resolved
PERMANENTLY REPAIR HOLES IN BULKHEAD BETWEEN MUD PIT ROOM AND MUD PUMP ROOMSO AS TO NOT COMPROMISE GAS TIGHT INTEGRITY BETWEEN BOTH SPACES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Fire Fighting
Issued 10 December 1998 Resolved
CLEAN OUT INTERNATIONAL SHORE CONNECTION, BLANK, BOLT AND SECURE TO SPOOL.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Lifesaving
Issued 10 December 1998 Resolved
PROVIDE PROPER MEANS FOR SELF-CLOSING DOORS IN MUD PIT ROOM TO CLOSE AND SEAL UNDER OWN DEVICE PRIOR TO DOGS BEING UTILIZED.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
SECURE MUD LEVEL PIT VOLUME TOTALIZERS PROPERLY IN MUD PIT ROOM.
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Lifesaving
Issued 10 December 1998 Resolved
REPLACE BATTERY FOR LIFEBUOY LIGHT #3.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Electrical
Issued 10 December 1998 Resolved
ENSURE MUD PIT AGITATORS ARE NOT PAINTED OVER SO AS TO ENSURE EXPLOSION- PROOF INTEGRITY OF MOTORS ARE NOT COMPROMISED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
PROPERLY MOUNT WIMCO HIGH LEVEL INDICATOR BOX IN MUD PIT ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 January 1999
Resolved 1 February 1999
Electrical
Issued 10 December 1998 Resolved
PROVIDE CHICO/STUFFING FOR GENERAL ALARM BELL ELECTRICAL FITTING IN MUD PITROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Electrical
Issued 10 December 1998 Resolved
SECURE OVERHEAD LIGHTS PROPERLY IN MUD PIT ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Electrical
Issued 30 October 1997 Resolved
REPAIR AS ORIGINAL HOT WATER TEMPERATURE SHUT-DOWN FOR EMERGENCY GENERATOR.CONDUCT SATISFACTORY TEST OF AUTO BUS TRANSFER.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Electrical
Issued 30 October 1997 Resolved
MAKE REPAIRS TO TOTAL RIG SHUT-DOWN SYSTEM. CONDUCT SATISFACTORY TEST OF SYSTEM.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Fire Fighting
Issued 30 October 1997 Resolved
ADJUST INTERIOR DOORS TO HOUSE STAIRWELLS AND GALLEY ENTRANCE FOR PROPER SELF-CLOSURE AS NECESSARY.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 30 October 1997 Resolved
PROPERLY CONNECT COMPRESSED AIR BOTTLES TO MANIFOLD IN LIFEBOATS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Fire Fighting
Issued 30 October 1997 Resolved
ENSURE THOROUGH TRAINING OF FIRE TEAM MEMBERS IN CLASSES OF FIRES, PROPER EXTINGUISHING AGENTS AND TECHNIQUES, AND SCBA USAGE.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 31 October 1996 Resolved
MAKE REPAIRS TO PORT CRANE LADDER.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Fire Fighting
Issued 31 October 1996 Resolved
MAKE REPAIRS TO FIREFIGHTING SYSTEMS IN ACCORDANCE WITH FIREMASTER REPORT, DATED 17OCT96.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Electrical
Issued 31 October 1996 Resolved
TEST AUTO BUS TRANSFER, OVERSPEED SHUTDOWN AND LOW LUBE OIL PRESSURE SHUTDOWN ON EMERGENCY GENERATOR.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Electrical
Issued 31 October 1996 Resolved
TEST REVERSE POWER RELAYS ON ALL GENERATORS.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS STATEMENT OF FACT FOR TESTING DECK CRANES.
Condition: Unknown
Due 6 December 1995
Resolved 24 January 1996
Construction/Loadline
Issued 8 November 1995 Resolved
CORRECT DRAFT MARKS AS PER ABS RECOMMENDATION.
Condition: Unknown
Due 6 December 1995
Resolved 24 January 1996
Accommodation/Occupational Safety
Issued 8 November 1995 Resolved
REPLACE ALL 6 BULK TANK RELIEF VALVES WITH MAX SETTINGS OF 40 PSI AND SUBMIT MANUFACTURER CERTIFICATES.
Condition: Unknown
Due 6 December 1995
Resolved 24 January 1996
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS OPERATIONS MANUAL FOR APPROVAL AFTER EXAMINED BY MARINE SAFETY CENTER.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS ABS REPORTS OF ALL STEEL RENEWAL, REPAIRS, HYDROSTATIC TESTING OF SPONSON TANKS AND OTHER FUNCTIONAL TESTS WHILE VESSEL WAS IN SHIPYARD.
Condition: Unknown
Due 6 December 1995
Resolved 23 January 1996
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS U-1A MANUFACTURER DATA REPORT AND DESIGN PLANS FOR THREE NEW PRESSURE VESSELS INSTALLED ON BOARD.
