MAURY USCG vessel records
← All vessels

KON TIKI II

KON TIKI II is a 1980 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2016, most recently in July 2026, along with 59 deficiencies — 2 with no resolution recorded — and 5 casualty investigations between 2012 and 2014.

Records from 2012 to 2026. Most recent: inspection, 23 July 2026.

Built
1980
Last inspected
23 July 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 July 2026
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDF6312
Flag
UNITED STATES
Maury page id
psix-52457

Documentation record

Registered dimensions (L × B × D)90.0 ft × 32.7 ft × 6.7 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN REEVE · ST THOMAS, PR, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST THOMAS US, VI
Trade endorsementsRegistry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

23 July 2026 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8445063
22 June 2026 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8410186
28 April 2025 Administrative Inspection · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8038566
15 May 2024 Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7913091
8 April 2024 Drydock Exam · Examination of Repairs · Administrative Inspection · Damage Survey · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7891793
11 September 2023 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7789507
13 June 2023 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7713807
12 June 2023 In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7713023
8 September 2022 MTSA Verification · Annual Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7543940
1 March 2022 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7403896
10 June 2021 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7195725
18 November 2020 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7097453
19 August 2020 Drydock Extension · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7037375
7 November 2019 Administrative Inspection · DAPI Audit · MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6857349
6 December 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6592969
21 September 2018 Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6537689
14 March 2018 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6373056
9 November 2017 MTSA Verification · Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6303852
13 October 2016 DAPI Audit · COI Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6021956
16 September 2016 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6001552
15 March 2016 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5833544

