Records from 1985 to 1994. Most recent: inspection, 13 December 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
13 December 1994
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164704
31 March 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 87381
19 January 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162481
16 November 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 842443
29 June 1993
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841194
12 November 1992
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 962998
12 December 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942275
14 November 1991
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938542
5 September 1991
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 940678
10 December 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229392
22 August 1990
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 909338
27 June 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1227656
27 June 1990
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1246927
4 December 1989
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1212937
9 December 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1209553
22 November 1988
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 893539
9 December 1987
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000931
24 June 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1309968
10 December 1986
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1026701
6 May 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1000730
12 December 1985
COI Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1298343
29 March 1985
Credit Drydock · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 986085
Documentation
Issued 13 December 1994
Resolved
PROVIDE WRITTEN DRUG POLICYAND SELF HELP OPTION FOR EMPLOYEES.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 13 December 1994
Resolved
RESPLICE ANCHOR LINE
Condition: Unknown
Due 13 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 December 1994
Resolved
PROPERLY RIG LIFEFLOAT AND PROVIDE RETRO TAPE FOR LIFE FLOAT.
Condition: Unknown
Due 13 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 13 December 1994
Resolved
MAKE ENGINE ROOM READY FOR INSPECTION AND MAKE VSL AVAILABLE FOR UNDERWAY INSPECTION.
Condition: Unknown
Due 13 January 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 November 1993
Resolved
REPAIR COLLISION BULKHEAD TO PROVIDE REQUIRED WATERTIGHT INTIGRATY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993
Construction/Loadline
Issued 16 November 1993
Resolved
REPAIR OR REPLACE WOOD MEMBERS FORWARD OF COLLISION BULKHEAD TO CORRECT LEAKING CONDITION OF HULL, TO THE SATISFACTION OF THE CHIEF OF THE INSPECTION OFFICE.
Condition: Unknown
Due 16 November 1993
Resolved 16 November 1993
Unknown
Issued 12 November 1992
Resolved
ENROLL AND PROVE PARTICIPATION IN RANDOM DRUG TESTING PROGRAM FOR ALL EMPLOYEES.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Construction/Loadline
Issued 10 December 1990
Resolved
REPLACE THE PLASTIC THRU-HULL FITTINGS WITH METALLIC THRU-HULLS AND PROVIDE EACH WITH METALLIC VALVES THAT ARE WITHIN 6" FROM THE WATERS EDGE.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Construction/Loadline
Issued 10 December 1990
Resolved
REPLACE THE ROTTEN UNDER DECK BEAMS IN THE ENGINE ROOM PORT/STBD AFT.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Construction/Loadline
Issued 10 December 1990
Resolved
CROP AND RENEW THE DECK IN WAY OF THE TACKEL CENTER.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990
Resolved
PROVIDE AN ELECTRICAL WIRING DIAGRAM FOR PROPOSED WIRING CONNECTION TO THE MAIN SWITCHBOARDS.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Engineering
Issued 10 December 1990
Resolved
PROVIDE AND INSTALL A FIXED HAND OR POWER BILGE PUMP IAW 46CFR182.25-10(A).
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990
Resolved
REMOVE THE GREY WIRE CONDUCTOR THAT IS USED ON THE VESSEL EXTENSIVELY_x001C_ IAW 46 CFR 183.05-45.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Engineering
Issued 10 December 1990
Resolved
INSTALL A FIXED BILGE SYSTEM/PIPING IAW 46CFR182.25-5(A).
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Electrical
Issued 10 December 1990
Resolved
INSTALL ADEQUATE EMERGENCY LIGHTS THAT ACTUATE AUTOMATICALLY UPON LOSS OF THE PRIMARY LIGHTING SYSTEM.
Condition: Unknown
Due 10 December 1990
Resolved 10 December 1990
Engineering
Issued 4 December 1989
Resolved
REPLACE FLEXIBLE FUEL LINES WITH COPPER, COPPER NICKEL, NICKEL COPPER PIPING, BOTH SUPPLY AND RETURN, HAVING A MINIMUM WALL THICKNESS OF 0.035 INCH IN ACCORDANCE WITH 46CFR182.20-40
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Lifesaving
Issued 4 December 1989
Resolved
ATTACH PENDANTS TO BUOYANT APPARATUS AT LEAST EVERY 18 INCHES.
Condition: Unknown
Due 4 December 1989
Resolved 4 December 1989
Engineering
Issued 22 November 1988
Resolved
INSTALL PLUGS IN FUEL OIL FILTER DRAIN COCKS.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Construction/Loadline
Issued 22 November 1988
Resolved
INVESTIGATE AND REPAIR LEAK IN FRAME BAY JUST FORWARD OF THE STARBOARD FUEL TANK.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988
Resolved
PROPERLY WIRE 110 VOLT CIRCUIT IN FORWARD CABIN AREA IN ACCORDANCE WITH 46 CFR PART 183.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Construction/Loadline
Issued 9 December 1987
Resolved
INSTALL CAPTIVE CHAIN OR OTHER DEVICE ON MAIN DECK WATERTIGHT HATCH COVER, AFT DECK AREA, AND CONNECT IT TO HATCH FRAME TO PREVENT LOSS.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Lifesaving
Issued 9 December 1987
Resolved
INSTALL PROPER SIZE FLOAT-FREE LINK ON BUOYANT APPARATUS AND RE-NEW LIFE- LINES WITH NATURALLY BUOYANT LINES OR LINES WITH SEINE FLOATS.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Engineering
Issued 9 December 1987
Resolved
RE-NEW STARBOARD ENGINE EXHAUST COOLING WATER HOSE.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987
Accommodation/Occupational Safety
Issued 9 December 1987
Resolved
DOUBLE-CLAMP BAIT WELL HOSES IN LAZARETTE.
Condition: Unknown
Due 9 December 1987
Resolved 9 December 1987