MAURY USCG vessel records Sign in
← All vessels

MIZNER'S DREAM

MIZNER'S DREAM is a 1980 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1984, most recently in May 2026, along with 79 deficiencies and 1 operational control.

Records from 1984 to 2026. Most recent: inspection, 14 May 2026.

Built
1980
Last inspected
14 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM8069
Flag
UNITED STATES
367560660
Maury page id
psix-52465

Inspections, by type

…with no type recorded7
Years with a record 38 calendar years (1984–2026)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.5 ft × 13.8 ft × 6.8 ft
Registered tonnagegross 23 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST AUGUSTINE BOAT WORKS · ST AUGUSTINE, FL, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI BEACH, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM8069MMSI 367560660 · active · compulsorily equipped · granted 16 February 2022, expires 16 February 2032 · licensed under a name not among this hull’s recorded names (not shown)
WDG6789MMSI 367560660 · cancelled · compulsorily equipped · granted 26 January 2013, cancelled 9 February 2022
WCX9350MMSI 367324440 · expired · voluntarily equipped · granted 27 November 2007, cancelled 31 March 2018
WDC2534MMSI 366994420 · expired · voluntarily equipped · granted 30 November 2004, cancelled 31 January 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

14 May 2026 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8372843
12 May 2025 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8132958
18 September 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8004699
17 April 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7896741
28 February 2023 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7644534
20 October 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7581072
22 February 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7399854
24 March 2021 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7163225
11 September 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7057793
14 April 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6938989
1 April 2019 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6653465
12 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6559813
4 April 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6383905
29 March 2017 DAPI Audit · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6113872
12 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6020692
17 May 2016 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5879254
3 October 2014 DAPI Audit · Annual Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4998454
15 May 2012 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4313703
21 July 2009 DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3540594
26 June 2008 Hull Examination · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3247354
22 April 2008 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3189769
14 May 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2929890
2 May 2007 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2918895
9 February 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2869608
25 October 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2807769
8 August 2006 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2739050
8 May 2006 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2641418
10 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2541584
13 July 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2425074
15 June 2005 Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2392169
9 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2376066
21 October 2004 Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2228517
14 October 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2223716
29 June 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2114721
17 May 2004 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2071887
8 May 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1789109
12 June 2002 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1629638
8 May 2002 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1614511
9 May 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1063347
26 April 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1382215
24 May 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397436
11 May 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1429344
1 October 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350695
4 May 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1442823
20 July 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1130330
5 June 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 792740
6 June 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110307
14 June 1996 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1191521
20 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385857
15 June 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188181
5 July 1994 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174827
10 September 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1145736
11 August 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1157314
15 September 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938510
2 August 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 998928
5 July 1991 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1248718
25 July 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 918116
21 July 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 930788
12 September 1989 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 892997
23 August 1989 Deficiency Check · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1204751
12 July 1989 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196170
24 October 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 887685
21 July 1988 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1339488
18 November 1986 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1017106
14 November 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1305780
7 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 979774
11 December 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 976321