Deficiency record · 59

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2026 No resolution recorded
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (a) Operation of the main propulsion machinery both ahead and astern. Vessel operator reported the KON TIKI II suffered a starbard main engine exhaust manifold and turbocharger failure rendering the starboard main engine inoperable. 46 CFR 115.804
Action required: 705 - Other - as specified
14 - Pollution Prevention › 143 - MARPOL Annex III › Other (MARPOL Annex III)
Issued 22 June 2026 No resolution recorded
Key personnel must complete training in 33CFR101.650(d)(2) by January 12, 2026. Company does not have a CYSO and all key personnel have not yet completed the training as of this inspection. 33 CFR 101.650(d)(4)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 August 2026 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 April 2025 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the tank compartment, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the compartment and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Electric solenoid valves must not be used, unless used in addition to the manual valve. The stbd engine fuel shutoff valves did not effectively close the valves (code 17). The shutoff valves were adjusted and functioned appropriately during inspection.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2025
Resolution: The shutoff valves were adjusted and functioned appropriately during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 April 2025 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces: 1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and(3) A space with a non-watertight closure , such as a space with a non-watertight hatch on the main deck. The port engine room high level alarm was inoperable (code 17). The high level alarm was replaced and functioned appropriately.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2025
Resolution: The high level alarm was replaced and functioned appropriately.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 April 2025 Resolved
Notwithstanding any other provision of this subpart, except as provided in paragraph (b) of this section, a Certificate of Documentation but no trade endorsement thereon, issued to a vessel which is the subject of an outstanding mortgage filed or recorded in accordance with subpart Q of this part or any predecessor regulations, remains valid for purposes of:(1) 46 U.S.C. chapter 125;(2) 46 U.S.C. chapter 313 for an instrument filed or recorded before the date of invalidation, and an assignment or a notice of claim of lien filed after that date;(3) 46 U.S.C. 56101, 56102 and 57109; and(4) 46 U.S.C. 56301. The vessel possess a valid COD, but it was not onboard the vessel. The COD was printed and placed onboard.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2025
Resolution: The COD was printed and placed onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 April 2025 Resolved
Each vessel owner or operator subject to this part must ensure that copies of the following documents are carried on board the vessel and are made available to the Coast Guard upon request:(1) The approved Vessel Security Plan (VSP) and any approved revisions or amendments thereto, and a letter of approval from the Commanding Officer, Marine Safety Center (MSC). The vessel possess a valid VSP letter of approval, but it was not onboard the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 12 May 2025
Resolution: The VSP was printed and placed onboard the vessel.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 28 April 2025 Resolved
Each garbage management plan under paragraph (a) of this section must be in writing and—(1) Provide for the discharge of garbage by means that meet Annex V of MARPOL, the Act, and §§ 151.51 through 151.77;(2) Describe procedures for minimizing, collecting, processing, storing, and discharging garbage; and(3) Designate the person who is in charge of carrying out the plan. The vessel possess a waste management plan template, but it was not filled out.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 12 May 2025
Resolution: The garbage management plan was filled in and signed by the vessel master.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 April 2025 Resolved
If the marine employer conducts random drug testing through a consortium, the number of crewmembers to be tested may be calculated for each individual marine employer or may be based on the total number of covered crewmembers covered by the consortium who are subject to random drug testing at the same minimum annual percentage rate under this part or any DOT drug testing rule. Documentation showing which employees are a part of the consortium was not present on the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 12 May 2025
Resolution: DAPI information was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 April 2025 Resolved
Each life jacket carried on board the vessel must be marked in accordance with § 122.604 of this chapter. Numerous life jackets have inoperable retro reflective tape. Inspect all life jackets and replace retro reflective tape as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 May 2025
Resolved 12 May 2025
Resolution: The retro reflective tape was replaced on the required life jackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 April 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;(c) Minimize accidental personnel contact with energized parts. Unconnected and unprotected wires were present at the helm and hot water heater. There is an opening in the main circuit breaker panel. There are opening in the storage room electrical outlet and at the galley stbd electrical outlet. These issued were corrected.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2025
Resolution: The dead end wires were capped and the openings on the circruit breaker panel and electrical outlets were covered.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 April 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Crewmember punctured port engine room hull plating during maintenance corrosion removal creating a quarter-sized hole in the bottom plating and water intrusion. Temporary repair was made and haulted water intrusion. Provide hull gauging report for the port engine room bottom plating and submit with repair proposal to USCG for review and plan approval prior to making permanent repairs. 46 CFR 176.700
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2024
Resolved 28 April 2025
Resolution: Repairs to the staisfaction of the Coast Guard verfied during COI exam on 28APR25.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 April 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: Operation of the main propulsion machinery both ahead and astern. Vessel suffered a water pump failure on the starboard main engine. Repair or replace in-kind and conduct satisfactory sea trials in the presence of USCG marine inspectors. 46 CFR 176.804
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2024
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 September 2023 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Stbd fuel tanks remote shutoff valve did not operate from outside the space, make necessary corrections. 46 CFR 119.455(b)(3)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2023
