MAURY USCG vessel records Sign in
← All vessels

PIRATES PARADISE

PIRATES PARADISE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1985, most recently in January 2026, along with 134 deficiencies — 1 with no resolution recorded — and 4 operational controls.

Records from 1985 to 2026. Most recent: inspection, 29 January 2026.

Built
1981
Last inspected
29 January 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE7766
Flag
UNITED STATES
367745710
Maury page id
psix-52486

Inspections, by type

…with no type recorded8
…past their stated due date1
Years with a record 37 calendar years (1985–2026)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
16 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDJ5362MMSI 367745710 · active · voluntarily equipped · granted 6 May 2017, expires 6 May 2027
WDI9145MMSI 367745710 · cancelled · compulsorily equipped · granted 15 July 2016, cancelled 4 May 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDE7766MMSI 367397360 · expired · compulsorily equipped · granted 28 February 2009, cancelled 4 May 2019 · licensed under a name not among this hull’s recorded names (not shown)
WCY9632MMSI not assigned · expired · compulsorily equipped · granted 2 April 1999, cancelled 6 June 2009 · licensed under a name not among this hull’s recorded names (not shown)
WCF8479MMSI not assigned · expired · voluntarily equipped · granted 13 May 1994, cancelled 18 July 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 67

29 January 2026 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8308473
25 November 2024 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8085495
26 August 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7990542
2 November 2023 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7819171
26 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7798881
3 November 2022 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7588777
27 July 2022 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7517678
4 August 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7277117
24 November 2020 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7096418
21 August 2020 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7038923
29 October 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6844311
6 November 2018 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6575272
6 November 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6575280
10 August 2018 Construction Oversight · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6506946
13 June 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6174395
3 August 2016 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5960700
19 July 2012 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4383484
27 January 2012 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 4234870
13 July 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4079817
29 November 2010 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3900092
16 April 2009 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3451770
25 March 2009 Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3438562
2 March 2009 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3426560
27 February 2007 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2878460
20 February 2007 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2874353
30 May 2006 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2663980
15 June 2005 Deficiency Check · Annual Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 2391747
10 May 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2353921
29 October 2004 Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2230881
18 May 2004 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2070929
5 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1786721
20 November 2002 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1708808
25 June 2002 Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1635997
23 April 2002 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1608307
7 June 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1415618
31 July 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 821224
12 May 2000 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1376183
9 May 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445622
2 June 1999 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 1508739
12 May 1999 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 798009
12 April 1999 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1426208
14 May 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125972
14 May 1998 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1128573
20 April 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1123432
3 November 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 70332
3 November 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 229348
26 September 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 776761
4 September 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1121847
9 May 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086046
24 April 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1086259
17 April 1995 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 882603
11 July 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864794
22 April 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 856933
22 April 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160958
19 May 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1132309
22 April 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 825914
28 April 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943680
23 October 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251628
23 April 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 912750
23 April 1991 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 939269
17 April 1990 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 902917
18 April 1989 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340684
12 April 1988 Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 995865
16 April 1987 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1022246
22 April 1986 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307851
29 May 1985 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 985688
28 May 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 979903

Deficiency record · 134

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2026 No resolution recorded
