Records from 1983 to 2014. Most recent: inspection, 13 March 2014.
Inspection history · 96
13 March 2014
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4755333
6 July 2012
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4370000
23 January 2012
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4230267
13 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4207311
7 January 2011
COI Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3922599
6 December 2010
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3905231
23 November 2010
Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3912033
22 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3855078
1 September 2010
Plan Review (Other than "T")
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3839685
3 February 2009
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3412499
15 April 2008
Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3183698
23 October 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3085585
28 September 2007
Hull Examination · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3068218
15 March 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2857448
20 January 2006
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2567881
21 July 2005
Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2433190
15 June 2005
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2426470
31 January 2005
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2282048
4 January 2005
Administrative Inspection · Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2268512
3 February 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1992743
14 August 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1964378
23 May 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1854864
2 May 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1785164
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760260
7 January 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1730296
14 December 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718926
30 October 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1698540
3 October 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1692024
15 July 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1646750
12 March 2002
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1493203
26 February 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489373
13 February 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1484849
23 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073594
1 March 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058003
31 January 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1437841
21 June 2000
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448131
14 June 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819237
15 March 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1047018
10 February 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424864
1 December 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 812502
9 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111875
1 July 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082566
4 May 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130213
18 February 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793826
4 February 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415123
12 November 1998
Hull Examination · Examination of Repairs · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421577
27 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72819
6 September 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803366
8 July 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 118363
29 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130240
26 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789415
3 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1118121
13 February 1998
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436087
1 August 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 7691
7 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1095914
6 February 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411408
17 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1097808
12 April 1996
Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371370
4 March 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422648
9 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150503
19 September 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873258
11 September 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1416182
23 June 1995
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1450984
16 February 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1407432
30 October 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 100847
16 May 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 860393
10 March 1994
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 854910
28 January 1994
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 852794
21 July 1993
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440726
6 July 1993
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 846529
23 June 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1152869
18 February 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1147108
6 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265580
24 May 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 169481
24 April 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415751
3 April 1992
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1012443
23 August 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1243587
2 July 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944054
17 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911562
16 May 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908261
27 February 1991
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1010775
27 February 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1239188
12 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322055
5 June 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995990
10 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307743
12 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293514
20 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990251
9 October 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993374
8 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995985
7 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995987
6 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282533
10 August 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1285133
16 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279561
18 November 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273005
7 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966321
7 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284982
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 March 2014
No resolution recorded
Unable to check prime mover emergency shutdowns due to excessive demand for load. A full set of shutdowns must be conducted w/ABS or USCG at earliest opportunity and a report given to the CG.
Action required: 705 - Other - as specified
Lifesaving › Lifeboat › Markings
Issued 13 March 2014
Resolved
Retro-reflective tape on both L/B's need to be replaced due to excess weathering.
Due 12 April 2014
Resolved 7 April 2014
Lifesaving › Lifeboat › View (at steering position)
Issued 13 March 2014
Resolved
L/B windows are fogged over and reduces visibility. Windows need to be replaced to allow for visibility.
Due 12 April 2014
Resolved 7 April 2014
Lifesaving › Lifeboat › Propulsion Engine
Issued 7 January 2011
Resolved
Launch both lifeboats and operate in the water.
Action required: 705 - Other - as specified
Due 25 January 2011
Resolved 20 January 2011
Resolution: Launched both lifeboats and operated in the water.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 January 2011
Resolved
Repair wire on rig floor light by choke manifold above doorway before commencing drilling operations.
Action required: 705 - Other - as specified
Resolved 28 March 2011
Construction/Loadline › Hull › Bottom Plating
Issued 23 November 2010
Resolved
Complete Phase II (Underwater Exam) no later than February 23, 2011 or upon next rig move, whichever comes first to the satisfaction of the attending ABS surveyor or USCG Marine Inspector.
Due 23 February 2011
Resolved 3 May 2011
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 15 April 2008
Resolved
Vessel did not have approved Emergency Evacuation Plan or approval letter from cognizant OCMI.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 3 February 2009
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 April 2008
Resolved
Service all fire doors to ensure proper operation.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 3 February 2009
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 15 April 2008
Resolved
Verify the integrity of all "Class A" and "Class B" fire boundaries and replace Plexiglas window in company man's office with steel or equivalent material.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 3 February 2009
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 15 April 2008
Resolved
Verfiy sneeze guard on galley serving line does not interfere with installed fire curtain.
