Records from 1985 to 2026. Most recent: inspection, 9 June 2026.
Documentation record
Registered dimensions (L × B × D)32.3 ft × 10.0 ft × 3.2 ft
Registered tonnagegross 6 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAYNE & FRANKLIN, INC. · NORTH KINGSTON, RI, UNITED STATES · built 1981
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it6 - Regulatory (Subpart C or D), Gross Ton
6 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
9 June 2026
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8368595
5 June 2024
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887046
24 April 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7887042
28 March 2024
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7886420
12 May 2022
Deficiency Check · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7419731
18 August 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7036168
13 June 2019
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6712114
6 May 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6677666
19 June 2018
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6448240
13 June 2017
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6173921
15 June 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5907280
18 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4892897
12 June 2012
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4340743
3 May 2012
Simplified Stability Test · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4305688
12 December 2011
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206651
14 April 2009
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3452356
10 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232797
13 June 2007
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2960194
14 June 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2679376
15 June 2005
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2391134
16 June 2004
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2097996
26 April 2004
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2048094
11 June 2003
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1814102
1 May 2002
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1611154
9 April 2002
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1602818
6 June 2001
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1362271
21 June 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1395484
25 May 1999
COI Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 804674
10 June 1998
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1126185
4 June 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1109661
12 June 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1189161
7 June 1995
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 876158
8 June 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1019118
16 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 859376
17 June 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 826114
10 June 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1134175
9 June 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 945199
11 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1228324
31 May 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 924731
13 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1036227
13 September 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1195284
22 May 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042456
17 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1349758
30 April 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1018998
16 May 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 995814
21 May 1985
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 989663
15 March 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 980937
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 June 2026
No resolution recorded
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in § 176.500(b)(1) and your Certificate of Inspection must be endorsed. Vessel did not conduct an annual inspection within the allowed timeframe so COI is now invalid. Complete a COI inspection prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 02 fire buckets and their associated lanyards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2024
Resolved 13 June 2024
Resolution: Vessel representative emailed picture of 03 fire buckets for vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 March 2024
Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel missed its annual inspection. Vessel must undergo an inspection for certification prior to operations.
46 CFR 176.500(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2024
Resolution: Conducted satisfactory COI.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 12 May 2022
Resolved
Submersible electric bilge pump shall have a positive control valve installed at the hull penetration. The vessel's two bilge pump discharges have a check valve installed. Install a positive control valve for both lines, at the hull penetration.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 29 June 2022
Resolution: Special consideration granted to use check valve instead of positive control valve.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 12 May 2022
Resolved
A vessel must be provided with bilge pumps. The aft pump did not operate in automatic mode. Ensure pump are operable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 21 June 2022
Resolution: Observed the correct operation of the pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 June 2019
Resolved
A submersible electric bilge pump may be used provided a positive shutoff valve is installed at the hull penetration. No valve is installed at the hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 July 2019
Resolved 25 June 2019
Resolution: Valve was installed at thru hull.
Engineering › Bilge Water Management System › Pump
Issued 19 June 2014
Resolved
The bilge system pump is inoperable. Repair and prove proper operation prior to carrying passengers. 46 CFR 182.25-10
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 July 2014
Resolution: bilge pump was renewed, and tested all sat.
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2011
Resolved
Vessel has not verified compliance with new AAWP (185lb) standard. Total persons allowed on board as per the current COI is now reduced from 31 to 23.
Due 1 June 2012
Resolved 3 May 2012
Resolution: Simplified stability test was conducted reducing persons on board from 28 to 27.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 June 2004
Resolved
Install lifejacket donning placards for both types.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Electrical Distribution System (service) › Switch
Issued 16 June 2004
Resolved
Label bilge alarm switch to be "ON" while operating.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 June 2004
Resolved
Remove or strap up and tape dead end wires in forward compartment.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 June 2004
Resolved
Update expired items in first aid kit.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 16 June 2004
Resolved
Mount flashlight at operating station.
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 7 July 2004
Documentation
Issued 6 June 2001
Resolved
Prove compliance of enrollment in an approved CG drug and alcohol testing program.
Condition: Unknown
Due 22 June 2001
Resolved 9 April 2002
Resolution: Changed manning on all three vessels. Changed deckhand to person in addition of the crew to eliminate them from the required drug testing requirements. The deckhand was a NPS employee and the union would not allow them to be tested IAW CG requirements.
Lifesaving
Issued 10 June 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 June 1992
Resolved 10 June 1992
Lifesaving
Issued 11 June 1991
Resolved
PRIOR TO CARRYING PASSENGERS CONDUCT EMERGENCY DRILLS WITH OPERATORS AND DECKHANDS AS OUTLINED IN NAVIC 1-91 DTD 20 FEB 91 IN PRESENCE OF COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991