Records from 1980 to 1990. Most recent: inspection, 23 September 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Unknown
Issued 22 March 1984
Resolved
PROVIDE SUITABLE CONTAINMENT FOR FUEL TAKE-ON MANIFOLD STATIONS AND FUEL VENTS.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Accommodation/Occupational Safety
Issued 22 March 1984
Resolved
REPLACE MISSING BACKS TO WASHER AND DRYER.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Electrical
Issued 22 March 1984
Resolved
REPAIR OR REPLACE DEFECTIVE BUNK LIGHTS AND OVERHEAD QUARTERS LIGHTS AS NEEDED.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Electrical
Issued 22 March 1984
Resolved
INSTALL EMERGENCY LIGHTS IN STAIRTOWERS AS NEEDED TO FACILITATE EGRESS IN EMERGENCY SITUATIONS.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Lifesaving
Issued 22 March 1984
Resolved
EQUIP RIG WITH EITHER DAVIT LAUNCHED LIFERAFTS OR ACCEPTABLE SUBSTITUTE (I.E. 200% CAPSULES), OR SHOW EVIDENCE OF EXEMPTION FROM 46 CFR 108.506.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Unknown
Issued 22 March 1984
Resolved
THE FOLLOWING REQUIREMENTS ARE ISSUED TO THE PENROD 61, DN536892.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Lifesaving
Issued 22 March 1984
Resolved
EQUIP BOTH LIFE CAPSULES WITH BOAT HOOKS IN ACCORDANCE WITH 46 CFR 108.503 AND 46 CFR 94.20-10.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Unknown
Issued 22 March 1984
Resolved
INSTALL REMOTE CONTROLS TO THE FUEL LINE VALVES FROM BOTH THE GENERATOR DAY TANK AND THE EMERGENCY GENERATOR FUEL TANK.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Electrical
Issued 22 March 1984
Resolved
INSTALL GENERAL ALARM BELLS OR LIGHTS IN THE FOLLOWING LOCATIONS: MUD PIT ROOM; SHALE SHAKER AND MAIN DECK FORWARD.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Unknown
Issued 22 March 1984
Resolved
REPAIR OR REMOVE SOUND POWERED PHONE SYSTEM.
Condition: Unknown
Due 22 March 1984
Resolved 22 March 1984
Unknown
Issued 29 March 1982
Resolved
TEST OVERSPEED AND REVERSE POWER RELAY.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REMOVE DEAD END POWER LEADS FOR THE OLD SANITARY WATER PUMPS OR PLACE IN A JUNCTION BOX.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE PROTECTION FROM THE EXHAUST PIPES ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
DRILL DRAINAGE HOLES IN THE BOTTOM OF THE CONTROL BOXES FOR THE BATTERY CHARGERS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE A VENT FOR THE EMERGENCY GENERATOR FUEL TANK WITH THE PROPER FLAME SCREEN.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR THE AUTOMATIC CLOSURE FOR THE PORT MUD PIT ROOM.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
MAKE ALL PENETRATIONS TO THE MUD PIT ROOM AIR TIGHT.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REWORK THE AUTOMATIC DOOR CLOSURE ON THE STBD MUD PIT DOOR.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPLACE THE MISSING COVER ON THE POTABLE WATER PRESSURE SWITCH.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE DOCUMENTATION TO SHOW PROOF THAT THE MSD IS COAST GUARD APPROVED.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REWORK AND MAKE OPERABLE THE FOLLOWING WATER TIGHT DOORS: PUMP ROOM, CHEMICAL ROOM, ENGINE ROOM.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE CAPACITY TABLE FOR THE FORKLIFT.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
COMPLETE WORK LIST ON ITEMS #1 - 12 DATED 3/29/82, PORT ARTHUR, TEXAS
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE AN APPROVED OPERATING MANUAL AS REQUIRED BY 46 CFR 109.121.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PLACE ON BOARD AN APPROVED FIRE CONTROL PLAN.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE AN APPROVED STABILITY LETTER.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PREPARE FOR INTERNAL EXAMINATION BOTH AIR RECEIVERS IN THE AIR COMPRESSOR ROOMS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
INSTALL APPROVED RELIEF VALVES ON ALL P-TANKS AND AIR RECEIVERS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR #1 AND #2 FIRE MAIN PUMPS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR DEFECTIVE EMERGENCY LIGHT ON THE AUXILIARY GALLEY.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
TEST AND RECORD DATA FOR FUEL OIL TRANSFER HOSES IN ACCORDANCE WITH 33 CFR 154.500.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
INSTALL A POLLUTION PLACARD AT THE FUEL OIL HEADER ON THE MAIN DECK.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROPERLY VENT PAINT LOCKER AND INSTALL LIGHT FIXTURE IN PAINT ROOM.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR DEFECTIVE STBD BOW ANCHOR CONTROLS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
STENCIL WORK VEST BINS ON DRILL FLOOR AND MAIN DECK AS FOLLOWS: WORK VESTSONLY".
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPLACE THE DEFECTIVE RING BUOY ON STBD SIDE AFT.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PLACE ON BOARD FMC CERTIFICATE.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR DAMAGED PORT CAPSULE.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
STENCIL AND NUMBER EACH SAFETY CAPSULES.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPLACE MISSING COVER SWITH FOR REFER COMPRESSOR.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR DEFECTIVE FOG HORN.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
REPAIR MISSING BELTS FOR WINCH ON PORT CAPSULE.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE RELIEF VALVES FOR #1 AND #2 FIRE PUMPS.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
PROVIDE A FLAME SCREEN ON THE LUBE OIL TANK IN THE ENGINE ROOM.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Unknown
Issued 29 March 1982
Resolved
MAKE OPERABLE THE LOW LUBE OIL ALARMS ON #1, 2, AND 3 AUXILIARY GENERATOR.
Condition: Unknown
Due 29 March 1982
Resolved 29 March 1982
Documentation
Issued 29 April 1980
Resolved
PROVIDE UNIT WITH AN APPROVED OPERATING MANUAL AS REQUIRED BY 46 CFR 109.121.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Deck/Cargo
Issued 29 April 1980
Resolved
MAKE REPAIRS TO WATERTIGHT DOOR TO MECHANIC'S STOREROOM.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Deck/Cargo
Issued 29 April 1980
Resolved
RENEW QUICK - CLOSING GATE VALVE FOR #8 DIESEL FUEL TANK.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Documentation
Issued 29 April 1980
Resolved
PROVIDE UNIT WITH AN APPROVED FIRE CONTROL PLAN. (46 CFR 107.305)
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Documentation
Issued 29 April 1980
Resolved
PROVIDE UNIT WITH APPROVED STABILITY LETTER AND STABILITY REQUIREMENTS.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Electrical
Issued 29 April 1980
Resolved
PROVIDE LEAD OR PMS ACID RESISTANT LINING FOR BATTERY CABINETS.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Unknown
Issued 29 April 1980
Resolved
HYDROSTATIC TEST OR PROVIDE SUPPORTING DATA FOR AIR RECEIVERS.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Fire Fighting
Issued 29 April 1980
Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS AS REQUIRED BY 46 CFR 107.235.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Lifesaving
Issued 29 April 1980
Resolved
PROVIDE ON BOARD THE DISTRESS SIGNALS AS REQUIRED BY 46 CFR 108.521.
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980
Navigation
Issued 29 April 1980
Resolved
PROVIDE HELICOPTER DECK WITH BLUE AND YELLOW LIGHTS AS REQUIRED BY 46 CFR 108.241(A)(2).
Condition: Unknown
Due 29 April 1980
Resolved 29 April 1980