Action required: 705 - Other - as specified
Due 15 May 2008
Resolved 3 February 2009
Construction/Loadline › Hull › Side Shell
Issued 28 September 2007
Resolved
Complete Phase II prior to 27 DEC 2007 in the presents of USCG or ABS surveyor.
Due 27 December 2007
Resolved 17 October 2007
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 20 January 2006
Resolved
Run both life boats in the water as soon as weather permits. Test water sprinkler systems in both boats. Properly log quarterly requirement.
Due 1 February 2006
Resolved 22 February 2006
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 January 2006
Resolved
Replace existing retro-reflective material on all life rings with an approved type.
Due 20 February 2006
Resolved 28 January 2006
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 20 January 2006
Resolved
Prove two second on; 18 second off foghorn characteristic.
Due 20 February 2006
Resolved 20 January 2006
Electrical › Lighting (service) › Switch
Issued 20 January 2006
Resolved
Prove the following either alarm or shutdown upon loss of purge: Derrick camera, chart recorder, chart recorder power box.
Due 20 February 2006
Resolved 6 February 2006
Construction/Loadline › Hull › Bottom Plating
Issued 21 July 2005
Resolved
Complete SEILOD Phase II at next rig move.
Due 31 January 2006
Resolved 15 March 2007
Resolution: UWILD Inspection completed 7/29/05. Dive report was on board the vessel.
Construction/Loadline › Structures › Door
Issued 21 July 2005
Resolved
Replace mud pit room overhead hatch cover and crop and renew overhead hatch cover.
Due 19 October 2005
Resolved 20 January 2006
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 31 January 2005
Resolved
Prior to next rig move complete functional test of fixed fire extinguishing systems, equipment shut down pressure operated switches in the presence of the CG inspector or by a third party technical representative.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2005
Resolved 23 March 2005
Resolution: Test satisfactorily completed.
Engineering › Lubricating Oil Service System › Piping
Issued 31 January 2005
Resolved
Determine the source of and repair leak on the vessels stand by generator and clean oil from the generator windings.
Condition: Improper/Lack of Maintenance
Due 2 March 2005
Resolved 14 February 2005
Resolution: Maintenance supervisor repaired leak.
Stability › Watertight Integrity › General
Issued 31 January 2005
Resolved
Repair watertight hatch/door gaskets identified by the CG Inspector.
Condition: Improper/Lack of Maintenance
Due 3 March 2005
Resolved 17 February 2005
Resolution: Deteriorated gaskets were renewed.
Lifesaving › Lifeboat › Canopy
Issued 4 January 2005
Resolved
Complete repairs to damaged canopy , or replace the #2 lifeboat.
Condition: Damaged By Earlier Event
Due 7 January 2005
Resolved 12 January 2005
Resolution: Operator installed refurbished Schatt Harding Life boat.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 31 December 2004
Resolved
Vessel Owner /Operator failed to immediately notify the cognizant OCMI of damage to primary lifesaving equipment IAW 46 CFR 4.05-1(a). (A hole in the canopy of the Port 58 man lifeboat)
Condition: Unknown
Due 3 January 2005
Resolved 3 January 2005
Resolution: Owner/Operator contacted [name withheld] on 3JAN04 to notify of the casualty. POC was advised of the immediate notification requirement and given the MSO Houston 24 hr CDO phone number.
Construction/Loadline
Issued 7 January 2003
Resolved
Repair / renew mud pitroom door, wasted on
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 March 2003
Resolved 6 May 2003
Construction/Loadline › Hull
Issued 30 October 2002
Resolved
Crop and insert mat top plating from 3" aft of Fr. 33 to 4' aft of Fr. 35, from inboard side of mat extension to 19'7" outboard to port; and from Fr. 32 to 2'9" aft of Fr. 33, from the outboard side of the mat to 16'5" inboard to starbiard , along with associated internal structural members. LEGACY COMPONENT DESC: Mat Top Plating
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Witnessed satisfactory repairs to damaged areas.