Condition: Unknown
Due 6 December 1995
Resolved 24 January 1996
Fire Fighting
Issued 8 November 1995 Resolved
SUBMIT TO PATMS UPDATED FIRE CONTROL PLAN.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS COPY OF FINAL STABILITY LETTER.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Documentation
Issued 8 November 1995 Resolved
SUBMIT TO PATMS COPY OF FINAL ABS LOAD LINE CERTIFICATE.
Condition: Unknown
Due 8 November 1995
Resolved 8 November 1995
Construction/Loadline
Issued 1 February 1995 Resolved
SUBMIT TO MSO PORT ARTHUR, ABS SURVEYOR REPORT OF INSPECTION FINDINGS OF ALL THREE SPUD CAN CRITICAL CONNECTIONS AND REPAIRS PERFORMED.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 1 February 1995 Resolved
SUBMIT TO MSO PORT ARTHUR, NDT/REPAIR REPORT OF ALL THREE SPUD CANS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Documentation
Issued 1 February 1995 Resolved
COMPLETE CERTIFICATION OF INSPECTION PRIOR TO VESSEL LEAVING CAMERON, LA SHIPYARD FOR HULL MODIFICATION AND PRIOR TO LEAVING PATMS ZONE AND OR NEXT DRILLING OPERATIONS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 5 July 1994 Resolved
UPON COMPLETION OF OF MODIFICATION AVAILABILITY COMMENCING APPROX SEP'94 INCAMERON, LA AND PRIOR TO ANY RIG MOVEMENT FROM THAT PORT COMPLETE LOWER HULL PORTION OF DRYDOCKING CREDITED AS OF 01 FEB 94.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 15 April 1994 Resolved
COMPLETE LOWER HULL EXAM AS PER CHILES OFFSHORE PROPOSAL DATED 31JAN94.
Condition: Unknown
Due 15 April 1994
Resolved 15 April 1994
Construction/Loadline
Issued 1 February 1994 Resolved
COMPLETE UPPER HULL EXAM AS PER CHILES OFFSHORE PROPOSAL DATED 31JAN94.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Construction/Loadline
Issued 1 February 1994 Resolved
GAUGE MUD PIT/MUD PUMPROOM BULKHEAD.
Condition: Unknown
Due 1 February 1994
Resolved 1 February 1994
Fire Fighting
Issued 23 March 1993 Resolved
INSTALL VENTILATION CLOSURES FOR ENGINEROOM VENTS TO BE MANUALLY CLOSED IN THE EVENT OF OPERATION OF THE CO2 FIXED SYSTEM IN ENGINEROOM.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Fire Fighting
Issued 23 March 1993 Resolved
INSTALL A-60 INSULATION ON BULKHEAD BETWEEN ENGINEROOM AND CO2 STORAGE SPACE AS PER MSC-2 APPROVAL LETTER OF 15 APR 91 SERIAL: M-10252 COMMENT 7.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Lifesaving
Issued 10 March 1993 Resolved
TEST BULK TANK RELIEF VALVES TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Lifesaving
Issued 10 March 1993 Resolved
PRIOR TO DRILLING OPERATIONS, CONDUCT FIRE AND BOAT DRILL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1993
Resolved 1 April 1993
Deck/Cargo
Issued 18 February 1993 Resolved
OFFICE ISSUE: HAVE ABS OR NCB WITNESS CRANE WEIGHT TEST FOR REPAIRS DONE TOCRANE BOOMS AND SUBMIT TO [name withheld], TEXAS CERTIFICATES OF THE TEST.
Condition: Unknown
Due 16 March 1993
Resolved 16 March 1993
Deck/Cargo
Issued 12 August 1992 Resolved
PROVIDE REPAIR PROPOSAL AND MAKE REPAIRS TO CRANES AS NOTED IN DEFICIENCIESON ABS SURVEY REPORT DATED 12MAY92._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Documentation
Issued 12 May 1992 Resolved
PROVIDE SURVEY REPORT ON ANNUAL CRANE INSPECTION CONDUCTED BY ABS ON THIS DATE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Construction/Loadline
Issued 12 May 1992 Resolved
MAKE REPAIRS TO HOLES IN AFT BULKHEAD (MUD PUMP ROOM SIDE) OF MUD PIT ROOM.REPLACE BROKEN LIGHTS IN MUD PUMP ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Engineering
Issued 12 May 1992 Resolved
INSTALL PROPER FLAME SCREENS IN ALL FUEL OIL TANK VENTS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Documentation
Issued 12 May 1992 Resolved
