MAURY USCG vessel records Sign in
← All vessels

NIKI V

NIKI V is a 1980 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1980, most recently in February 1997, along with 96 deficiencies.

Records from 1980 to 1997. Most recent: inspection, 19 February 1997.

Built
1980
Last inspected
19 February 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTL2861
Flag
UNITED STATES
—
Maury page id
psix-52449

Inspections, by type

…with no type recorded19
Years with a record 16 calendar years (1980–1997)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Net Ton
32 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

19 February 1997 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1105492
5 December 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1187621
2 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 877803
7 August 1996 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1095309
31 July 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1466979
24 May 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1086192
14 June 1995 Deficiency Check · Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1187500
30 May 1995 Deficiency Check · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1377423
26 April 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 865708
8 April 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664430
8 February 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 196649
8 February 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 375234
8 February 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 755124
21 December 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1155160
1 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 868971
28 November 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664423
22 November 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 664427
21 November 1994 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 70457
21 November 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 849296
6 October 1994 Hull Examination · Damage Survey
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1431407
17 May 1994 Re-Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410973
22 July 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 847239
10 June 1993 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410825
14 January 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1134976
1 September 1992 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 959128
30 June 1992 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1257973
8 June 1992 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 955105
21 October 1991 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 942839
26 August 1991 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 942849
24 July 1990 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 915061
30 June 1990 Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 924610
16 February 1990 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 919373
15 May 1989 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1353010
11 April 1989 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1195345
18 January 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1199224
10 November 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203953
27 September 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1200146
9 May 1988 COI Inspection · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1042268
9 May 1988 Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1350366
17 April 1987 COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1000204
21 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287542
19 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280662
27 September 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973763
31 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276091
22 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968634