Construction/Loadline › Hull
Issued 30 October 2002
Resolved
Mat extension bottom plating found distorted between Fr. 33 & Fr. 35 along with internals in way. Crop and insert mat bottom plating from 3" aft of Fr.33 to 2'9" aft of Fr. 34 along with internals in way.
LEGACY COMPONENT DESC: Mat Extension Bottom Plating
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Examined satisfactory renewals to damaged sections of mat extension bottom plating.
Construction/Loadline › Hull
Issued 30 October 2002
Resolved
Inboard side plating of mat extension found distorted between Fr. 33 and 35 along with internals in way. Crop and insert inboard side plating from Fr. 33 to 6" aft of Fr. 35 along with internals in way.
LEGACY COMPONENT DESC: Mat Extension Bottom Plating
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Witnessed satisfactory repairs and testing of plate insert as detailed above.
Construction/Loadline › Hull
Issued 30 October 2002
Resolved
Outboard side plating of mat extension found distorted between Fr. 33 and Fr. 35 along with internals in way. Crop and insert outboard side plating from 1' forward of Fr. 33 to 1'6" aft of Fr. 34 along with internals in way.
LEGACY COMPONENT DESC: Mat Extension Side Plating
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Witnessed satisfactory repairs and testing of inserted area as detailed above.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
Transverse non-tight bulkhead at Fr. 34 found distorted. Crop and renew transverse bulkhead at Fr. 34 along with internals in way.
LEGACY COMPONENT DESC: Transverse Bulkhead
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Witnessed satisfactory renewal of transverse non-tight bulkhead.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
Longitudinal bulkhead in mat extension slightly distorted between Fr. 33 and Fr. 34. Crop and insert longitudinal bulkhead full depth from 12" aft of Fr. 33 to Fr. 34.
LEGACY COMPONENT DESC: Mat Extension Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Witnessed satisfactory renewals in way of damaged area as detailed above.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
Crop and insert wasted aft bulkhead Fr. 16 from 2' above bottom plating to 9' above, from 1' off centerline to starboard, to 10'2" off centerline and from 6' above bottom plating to 9' above, from 10'2" off centerline to starboard, to 30' off centerline. LEGACY COMPONENT DESC: Active Mud Pit Bulkhead
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Repairs were examined upon completion, tested as necessary, and considered satisfactory.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
Crop and renew wasted longitudinal bulkhead at 30' off centerline to starboard from 3" aft of Fr. 16 to 2'9" forward, and from 6; from bottom shell to 9' above.
LEGACY COMPONENT DESC: Active Mud Pit Bulkhead
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Repairs were examined upon completion, tested as necessary and considered satisfactory.
Construction/Loadline › Structures
Issued 30 October 2002
Resolved
Ring girders of the leg columns were found wasted beyond the 25% maximum allowance. Isolated areas were found with wastage up to 37%. Renew ring girder at the 82'3" level on all three (3) leg columns. LEGACY COMPONENT DESC: Leg Column Ring Girders
Action required: 705 - Other - as specified
Due 15 November 2002
Resolved 15 November 2002
Resolution: Ring Gider was renewed as original and found satisfactory.