PROVIDE ON BOARD REVISION 6 TO OPERATING MANUAL AND APPROVED REVISED FIRE CONTROL AND SAFETY PLAN. PROVIDE GMSC LETTER DATED 28JUN91 ON APPROVAL OF HAZARDOUS LOCATION PLAN._x001C_ _x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Accommodation/Occupational Safety
Issued 12 May 1992 Resolved
REPLACE LEAKING RELIEF VALVE ON DRILL FLOOR AIR RECEIVER AND ENSURE ASME APPROVED AND NOT TO EXCEED MAWP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Accommodation/Occupational Safety
Issued 12 May 1992 Resolved
PROVIDE ASME APPROVED RELIEF VALVE ON FWD FRESH WATER PRESSURE TANK AND ENSURE SETTING IS FOR 100 PSI OR LESS. PROVIDE ASME APPROVED RELIEF VALVE ON FWD HOT WATER HEATER SET AT 100 PSI OR LESS AND 210 DEGREES F. OR MAKE BOTH PRESSURE VESSELS AVAILABLE FOR INTERNAL INSPECTION._x001C_
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Documentation
Issued 16 March 1991 Resolved
PERSON IN CHARGE IS REQUIRED TO CONDUCT A FIRE AND BOAT DRILL IAW 46 CFR 109.213 AND .215 WITHIN THREE (3) HOURS OF GETTING UNDER TOW AND LOG THE SAME._x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Construction/Loadline
Issued 16 March 1991 Resolved
PROVIDE ABS SURVEY REPORT ON REPAIRS MADE TO LEG TO CAN CONNECTIONS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Navigation
Issued 16 March 1991 Resolved
MAKE PROPER REPAIRS TO OR PROVIDE ON BOARD AN INTERNATIONAL FOG SIGNAL IN ACCORDANCE WITH COLREGS. (1 PROLONGED BLAST FOLLOWED BY 3 SHORT BLASTS)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Lifesaving
Issued 16 March 1991 Resolved
PROVIDE ON BOARD 1500 FEET OF LINE FOR ROCKET PROJECTILE LINE THROWING GUN IAW 46 CFR 94.45-15._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Electrical
Issued 16 March 1991 Resolved
PROVIDE ON BOARD APPROVED PLANS FOR THE INSTALLATION OF THE NEW EMERGENCY GENERATOR, SWITCHBOARD, AND DISTRIBUTION WIRING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Electrical
Issued 16 March 1991 Resolved
MAKE THE "RATE MASTER" BOX ON THE AFT STBD BULKHEAD OF THE DRILL FLOOR EXPLOSIONPROOF IAW 46 CFRR 111.105. MAKE ALL E/P TRANSDUCERS EXPLOSIONPROOFOR PROVIDE DOCUMENTATION THAT FITTINGS/TRANSDUCERS ARE INTRINSICALLY SAFE._x001C__x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Lifesaving
Issued 16 March 1991 Resolved
RE-LAY THE WIRE FALLS ON THE PORT 58-MAN LIFEBOAT TO ENSURE PROPER LAYING OF THE FALLS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Fire Fighting
Issued 16 March 1991 Resolved
SUBMIT FOR APPROVAL THE FIXED EXTINGUISHER SYSTEM FOR PAINT LOCKER. PROVIDEB-II PORTABLE EXTINGUISHER FOR PAINT LOCKER. UPDATE HAZARDOUS LOCATION PLANREFLECTING THE PAINT LOCKER LOCATION._x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Electrical
Issued 16 March 1991 Resolved
MAKE PROPER REPAIRS TO OR PROVIDE ADDITIONAL GENERAL ALARM BELLS TO PROVIDE100% COVERAGE THROUGHOUT RIG IAW 46 CFR 113.25 AND PROVIDE FLASHING RED LIGHTS IAW 46 CFR 113.25-10._x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Documentation
Issued 16 March 1991 Resolved
CALCULATE AND SUBMIT FOR APPROVAL (PROVIDE ON BOARD) ALL STRUCTURAL MODIFICATIONS AND THEIR EFFECT ON THE VESSELS STABILITY AND LOADLINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Electrical
Issued 16 March 1991 Resolved
MAKE THE JUNCTION BOX FORWARD OF THE SHALESHAKER AREA EXPLOSIONPROOF IAW 46 CFR 111.105-9 AND 111.105-9(A)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Documentation
Issued 16 March 1991 Resolved
SUBMIT FOR APPROVAL APPLICABLE PAGE CHANGES/REVISIONS TO THE OPERATIONS MANUAL TO INCLUDE APPROVAL OF THE FIRE CONTROL PLAN, STATION BILL, AND THE SAFETY PLAN FOR REVIEW._x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Documentation
Issued 16 March 1991 Resolved
MAINTAIN LOGBOOK ENTRIES IN ACCORDANCE WITH 46 CFR 109.433 AND 46 CFR 109 SUBPART B._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Documentation
Issued 16 March 1991 Resolved