Deficiency record · 79

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 May 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Electronic and paper charts have not been updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: new electronic chart installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel has not completed and logged monthly inspections.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: log created.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 May 2025 Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”, unless such markings are deemed unnecessary by the cognizant [name withheld] were not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 3 June 2025
Resolution: hatches properly labled.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 28 February 2023 Resolved
Observed sagging deck on port and starboard main deck in way of port and starboard doors on forward side of the vessel near the operating station. Make proper repairs to deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 March 2023
Resolution: cropped and renewed FRP/plywood deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 March 2021 Resolved
Water intrusion from port aft deck into lazz. Repair caulking from deck above lazz. port side 46CFR176.802(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2021
Resolution: Vessel provided repair pictures addressing the correction of the deficiency.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 April 2019 Resolved
A vessel must carry a first-aid kit approved under approval series 160.041. Mutiple first aid kit items are expired. - 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2019
Resolved 16 April 2019
Resolution: Provided proof of new first aid kit.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 4 April 2018 Resolved
Lable Storage as "Distress Signals"
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Storage box labled properly as Distress Signals.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2018 Resolved
Bilge pump wiring located below bilge pump float switch.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Bilge pump wiring relocated above bilge pump float switch.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 April 2018 Resolved
Child lifejackets stored with adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Child lifejackets provided with separate storage from adult lifejackets.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 4 April 2018 Resolved
Inspectors unable to verify company is conducting DAPI for employees.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 12 April 2018
Resolution: Inspectors verified company is conducting DAPI for all employees.
Electrical › Electric Supply System (service) › Cable
Issued 4 April 2018 Resolved
Replace battery cable (exposed wiring).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Vessel provided acceptable objective evidence that battery cables were properly insulated at terminal connection.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 April 2018 Resolved
Battery connections were not of permanent type.
Action required: 705 - Other - as specified
Due 11 April 2018
Resolved 13 April 2018
Resolution: Permanent type battery connections were installed..
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 October 2016 Resolved
Make repairs to the delamination found in the uppermost corner of the forward bulkhead in the aft steering gear compartment.
Action required: 705 - Other - as specified
Resolved 25 November 2016
Resolution: permanent repairs made to delamination, back to good material.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 May 2016 Resolved
Forward deck railing located forward of the wheel house is missing a tack weld.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Forward deck railing tack welded.
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2016 Resolved
Ring buoy is missing retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 26 May 2016
Resolution: Vessel operator provided retro reflective tape.
Communications › Radio Communications › EPIRB
Issued 3 October 2014 Resolved
EPIRB installation location does not allow for a float free arrangement. Relocate EPIRB so that is unobstructed.
Action required: 705 - Other - as specified
Due 23 October 2014
Resolved 23 October 2014
Resolution: EPIRB moved to forward port side of house.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 3 October 2014 Resolved
Assign Designated Employee Representative in accordance with DAPI program.
Action required: 705 - Other - as specified
Due 23 October 2014
Resolved 23 October 2014
Resolution: New DER asssigned.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 October 2014 Resolved
Vessel must complete their dry dock and annual inspection, both overdue.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2014
Resolution: Dry Dock/ISE and Annual Inspection were completed. Lapse occurred due transition of internal management from death of prior manager who coordinated all interaction with the USCG.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2012 Resolved
Exterior hull: make proper repairs to port exhaust tube fiberglass, starboard corner where transom and side shell intersect IWO boot strip and re-seal STBD transom through hull.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 August 2012
Resolved 18 April 2018
Resolution: Corrected to the satisfaction of the attending marine inspector.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 15 May 2012 Resolved
Provide report showing strut bearings are still in tolerance with MFG. recommendations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Superstructure
Issued 15 May 2012 Resolved
Remove wood pieces under gunnels port side, Aft IWO cleat and STBD wood pieces IWO cleat running longitudinally and make available for USCG inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Transverse Frame