Electrical › Electrical Distribution System (service)
Issued 13 February 2002
Resolved
PROVE PROPER OPERATION OF THE TOTAL RIG SHUTDOWN FROM ALL STATIONS. LEGACY COMPONENT DESC: Total Rig Shutdown
Due 13 March 2002
Resolved 12 March 2002
Electrical › Electric Supply System (service)
Issued 13 February 2002
Resolved
PROVE PROPER OPERATION OF THE #1, #2, AND #3 GENERATOR REVERSE POWER RELAYS. LEGACY COMPONENT DESC: Reverse Current Protection
Due 13 March 2002
Resolved 12 March 2002
Electrical › Electrical Distribution System (service)
Issued 13 February 2002
Resolved
INSTALL THE PROPER STEEL CABLE CLAMPS, AND REMOVE ALL PLASTIC WIRE TIES FROM THE MUD PIT ROOM. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 13 February 2002
Resolved
REPAIR LEAK TO THE FUEL OIL DAY TANK PIPING LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 13 February 2002
Resolved
REPLACE/REPAIR WASTED FIXED CO2 BOTTLE FOR THE STAND BY GENERATOR. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 13 February 2002
Resolved
REPAIR/REPLACE DAMAGED STARBOARD ESCAPE LADDER. LEGACY COMPONENT DESC: Hand Grab
Condition: Unknown
Due 13 March 2002
Resolved 12 March 2002
Construction/Loadline › Structures
Issued 13 February 2002
Resolved
CROP AND RENEW BACK TO GOOD STEEL, WASTED SECTION OF THE BULKHEAD IN THE RECREATION ROOM. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Construction/Loadline › Structures
Issued 13 February 2002
Resolved
CROP AND RENEW BACK TO GOOD STEEL, HOLED SECTION IN HATCHWAY TO SACKROOM. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Construction/Loadline › Structures
Issued 13 February 2002
Resolved
REPAIR/REPLACE WASTED FUEL OIL VENT ON THE STARBOARD SIDE. LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 13 March 2002
Resolved 12 March 2002
Electrical
Issued 31 January 2001
Resolved
Refit explosion proof light fixture on drill floor sub structure on port side.
Condition: Unknown
Due 6 June 2001
Resolved 8 June 2001
Lifesaving
Issued 31 January 2001
Resolved
Provide evidence of the replacement of all liferaft hydrostatic release units.
Condition: Unknown
Due 5 February 2001
Resolved 8 June 2001
Lifesaving
Issued 31 January 2001
Resolved
Test relief valves on all air receivers to the satisfaction of attending Coast Guard Inspector.
Condition: Unknown
Due 2 March 2001
Resolved 8 June 2001
Construction/Loadline
Issued 31 January 2001
Resolved
Make repairs to emergency generator compartment; seal all hoses and pipe passages, replace wasted plating.
Condition: Unknown
Due 2 March 2001
Resolved 8 June 2001
Lifesaving
Issued 31 January 2001
Resolved
Provide evidence of the replacement of the starboard lifeboat.
Condition: Unknown
Due 2 March 2001
Resolved 8 June 2001
Construction/Loadline
Issued 21 June 2000
Resolved
CONDUCT PHASE II UNDERWATER EXAM AND SUBMIT DIVE REPORT AND GUAGE REPORT TOOCMI MORGAN CITY. ALSO PROVIDE FOR CLASS OR COAST GUARD INSPECTION OF REPAIRS IN WAY OF SACK ROOM DECK AND SCR ROOM.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 21 June 2000
Resolved
PROVIDE REPORT OF INSPECTION FROM ABS FOR ALL THROUGH HULL VALVES, OR MAKE AVAILABLE FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 10 February 2000
Resolved
PROVIDE HEAVY ENOUGH LIFERING AT SMOKE STATIONS SO THAT THE SMOKE AND LIGHTWILL AUTOMATICLLY DEPLOY.
Condition: Unknown
Due 24 February 2000
Resolved 25 February 2000
Fire Fighting
Issued 10 February 2000
Resolved
CROP AND RENEW FIREMAIN PIPING ON DRILL FLOOR WHERE WASTED.
Condition: Unknown
Due 10 March 2000
Resolved 25 February 2000
Lifesaving
Issued 10 February 2000
Resolved
CONDUCT 1.1 WEIGHT TEST OF LIFEBOAT DAVITS FOR BOTH BOATS.
Condition: Unknown
Due 24 February 2000
Resolved 25 February 2000
Construction/Loadline
Issued 10 February 2000
Resolved
REPAIR AND ENSURE PROPER OPERATION OF WATERTIGHT DOORS THROUGHOUT RIG AS NECESSARY. REPLACE WASTED FLANGE ON WATERTIGHT DOOR TO FORWARD LEG.
Condition: Unknown
Due 10 March 2000
Resolved 25 February 2000
Lifesaving
Issued 10 February 2000
Resolved
RENEW DRIVER'S WINDOW AND VIEWING PORTS ON BOTH LIFEBOATS. ARREST CORROSIONON AFTER RELEASE BAR ON BOTH LIFEBOATS.