PROVIDE ON BOARD THE FOLLOWING APPROVED PLANS: MODIFICATIONS TO FIREMAIN SYSTEM, FIXED CO2 IN ENGINEROON, KOOMEY UNIT, MUD SYSTEM, P/S 58MAN LIFEBOAT DAVIT INSTALLATIONS, HAZARDOUS LOCATIONS, MSD INSTALLATION, SHALE SHAKER INSTALLATION, AND EMERGENCY GENERATOR INSTALLATION._x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Accommodation/Occupational Safety
Issued 16 March 1991 Resolved
PROVIDE A RELIEF VALVE FOR THE NO.1 HOT WATER HEATER IN ACCORDANCE WITH 46 CFR 63.25-3(H)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Documentation
Issued 16 March 1991 Resolved
PROVIDE ON BOARD A MARPOL ANNEX V WASTE MANAGEMENT PLAN AND PLACARDS GOVERNING THE DISCHARGE OF GARBAGE AT SEA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 March 1991
Resolved 16 March 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(2) ON THE B SIDE OF C CHORD; CAN SIDE OF SHEAR PLATE; 5" ACROSS THE TOP AND 3" DOWN SIDE THAT PROPAGATES INTO CAN 1"; IN TOE OF WELD ON CAN SIDE.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(3) ON THE B SIDE OF C CHORD; 8" CRACK IN BUTT WELD ABOVE THE "VD"
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 17 January 1991 Resolved
PROVIDE COPIES OF THE ABS UNDERWATER SURVEY, ALL GAUGINGS TAKEN DURING THE SPECIAL EXAM IN LIEU OF DRYDOCKING, AND ALL NON-DESTRUCTIVE TESTING REPORTSTO THE COGNIZANT OCMI.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(4) ON THE B SIDE OF C CHORD; 1/4" CRACK WHERE LIP OF CAN TIES INTO MAIN GUSSET AND 1" CRACK ON TOP OF CAN NEXT TO LIP WHERE IT MEETS THE MAIN GUSSET.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(5) ON THE D SIDE OF C CHORD; CRACK STARTS AT 6" BELOW THE TOP OF THE GUSSET TO CHORD CONNECTION (VERTICAL) AND CONTINUES DOWN ENTIRE LENGTH ON THE TOE, CHORD SIDE.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(6) ON THE C SIDE OF B CHORD; MAIN GUSSET TO CAN CONNECTION; 4" CRACK IN TOE OF WELD ON GUSSET SIDE WITHIN FIRST 12" FROM THE LIP.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(7) ON THE C SIDE OF D CHORD; ON THE CAN SIDE OF THE SHEAR PLATE TO CAN CONNECTION; 1" CRACK ACROSS THE TOP AND 1" CRACK DOWN THE SIDE.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
MAKE PROPER REPAIRS IN WAY OF THE STARBOARD CAN IN ACCORDANCE WITH THE VESSELS CONSTRUCTION PORTFOLIO IN THE FOLLOWING NOTED AREAS. THE FOLLOWING REQUIREMENTS (H1-H7) REPRESENT THOSE CRACKS TO BE REPAIRED. NOTE: "A" IS THE FORWARD CHORD; "B" STARBOARD; "C" AFT; "D" PORT
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Construction/Loadline
Issued 17 January 1991 Resolved
(1) ON THE C SIDE OF B CHORD CONNECTION; CAN SIDE OF SHEAR PLATE CONNECTION; 4" ACROSS THE TOP AND 2" DOWN SIDE THAT PROPAGATES INTO THE CAN.
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Documentation
Issued 15 November 1990 Resolved
PROVIDE ON BOARD ALL NEW CLASSIFICATION CERTIFICATES SHOWING NEW NAME.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Documentation
Issued 15 November 1990 Resolved
PROVIDE ON BOARD A CRANE RECORD BOOK IN ACCORDANCE WITH 46 CFR 109.437.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Lifesaving
Issued 15 November 1990 Resolved
LABLE ALL LIFE SAVING EQUIPMENT IN ACCORDANCE WITH 46 CFR 108 SUBPART G.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Accommodation/Occupational Safety
Issued 15 November 1990 Resolved
INSTALL CLOSURE FOR DRAIN ON CONTAINMENT FOR F/O VENTS PORTSIDE AFT OF QTRSAND INSTALL METTALIC VALVE OR PLUGS ON DRAIN FOR F/O DAY TANK VENT AT SAME LOCATION.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Electrical
Issued 15 November 1990 Resolved
MAKE REPAIRS TO JUNCTION BOX, LOOSE WIRING, AT PORT FWD CORNER OF CONTROL HOUSE (EXTERIOR). REMOVE OR PROPERLY ENCLOSE DEAD END CABLE ON STBD FWD CORNER OF CONTROL HOUSE (EXTERIOR).
