Records from 2016 to 2026. Most recent: inspection, 14 May 2026.
Documentation record
Registered dimensions (L × B × D)41.5 ft × 13.8 ft × 6.8 ft
Registered tonnagegross 23 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST AUGUSTINE BOAT WORKS · ST AUGUSTINE, FL, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
14 May 2026
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8372843
12 May 2025
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8132958
18 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004699
17 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7896741
28 February 2023
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644534
20 October 2022
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7581072
22 February 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7399854
24 March 2021
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7163225
11 September 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7057793
14 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6938989
1 April 2019
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6653465
12 October 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559813
4 April 2018
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6383905
29 March 2017
DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6113872
12 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6020692
17 May 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5879254
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Electronic and paper charts have not been updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: new electronic chart installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel has not completed and logged monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: log created.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 May 2025
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant [name withheld] were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: hatches properly labled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 February 2023
Resolved
Observed sagging deck on port and starboard main deck in way of port and starboard doors on forward side of the vessel near the operating station. Make proper repairs to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2023
Resolution: cropped and renewed FRP/plywood deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 March 2021
Resolved
Water intrusion from port aft deck into lazz. Repair caulking from deck above lazz. port side
46CFR176.802(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2021
Resolution: Vessel provided repair pictures addressing the correction of the deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 April 2019
Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. Mutiple first aid kit items are expired. - 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Provided proof of new first aid kit.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 4 April 2018
Resolved
Lable Storage as "Distress Signals"
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Storage box labled properly as Distress Signals.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018
Resolved
Bilge pump wiring located below bilge pump float switch.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Bilge pump wiring relocated above bilge pump float switch.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 April 2018
Resolved
Child lifejackets stored with adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Child lifejackets provided with separate storage from adult lifejackets.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 April 2018
Resolved
Inspectors unable to verify company is conducting DAPI for employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 12 April 2018
Resolution: Inspectors verified company is conducting DAPI for all employees.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2018
Resolved
Replace battery cable (exposed wiring).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Vessel provided acceptable objective evidence that battery cables were properly insulated at terminal connection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 April 2018
Resolved
Battery connections were not of permanent type.
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Permanent type battery connections were installed..
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2016
Resolved
Make repairs to the delamination found in the uppermost corner of the forward bulkhead in the aft steering gear compartment.
Action required: 705 - Other - as specified
Resolved 25 November 2016
Resolution: permanent repairs made to delamination, back to good material.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016
Resolved
Forward deck railing located forward of the wheel house is missing a tack weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Forward deck railing tack welded.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016
Resolved
Ring buoy is missing retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Vessel operator provided retro reflective tape.