Condition: Unknown
Due 10 March 2000
Resolved 25 February 2000
Lifesaving
Issued 4 February 1999
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF THE RELEASE GEAR ON BOTH LIFEBOATS IN ACCORDANCE WITH 46CFR109.301(i)(5).
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Unknown
Issued 4 February 1999
Resolved
REPLACE THE TWO CRACKED WINDOWS ON PORT CRANE.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Deck/Cargo
Issued 13 February 1998
Resolved
Replace the pressure relief valves on bulk tanks #4 barite, and # 1and #2 cement tanks with valves set at no more than 45 psi. Replacement valves must be ASME coded valves (stamped with "U" or "UV" insignia).
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Fire Fighting
Issued 13 February 1998
Resolved
Repair main fire pump/saltwater pump.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Lifesaving
Issued 13 February 1998
Resolved
Replace corroded helicopter deck perimeter safety netting and wire rope. Ensure adequate securing of new netting to wire rope and stanchions.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Documentation
Issued 13 February 1998
Resolved
Demonstrate compliance with the 1996 edition of 46 CFR 109.213 "Emergency Training and Drills". Must develop and implement abandon rig training maiual and conduct and log training and drills as required.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Lifesaving
Issued 13 February 1998
Resolved
Repair or replace the following lifeboat items: #1 (stbd) lifeboat, a) replace expired aspirin in first aid kit, b) replace expired smoke signals,c) add one additioal 3-cell flashlight; #2 (port) lifeboat, a) clean oil from bilges, replace bilge suction hose, b) replace expired smoke signals
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Deck/Cargo
Issued 13 February 1998
Resolved
Repair mud pit room exhaust fan loss-of-ventilation alarm. NOTE: Alarm mustdetect ventilation flow or loss of relative negative pressure in mud pit room; also alarm must be wired independently of ven van motor controller.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Accommodation/Occupational Safety
Issued 13 February 1998
Resolved
Fabricate or procure and mount a placard on the marine sanitation device (MSD) that contains the operating instructions (including proper chemical solution mixture, drip rate adjustment and safety precautions for handling chemicals). See 33 CFR 159.59 for required placard content.
Condition: Unknown
Due 29 May 1998
Resolved 29 May 1998
Accommodation/Occupational Safety
Issued 6 February 1997
Resolved
VERIFY OPERATION OF ALL SMOKE DETECTORS; PROVIDE BUNK LIGHT COVER, RM. 34; REPLACE BROKEN CEILING TILES AS NECESSARY.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997
Resolved
MAKE MUD PIT DOORS SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 6 February 1997
Resolved
REPAIR GENERAL ALARM IN SHAKER HOUSE.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 6 February 1997
Resolved
MAKE EQUIPMENT AND POLICY CHANGES IAW NEW REVISIONS TO 46 CFR 107-109.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Electrical
Issued 6 February 1997
Resolved
PERFORM SEMIANNUAL 2 HR. EMERGENCY BATTERY LOAD TEST AND LOG.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Lifesaving
Issued 4 March 1996
Resolved
MAKE BRAKE COUNTERWEIGHTS ON LIFEBOATS OPERATE PROPERLY (COUNTERWEIGHT ON STBD BOAT GOES TOO FAR, WILL NOT SET BRAKE WHEN RELEASED AND PORT BOAT DOESNOT SET BRAKE WHEN RELEASED).