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Accommodation/Occupational Safety
Issued 15 November 1990 Resolved
MAKE REPAIRS TO HOLES WASTED IN EXHAUST VENT PROT AFT SIDE OF QUARTERS ON TOP OF COVERS
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Accommodation/Occupational Safety
Issued 15 November 1990 Resolved
INSTALL SIGN READING "BEWARE OF TAILROTOR" AT ACCESS TO HELO DECK.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Electrical
Issued 15 November 1990 Resolved
REMOVE ALL DEAD END CABLES WHERE ANCHOR WINCHES REMOVED.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Lifesaving
Issued 15 November 1990 Resolved
REPAIR BROKEN LIFELINE ON #2 SURVIVAL CAPSULE.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Accommodation/Occupational Safety
Issued 15 November 1990 Resolved
REPAIR OR REPLACE TOP SECTION OF SUPPLY VENT FOR ROTARK TABLE NEAR #9 FIRE STATION.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Fire Fighting
Issued 15 November 1990 Resolved
PROVIDE ONBOARD ONE ADDITIONAL 50' X 1 1/2" FIRE HOSE AT STATION #12.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Electrical
Issued 15 November 1990 Resolved
MAKE PROPER REPAIRS TO THE AUXILIARY GENERATOR REMOTE SHUTDOWN.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Construction/Loadline
Issued 15 November 1990 Resolved
REPAIR OR REPLACE ALL PRELOAD TANK COVER GASKETS
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Fire Fighting
Issued 15 November 1990 Resolved
REPAIR OR REPLACE RISING STEM VALVE PACKING GLAND ABWE #1 FIRE PUMP.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Documentation
Issued 15 November 1990 Resolved
TEST AND PROVIDE DOCUMENTATION OF IOL TRANSFER HOSE IN ACCORDANCE WITH 33 CFR 155.800 AND 33 CFR 155.820.
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Documentation
Issued 15 November 1990 Resolved
PROVIDE ON BOARD A LOGBOOK IN ACCORDANCE WITH 46 CFR 109.431 WITH ENTRIES IN ACCORDANCE WITH 46 CFR 109.433
Condition: Unknown
Due 15 November 1990
Resolved 15 November 1990
Deck/Cargo
Issued 25 January 1990 Resolved
PROVIDE ONE BULK TANK RELIEF VALVE WITH HAND-RELIEVING DEVICE FOR BARITE TANK.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Electrical
Issued 25 January 1990 Resolved
PROVIDE APPROVED BATTERY CABLE CONNECTORS ON OBSTRUCTION LIGHT BATTERIES.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Engineering
Issued 25 January 1990 Resolved
REMOVE PUSH-ON FITTINGS AND INSTALL C.G. APPROVED FITTINGS ON EMERGENCY GENERATOR FUEL LINES
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Unknown
Issued 24 April 1989 Resolved
MAKE PERMANENT REPAIRS TO CRACKS IN STARBOARD SPUD CAN IN ACCORDANCE WITH COMMANDING OFFICER, MARINE SAFETY OFFICE, PORT ARTHUR, TEXAS LETTER 16711/ PENROD 66 DATED 22 MAY 1989.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Unknown
Issued 10 November 1988 Resolved
CONDUCT TEST OF OVERSPEED AND LOSS OF OIL PRESSURE ALARM FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Unknown
Issued 10 November 1988 Resolved
CONDUCT FIRE AND BOAT DRILL UPON ACTIVATION OF THE RIG.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Construction/Loadline
Issued 13 October 1988 Resolved
REPAIR OR RENEW 6 INCH CHEMICAL DUMP VALVE AND CHECK VALVE IMMEDIATELY INBOARD OF IT.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Construction/Loadline
Issued 13 October 1988 Resolved
SUBMIT REPAIR PROPOSAL FOR CRACKS FOUND IN STARBOARD SPUD CAN.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Construction/Loadline
Issued 13 October 1988 Resolved
PROVIDE COPY OF WELDERS QUALIFICATION AND APPROVED WELD PROCEDURES USED TO REPAIR "T" TO CORD CONNECTIONS AT ALL THREE LEGS.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Construction/Loadline
Issued 7 April 1988 Resolved
REPAIR AS NECESSARY ALL DUMP VALVE REACH ROD HANDLE ASSEMBLIES TO INDICATE WHETHER THE VALVE IS OPEN OR CLOSED.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Unknown
Issued 16 December 1987 Resolved
PROVIDE INFORMATION TO SHOW UL OR FM APPROVAL OF FORKLIFT, PER 108.611 AND NVC 4-78,CH. 1.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Unknown
Issued 16 December 1987 Resolved
PROVIDE GENERAL ALARM BELL FOR #1 "P" TANK ROOM. ADJUST THOSE BELLS NEEDING ADJUSTMENT TO MAKE SUFFICIENTLY CLEAR PER 46CFR 113.25-9.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Unknown
Issued 16 December 1987 Resolved
PROVIDE GENERAL ALARM BELL FOR #1 "P" TANK ROOM. ADJUST THOSE BELLS NEEDING ADJUSTMENT TO MAKE SUFFICIENTLY CLEAR, PER 46CFR 113.25-9.
Condition: Unknown
Due 16 December 1987
Resolved 16 December 1987
Unknown
Issued 27 March 1987 Resolved
PORT AND STBD LIFEBOATS TO BE OPERATED IN THE WATER (TO BE DONE AT LEAST ONCE A QUARTER).