Resolved 26 September 2023
Resolution: Satisfactory repair was made
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operations. Fuel shutoff stations markings were not as required, make necessary corrections. 46 CFR 122.608
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 25 September 2023
Resolution: Marked as required
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 September 2023 Resolved
The installation of fuel lines, including pipe, tube, and hose, must comply with the requirements of this paragraph Fuel lines must be accessible, protected from mechanical injury, and effectively secured against excessive movement and vibration. Stbd fuel line between tank and bulkhead had small fuel leak. Make necessary corrections. 46 CFR 119.455(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 25 September 2023
Resolution: Made necessary repair
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 September 2023 Resolved
The Certificate of Inspection and Stability Letter must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI and Stability Letter were not posted as required. Post both as required. 46 CFR 115.302 46 CFR 115.306
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 25 September 2023
Resolution: Certs posted as required
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 September 2023 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure , such as a space with a non-watertight hatch on the main deck. (b) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Label for bilge alarm was missing at operating station for stbd aft compartment. Label alarm as required. 46 CFR 119.530(a),(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2023
Resolved 26 September 2023
Resolution: Missing label was created
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 11 September 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Marine Navigation Lights,” or other standard specified by the Commandant. Nav light missing bulb; Replace bulb as required. 46 CFR 120.420
Action required: 705 - Other - as specified
Due 25 September 2023
Resolved 26 September 2023
Resolution: P/S Nav lights corrections were made
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. MI's observed a AGM battery supplying the rum punch machine behind the bar not affixed in a suitable container. 46CFR 120.220 (a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited. AGM battery supplying rum punch machine was found to be utilizing pressure clamp type connections. 46CFR 120.350 (d)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 12 June 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI's observed excessive corrosion at fire hose connection to the fire main on the main deck. Vessel must disconnect hoses from fire main and lubricate to allow for quick disconnection for hose transfer in the event of an emergency. 46CFR 115.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 June 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. MI's observed a 120v electrical outlet not properly affixed and without a cover in the bar storage area on the starboard side. Vessel must properly install the outlet. 46CFR 120.220(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI's observed a fluorescent light fixture in the bar area without a cover. 46CFR 120.200(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment used in the following locations must be dripproof; A location normally exposed to splashing, water washdown, or other wet conditions within a galley, a laundry, or a public washroom or toilet room that has a bath or shower. MI's observed non-dripproof connections in the electrical locker that has open communication to sea from below the locker. 46CFR 120.210(a)(2)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI's observed an upper deck drainage pipe that runs through the main deck electrical closet. As a best practice this configuration shall be changed to re-route the plumbing in a manner that would protect the electrical components from failure in the event of a leak. 46CFR 120.200(b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2023 Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the cognizant [name withheld] fire extinguisher behind bar was not permanently mounted. Vessel must suitably mount extinguisher in the appropriate location. 46CFR 118.520
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023 Resolved
Electrical equipment used in the following locations must be dripproof; A location normally exposed to splashing, water washdown, or other wet conditions within a galley, a laundry, or a public washroom or toilet room that has a bath or shower. Electrical closet in galley had loose wiring penetrating a non-dripproof electrical box. Vessel must make connections dripproof 46CFR 120.210(a)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2023
Resolved 11 September 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 September 2022 Resolved
During the test of the port engine room fire boy suppression system the engine shut down as required but failed to provide an audible alarm at the operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: Observed satifactory test of port and starboard engine room fireboy surpression systems with audible alarms heard at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2022 Resolved
At the time of the inspection attending MI's noted that the bilge pump screens at each pick up point were removed. Restore to original configurations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: Observed new screens installed on bilge suction pickups.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 September 2022 Resolved
Attending MI's observed waste oil being retained in a cooler in the after most void on the port side. Properly dispose of oil and establish future plans to retain and dispose of generated oil on board the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: Crew said oil filled cooler was removed and the attending MIs did not find any evidence of oil retention in coolers on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 September 2022 Resolved
A pair of vice grips was noted holding a sea strainer together in the starboard engine room. Restore to manufacture design for function.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: Observed sea strainer collar was fitted with tensioner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 September 2022 Resolved
At the time of the inspection no freshwater was available to test the bilge pump. Prior to operations with passenger prove satisfactory operations of the installed bilge pumping arrangements.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: Observed satisfactory operation of installed bilge pumping arrangements in port aft and forward voids and starboard aft and forward voids.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 8 September 2022 Resolved
Attending MI's noted that excessive debris was observed in all void. Old parts, tarps and operational supplies should be secured proper as to not affect the emergency bilge pumping arrangements.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2022
Resolved 11 October 2022
Resolution: All of the forementioned debris and parts were removed from the vessel.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 1 March 2022 Resolved