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
INVESTIGATE, DRAFT, PRINT AND POST DETAILED INSTRUCTIONS FOR SETUP OF EMERGENCY GENERATOR IN (1) NORMAL AUTOMATIC SETUP FOR EMERGENCY START/BUS TRANSFER,(2) TESTING OF AUTO START/TRANSFER, AND (3) SETUP FOR FEEDBACK TO MAIN SWITCHBOARD. LABEL ALL ASSOCIATED BREAKERS AND SWITCHES.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Lifesaving
Issued 4 March 1996
Resolved
RENEW RING BUOY HOLDER AT FORWARD END OF PIPERACK DECK.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Fire Fighting
Issued 4 March 1996
Resolved
RELOCATE FIRE STATION #14 TO AN AREA CLEAR OF OBSTRUCTIONS OR REMOVE SCRAP STEEL FROM IN FRONT OF THE FIRE STATION.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
REPAIR WEAK BATTLE LANTERNS IN SHOWER AREA LOWER QUARTERS AND IN FORWARD LEG COMPARTMENT.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Documentation
Issued 4 March 1996
Resolved
PROVIDE SUBSTANCE ABUSE EMPLOYEE ASSISTANCE PROGRAM (EAP) IN ACCORDANCE WITH 46 CFR 16.401.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
REPLACE BROKEN EXPLOSION PROOF JUNCTION BOX ON SIDE OF BARITE HOPPER IN MUDPIT ROOM (BROKEN COVER AND MOUNTING BRACKETS).
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Accommodation/Occupational Safety
Issued 4 March 1996
Resolved
REPAIR OR REPLACE MUDPIT TO SACKROOM DOOR WHERE WASTED AT DOOR BOTTOM AND SILL. REPAIR MUDPIT TO PUMPROOM DOOR TO MAKE SELF-CLOSING.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
REPAIR AND PROVE PROPER OPERATION OF #1 SHIP SERVICE DIESEL GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Construction/Loadline
Issued 4 March 1996
Resolved
REPLACE IMPROPER WATERTIGHT DOOR GASKET MATERIAL (OPEN CELL SOFT WEATHER STRIPPING TYPE) WITH CORRECT MATERIAL (CLOSED CELL HARD RUBBER) WHERE NEEDED ON BELOW DECK WATERTIGHT DOORS.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Fire Fighting
Issued 4 March 1996
Resolved
REPAIR AND PROVE PROPER OPERATION OF FIRE SHUTTER DOORS IN GALLEY.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
LOSS OF VENTILATION ALARMS FOR HAZARDOUS AREAS AND ADJACENT AREAS (MUDPIT ROOM, SACK ROOM, PUMP ROOM) MUST BE WIRED INDEPENDENTLY OF THE FAN MOTOR CONTROLLERS.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Documentation
Issued 4 March 1996
Resolved
ALL STATION BILLS THROUGHOUT RIG MUST BE REVIEWED AND SIGNED BY OIM'S FOR BOTH HITCHES.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Electrical
Issued 4 March 1996
Resolved
INCORPORATE CLOSURE OF ROLLER TYPE DOOR ON STANDBY GENERATOR ROOM INTO CO2 ACTIVATION INSTRUCTIONS AT ACTUATING STATION AND PROVIDE ADEQUATE COVERS FOR EXHAUST FAN DUCTS IN ACCORDANCE WITH 46 CFR 108.455.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Fire Fighting
Issued 4 March 1996
Resolved
PROVIDE ENGINE ROOM HALON FIRE EXTINGUISHING SYSTEM WITH MORE DETAILED INSTRUCTIONS, COLOR CODING OR NUMBERING OF THE RELEASE/CHARGING VALVES AND POSTING OF SPECIFIC DIRECTIONS (ACTUAL COMPARTMENT NAME) WHERE THE SYSTEM CAN BE ACTUATED IN CASE OF FAILURE OF THE REMOTE ACTUATOR.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Lifesaving
Issued 4 March 1996
Resolved
MAKE GENERAL ALARM BELL IN SHAKER AREA WORK PROPERLY AND PROPERLY MARK WITH"GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION".
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Lifesaving
Issued 4 March 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Fire Fighting
Issued 4 March 1996
Resolved
REPAIR OR REPLACE SMOKE DETECTORS IN ROOM #19 TOILET/SHOWER AND IN HOT WATER HEATER ROOM IN LOWER QUARTERS AREA.
