Records from 1980 to 2003. Most recent: inspection, 10 May 2003.
Inspection history · 51
10 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1842342
25 February 1998
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780313
15 July 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 780238
15 July 1997
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1115755
16 October 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411364
18 October 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445023
10 February 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 839846
30 January 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1139254
14 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1147719
18 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 670691
14 October 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 181496
12 October 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1359974
13 November 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 681830
16 July 1991
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941240
5 July 1990
Certificate of Compliance · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1217562
29 March 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927001
29 March 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232448
9 February 1990
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930049
1 November 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 909692
29 October 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1282857
23 May 1989
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1206958
26 April 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196332
8 July 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 900598
10 November 1987
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1311317
1 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004485
4 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017982
20 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326786
9 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320887
20 January 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1319611
3 November 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332691
15 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1295124
2 July 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998979
12 September 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988917
15 July 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290632
3 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987679
16 January 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 977510
5 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980098
2 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976476
2 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283130
2 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284066
16 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968750
9 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969161
14 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966776
18 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272388
17 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273961
16 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275986
25 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964039
27 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272115
13 May 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275806
22 May 1980
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971575
22 May 1980
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276783
Fire Fighting
Issued 16 October 1996
Resolved
REPAIR VENT COVER ON PAINT LOCKER
Condition: Unknown
Due 31 October 1997
Resolved 25 October 1996
Construction/Loadline
Issued 16 October 1996
Resolved
REPAIR DOOR CLOSURER DEVICE ON THE BOTTOM DECK DOOR FORM THE DECK.
Condition: Unknown
Due 25 October 1996
Resolved 25 October 1996
Fire Fighting
Issued 16 October 1996
Resolved
PROVE PROPER OPERATION OF FIRE PUMP AND RELIEF VALUE.
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Fire Fighting
Issued 16 October 1996
Resolved
POST INSTRUCTION FOR SECONDARY HALON RELEASE.
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Fire Fighting
Issued 16 October 1996
Resolved
MOUNT LAUNDRY ROOM CO2
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Electrical
Issued 16 October 1996
Resolved
REPAIR PERIPHEAL LIGHTING BROKEN LOOSE FROM STAND AND PUT PROTECTIVE GAGE WHERE MISSING.
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Electrical
Issued 16 October 1996
Resolved
REPAIR EMERCY LIGHT ABOVE FIRE STATION #19 ON TOP DECK.
Condition: Unknown
Due 31 October 1996
Resolved 25 October 1996
Construction/Loadline
Issued 18 October 1995
Resolved
REPLACE LOWER HINGE PIN ON WATERTIGHT DOOR TO CHANGE ROOM.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Lifesaving
Issued 18 October 1995
Resolved
PROVIDE NON-SKID SURFACE FOR HELO DECK.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Lifesaving
Issued 18 October 1995
Resolved
REPAIR/REPLACE COMBUSTIBLE GAS/O2 METER TO FIREMAN'S OUTFIT IN CHANGE ROOM._x001C_ _x001C_
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Accommodation/Occupational Safety
Issued 18 October 1995
Resolved
REPAIR LEAKING PIPE ABOVE MARINE SANITATION DEVICE.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Fire Fighting
Issued 18 October 1995
Resolved
REPAIR GENERAL ALARM HORN IN ENGINE ROOM.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Lifesaving
Issued 18 October 1995
Resolved
PROVE PROPER OPERATION OF EYE WASH STATION ON DRILL FLOOR.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Engineering
Issued 18 October 1995
Resolved
PERFORM ANNUAL HYDROSTATIC TEST OF FUEL TRANSFER HOSE TO 1.5 TIMES MAWP.
Condition: Unknown
Due 25 October 1995
Resolved 25 October 1995
Electrical
Issued 18 October 1995
Resolved
MAKE PURGE LOSS ALARM FOR TOP DRIVE CONTACTOR BOX VISIBLE/AUDIBLE TO DRILLER.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Accommodation/Occupational Safety
Issued 18 October 1995
Resolved
REPAIR PIPE SUPPORT BRACKET FOR 12" PIPE ON BULKHEAD ACROSS FROM MARINE SANITATION DEVICE.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Electrical
Issued 18 October 1995
Resolved
PROPERLY SECURE CABLES AND ELECTRICAL OUTLET BOXES ON DERRICK.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Construction/Loadline
Issued 18 October 1995
Resolved
PATCH HOLES IN BULKHEAD OUTSIDE CHANGE ROOM DOOR.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Lifesaving
Issued 18 October 1995
Resolved
MAKE BOTH MUD PIT ROOM DOORS SELF CLOSE GAS TIGHT.
