MIZNER'S DREAM

MIZNER'S DREAM is a 1980 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2026, along with 15 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 14 May 2026.

Built
1980
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM8069
Flag
UNITED STATES
Maury page id
psix-52465

Documentation record

Registered dimensions (L × B × D)41.5 ft × 13.8 ft × 6.8 ft
Registered tonnagegross 23 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST AUGUSTINE BOAT WORKS · ST AUGUSTINE, FL, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

14 May 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8372843
12 May 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8132958
18 September 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004699
17 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7896741
28 February 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644534
20 October 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7581072
22 February 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7399854
24 March 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7163225
11 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7057793
14 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6938989
1 April 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6653465
12 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559813
4 April 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6383905
29 March 2017 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6113872
12 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6020692
17 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5879254

Deficiency record · 15

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 May 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Electronic and paper charts have not been updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: new electronic chart installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel has not completed and logged monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: log created.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 May 2025 Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant [name withheld] were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: hatches properly labled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 February 2023 Resolved
Observed sagging deck on port and starboard main deck in way of port and starboard doors on forward side of the vessel near the operating station. Make proper repairs to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2023
Resolution: cropped and renewed FRP/plywood deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 March 2021 Resolved
Water intrusion from port aft deck into lazz. Repair caulking from deck above lazz. port side 46CFR176.802(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2021
Resolution: Vessel provided repair pictures addressing the correction of the deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 April 2019 Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. Mutiple first aid kit items are expired. - 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Provided proof of new first aid kit.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 4 April 2018 Resolved
Lable Storage as "Distress Signals"
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Storage box labled properly as Distress Signals.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018 Resolved
Bilge pump wiring located below bilge pump float switch.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Bilge pump wiring relocated above bilge pump float switch.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 April 2018 Resolved
Child lifejackets stored with adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Child lifejackets provided with separate storage from adult lifejackets.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 April 2018 Resolved
Inspectors unable to verify company is conducting DAPI for employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 12 April 2018
Resolution: Inspectors verified company is conducting DAPI for all employees.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2018 Resolved
Replace battery cable (exposed wiring).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Vessel provided acceptable objective evidence that battery cables were properly insulated at terminal connection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 April 2018 Resolved
Battery connections were not of permanent type.
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Permanent type battery connections were installed..
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2016 Resolved
Make repairs to the delamination found in the uppermost corner of the forward bulkhead in the aft steering gear compartment.
Action required: 705 - Other - as specified
Resolved 25 November 2016
Resolution: permanent repairs made to delamination, back to good material.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016 Resolved
Forward deck railing located forward of the wheel house is missing a tack weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Forward deck railing tack welded.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016 Resolved
Ring buoy is missing retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Vessel operator provided retro reflective tape.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.