Deficiency record · 96

Construction/Loadline
Issued 31 July 1996 Resolved
Repair hole through sideshell portside aft in steering compartment.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Navigation
Issued 31 July 1996 Resolved
Double-nut or use cotterpins on all Hydraulic ram cylinders and arms in steering compartment.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Fire Fighting
Issued 31 July 1996 Resolved
Replace B-II portable fire extinusher--passenger deck starboard side. Use marine type mount for securing.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Documentation
Issued 31 July 1996 Resolved
PROVIDE PROOF OF PARTICIPATION IN DRUG TESTING PROGRAM.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Construction/Loadline
Issued 31 July 1996 Resolved
Place remotely operated valve at collision bulkhead or remove bilge suctionand cap pipe IAW 182.25-5(d)
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Construction/Loadline
Issued 31 July 1996 Resolved
Renew gasket to engineroom hatch cover.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Lifesaving
Issued 31 July 1996 Resolved
Renew or replace waterlight attached to forward B/A
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Electrical
Issued 31 July 1996 Resolved
Remove or renew breaker box below seat in wheelhouse.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Documentation
Issued 31 July 1996 Resolved
PROPERLY LOG FIRE AND BOAT DRILLS, CREW TRAINING, ETC. IAW NEW INTERM FINALRULES.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Electrical
Issued 31 July 1996 Resolved
PROPERLY CONNECT WIRING WITH COMPRESSION TYPE FITTING AND REMOVE OR PLACE IN J-BOX DEAD END WIRING.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Engineering
Issued 31 July 1996 Resolved
PROPERLY INSTALL FLAME SCREENS TO FUEL VENTS. REMOVE WRITING ON MACHINERY SPACE VENT THAT STATES IT IS A FUEL OIL VENT.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Documentation
Issued 31 July 1996 Resolved
PROVIDE COPY OF MASTERS LICENSE.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Construction/Loadline
Issued 31 July 1996 Resolved
PROVIDE HAND BILGE PUMP.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Navigation
Issued 31 July 1996 Resolved
No later than 11 Mar 97 install onboard in a float free arrangement a FCC accepted CAT 1 406 EPRIB. In lieu of the above the vessel's route may be changed to not more than 3 miles from shore within U.S. territorial waters_x001C__x001C_
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Electrical
Issued 31 July 1996 Resolved
Mount/install a flashlight at operating station and at entrance to machinery space (engineroom)
Condition: Unknown
Due 10 August 1996
Resolved 10 August 1996
Lifesaving
Issued 31 July 1996 Resolved
Properly secure manlines on buoyant appratus.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Lifesaving
Issued 31 July 1996 Resolved
Remove half-filled open oil drum from passenger cabin.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Lifesaving
Issued 31 July 1996 Resolved
Stencil aft buoyant appratus with vessels name.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Lifesaving
Issued 31 July 1996 Resolved
Properly mark pyro container w/distress signals and paint storage containera bright color (orange) IAW 185.614.
Condition: Unknown
Due 30 August 1996
Resolved 10 August 1996
Lifesaving
Issued 30 May 1995 Resolved
INSTALL A ONE-HUNDRED FOOT TETHER ON ONE BUOYANT APPARATUS.
Condition: Unknown
Due 30 May 1995
Resolved 30 May 1995
Electrical
Issued 26 April 1995 Resolved
REMOVE ALL LOOSE UNUSED WIRING FROM UNDER PILOT CONSOLE.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
RE-STENCIL VESSEL'S NAME ON ALL LIFE JACKETS AS NECESSARY.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 26 April 1995 Resolved
STENCIL VESSEL'S NAME ON RING BUOYS.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Documentation
Issued 26 April 1995 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Construction/Loadline
Issued 26 April 1995 Resolved
REMOVE EXCESS OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Construction/Loadline
Issued 8 February 1995 Resolved
Observed excessive oil and fuel in bilge.
Condition: Unknown
Due 8 February 1995
Resolved 13 February 1995
Construction/Loadline
Issued 8 February 1995 Resolved
Repair oil and fuel leaks in engine room to prevent draining of oil and fuel into bilge.
Condition: Unknown
Due 8 February 1995
Resolved 13 February 1995
Lifesaving
Issued 8 February 1995 Resolved
Replace 1 wasted PFD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 February 1995
Resolved 13 February 1995
Fire Fighting
Issued 8 February 1995 Resolved
Service 1 discharged fire extinguisher.
Condition: Unknown
Due 8 February 1995
Resolved 13 February 1995
Engineering
Issued 21 November 1994 Resolved
Repair all lube oil leaks to eliminate oil from spraying in engineroom.
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Construction/Loadline
Issued 21 November 1994 Resolved
Remove and properly dispose of all oil from engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 November 1994
Resolved 21 November 1994
Construction/Loadline
Issued 6 October 1994 Resolved
REPAIR HULL DAMAGE ON BOTTOM PLATING BENEATH STARBOARD BATTERY BOX._x001C_