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means. A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant OCMI. Vessel hand tiller not on board. Provide hand tiller and demonstrate operation to CG marine inspectors. 46 CFR 182.620(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2026 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 January 2026 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. EPIRB HRU expired. Owner replaced EPIRB HRU with new unit. 46 CFR 185.740(b)
Action required: 10 - Deficiency Rectified
Resolved 29 January 2026
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 November 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Fireboy system will not shutdown ME. Provide repair tech report/invoice and demonstrate proper operation for USCG marine inspectors. 46 CFR 181.420(a)(3)
Action required: 705 - Other - as specified
Due 2 November 2023
Resolved 13 November 2023
Resolution: Observed satisfactory testing of fireboy engine shutdown and override.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2023 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI. 01 portable fire extinguisher missing annual maintenance. Provide serviceable fire extinguisher. 46 CFR 181.500
Action required: 705 - Other - as specified
Due 2 November 2023
Resolved 13 November 2023
Resolution: Verified operator had 01 portable extinguisher serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 November 2023 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel missing all 3 fire buckets. Provide replacements. 46 CFR 181.610
Action required: 705 - Other - as specified
Due 2 November 2023
Resolved 13 November 2023
Resolution: Verified 03 fire buckets on board, stenciled, and lanyards in place.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 1 December 2022 Resolved
EPIRB battery is expired. Install a current battery or replace EPIRB. Route restricted to no more than 3 miles from shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 10 December 2022
Resolution: Battery replaced by service company.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 December 2022 Resolved
Stern navigation light is inoperable. Make repairs or replace light prior to operating at night. 46 CFR 183.420
Action required: 705 - Other - as specified
Resolved 11 January 2023
Resolution: Bulb replaced and operates SAT.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 December 2022 Resolved
Emergency instructions not provided. Provide and post emergency instructions. 46 CFR 185.512
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 11 January 2023
Resolution: Instructions posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 December 2022 Resolved
Life ring waterlight clip is seized and lanyard is not 3'-6' in length. Repair or replace clip and extend lanyard to approved length. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 18 January 2023
Resolution: Clip replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 December 2022 Resolved
Aspirin in the first aid kit is expired. Provide current aspirin. 46 CFR 160.041
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 December 2022
Resolved 18 January 2023
Resolution: Non-expired aspirin provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 November 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Annual inspection not completed withing the allowable time frame. 46 CFR 176.500(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2022
Resolution: Conducted annual inspection.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 August 2021 Resolved
Pre-engineered fixed gas extinguishing system for the machinery space did not shut down propulsion engine when tested. Report from service company does not state what was serviced or tested. Provide proof of proper operation of extinguishing system prior to carrying passengers. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2021
Resolution: Satisfactory system report received from service company.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 August 2021 Resolved
40-B:C portable fire extinguisher is not charged and is in non-serviceable condition. Replace extinguisher with an approved type 40-B:C prior to carrying passengers. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2021
Resolution: Extinguisher replaced in kind.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 August 2021 Resolved
Lazerette bilge high level alarm is inoperable. Prove proper operation of the audible and visual alarms prior to carrying passengers. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2021
Resolution: Alarms operate SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 August 2021 Resolved
Automatic electrical submersible bilge pumps visual alarms are inoperable. Prove proper operation of automatic bilge pump alarms. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 30 August 2021
Resolution: Alarms operate SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 18 August 2021 Resolved
Life float float light inoperable. Provide proof of proper operation of float light prior to operating after sunset. 46 CFR 180.175(d)
Action required: 705 - Other - as specified
Resolved 31 August 2021
Resolution: Float light operates SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 August 2021 Resolved
Life jacket donning placard is posted in a location not readily visible to passengers. Move placard outside of V-berth. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 30 August 2021
Resolution: Placard moved to main deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 August 2021 Resolved
Life jacket stowage location labeling is in a location no visible to passengers. Label stowage location outside of V-berth. 46 CFR 180.78
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 30 August 2021
Resolution: Location labeled at main deck and in v-berth.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 August 2021 Resolved
Numerous breakers on breaker panel not labeled. Label all breakers. 46 CFR 183.330
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 30 August 2021
Resolution: Breakers labeled SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 August 2021 Resolved
Adult and child life jackets not separated. Adult and child life jackets to be separated. 46 CFR 180.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2021
Resolved 30 August 2021
Resolution: Life jackets separated SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 November 2020 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. The alcohol test strips were found expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: The alcohol test strips were replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 24 November 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Replace expired items in the first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 November 2020
