MAURY USCG vessel records Sign in
← All vessels

INTEROCEAN II

INTEROCEAN II is a 1977 mobile offshore drilling unit. The Coast Guard has recorded 11 inspections since 1981, most recently in June 1990, along with 21 deficiencies.

Records from 1981 to 1990. Most recent: inspection, 21 June 1990.

Built
1977
Last inspected
21 June 1990
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-52365

Inspections, by type

…with no type recorded5
Years with a record 7 calendar years (1981–1990)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 36 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3457 - Regulatory (Subpart C or D), Net Ton
4821 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

21 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899589
16 September 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1349805
31 August 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041667
12 June 1988 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1339533
14 January 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006168
30 June 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 996825
2 July 1984 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 974933
17 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964284
17 June 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281012
31 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273967
1 June 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274617

Deficiency record · 21

Construction/Loadline
Issued 12 June 1988 Resolved
PROVIDE VIDEO TAPE, DIVERS REPORT AND NDT REPORT OF U/W IN LIEU OF DRYDOCKING EXAM.
Condition: Unknown
Due 12 June 1988
Resolved 12 June 1988
Engineering
Issued 12 June 1988 Resolved
PROVIDE APPROVED SAFETY RELIEF VALVES FOR BULK TANKS AND SHIP SERVICE AIR RECEIVERS.
Condition: Unknown
Due 12 June 1988
Resolved 12 June 1988
Lifesaving
Issued 30 June 1986 Resolved
PROVIDE ANNUAL TEST OF 6 HYDROSTATIC RELEASES FOR 6 INFLATABLE LIFERAFTS.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVIDE TWO 50 FT. LENGTHS OF U.S. COAST GUARD APPROVED 1 1/2" FIRE HOSE FOR A TOTAL OF 23.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986 Resolved
PROVIDE 1500 FT. OF AUXILIARY LINE FOR LINE THROWING GUN IN ACCORDANCE WITH46 CFR 94.45-15(A)(6).
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVE THAT THE FOUR SELF CONTAINED BREATHING APPARATUS USED IN THE FIREMENSOUTFITS ARE OF THE APPROVE TYPE IN ACCORDANCE WITH 46 CFR 160.011.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Unknown
Issued 30 June 1986 Resolved
PROVIDE A WIND INDICATOR FOR HELICOPTER FLIGHT DECK IN ACCORDANCE WITH 46 CFR 108.241(A)(1).
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVIDE 3 CELL EXPLOSION PROOF (U.S. COAST GUARD APPROVED) FLASHLIGHTS FOR FOUR FIREMENS OUTFITS (4 TOTAL).
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVIDE U.S. COAST GUARD APPROVED FIRE AXES FOR FOUR FIREMEN'S OUTFITS (4 TOTAL).
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Engineering
Issued 30 June 1986 Resolved
PROVE THE PROPER OPERATION OF (OR REPLACE) #2 AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVE THE PROPER OPERATION OF THE SCR ROOM FIXED HALON SYSTEM, WHICH HAS BEEN ELECTRICALLY DISCONNECTED.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
PROVE THE PROPER OPERATION OF THE ENGINE ROOM FIRE ALARM/DETECTION SYSTEM.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986 Resolved
REPLACE MISSING H2S GAS DETECTION MODULE IN GAS DETECTION CONTROL CONSOLE, AND PROVE PROPER OPERATION OF THE H2S GAS DETECTION SYSTEM.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Engineering
Issued 30 June 1986 Resolved
PROVE THE PROPER OPERATION OF (OR REPLACE) THE SAFETY RELIEF VALVE NO. 1 AUXILIARY BOILER.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Electrical
Issued 30 June 1986 Resolved
PROVIDE A LEAD OR OTHER CORROSION, RESISTANT WATERTIGHT LINER FOR NO. 1 ANDNO. 2 BATTERY BOXES IN ACCORDANCE WITH 46 CFR 111.15-5(G)(2).
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 2 July 1984 Resolved
RENEW ALL FIRE HOSES THAT DO NOT MEET U. S. COAST GUARD REQUIREMENTS, WITH HOSE MEETING U.L. STANDARD 19.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Unknown
Issued 2 July 1984 Resolved
PROVIDE PROPER DOCUMENTATION TO PROVE U. S. COAST GUARD APPROVAL OF HELO DECK LANDING LIGHTS.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Lifesaving
Issued 2 July 1984 Resolved
ENSURE ALL EQUIPMENT AND PROVISIONS IN STARBOARD LIFEBOAT ARE U.S. COAST GUARD APPROVED.
Condition: Unknown
Due 2 July 1984
Resolved 2 July 1984
Lifesaving
Issued 17 June 1982 Resolved
PROVIDE TWO (2) BOUYANT ROCKETS AND ONE (1) SERVICE LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 17 June 1982
Resolved 17 June 1982
Fire Fighting
Issued 17 June 1982 Resolved
PROVIDE BATTERY BOX FOR EMERGENCY FIRE PUMP.
Condition: Unknown
Due 17 June 1982
Resolved 17 June 1982
Fire Fighting
Issued 17 June 1982 Resolved
PROVIDE U.S. COAST GUARD APPROVED OR U.L. MARINE TYPE PORTABLE AND SEMI- PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH 46 CFR 108.495(A).
Condition: Unknown
Due 17 June 1982
Resolved 17 June 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.