Condition: Unknown
Due 18 October 1995
Resolved 18 October 1995
Documentation
Issued 12 October 1994
Resolved
REVISE MODU OPERATING MANUAL TO COMPLY WITH 46CFR PART 109.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Lifesaving
Issued 12 October 1994
Resolved
UNTIL SATISFACTORY REPAIRS AS NEEDED TO BOTH MOTOR LIFEBOATS ARE COMPLETED THE TOTAL PERSONS ONBOARD ARE REDUCED TO 50. THIS ARRANGEMENT IS TEMPORARYAND MUST BE COMPLETED NOT LATER THAN 31DEC94.
Condition: Unknown
Due 12 October 1994
Resolved 12 October 1994
Electrical
Issued 16 July 1991
Resolved
PROPERLY HANG ALL WIRING JUST AFT OF DRILLER'S CONSOLE ON DRILL FLOOR.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
PROVIDE GUARD FOR PORT FWD AND AFT SPOT LIGHTS UNDER DRILL FLOOR.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Lifesaving
Issued 16 July 1991
Resolved
_x001C_ STRIP AND REPAINT BOTH LIFE BOATS.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
REPLACE HORN ALARM FORMUD SENTRY UNIT LOCATED IN PANEL AT DRILLER'S CONSOLEWITH EQUIP APPROVED FOR CLASS I DIV II AREA.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Engineering
Issued 16 July 1991
Resolved
REPAIR LEAKING SALT WATER PIPING ABOVE STBD MUD PUMP USED FOR MUD PUMP COOLING.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Lifesaving
Issued 16 July 1991
Resolved
REPLACE CHECK VALVE ON EMERGENCY AIR SUPPLY IN #1 LIFE BOAT.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
RENEW THE POWER CORDS RUNNING TO EACH OF FOUR SHALE SHAKER MOTORS IN LOWER SHAKER AREA.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Accommodation/Occupational Safety
Issued 16 July 1991
Resolved
RENEW MOUNTS FOR AIR RECEIVER UNDER DRILL FLOOR.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Documentation
Issued 16 July 1991
Resolved
RESUBMIT OPERATION MANUAL TO MEET 46 CFR 109.121.CORRECT TABLE OF CONTENTS & RIG NAME;GENERAL ARRANGEMENT PLANS FOR FIRE AND GAS DETECTORS;GUIDANCE ONRESTARTING ALL MECHANICAL, VENTILATING, & ELECTRICAL EQUIP. AFTER EVACUATION SHUTDOWNS;PROCEDURES FOR EVACUATING PERSONNEL FROM THE UNIT.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
PROPERLY HANG ALL WIRING LOCATED STBD AFT CORNER AREA RUNNING FWD ALONG STBD SIDE.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
PROPERLY HANG WIRE RUNNING ALONG "I" BEAM FWD STBD SIDE RUNNING TO PORT UNDER DRILL FLOOR.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 16 July 1991
Resolved
PROPERLY HANG WIRE RUNNING ALONG PORT SIDE OVERHEAD UNDER DRILL FLOOR.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING CPS REMOVE THE CGB TYPE CONNECTORS FROM SHALE SHAKER CONTROLLER ON THE FIRST LEVEL. INSTALL FITTING WITCH ARE ACCEPTABLE FOR CLASS I DIVI AREAS.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING REMOVE SILICONE FROM ALL EYS FITTINGS ON THE FIRST AND SECOND LEVELS OF THE SHALE SHAKER. RESEAL WITH CHICO DIELECTRIC
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Construction/Loadline
Issued 29 October 1989
Resolved
REPAIR THE CRACK IN THE WELD (HONEY COMB AREA) STBD SIDE SKIDDER MOTOR BRACE ASSEMBLE
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Construction/Loadline
Issued 29 October 1989
Resolved
MAKE REPAIRS TO THE SHUE PLATE ON THE JACKING TOWER, BOW LEG INBOARD & OUTBOARD SIDE ON THE PORT SIDE.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING OPS POUR ALL OTHER EYS FITTINGS IN THE SHALE SHAKER AREA.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING OPS REMOVE SPLICE IN WIRE AT FLOW PADDEL SENSOR IN THE MUD DITCH