Condition: Unknown
Due 4 March 1996
Resolved 4 March 1996
Construction/Loadline
Issued 23 June 1995
Resolved
CONDUCT PHASE THREE (BOTTOM INSPECTION VIA VIDEO/DIVERS) OF MAT BOTTOM IN THE PRESENCE OF US COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Construction/Loadline
Issued 23 June 1995
Resolved
MAKE ALL THREE MUD PIT DUMP VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 23 June 1995
Resolved 23 June 1995
Fire Fighting
Issued 10 March 1994
Resolved
RENEW FLEX HOSE ON PORTABLE FIRE EXTINGUSHER AS NOTED ON FIRE SERVICE REPORT.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Lifesaving
Issued 10 March 1994
Resolved
COMPLETE REPAIRS AS ON PORT LIFE BOAT ENGINE, AND TEST WITH LIFE BOAT SYSTEMS.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Fire Fighting
Issued 10 March 1994
Resolved
HYFRO TEST THE SIX PORTABLE FIRE EXTINGUISHERS AS NOTED ON FIRE SERVICE REPORT.
Condition: Unknown
Due 10 March 1994
Resolved 10 March 1994
Deck/Cargo
Issued 21 July 1993
Resolved
OPEN MUD PIT DUMP VALVES FOR INSPECTION.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Construction/Loadline
Issued 21 July 1993
Resolved
OPEN & GAS FREE DRILL WATER TANK #10 STBD FOR CG INSPECTION.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Construction/Loadline
Issued 21 July 1993
Resolved
CONDUCT BOTTOM MAT SWIM-BY TO CONCLUDE U/W PORTION OF SEILOD IN PRESENCE OFCG INSPECTOR.
Condition: Unknown
Due 21 July 1993
Resolved 21 July 1993
Documentation
Issued 23 August 1991
Resolved
PROVIDE ONBOARD A USCG MARINE SAFETY CENTER APPROVED CONSTRUCTION PORTFOLIO
Condition: Unknown
Due 23 August 1991
Resolved 23 August 1991
Documentation
Issued 27 February 1991
Resolved
PROVIDE EVIDENCE/COPY OF CURRENT LOAD LINE CERTIFICATE
Condition: Unknown
Due 27 February 1991
Resolved 27 February 1991
Construction/Loadline
Issued 9 October 1985
Resolved
CONDUCT AN UNDERWATER VIDEO EXAMINATION OF THE MATLEGS AND LEG TO MAT CONNECTIONS REF46CFR107.207
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Construction/Loadline
Issued 9 October 1985
Resolved
MAKE THE TWO DOORS TO THE MUD PIT ROOM SELF CLOSING AND GAS TIGHT 46CFR108.175
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Electrical
Issued 9 October 1985
Resolved
INSTALL LAGGING ON THE EMERGENCY GENERATOR DIESEL EXHAUST MANIFOLD. REF46 CFR58-10-10
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Electrical
Issued 9 October 1985
Resolved
INSTALL LAGGING ON THE #1,#2 AND #3 MAIN GENERATOR DIESEL EXHAUST MANIFOLDSREF 46CFR58-10-10.
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Unknown
Issued 9 October 1985
Resolved
PROVIDE A RELIEF VALVE WITH A RELIEVING DEVICE, ON NO. 1 TANK. 46CFR54.15 10(C).
Condition: Unknown
Due 9 October 1985
Resolved 9 October 1985
Deck/Cargo
Issued 6 November 1984
Resolved
MAKE SUITABLE FOR HAZARDOUS LOCATION THE DESILTER MOTOR CONTROLLER OF THE SHALL SHAKER AREA. 46CFR111.92.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Construction/Loadline
Issued 6 November 1984
Resolved
PROVIDE CLASS-A CLOSURES FOR THE VENTILATION OPENINGS TO THE EMERGENCY GENERATOR SPACE 46CFR108.139.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
REPAIR OR REPLACE THE STARBOARD CEMENT TANK RELIEF VALVE 46CFR54.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Electrical
Issued 6 November 1984
Resolved
REPAIR THE LOSS OF VENTILATION ALARM IN THE MUD PIT ROOM 46CFR111.92.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Navigation
Issued 6 November 1984
Resolved
PROVIDE (1) ANCHOR LIGHT (COLREGS)
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Construction/Loadline
Issued 6 November 1984
Resolved
REPAINT VESSEL'L LOADLINE AND DRAFT MARKS 46CFR108.661.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
PROVIDE API HAND SIGNAL CHART FOR STARBOARD CRANE. 46CFR108.601
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
REPAIR GENERAL ALARM BELL IN VICINITY OF SHALE SHAKEN AREA 46CFR 113.25.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Lifesaving
Issued 6 November 1984
Resolved
PROVIDE OPERATING INSTRUCTION FOR LINE THROWING GUN. 46CFR108.511.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Navigation
Issued 6 November 1984
Resolved
PROVIDE (2) TWO BLACK BALLS AND (1) ONE DIAMOND SHAPE (COLREGS).