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 6 October 1994 Resolved
REPAIR RUB RAIL, STARBOARD SIDE BOW._x001C_
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Construction/Loadline
Issued 6 October 1994 Resolved
REMOVE IMPROPER REPAIR (DOUBLER PLATE) FROM PORT BOW AND REPAIR WITH PROPERINSERT._x001C_
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Engineering
Issued 6 October 1994 Resolved
REPLACE BOTH MAIN PROPULSION TAILSHAFTS.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 6 October 1994 Resolved
PLUG OR SEAL UNUSED KEEL COOLING LINES IN ENGINEROOM._x001C_
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Electrical
Issued 6 October 1994 Resolved
REMOVE ALL ACCESSORIES ASSOCIATED WITH OLD GENERATOR.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 6 October 1994 Resolved
PROPERLY WELD STARBOARD THROUGH-HULL FITTING, AFT, FOR LAZARETTE BILGE DISCHARGE.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Lifesaving
Issued 6 October 1994 Resolved
REMOVE ACCUMULATED OIL FROM BILGES._x001C_
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Navigation
Issued 6 October 1994 Resolved
REPAIR LOOSE STARBOARD RUDDER. REPLACE WASTED OR MISSING ITEMS TO MAKE RUDDER AND ASSOCIATED GEAR COMPLETE AND PROPER._x001C_
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Engineering
Issued 6 October 1994 Resolved
REPLACE WORN CUTLASS BEARINGS AS REQUIRED.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Lifesaving
Issued 17 May 1994 Resolved
REATTACH PENDANTS ON ALL BOUYANT APPARATUS.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Documentation
Issued 17 May 1994 Resolved
PROVIDE DESCRIPTION OF COMPANY'S DRUG TESTING PROGRAM.
Condition: Unknown
Due 17 May 1994
Resolved 17 May 1994
Electrical
Issued 10 June 1993 Resolved
PROVIDE COVER FOR OVERHEAD LIGHT IN PILOT HOUSE.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 10 June 1993 Resolved
REPAIR EMERGENCY FUEL SHUTOFF REACH ROD.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Construction/Loadline
Issued 10 June 1993 Resolved
PROVIDE DOUBLE CLAMP AT THROUGH HULL FITTING FOR BILGE DISCHARGE IN AFTER STEERING.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 10 June 1993 Resolved
RECONNECT FUEL FILL GROUND STRAP.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 10 June 1993 Resolved
REPAIR AND DEMONSTRATE OPERATION OF GENERATOR.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Electrical
Issued 10 June 1993 Resolved
PROVIDE DOUBLE CLAMP AT GENERATOR RAW WATER COOLING HOSE.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 1 September 1992 Resolved
SEAL FUEL FILL FITTING ON MAIN DECK TO MAKE WATER TIGHT.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Accommodation/Occupational Safety
Issued 1 September 1992 Resolved
REPAIR CRACKED WELDS ON RAILINGS, PORT SIDE FORWARD.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Engineering
Issued 1 September 1992 Resolved
PROVIDE GROUNDING STRAPS FOR FUEL FILL PIPPING.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Construction/Loadline
Issued 1 September 1992 Resolved
PLUG NINE (09) SMALL HOLES (8 PORT SIDE/1 STBD SIDE) IN FORWARD BLKHD OF STEERING ROOM._x001C_
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Engineering
Issued 1 September 1992 Resolved
PROVIDE DOUBLE CLAMPS ON FUEL VENT HOSE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Construction/Loadline
Issued 1 September 1992 Resolved
PROVIDE SKIN VALVE FOR STEERING ROOM BILGE PUMP, OVERBOARD DISCHARGE.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Navigation
Issued 1 September 1992 Resolved
REPACK BOTH RUDDERS.
Condition: Unknown
Due 1 September 1992
Resolved 1 September 1992
Electrical
Issued 8 June 1992 Resolved
Secure electircal connection forward of the port engine.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Engineering
Issued 8 June 1992 Resolved
Replace flexible fuel supply return lines on both engines.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Lifesaving
Issued 8 June 1992 Resolved
Properly label all life jacket stowage areas with the number of adult_x001C_ and child life jackets. Remove placards where applicable.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Fire Fighting
Issued 8 June 1992 Resolved
Provide an additional B-II fire extinguisher. Vessel should have a total_x001C_ of four B-II extinguishers. (pg 2 of the vessel COI pertaining to_x001C_ number of fire extinguishers is incorrect-the Coast Guard will correct thisadminstrative descrpancy prior to re-issue of C.O.I.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Lifesaving
Issued 8 June 1992 Resolved
Stencil the vessel's name on all paddles associated with bouyant_x001C_ apparatuses.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Lifesaving
Issued 8 June 1992 Resolved
Replace the grablines on the life ring (port side).
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Remove all wiring located behing the pilot house console which is not_x001C_ presently in use.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Navigation
Issued 8 June 1992 Resolved
Replace the missing key on the starboard rudder post.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Engineering
Issued 8 June 1992 Resolved