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING INSTALLED SEALED FITTINGS ACCEPTABLE CLASS I DIV I ON THE DC GENERATOR ROTARY RPMS AND THE TWO OTHER CONTROLLERS ON THE MOTOR.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING POUR ALL EYS FITTINGS WITH CHICO MAT ARE EATHER EMPTY OR FULLOF SILICONE ON ALL SWITCH BOXES IN THE CLASS I DIV II AREAS. ENSURE AT LEAST 5 THREAD ARE MADE INTO THE SWITCH BOX WITH THE EYS.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
REPLACE POWER CORD TO MONITOR THAT NORMALY SITES ON DRILLERS CONSOLE.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
REMOVE ALL SILICONE FRON ALL EYS FITTINGS IN CLASS I DIV II AREAS REPOUR WITH CHICO ON USED FITTING APPROVED FRON CLASS I DIV II AREAS (UL,FM,CSA- APPROVED.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Construction/Loadline
Issued 29 October 1989
Resolved
PROVIDE A DRAWING WHICH SHOWES THE FIRE MONITOR INSTALLATION ALONG THE STERN OF THE BARGE WHICH WAS REQUIRED BY EXXON, PROVIDE CHANG TO FIRE SAFETY PLAN.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Construction/Loadline
Issued 29 October 1989
Resolved
MAKE REPAIR TO THE CRACK IN THE WELD ON THE SHUE PLATE OF THE JACKING TOWERON THE PORT LEG , INBOARD CORD.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING OPS POUR THE EYS FITTING FROM THE J BOX 408V POWER SUPPLYTO THE LOGGING TRAILER.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
REMOVE THE S.O. TYPE CABE RUN FROM THE MARINE TYPE MRECEPTICLE LOCATED ON THE WIRE THE WAY NEXT TO THE DEEP WELL REWIRE WITH ACCEPTABLE TYPE CABLE IN ACCORDANCE 46CFR SUB J.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
PRIOR TO DRILLING OPS POUR THE EYS FITTINGS OVER THE MUD DITCH ADJACENT TO TO THE TRIP TANK.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Electrical
Issued 29 October 1989
Resolved
REHANG OR REMOVE AND TERMINATE THE J BOX UNDER THE DRILL FLOOR ON THE CATWALK.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Lifesaving
Issued 29 October 1989
Resolved
REMOVE THE PORT LIFERAFT HYDRO STATIC RELEASE.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Unknown
Issued 29 October 1989
Resolved
REMOVE THE DUBBLERS FROM THE BULK SYSTEM PIPING, NEW PIPING TO BE INSERTED.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Unknown
Issued 29 October 1989
Resolved
INSTALL A REMOTE REACH ROD OR GATE VALVE THAT WILL SECURE THE FUEL TO THE EMERGENCY GENERATOR FROM OUTSIDE THE SPACE.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Unknown
Issued 29 October 1989
Resolved
REPLACE THE FLEX EXPANION JOINT IN THE #1 BILGE PUMP PIPING SYSTEM.
Condition: Unknown
Due 29 October 1989
Resolved 29 October 1989
Construction/Loadline
Issued 23 May 1989
Resolved
PRESENT FOR COAST GUARD INSPECTION THE PORT, STARBOARD & BOW LEG TO SPUD CAN CONNECTIONS & SPUD CANS.
Condition: Unknown
Due 23 May 1989
Resolved 23 May 1989
Lifesaving
Issued 8 July 1988
Resolved
CONDUCT TEST OF THE DISENGAGING APPARATUS AND OPERATIONALLY TEST BOTH LIFEBOATS IN THE WATER.
Condition: Unknown
Due 8 July 1988
Resolved 8 July 1988
Navigation
Issued 10 November 1987
Resolved
REPLACE BURNT OUT NAVIGATION LIGHT BULBS TO PORT AND STERN RUNNING LIGHTS.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Electrical
Issued 10 November 1987
Resolved
REPAIR PURGE ALARMS ON DRILL FLOOR.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Fire Fighting
Issued 10 November 1987
Resolved
REPAIR SELF-CLOSING DOOR TO MUD PIT ROOM.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Fire Fighting
Issued 10 November 1987
Resolved
REPAIR REMOTE VENT STOPS TO MACHINERY SPACES AT LOCATIONS MARKED ON FIRE AND SAFETY PLAN.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Electrical
Issued 10 November 1987
Resolved
REPLACE ELECTRIC JUNCTION BOX BOLTS TO JUNCTION BOX ON DRILL FLOOR.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Lifesaving
Issued 10 November 1987
Resolved
PROVIDE 12 HAND HELD FLARES FOR EACH LIFEBOAT.