Resolution: The expired items in the first aid kit were replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2020 Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. Install battery box covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 25 November 2020
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 October 2020 Resolved
Port and Stbd rails found to be loose at mounts. Tighten mounts to ensure rails are safely secured to vessel prior to credit dry-dock. 46 CFR 177.900
Action required: 705 - Other - as specified
Resolved 24 November 2020
Resolution: Port and Stbd hand rails were repaired to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2020 Resolved
Make repairs to blisters in the hull to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 28 October 2020
Resolution: Repairs made SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2020 Resolved
Large section of de-lamination found IWO fwd, port side hull. Make repairs to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 28 October 2020
Resolution: Repairs made SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 November 2019 Resolved
Apply new retro-reflective tape on life ring and add new tape to life float. 46 CFR 180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2019
Resolved 25 November 2019
Resolution: Tape applied.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 November 2019 Resolved
COD not onboard. Provide proof of vessel documentation prior to operations. 46 CFR 67.7
Action required: 60 - Rectify deficiencies prior to movement
Due 22 November 2019
Resolved 22 November 2019
Resolution: Proof of vessel's COD provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 November 2019 Resolved
Vessel passed allowable time to complete annual inspection. Must complete annual inspection prior to carrying passengers. 46 CFR 176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 November 2019
Resolution: Completed annual inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 November 2018 Resolved
Engine room visual high level alarm not visible continuously. Repair alarm. 46 CFR 182.530(a)
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 21 November 2018
Resolution: High level alarm SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 November 2018 Resolved
Lazerette automatic bilge pump alarm inoperative. Repair alarm. 46 CFR 182.530(c)
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 21 November 2018
Resolution: Alarm SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 November 2018 Resolved
Replace wasted life ring grab line or replace life ring. 46 CFR 180.70
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 21 November 2018
Resolution: Life ring replaced.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 November 2018 Resolved
Provide current EPIRB log. 46 CFR 185.728
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 21 November 2018
Resolution: Log provided SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 9 November 2018 Resolved
Install rail course or equivalent between rails forward of swim platform. 46 CFR 177.900(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2018
Resolved 21 November 2018
Resolution: Chain course installed in lieu of rail course.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 November 2018 Resolved
Re-label fuel shut off valves. 46 CFR 185.608
Action required: 705 - Other - as specified
Due 16 November 2018
Resolved 21 November 2018
Resolution: Labeled SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 28 September 2018 Resolved
Make rails on upper deck proper height with courses of 12" 46 CFR 177.900
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 October 2018
Resolved 9 November 2018
Resolution: Rails and courses installed.
Lifesaving › Hand Flares › Quantity
Issued 13 June 2017 Resolved
Provide 2 additional flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2017
Resolution: Provided 2 new approved flares while I was there.
Navigation › Piloting/Steering › Marine Charts
Issued 13 June 2017 Resolved
Provide marine chart for operating area.
Due 13 June 2017
Resolved 13 June 2017
Resolution: Provide marine chart.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 July 2012 Resolved
Fixed engine room extinguisher manufactured by sea-fire does not match control system manufactured by fire-boy. Provide approved pre-engineered fire extinguishing system for engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2012
Stability › Watertight Integrity › General
Issued 19 July 2012 Resolved
Provide cap for unused through-hull valve in starboard side engine room.
Action required: 705 - Other - as specified
Resolved 23 August 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 July 2012 Resolved
Remove dead-ended wire in engine room.
Action required: 705 - Other - as specified
Resolved 23 August 2012
Lifesaving › Lifebuoys › Serviceable
Issued 13 July 2011 Resolved
Replace or remove wasted ring bouy. Ring bouy is in excess of required amount
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 July 2011 Resolved
Provide retro-reflective material to life ring bouy.
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Hand Flares › Quantity
Issued 13 July 2011 Resolved
Replace missing flares for a total of 6 red and 6 orange.
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 July 2011 Resolved
Provide 18 inch lanyard to water light and attach around body of life float.
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Lifefloat › Paddle
Issued 13 July 2011 Resolved
Label life float paddles with name of vessel.
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 July 2011 Resolved
Replace oxidized lense on life float water light.
Due 3 August 2011
Resolved 2 August 2011
Lifesaving › Lifefloat › Pendant
Issued 13 July 2011 Resolved
Replace wasted life float pendants.
Due 3 August 2011
Resolved 2 August 2011
Engineering › Bilge Water Management System › Pump
Issued 13 July 2011 Resolved
Prove proper operation of secondary fixed bilge pump.
Due 10 August 2011
Resolved 10 August 2011
Engineering › Bilge Water Management System › Valve
Issued 13 July 2011 Resolved
Prove proper operation of bilge discharge gate valve.
Due 10 August 2011
Resolved 10 August 2011
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2010 Resolved
Replace expired items in first aid kit.
Due 8 December 2010
Resolved 9 December 2010
Navigation › Piloting/Steering › Marine Charts
Issued 29 November 2010 Resolved
Provide updated charts for operating area.