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987
Lifesaving
Issued 21 November 1986 Resolved
COMPLETE THE FOLLOWING FOR PORT LIFEBOAT #2: (A) PROVIDE 84 QUARTS OF DRINKING WATER, (2) REPAIR WASTED STEERING CABLE CLIPS (IE. CLIPS THAT HOLDS THE TILLER CABLE IN PLACE), (C) REPAIR LEAKING EXHAUST SYSTEM ON ENGINE.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Construction/Loadline
Issued 21 November 1986 Resolved
PAINT, USING A CONTRASTING COLOR TO THE HULL, THE VESSELS NAME AND HOMEPORTON THE TRANSOM.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Electrical
Issued 21 November 1986 Resolved
REPAIR OR REPLACE SIX INOPERATIVE HELO DECK LIGHT BASES.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Accommodation/Occupational Safety
Issued 21 November 1986 Resolved
REPAIR BROKEN DOOR LOCK ON SICK BAY ROOM. THIS IS AN EMERGECY EXIT PASSAGEWAY.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Electrical
Issued 21 November 1986 Resolved
MAKE OPERABLE ALL EMERGENCY LIGHTS THROUGHOUT RIG; (APPROXIMATELY HALF ARE NOT WORKING).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Fire Fighting
Issued 21 November 1986 Resolved
REPAIR OR REPLACE BROKEN TWO AND A HALF INCH NAVY ALL PURPOSE COMBINATION. FIRE HOSE NOZZLE AT STATION #1.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Fire Fighting
Issued 21 November 1986 Resolved
REPLACE REJECTED 1 AN A HALF BY 50' FIRE HOSE AT HYDRANT STATION #21 (DRILL FLOOR).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Engineering
Issued 21 November 1986 Resolved
REPAIR WATER MAKERS IN MACHINARY SPACE (GASKETS LEAK)
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Accommodation/Occupational Safety
Issued 21 November 1986 Resolved
REPAIR OR REPLACE RELIEF VALVE ON POTABLE WATER TANK (HAND RELIEVING DEVICEINOPERABLE-VALVE APPEARS TO BE FROZEN-UP).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Deck/Cargo
Issued 21 November 1986 Resolved
REPAIR VENTILATION FAN FOR THE MVD PITS(BLADES BROKEN). ALSO RE-CONNECT MUD PIT LOSS OF VENTILATION ALARM.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Fire Fighting
Issued 21 November 1986 Resolved
PROVIDE CLOSING DEVICES FOR THE TOP AND SIDE VENTS ON THE PAINT LOCKER.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Deck/Cargo
Issued 21 November 1986 Resolved
HYDRO TEST THE FUEL OIL TRANSFER HOSE(S).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Electrical
Issued 21 November 1986 Resolved
PROPERLY TERMINATE ELECTRICAL CABLES WHERE WELDING MACHINES WERE REMOVED FROM THE ENGINE ROOM (OR RE-INSTALL WELDING MACHINES).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Construction/Loadline
Issued 21 November 1986 Resolved
REPAIR BROKEN AND MISSING BOLTS (STUDS) ON DECK MAN HOLE COVER LOCATED ON THE PORT SIDE BY THE LOADING STATION.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Lifesaving
Issued 21 November 1986 Resolved
PORT AND STBD LIFEBOATS TO BE OPERATED IN THE WATER (TO BE DONE AT LEAST ONCE A QUARTER).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Electrical
Issued 21 November 1986 Resolved
COMPLETE A TWO HOUR OPERATIONAL TEST OF THE EMERGENCY GENERTOR ( TO BE DONEAT LEAST ONCE A MONTH).
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Accommodation/Occupational Safety
Issued 21 November 1986 Resolved
PROVIDE RELIEF VALVES, SET AT NOT MORE THAN 40 PSI, FOR BULK TANKS #1 AND #2.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Electrical
Issued 21 November 1986 Resolved
GENEERAL ALARM BELLS: (A) BOW AREA-INOPERATIVE, (B) MAINDECK AREA-BELL MISSING, (C) SACK ROOM-BELL MISSING, (D) STBD GALLEY-NEEDS ADUSTMENT, (E) HALIBUTON ROOM-NEEDS ADJUSTING.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Lifesaving
Issued 21 November 1986 Resolved
COMPLETE THE FOLLOWING FOR STBD LIFEBOAT #1: (A) PROVIDE 84 QUARTS OF DRINKING WATER, (B) PROVIDE TWO SIGNAL ORANGE SMOKE CANISTERS.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Documentation
Issued 21 November 1986 Resolved
PROVIDE A LINE DAIGRAM OF THE FUEL OIL PIPING FOR THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Deck/Cargo