Replace clamp of fuel fill line.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Properly mount circuit breaker on the aft bulkhead in the machinery _x001C_ space.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Construction/Loadline
Issued 8 June 1992 Resolved
Replace missing dog on watertight hatch allowing access to steering _x001C_ compartment.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Provide covers for the main A/C switch board.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Provide a lead or fiberglass lined box with cover for the battery _x001C_ used to service the pilot house.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Fire Fighting
Issued 8 June 1992 Resolved
Provide the proper bracket for the B-1 fire extinguisher in the_x001C_ pilot house.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Provide generator efficiency rating plate for operation with a space_x001C_ having an ambient temperature of fifty (50) degrees centigrade.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Electrical
Issued 8 June 1992 Resolved
Repair the light above the generator.
Condition: Unknown
Due 8 June 1992
Resolved 8 June 1992
Lifesaving
Issued 21 October 1991 Resolved
BUOYANT APP WAS NOT EQUIPPED WITH A 100' PAINTER.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Electrical
Issued 21 October 1991 Resolved
BATTERY CHARGER WIRING WAS NOT PERMANENTLY INSTALLED (HARD WIRED) IN_x001C_ MACHINERY SPACE.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Engineering
Issued 21 October 1991 Resolved
VESSEL HAD OIL LEAKS ON BOTH MAIN DIESEL ENGINES AND AN UNACCEPTABLE AMOUNTOF OIL IN THE BILGE. _x001C_
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Electrical
Issued 21 October 1991 Resolved
VESSEL HAD INADEQUATE WIRING FOR VHF RADIO UNDER THE BRIDGE_x001C_ CONSOLE. THE WIRING WAS EXTREMELY HOT UPON INSPECTION.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Electrical
Issued 21 October 1991 Resolved
VESSEL HAD EXCESSIVE "DEAD END" WIRING WITH NO INTENDED USE UNDER_x001C_ BRIDGE CONSOLE.
Condition: Unknown
Due 21 January 1992
Resolved 21 January 1992
Electrical
Issued 21 October 1991 Resolved
VESSEL WAS NOT EQUIPPED W/ FLASHLIGHTS OR OTHER ADEQUATE MEANS OF _x001C_ EMERGENCY LIGHTING.
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Construction/Loadline
Issued 21 October 1991 Resolved
VESSEL HAD THREE 1/8" HOLES IN MAINDECK OVER FOREPEAK. HOLES WERE_x001C_ ORGINALLY DRILLED TO INSTALL A LIFERAFT MOUNT; HOWEVER, THE LIFEBOAT_x001C_ MOUNT HAD BEEN REMOVED SEVERAL MONTHS PRIOR TO INPSECTION._x001C_ _x001C_
Condition: Unknown
Due 16 January 1992
Resolved 16 January 1992
Electrical
Issued 21 October 1991 Resolved
ALL GUAGES/INDICATORS ON THE VESSEL'S SHIP SERVICE GENERATOR WERE_x001C_ INOPERABLE.
Condition: Unknown
Due 26 February 1993
Resolved 3 February 1992
Electrical
Issued 30 June 1990 Resolved
REMOVE AUTO TYPE BATTERY CHARGER AND INSTALL MARINE TYPE UL APPROVED CHARGER.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Construction/Loadline
Issued 30 June 1990 Resolved
PROVIDE A HAND FIRE/BILGE PUMP WHICH HAS A SUFFICIENT LENGTH DISCHARGE HOSE.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Engineering
Issued 30 June 1990 Resolved
REPAIR HOLED FLAME SCREEN FOR FUEL TANK VENT LOCATED ON PORT SIDE.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Construction/Loadline
Issued 30 June 1990 Resolved
MARK HOME PORT ON STERN OF VESSEL.
Condition: Unknown
Due 30 June 1990
Resolved 30 June 1990
Fire Fighting
Issued 11 April 1989 Resolved
RELOCATE PORTABLE FIRE EXTINGUISHER IN ENGINE ROOM IAW GOOD MARINE PRACTICE.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
MARK LIFE FLOATS AS REQUIRED BY 46CFR 180.20-5
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Navigation
Issued 11 April 1989 Resolved
LOCATE STERN LIGHT AS REQUIRED IN NAVIGATION RULES, COMDTINST M16672.2A RULE NUMBER 21.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 27 September 1988 Resolved
STOW PFD'S IN ACCORDAMCE WITH 46 CFR 180.25-10(A).
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Engineering
Issued 9 May 1988 Resolved
REMOVE ALL OIL FROM THE ENGINE ROOM BILGE AND THE MAIN COMPARTMENT BILGE.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Construction/Loadline
Issued 9 May 1988 Resolved
GOUGE AND WELD THE CRACK IN THE ENGINE ROOM BULKHEAD WHERE THE PORT AND STARBOARD EXHAUST PIPES PASS THROUGH.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Construction/Loadline
Issued 9 May 1988 Resolved
REWELD THE WASTED AREA BELOW THE PORT BATTERY BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Electrical
Issued 9 May 1988 Resolved
SEAL ALL HOLES IN THE PORT ENGINE ROOM BATTERY BOX.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 9 May 1988 Resolved
RENEW ALL EXHAUST HOSES IN THE RUDDER COMPARTMENT AND DOUBLE CLAMP ALL NEW HOSES.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Construction/Loadline
Issued 9 May 1988 Resolved
SEAL ALL PENETRATIONS IN WATERTIGHT BULKHEADS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Navigation
Issued 9 May 1988 Resolved
DRILL AND REBUSH THE STEER TRANSFER ARM AND PROVIDE NEW PINS
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 17 April 1987 Resolved
REPLACE FLEXIBLE FUEL LINES.
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987

Ownership record