Due 8 December 2010
Resolved 9 December 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 November 2010 Resolved
Prove proper operation of anchor light.
Due 9 December 2010
Resolved 9 December 2010
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 29 November 2010 Resolved
Provide proof of EAP training and post hotline phone number.
Due 8 December 2010
Resolved 9 December 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 November 2010 Resolved
Provide MIS report for proof of enrollment.
Due 8 December 2010
Resolved 9 December 2010
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 November 2010 Resolved
Provide certificate of enrollment for current year.
Due 8 December 2010
Resolved 9 December 2010
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 November 2010 Resolved
Replace wasted hose clamp for exhaust piping.
Due 8 December 2010
Resolved 9 December 2010
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 April 2009 Resolved
Provide proper railing on transom of vsl IAW 46 CFR 177.900
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Fire Fighting › Ventilation Systems › Operating Controls
Issued 16 April 2009 Resolved
Provide proper engine room vent closures which are readily available and mounted in the vicinity of the vents IAW 46 CFR 182.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Documentation › Certificates/Documents › FCC SSL
Issued 16 April 2009 Resolved
Provide valid FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 13 May 2009
Communications › Alarms/Indicators › High Water Alarm
Issued 16 April 2009 Resolved
Provide audible alarm at operating station for bilge high level alarm IAW 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 16 April 2009 Resolved
Properly post lifejacket donning placard in conspicuous place visible to crew and passengers IAW 46 CFR 185.516
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 May 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 16 April 2009 Resolved
Provide covers for battery boxes in engine room.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 May 2009
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 16 April 2009 Resolved
Provide current tide and current tables, coast pilot, and CG light list IAW 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Fire Fighting › Fire Bucket › Quantity
Issued 16 April 2009 Resolved
Provide two additional fire buckets IAW 46 CFR 181.610
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 May 2009
Lifesaving › Hand Flares › Quantity
Issued 16 April 2009 Resolved
Provide two additional red distress flares IAW 46 CFR 180.68(b)
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 May 2009
Lifesaving › Lifefloat › Retroreflective Material
Issued 16 April 2009 Resolved
Replace retro reflective tape on life float and life rings.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 May 2009
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 April 2009 Resolved
Provide installation/servicing report for fixed fire fighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Communications › Radio Communications › EPIRB
Issued 16 April 2009 Resolved
Properly mark expiration date on hydrostatic release for EPIRB.
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 13 May 2009
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 16 April 2009 Resolved
Provide proof that company's chemical testing program is IAW 46 CFR 16.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2009
Resolved 18 June 2009
Engineering › Fuel Oil Service System › Piping
Issued 25 March 2009 Resolved
Make port and starboard fuel fills available for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Stability › Watertight Integrity › General
Issued 25 March 2009 Resolved
Replace all thru hull fittings and prove proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Construction/Loadline › Hull › Bottom Plating
Issued 25 March 2009 Resolved
Make proper repairs to area identified on hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Engineering › Fuel Oil Service System › Piping
Issued 25 March 2009 Resolved
Provide grounding for port and starboard fuel fills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 25 March 2009 Resolved
Provide covers for battery boxes.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 March 2009 Resolved
Fill hole in forward bulkhead of engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Fire Fighting › Remote Fuel Shutoff › General
Issued 25 March 2009 Resolved
Provide and label remote fuel shutoffs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 March 2009 Resolved
Double clamp all exhaust piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 25 March 2009 Resolved
Properly secure and repair or replace lagging on engine exhaust.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Engineering › Shafting/Propeller Arrangements › Strut
Issued 25 March 2009 Resolved
Properly repair wasted welds on strut.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 25 March 2009 Resolved
Properly label MSD tank with 3/4 full level.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2009
Construction/Loadline › Hull › Bottom Plating
Issued 27 February 2007 Resolved
Grind to good material all areas indicated on hull and call for approval.
Condition: Damaged By Earlier Event
Due 13 March 2007
Resolved 13 March 2007
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 27 February 2007 Resolved
renew aft cutlass bearing.
Condition: Unknown
Due 13 March 2007
Resolved 13 March 2007
Construction/Loadline › Hull › Bracket
Issued 27 February 2007 Resolved
properly repair cracks on dive platform.