Issued 21 November 1986 Resolved
MAKE OPERABLE THE REMOTE SHUTDOWN FOR THE VENTILATION SYSTEM TO THE MACHINARY SPACES.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Construction/Loadline
Issued 18 April 1986 Resolved
PRIOR TO NEXT RIG MOVE, COMPLETE UNDERWATER SURVEY OF HOW LEG INCLUDING SPUD CAN INTERNALS. ALOS, COMPLETE REPAIRS TO THE FOUR GUIDE PLATE FRACTURES ON THE BOW LEG.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Unknown
Issued 28 December 1984 Resolved
INTERNALLY EXAMINE IN THE PRESENCE OF A USCG INSPECTOR THE TWO (2) AIR RECEIVERS IN THE COMPRESSOR ROOM 46 CFR 54.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
BENCH TEST IN THE PRESENCE OF A USCG INSPECTOR OF A USCG INSPECTOR THE RELIEF VALVE INSTALLED ON THE PIPING LEADING TO THE AIR RECEIVERS IN THE COMPRESSOR ROOM. 46 CFR 54.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Construction/Loadline
Issued 28 December 1984 Resolved
REATTACH THE REMOTE REACH ROD TO THE SEACHEST VALVE LOCATED IN THE BILGE PIT (46 CFR 56.50-50)
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Construction/Loadline
Issued 28 December 1984 Resolved
PROVIDE FIXED CONTAINMENT AT THE FUEL OIL TRANSFER STATIONS AND AT THE FUELTANK VENTS. CONTAINMENT SHALL BE CAPABLE OF HOLDING AT LEAST ONE BARREL AROUND EACH FUEL VENT OR FUEL FULL PIPE. 33 CFR 155.320.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Electrical
Issued 28 December 1984 Resolved
MAKE THE EMERGENCY LIGHTS IN THE MUD PIT ROOM OPERABLE AND LABEL EACH WITH AN "E" PLACARD. 46 CFR 112.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Electrical
Issued 28 December 1984 Resolved
LABEL ALL SWITCHES IN THE COMPRESSOR ROOM BREAKER PANEL 46 CFR 111.75.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE THE GATE VALUE ON THE LINE LEADING TO THE AFT AIR RECEIVER ABOVE THE COMPRESSORS. 46 CFR 107.231.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE THE RELIEF VALVE ON THE AFT AIR RECEIVER ABOVE THE COMPRESSOR. 46 CFR 54.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Deck/Cargo
Issued 28 December 1984 Resolved
REPLACE (5) RELIEF VALVES ON THE BULK CEMENT TANKS. 46 CFR 54.01.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Construction/Loadline
Issued 28 December 1984 Resolved
REPLACE THE DOGS ON THE HATCHES AT THE PORT JACKING HOUSE. ALSO, REPLACE THE MISSING DOGS ON THE DECK HATCHES IN THE VICINITY OF THE JACKING HOUSE 46 CFR 108.113.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, PENROD 66, DN570632, AND ARE TO BE COMPLIED WITH BY 29JAN85.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Lifesaving
Issued 28 December 1984 Resolved
REPLACE THE NEW 4-20 MAN THROWOVER LIFERAFTS WITH DAVIT LAUCHED APPROVED LIFERAFTS FOR 100 % COVERAGE OF CREW, (NVC 4-78 AND 46 CFR 108.505) PRIOR TO INSTALLATION, SUBMIT PLANS FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Lifesaving
Issued 28 December 1984 Resolved
WEIGHT TEST BOTH WHITAKER CAPSULES IN THE PRESENCE OF A USCG INSPECTOR (46 CFR 108.507)
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Fire Fighting
Issued 28 December 1984 Resolved
PROVIDE ONE (1) FIRESTATION FOR THE DRILL FLOOR WITH A 50' SECTION OF 1'2" HOSE 46 CFR 108.419.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Fire Fighting
Issued 28 December 1984 Resolved
REPLACE THE 2 1/2"X50' FIREHOSE NEAR THE HELICOPTER DECK. ALSO PROVIDE APPROVED COMBINATION NOZZLE FOR SAME STATION. 46 CFR 108.419.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Construction/Loadline
Issued 28 December 1984 Resolved
PROVIDE ABOARD THE RIG AN APPROVED CONSTRUCTION PORTFOLIO 46 CFR 107.305.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Electrical
Issued 28 December 1984 Resolved
PROVIDE EMERGENCY LIGHTS TO ILLUMINATE THE WATER AND THE EMBARKATION AREA FOR THE NEWLY INSTALLED RAFT STATIONS (46 CFR 111.75-15.)
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Lifesaving
Issued 28 December 1984 Resolved
PROVIDE THIRTEEN (13) CANS OF USCG APPROVED WATER FOR THE PORT LIFEBOAT 46 CFR 109.217(B).