Issued 15 May 2012 Resolved
Make proper repairs, after removing rot, to port engine room transverse frame/spreader between engine longitudinal mounts FWD of port engine. (Engine leak containment fwd BHD).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 May 2012 Resolved
Crop to good wood FWD engine room bulkhead port and starboard outboard upper corners and renew/repair as original. (BHD between #2 compartment and Eng. Room)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2012 Resolved
Forepeak: Crop to good wood deck/floor and hatch box in compartment and make proper repairs as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2012 Resolved
Forepeak: Crop to good wood STBD longitudinal under deck beam and repair/replace as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 September 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Deck Plating
Issued 15 May 2012 Resolved
Forepeak: Remove all rotten wood under deck and make repairs as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 May 2012 Resolved
Forepeak: Crop to good wood STBD BHD between forepeak and #2 compartment and make repairs as original.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 September 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Superstructure
Issued 15 May 2012 Resolved
Main deck salon, remove both port and STBD interior BHDs and fwd BHDs, make available for USCG inspection. Water intrusion through all BHDs listed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 May 2012 Resolved
Provide proposal to arrest water intrusion both port and STBD side longitudinal bulkhead caps exterior just under house. Water is entering salon through cracks in caps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 15 May 2012 Resolved
Crop and renew rotten wood as identified in item #11.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 15 May 2012 Resolved
A) Make areas identified to have water intrusion available for USCG inspection. B) Provide repair proposal for all repairs. Repairs are to be made IAW approved structural plans, as original and to approved specifications. C) All FRP repairs to be made with fire retardant resin.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 July 2012
Resolution: Corrected to the satisfaction of the attending marine inspector.
Navigation › Piloting/Steering › Marine Charts
Issued 21 July 2009 Resolved
Prior to the carriage of passengers provide onboard updated/current edition of US Coast Pilot, USCG Light List, Tidal Currents, Tide Tables and Charts for operating area.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2010
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 July 2009 Resolved
Prior to the carriage of passengers and to the satisfaction of the attending USCG Marine Inspector, show crew is competent in Man overboard and Fire drills while U/W.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2010
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 July 2009 Resolved
Replace floating water light that is attached to ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2010
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 July 2009 Resolved
Provide one additional Adult Type 1 lifejacket onboard for a total of 42 prior to carrying 42 passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2010
Engineering › Bilge Water Management System › Valve
Issued 21 July 2009 Resolved
Make repairs to fwd void port electric submersible pump overboard discharge hose @ valve (currently there is a leak at hose/valve connection).
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 15 June 2010
Construction/Loadline › Hull › Hull Plating
Issued 25 June 2008 Resolved
Make proper repair to hull IWO transducer STBD side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Construction/Loadline › Hull › Stiffener
Issued 25 June 2008 Resolved
Make proper repair (crop and renew as original) wasted clamp on STBD side aft engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Stability › Watertight Integrity › General
Issued 25 June 2008 Resolved
Rig STBD deck drain (interior drain) leading into Engine room so that it does not drain into bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Stability › Watertight Integrity › General
Issued 25 June 2008 Resolved
Ensure no water intrusion is still present on port side main deck that was leaking into engine room IWO port F/O tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 June 2008 Resolved
Make proper repair to aft deck beam in 2nd void/compartment (just fwd of transverse bulkhead).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 June 2008 Resolved
Seal around FWD lazzerette hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2008
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 April 2008 Resolved
Replace expired items in first aid kit (eye wash solution, aspirin and ammonia inhalants).
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 21 July 2009
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 April 2008 Resolved
Provide current navigation publications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 21 July 2009
Resolution: Issued as a Prior to carrying passenger CG-835 at 2009 Annual Exam.
Personnel › Training › Familiarization Training
Issued 22 April 2008 Resolved
Provide crew and demonstrate emergency drills.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 April 2008
Resolved 21 July 2009
Resolution: Issued this as a CG-835, prior to carriage of passengers, at 2009 Annual Exam
Documentation › Certificates/Documents › FCC SSL
Issued 30 April 2007 Resolved
Vsl rep to provide vaild radio safety certificate.
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 June 2007
Resolved 14 May 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 8 August 2006 Resolved