Condition: Unknown
Due 10 November 1987
Resolved 10 November 1987
Accommodation/Occupational Safety
Issued 2 July 1986
Resolved
PROVIDE "DEAD MAN" TYPE NOZZEL ON THE FUEL OIL FILL HOSE FOR THE LOGGING UNIT.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Deck/Cargo
Issued 2 July 1986
Resolved
PROVIDE DOCUMENTATION THAT FUEL OIL TRANSFER HOSE IS SUITABLE FOR OIL SERVICE OR REPLACE.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Fire Fighting
Issued 2 July 1986
Resolved
PROVIDE THE FIREMAN'S OUTFIT LOCATED ON THE MAIN DECK WITH TWO (02) AIR BOTTLES WITH THE REQUIRED PRESSURE. ONE BOTTLE INDICATES +- 1800 PSI. PROVIDE NON CONDUCTIVE GLOVES FOR BOTH FIREMAN'S OUTFITS.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Fire Fighting
Issued 2 July 1986
Resolved
POST A STAMPED APPROVED COPY OF THE FIRE CONTROL PLAN.
Condition: Unknown
Due 2 July 1986
Resolved 2 July 1986
Deck/Cargo
Issued 3 June 1985
Resolved
HYDROSTATICALLY TEST THE OIL TRANSFER HOSE AND INITIATE RECORD KEEPING (REF 33 CFR 155.800 AND 155.820.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Electrical
Issued 3 June 1985
Resolved
PROVIDE EVIDENCE OF COAST GUARD APPROVAL OF THE HAZARDOUS LOCATION PLAN REF NVC 4-78.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Electrical
Issued 3 June 1985
Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELLS IN THE FOLLOWING LOCATIONS, MUD PIT ROOM, SHALE SHAKER ROOM, AND MAIN DECK IN WAY OF CEMENT PUMP (REF 46 CFR 113,25.
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Lifesaving
Issued 3 June 1985
Resolved
REMOVE KNOTED MAN ROPES LOCATED AT PORT AND STBD LIFEBOAT STATIONS (REF 46CFR 108.527).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Unknown
Issued 3 June 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL KEYES 250 DN621977
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Fire Fighting
Issued 3 June 1985
Resolved
RESUBMIT FIRE CONTROL PLAN FOR APPROVAL REFLECTING THE FIXED FOAM SYSTEM WHICH IS INSTALLED ON THE HELO DECK IN ACCORDANCE WITH 46CFR 107-305 (Y).
Condition: Unknown
Due 3 June 1985
Resolved 3 June 1985
Construction/Loadline
Issued 16 July 1982
Resolved
CONDUCT UNDERWATER PORTION OF SPECIAL SURVEY IN LIEU OF DRYDOCKING. AT TIMEOF NEXT RIG MOVE.
Condition: Unknown
Due 12 September 1982
Resolved 16 July 1982
Documentation
Issued 25 June 1982
Resolved
PROVIDE AT LEAST FOUR (4) CERTIFICATED LIFEBOATMEN FOR EACH HITCH I.A.W. THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982
Documentation
Issued 25 June 1982
Resolved
SUBMIT FOR APPROVAL AND PROVIDE AN APPROVED COPY OF THE LIFESAVING AND FIRECONTROL PLAN, AND THE HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982
Documentation
Issued 25 June 1982
Resolved
BEGIN END MAINTAIN A VESSEL LOG WITH THE INFORMATION CONTAINED IN 46 CFR 109.431-.433
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982
Accommodation/Occupational Safety
Issued 25 June 1982
Resolved
MAKE THE FOLLOWING AIR RECEIVERS AVAILABLE FOR INTERNAL EXAM OR HYDROSTATICTEST: 21724 HOU 79-1066; HOU 79-1159; NO. 21725, HOU 79-1160.
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982
Documentation
Issued 25 June 1982
Resolved
SUBMIT PROPOSAL FOR DRYDOCKING, A SPECIAL EXAMINATION IN LIEU OF DRYDOCKINGI.A.W. 46 CFR 107.267 TO [name withheld].
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982
Documentation
Issued 25 June 1982
Resolved
HAVE ANNUAL ABS SURVEY CONDUCTED.
Condition: Unknown
Due 25 June 1982
Resolved 25 June 1982