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Lifesaving
Issued 28 December 1984 Resolved
PROVIDE FOURTEEN (14) CANS OF USCG APPROVED WATER FOR THE STARBOARD LIFE- BOAT. 46 CFR 109.217(B)
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Deck/Cargo
Issued 28 December 1984 Resolved
PROVIDE A PORTABLE FIVE (5) GALLON FUEL CONTAINER WITH SELF CLOSING SPOUT FOR REFUELING THE FORKLIFT (46 CFR 108.611)
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
PROVE PROPER OPERATION OF THE BILGE ALARMS.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPAIR BROKEN WELD TOP OF LADDER LEFT SIDE FOR ACCESS TO PRELOAD TANK #27.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE FALLS ON BOTH CAPSULES SERVICE MANUAL SPECIFICS 5 YEAR REPLACEMENT WITH AND AMENDMENTS TO 4 YEARS INTERVALS.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE THE BATTERIES FOR THE OBSTRUCTION LIGHTS.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE BROKEN GLASS ON EMERGENCY LIGHTS IN MUD PIT ROOM AND REPLACE BROKENBULB.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
SUBMIT FOR APPROVAL DOCUMENTATION INDICATING THE FM OR UL APPROVAL FOR THE FORKLIFT ON BOARD THE RAG.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPAIR LEAK IN FUEL TANK #13 PORTSIDE 20' INBOARD AND 10 FORWARD OF THE PORTSTERN LEG IN THE BOTTOM PLATING.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
PROVIDE DOCUMENTATION SUPPORTING THE INSTALLATION OF THE DIESEL POWERED WIRE LINE UNIT IN A HAZARDOUS LOCATION, DRILL FLOOR.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
COMPLETE UNDERWATER INSPECTION OF THE SPUD CANS AND CORD TO CAN CONNECTION PRIOR TO THE COMPLETION OF NEXT RIG MOVE BUT NO LATER THAN
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
SUBMIT FOR APPROVAL THE USE OF A JACOBS LADDER ON THE PORT SIDE THAT IS CURRENTLY INSTALLED.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
INSTALL ELECTRICAL PROTECTIVE MAT IN FRONT OF THE SWITCH BOARD ADJACENT TO THE NO. 1 GENERATOR.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPLACE RELIEF VALVES ON HOT WATER TANKS TO RELIEVE LESS THAN 100 PSIG.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
RELOCATE VENT FOR STANBY GENERATOR FUEL TANK TO VENT OUTSIDE THE SPACE.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
PROVIDE PLUG "CAM LOCK" FOR FUEL OIL FILL CONVECTION.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
REPAIR MISSING BROKEN DOGS ON VENT HATCH PORTSIDE FORWARD AND REPAIR GASKET PRELOAD 27.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
PROVIDE REQUIRED QUANITY OF TRIANGULAR BANDAGES(24).
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Unknown
Issued 28 December 1984 Resolved
PROVIDE TWO SPARE AIR BOTTLES FOR THE SCBA AND REFILL ONE BOTTLE THAT IS LOW IN PRESSURES.
Condition: Unknown
Due 28 December 1984
Resolved 28 December 1984
Fire Fighting
Issued 12 January 1984 Resolved
MAKE REPAIRS TO FIRE MAIN TO PROVIDE ADEQUATE PRESSURE TO STARBOARD SIDE OFLIVING SPACES ON EACH DECK.
Condition: Unknown
Due 12 January 1984
Resolved 12 January 1984
Unknown
Issued 30 January 1981 Resolved
PROVIDE ON BOARD A MINIMUM OF THREE A/B SEAMAN AND TWO ORDINARY SEAMAN.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Deck/Cargo
Issued 30 January 1981 Resolved
OBTAIN AND INSTALL THE NAME PLATE DATA TO THE KOOMEY UNIT ACCUMULATORS.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Unknown
Issued 30 January 1981 Resolved
PROVIDE MANUFACTURERS DATA SHEETS FOR ALL BULK MATERIAL TANKS.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Lifesaving
Issued 30 January 1981 Resolved
PROVIDE IN THE #1 SURVIVAL CAPSULE, 12 HAND HELD FLARES, ONE SMOKE CANISTER, AND ONE PISTOL FOR THE PARACHUTE FLARES.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Lifesaving
Issued 30 January 1981 Resolved
PROVIDE IN THE #2 SURVIVAL CAPSULE, 12 HAND HELD FLARES AND ONE SMOKE CANISTER.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Unknown
Issued 30 January 1981 Resolved
INSTALL TRACTION MOTOR CONNECTIONS FOR DRAW WORKS AND ROTARY TABLE IN AIR-PURGED OR EXPLOSIONPROOF BOXES.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Documentation
Issued 30 January 1981 Resolved
UPDATE THE CRANE RECORDS AS REQUIRED BY 46 CFR 109.437 AND 46 CFR 109.439.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Unknown
Issued 30 January 1981 Resolved
AIR-PURGE THE FOLLOWING EQUIPMENT:THE DRILLERS FOOT THROTTLE, SWACO UNIT, GAS DETECTION UNIT, AND DRILLERS CONSOLE.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Unknown
Issued 30 January 1981 Resolved
RELOCATE THE GENERAL ALARM CONTACT MAKER ON THE DRILL FLOOR TO MAKE IT READILY ACCESSABLE.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Unknown
Issued 30 January 1981 Resolved
RENEW ALL WASTED VALVES AND PIPING OVER THE MUD PITS.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981
Documentation
Issued 30 January 1981 Resolved
PROVIDE ON BOARD AN APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 30 January 1981
Resolved 30 January 1981

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.