Condition: Improper/Lack of Maintenance
Due 13 March 2007
Resolved 13 March 2007
Engineering › Diesel Engine (propulsion-direct drive) › Piping (air intake)
Issued 30 May 2006 Resolved
Required ventilation for engine room not installed. vent duct area must be one square inch per foot of beam on vessel. Owner must provide proper ventilation by first submitting drawing for approval.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 23 March 2007
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 30 May 2006 Resolved
emergency steering tiller must be re-tooled to fit over the rudder post.
Due 30 May 2006
Resolved 20 February 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 30 May 2006 Resolved
install new fuel supply hose to engine, meeting SAE J 1942 reqirements
Condition: Improper/Lack of Maintenance
Due 14 June 2006
Resolved 20 February 2007
Stability › Weathertight Integrity › General
Issued 30 May 2006 Resolved
Engine room hatch must be made weather tight, with approved drawing provided
Due 15 July 2006
Resolved 23 March 2007
Fire Fighting › Structural - B Class Divisions › Machinery Spaces
Issued 30 May 2006 Resolved
must provide non-combustible fire protection for the engine room hatch and overhead. Must submit drawing for fire protection requirements
Condition: Placed in Improper Service
Due 15 July 2006
Resolved 23 March 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 15 June 2005 Resolved
The life float painter is worn and needs replacement. One life float paddle is cracked. Replace life float paddle and painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 16 June 2005
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 15 June 2005 Resolved
Vessel did not have adequate log aboard. Provide log of EPIRB tests, lifesaving equipment checks and drills.
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 16 June 2005
Documentation › Certificates/Documents › Stability Letter
Issued 15 June 2005 Resolved
Provide updated stability letter with current vessel name. 46CFR176.306
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 15 July 2005
Documentation › Manifests/Lists › Emergency Checkoff List
Issued 15 June 2005 Resolved
The vessel did not have an emergency instruction list on board. Provide emergency instructions list and post. 46CFR185.510
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 16 June 2005
Communications › Internal Communications System › Portable Radios
Issued 15 June 2005 Resolved
Vessel did not have adequate communication from helm to mate on main deck. Provide communication (internal) from bridge to main deck. 46CFR185.510
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 16 June 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 15 June 2005 Resolved
All but one PFD had corroded buckles. Clean, repair, or replace corroded snaps and buckles on PFD's before further operation. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2005
Resolved 16 June 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 15 June 2005 Resolved
Three of the four deck lights are not working and missing the lens. Repair/replace cabin light fixtures before night operation 46CFR183.410
Action required: 705 - Other - as specified
Due 15 July 2005
Resolved 16 June 2005
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 18 May 2004 Resolved
Stop leakage around rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2004
Resolved 19 May 2004
Engineering › Fuel Oil Service System › Valve
Issued 18 May 2004 Resolved
Make emergency fuel shut off valves accessable
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 May 2004
Resolved 19 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 18 May 2004 Resolved
Demonstrate proper operation of fixed fire fighting system in E/R 46CFR181.400
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 19 May 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 May 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 25 May 2004
Resolved 19 May 2004
Documentation › Certificates/Documents › FCC SSL
Issued 18 May 2004 Resolved
Provide FCC Safety Radio certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2004
Resolved 19 May 2004
Documentation › Logs/Records › Logbook (official)
Issued 5 May 2003 Resolved
VESSEL LOGBOOK NOT PROVIDED. DRILLS AND EPRIB CHECKS NOT BEING LOGGED.
Action required: 705 - Other - as specified
Due 26 May 2003
Resolved 19 May 2004
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 25 June 2002 Resolved
CURRENT NAV RULES NOT PROVIDED.
Condition: Unknown
Due 26 June 2002
Resolved 26 June 2002
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 June 2002 Resolved
ALL DRILLS AND MONTHLY EPRIB CHECKS NOT BEING LOGGED.