Provide documentation to show evidence of drug testing background checks.
Due 15 August 2006
Resolved 25 October 2006
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 8 August 2006 Resolved
Provide documentation of EAP training for crew.
Due 15 August 2006
Resolved 25 October 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 August 2006 Resolved
Provide missing items from first aid kit.
Due 15 August 2006
Resolved 25 October 2006
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 8 August 2006 Resolved
Provide 26 adult life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2006
Resolved 25 October 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 8 August 2006 Resolved
Provide A-II extinguisher in accommodation space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2006
Resolved 25 October 2006
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 8 August 2006 Resolved
Remove fuel oil fill hose from center tank when tank is emptied. Complete prior to COI exam in May 2007.
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 9 February 2007
Construction/Loadline › Hull › Side Shell
Issued 8 May 2006 Resolved
Sand and resin 2 spots on port side shell amidships.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 June 2006
Engineering › Fuel Oil Service System › Piping
Issued 8 May 2006 Resolved
Provide grounding straps for fuel fills.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 30 June 2006
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 8 May 2006 Resolved
Remove plastic vent ducts in forward void and engineroom. Replace with metal.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 30 June 2006
Construction/Loadline › Structures › End Bulkhead
Issued 8 May 2006 Resolved
Provide written proposal and make permanent repairs to aft framing and overhead in steering void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 June 2006
Engineering › Steering Gear System › Rudder
Issued 8 May 2006 Resolved
Provide rudder stops.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 30 June 2006
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 8 May 2006 Resolved
Replace cutlass bearings.
Action required: 705 - Other - as specified
Resolved 30 June 2006
Documentation › Certificates/Documents › FCC SSL
Issued 16 June 2005 Resolved
Provide FCC Radio Telephone Safety Certificate
Condition: Placed in Improper Service
Due 15 July 2005
Resolved 12 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2005 Resolved
Replace expired items in first aid kit.
Condition: Improper/Lack of Maintenance
Due 15 July 2005
Resolved 22 June 2005
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 16 June 2005 Resolved
Provide compass deviation table.
Condition: Placed in Improper Service
Due 15 July 2005
Resolved 8 July 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 June 2005 Resolved
Provide seperation of adult and children life jackets.
Condition: Placed in Improper Service
Due 15 July 2005
Resolved 10 July 2005
Engineering › Fuel Oil Service System › Filter
Issued 16 June 2005 Resolved
Remove plastic petcocks from Raycor fuel oil filters.
Condition: Placed in Improper Service
Due 15 July 2005
Resolved 17 June 2005
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 June 2005 Resolved
Replace throw line for life ring.
Condition: Improper/Lack of Maintenance
Due 15 July 2005
Resolved 22 June 2005
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2003 Resolved
Provide additional coarsings or fill in space between top rail LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Due 15 August 2003
Resolved 19 November 2003
Construction/Loadline
Issued 26 April 2001 Resolved
Seal holes on collision bulkhead and Aft Engine room bulkhead.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
Provide donning placard for jacket type PFD's.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Construction/Loadline
Issued 26 April 2001 Resolved
Provide visual indicator at operating station for Fwd. Bilge pump.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 4 May 1999 Resolved
Prior to 01Jun99, provide (3) red and (3) orange distress signals
Condition: Unknown
Due 5 June 1999
Resolved 5 June 1999
Lifesaving
Issued 4 May 1999 Resolved
Prior to 01Jun99, provide waterproof visual distress signal box
Condition: Unknown
Due 5 June 1999
Resolved 5 June 1999
Construction/Loadline
Issued 4 May 1999 Resolved
Prior to 15Jun99, provide evenly coursed railing at aft deck with spacings not to exceed 12"
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 4 May 1999 Resolved
Prior to carrying passengers, repair/replace mast and running lights
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 4 May 1999 Resolved
Prior to 15Jun99, repair cracked weld at base of aft port embarkation rail stanchion._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 20 July 1998 Resolved
PRIOR TO OPERATING AFTER DUSK, PROVIDE PROPER NAV. LIGHT BULB IN ALL NAV. LIGHT FIXTURES.
Condition: Unknown
Due 27 July 1998
Resolved 11 August 1998
Construction/Loadline
Issued 23 August 1989 Resolved
REPLACE PORT SIDE DECH HATCH CARLINE.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Engineering
Issued 23 August 1989 Resolved
INSTALL NEW ENGINES AND CO0NDUCT SEA TRIAL
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Construction/Loadline
Issued 23 August 1989 Resolved
REPLACEMENT OF BOTH SEAVALVES REQUIRED.
Condition: Unknown
Due 23 August 1989
Resolved 23 August 1989
Engineering
Issued 12 July 1989 Resolved
REPLACE FLEXIBLE FUEL LINES, BOTH SUPPLY AND RETURN, WITH COPPER, COPPER NICKEL, NICKEL COPPER HARD LINE OF AT LEAST 0.035 INCH WALL THICKNESS.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989
Fire Fighting
Issued 12 July 1989 Resolved
RENEW OR REPAIR MOUNTING BRACKET ON FIRE EXTINGUISHER IN ENGINE ROOM.
Condition: Unknown
Due 12 July 1989
Resolved 12 July 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.