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
PROVIDE A HAND RELIEVING DEVICE TO THE DRILL FLOOR AOR RECEOVER 46CFR54.15
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 6 November 1984
Resolved
PROVIDE EVIDENCE TO [name withheld], LA THAT BOTH CRANES HAVE HAD QUADRENNIAL AND ANNUAL EXAMS BY APPROVED ISSUANCE AGENT IN ACCORDANCE WITH API SPECS 46 CFR 109.439.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 6 November 1984
Resolved
SUBMIT CONSTRUCTION PORTFOLIO TO [name withheld] FOR REVIEW AND APPROVAL 46 CFR 107.305.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
PROVIDE VALVES TO ALL BILGE MANIFOLD SUCTIONS 46CFR56.50-50/
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Deck/Cargo
Issued 6 November 1984
Resolved
MAKE SUITABLE FOR DIVISION II HAZARDOUS LOCATIONS THE DRILL FLOOR PORTABLE EQUIPMENT PLUGS. 46CFR111.92.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Fire Fighting
Issued 6 November 1984
Resolved
PROVIDE RELIEF VALVE FOR PAINT LOCKER. 46CFR108.457
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Lifesaving
Issued 6 November 1984
Resolved
RESTENCIL LIFEBOAT MARKINGS FOR LIFEBOATS #1 AND #2 (CAPACITY HOMEPORT BOATNUMBER RELEASING GEAR). 46 CFR 108.645.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Lifesaving
Issued 6 November 1984
Resolved
PROVIDE (12) TWELVE HAND HELD FLARES FOR EACH LIFEBOAT (#1 AND #2) 46 CFR 108.503.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Lifesaving
Issued 6 November 1984
Resolved
RENEW RUBBER GASKETS ON LIFEBOAT DOORS (#1 AND #2 LIFEBOATS) 46 CFR 108.503
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Lifesaving
Issued 6 November 1984
Resolved
PROVIDE ONE (1) FISHING KIT FOR LIFEBOAT #2 (TWO) 46 CFR 108.503.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 6 November 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL SABINE III, DN634728 AND ARE TO BE COMPLIED WITH BY 06DEC84.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 7 October 1983
Resolved
REPAIR OR REPLACE THE BATTERY BOXES IN BOTH CRANES.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
PLACE ON BOARD OIL POLLUTION PLACARDS AS APPROPRIATE.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
COMPLETE THE UNDERWATER EXAMINATION IN LIEU OF DRYDOCKING IN WAY OF THE MATTO LEG CONNECTIONS, AND THE MAT SKIRT, TOP AND BOTTOM.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
REPAIR THE MAGNETIC TRIP ON THE VENTILATION "A" SHUTDOWN CIRCUIT BREAKER.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
PROVIDE INTERIOR LIGHTING FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
PROVIDE DOCUMENTATION OF CERTIFIED TENSIL/BREAKING STRENGTH OF THE AUX- ILIARY LINE FOR THE SHOULDER LINE THROWING GUN.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
CONDUCT FIRE AND ABANDON RIG DRILLS IN THE PRESENCE OF A U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE SABINE III, DN634728.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
REVISE, UPDATE AND RESUBMIT FOR U. S. COAST GUARD APPROVAL THE VESSEL'S FIREFIGHTING AND LIFESAVING PLAN.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983
Unknown
Issued 7 October 1983
Resolved
PROVIDE ON BOARD U. S. COAST GUARD APPROVED FIXED FIREFIGHTING SYSTEMS PLANS.
Condition: Unknown
Due 7 October 1983
Resolved 7 October 1983