Vessel is restricted to the carriage of not more than one hundred and fifty (150) passengers for hire until a satisfactory MTSA Verification exam is done. Company must also complete satisfactory security drills and a company security exercise with vessel crews as well as show proof of compliance with security training and proficiency for the CSO and VSO.
Action required: 705 - Other - as specified
Resolved 14 March 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2019 Resolved
Anchor light is missing and port nav light is inop.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2019
Resolution: All around light installed
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 November 2019 Resolved
Provide EPIRB or survival craft as required. Each vessel certificated to operate on a limited coastwise route within three miles of land in warm water, and is equipped with an FCC type accepted Category 1 406 MHz EPIRB installed to float free and automatically activate, is not required to carry survival craft.
Action required: 705 - Other - as specified
Due 21 November 2019
Resolved 9 December 2019
Resolution: Vessel does not operate on the high seas and does not require primary lifesaving or an EPIRB because it meets subdivision.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 November 2019 Resolved
Properly mark fire fighting system manual activation pulls and provide operating instructions. Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2019
Resolution: Instructions posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2019 Resolved
Fix valve on stbd side raycor. There are vice grips as a handle.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2019
Resolution: Valve replaced
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 November 2019 Resolved
Crew did not know that there is a manual pull for the preengineered firefighting system and how to operate it.
Action required: 10 - Deficiency Rectified
Resolved 9 December 2019
Resolution: Prior to the end of the inspection, conducted training with the vessel crew and ensured they knew how to use the pre-engineered fire fighting system and where all the components were located.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 November 2019 Resolved
Make proper repairs to port side expansion tank. Currently repaired with JB Weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2019
Resolution: Proper repairs effected
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2019 Resolved
Provide hose clamps on Port & Stbd oil vapor canisters.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 November 2019 Resolved
Both stern tubes to be gauged/closely inspected at the next drydock for wastage / possible replacement.
Action required: 705 - Other - as specified
Due 31 March 2020
Resolved 18 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 December 2018 Resolved
Prove proper operation of port and starboard bilge pumping system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 7 December 2018
Resolution: Proper operation witnessed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 6 December 2018 Resolved
Re-position and prove proper operation of lazarette high bilge alarms.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Floats installed satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 December 2018 Resolved
Provide means of shutting down generators automatically when fixed fire systems are activated.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Shutdowns working satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 December 2018 Resolved
Remove flammable stores or meet requirements of 46CFR 116.600, 118.400 & 120.530.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Flammables removed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 December 2018 Resolved
Replace starboard fire-boy cylinder or provide documentation from service technician attending to the satisfactory condition of corrosion and pitting on cylinder.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Received letter from service technician attesting to satisfactory condition.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 December 2018 Resolved
Provide manufactures documentation to indicate proper installation of dripless shaft seals.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 December 2018
Resolution: Received letter from manufacturer attesting to proper operation.
Construction/Loadline › Hull › Bottom Plating
Issued 14 March 2018 Resolved
Crop and renew holed bottom plate in way of starboard bow rake.
Action required: 705 - Other - as specified
Due 30 March 2018
Resolved 20 March 2018
Resolution: Permanent repairs made. NDT found satisfactory.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 November 2017 Resolved
Post COI, Stability Letter and Emergency Instructions.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: All documents properly posted.
Navigation › Piloting/Steering › Marine Charts
Issued 9 November 2017 Resolved
Provide updated navigational charts.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Updated charts on board.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 November 2017 Resolved
Remove sharp edges on upper deck in the forward starboard rail.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Sharp edges properly eliminated.
Electrical › Electric Supply System (service) › Battery Charger
Issued 9 November 2017 Resolved
Properly mount battery chargers and air compressor.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Battery chargers properly mounted.
Electrical › Electrical Distribution System (service) › Cable
Issued 9 November 2017 Resolved
Properly mount and wire engine room fans.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Engine room fans properly mounted.
Documentation › Markings/Placards › Warning Signs
Issued 9 November 2017 Resolved
Properly label emergency fuel shut-off valves.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Placards posted
Communications › Radio Communications › Emergency Source of Power
Issued 9 November 2017 Resolved
Provide reserve power supply for vessel VHF radios.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 21 November 2017
Resolution: Emergency source of power installed.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 November 2017 Resolved
Provide marine radar.
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 28 November 2017
Resolution: Exemption for radar requirment, see P letter P 529-17.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 November 2017 Resolved
Prove proper operation of emergency fuel shut-offs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 November 2017
Resolved 21 November 2017
Resolution: Fuel shut-offs properly labeled.
Documentation › Markings/Placards › Garbage Placard
Issued 14 October 2016 Resolved
Provide MARPOL V placard.
Action required: 705 - Other - as specified
Due 1 November 2016
Resolved 2 November 2016
Resolution: MARPOL V posted.

Casualty record · 5

26 May 2012Routine · role: Involved in a Marine Casualty · activity 4328411
12 June 2012Routine · role: Involved in a Marine Casualty · activity 4342938
10 July 2012Routine · role: Involved in a Marine Casualty · activity 4404165
28 August 2012Routine · role: Involved in a Marine Casualty · activity 4425298
6 January 2014Routine · role: Involved in a Marine Casualty · activity 4778737
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.