ADRIENNE CALLAIS is a 1980 offshore supply vessel. The Coast Guard has recorded 50 inspections since 1980, most recently in September 2003, along with 17 deficiencies.

Records from 1980 to 2003. Most recent: inspection, 8 September 2003.

Built
1980
Last inspected
8 September 2003
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRA9909
Flag
UNITED STATES
—
Maury page id
psix-52521

Inspections, by type

…with no type recorded19
Years with a record 23 calendar years (1980–2003)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)104.5 ft × 25.0 ft × 6.8 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderUNIVERSAL IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGOLDEN MEADOW, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationNo Operation - PM · issued 31 December 2001 · expires 31 December 2002
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SCNO 1328-B Tank Barge · MISLE 49838 · 4 November 1999 · activity 48138ROBERT J. EYMARD Towing Vessel · MISLE 89155 · 4 November 1999 · activity 48138MISS HALEY Commercial Fishing Vessel · MISLE 64809 · 31 July 1992 · activity 102799

Inspection history · 50

8 September 2003 Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1899673
4 January 2002 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1435307
2 March 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1453861
1 March 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 57107
1 March 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1453732
21 January 2000 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815176
21 January 2000 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1045852
12 January 2000 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815146
6 January 2000 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815245
1 January 2000 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 815246
1 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1463540
17 December 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 813691
8 December 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 812730
8 December 1999 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 812732
2 December 1999 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 810419
4 November 1999 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 48138
19 October 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794404
25 June 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884537
6 January 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449133
6 July 1998 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 120458
21 November 1997 Damage Survey · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375249
27 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779100
26 August 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456417
8 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1078437
6 April 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428475
6 April 1994 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460702
1 March 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452930
27 October 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665854
31 July 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 102799
31 July 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214403
20 April 1992 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465081
10 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 127972
10 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 220932
19 February 1992 Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1261203
23 July 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665853
17 May 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931084
17 May 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217078
15 February 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901141
21 February 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237615
16 February 1989 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199510
20 January 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1014304
23 January 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009730
20 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294441
17 January 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305538
16 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288284
2 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283636
12 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280166
21 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967092
17 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969163
18 December 1980 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968941

Deficiency record · 17

Lifesaving › Buoyant Apparatus › Capacity
Issued 4 January 2002 Resolved
Life float wasted due to sun damage. LEGACY COMPONENT DESC: Life float
Condition: Unknown
Due 14 February 2002
Resolved 14 November 2006
Operations/Management › Drug and Alcohol Testing › CG Notification (positive results/refusals)
Issued 4 January 2002 Resolved
Could not provide annual drug and alcohol auditing program. LEGACY COMPONENT DESC: Employee Coverage
Condition: Unknown
Due 14 February 2002
Resolved 14 November 2006
Accommodation/Occupational Safety
Issued 1 January 2000 Resolved
Provide three (3) courses of chains or hand rails at port & starboard midbody area gunwales.
Condition: Unknown
Due 1 January 2000
Resolved 1 January 2000
Construction/Loadline
Issued 1 January 2000 Resolved
Free up all closure devices (dogs) on weather tight doors to engine room and passenger area.
Condition: Unknown
Due 1 January 2000
Resolved 1 January 2000
Construction/Loadline
Issued 1 January 2000 Resolved
Provide closing devices for steering gear compartment port side access cover.
Condition: Unknown
Due 1 January 2000
Resolved 1 January 2000
Engineering
Issued 2 December 1999 Resolved
PROVIDE A MEANS FOR SHUTTING DOWN THE PROPULSION ENGINES AT THE MAIN PILOTHOUSE CONTROL STATION AS PER 46 CFR 184.620(B) AND (C).
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Navigation
Issued 2 December 1999 Resolved
PROVE PROPER OPERATION OF THE STEERING RUDDER POST BY REMOVING THE EXCESSIVE PLAY.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 2 December 1999 Resolved
PROVIDE A BILGE HIGH LEVEL ALARM WITH VISUAL AND AUDIBLE INDICATORS IN THE OPERATING STATION FOR THE AFT STEERING COMPARTMENT AS PER 46 CFR 182.530.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Navigation
Issued 17 May 1991 Resolved
PROVIDE PROPER NAVIGATION LIGHTS (WRONG BULBS CURRENTLY IN PLACE).
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Navigation
Issued 17 May 1991 Resolved
PROVE PROPER OPERATION OF FIRE PUMP - 60 P.S.I. OR GREATER TO HYDRANTS ON _x001C_DECK. HOSES AND NOZZLES TO BE TESTED ALSO._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Navigation
Issued 17 May 1991 Resolved
VESSEL IS NOT TO OPERATE UNTIL LIFE FLOATS ARE PROPERLY STOWED._x001C_ (WEAK LINK AND PAINTER CONNECTION, LIFE FLOATS CONNECTED TOGETHER, ETC...)_x001C__x001C_ _x001C_
Condition: Unknown
Due 17 May 1991
Resolved 17 May 1991
Documentation
Issued 15 February 1991 Resolved
PROVIDE PLACARD AND WASTE MANAGEMENT PLAN IAW 33CFR PART 151 SUBPART A.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Deck/Cargo
Issued 15 February 1991 Resolved
INSTALL APPROVED FLAME SCREEN ON #2 PORT FUEL OIL TANK.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Fire Fighting
Issued 15 February 1991 Resolved
REPAIR ELECTRIC MOTOR TO FIRE PUMP COUPLER AND PROVE OPERATION.
Condition: Unknown
Due 15 February 1991
Resolved 15 February 1991
Accommodation/Occupational Safety
Issued 21 February 1990 Resolved
REMOVE EXCESSIVE RUST & CONDUCT HYDROSTATIC TEST ON STBD AIR RECIEVER.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Electrical
Issued 21 February 1990 Resolved
INSTALL SUITABLE BATTERY BOX FOR STBD GENERATOR BATTERY.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Documentation
Issued 16 February 1989 Resolved
MAKE VESSEL AVAILABLE FOR A FEDERAL COMMUNICATIONS COMMISSION (FCC) SAFETY RADIO-TELEPHONE CERTIFICATE INSPECTION IN ACCORDANCE WITH 46 CFR 184.25-1(A). ATTACH AN UNCERTIFIED COPY OF THE FCC CERTIFICATE TO THE LETTER REQUESTED ABOVE.
Condition: Unknown
Due 16 February 1989
Resolved 16 February 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.