Condition: Unknown
Due 26 June 2002
Resolved 26 June 2002
Documentation › Markings/Placards
Issued 25 June 2002 Resolved
LIFE JACKET DONNING INSTRUCTIONS AND EMERGENCY BROADCAST PLACARD NOT POSTED. LEGACY COMPONENT DESC: LIFE JACKET DONNING INSTRUCTIONS
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2002
Resolved 25 June 2002
Engineering › Fuel Oil Service System › Filter
Issued 25 June 2002 Resolved
PLUG NOT INSTALLED FUEL OIL FILTER PETCOCK DRAIN.
Condition: Unknown
Due 26 June 2002
Resolved 26 June 2002
Engineering › Steering Gear System › Pin
Issued 25 June 2002 Resolved
STEERING ARM PIN MISSING COTTER PIN.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 25 June 2002
Resolved 25 June 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 23 April 2002 Resolved
Have Fixed Fire Fighting System inspected. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 April 2002
Resolved 23 April 2002
Electrical
Issued 7 June 2001 Resolved
Remove loose wires on fwd bulkhead in engine room.
Condition: Unknown
Due 25 June 2001
Resolved 22 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Provide appropriate flares prior to carrying passengers.
Condition: Unknown
Due 7 June 2001
Resolved 22 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Properly mark adult and child PFD locations.
Condition: Unknown
Due 25 June 2001
Resolved 22 June 2001
Navigation
Issued 7 June 2001 Resolved
Provide current coast pilot, light list, tide and current tables.
Condition: Unknown
Due 25 June 2001
Resolved 22 June 2001
Lifesaving
Issued 7 June 2001 Resolved
Renew weathered sea painter for life float.
Condition: Unknown
Due 25 June 2001
Resolved 22 June 2001
Electrical
Issued 7 June 2001 Resolved
Remove loose/ unused wires to bilge pump in compartment aft of engine room.
Condition: Unknown
Due 25 June 2001
Resolved 22 June 2001
Navigation
Issued 31 July 2000 Resolved
Prove proper operations of navigation lights prior to carrying passengers.
Condition: Unknown
Due 4 August 2000
Resolved 7 August 2000
Documentation
Issued 12 April 1999 Resolved
PROVIDE PROOF OF COMPLIANCE WITH THE USCG DRUG TESTING PPROGRAM.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 12 April 1999 Resolved
REPLACE HANDWHEEL ON MSD INTAKE THROUGH- HULL VAVLE.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
REPAIR OR REPLACE LIFE RING.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Lifesaving
Issued 12 April 1999 Resolved
REPLACE BATTERIES IN WAY OF FLOAT LIGHT.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 12 April 1999 Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM FROM ALL COMPARTS.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 12 April 1999 Resolved
PROVIDE PROOF OF FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Unknown
Issued 12 April 1999 Resolved
REPLACE LEAKING MSD PUMPOUT LINE.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Documentation
Issued 14 May 1998 Resolved
EE
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Accommodation/Occupational Safety
Issued 14 May 1998 Resolved
PROVIDE VENTS FOR SANITATION SYSTEM ABOVE DECK.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Documentation
Issued 4 September 1997 Resolved
PROVIDE A POSITIVE MEANS OF SECURING MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 4 September 1997 Resolved
RENEW BOTH FREEMAN HATCH GASKETS.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 4 September 1997 Resolved
RENEW RETRO-REFLECTIVE TAPE ON LIFE FLOAT.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 4 September 1997 Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM FROM ALL COMPARTMENTS.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 4 September 1997 Resolved
PROVIDE PROPER EXHAUST LAGGING.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 4 September 1997 Resolved
REPLACE HAND WHEELS AS NECESSARY IN WAY OF ALL BILGE ISOLATION VALVES.
Condition: Unknown
Due 4 October 1997
Resolved 20 October 1997
Documentation
Issued 22 April 1994 Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO COAST GUARD MSO MIAMI.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 22 April 1994 Resolved
PROPERLY MARK LIFEJACKET LOCATION.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Engineering
Issued 22 April 1994 Resolved
PROVE THE BLUE HOSE USED IN THE VESSELS ENGINE WET EXHAUST SYSTEM IS CERTIFIED FOR THAT PURPOSE.
Condition: Unknown
Due 22 April 1994
Resolved 22 April 1994
Lifesaving
Issued 22 April 1993 Resolved
repaint & relabel life float
Condition: Unknown
Due 22 April 1993
Resolved 22 April 1993

Ownership record