MAURY USCG vessel records Sign in
← All vessels

GULFSTREAM II

GULFSTREAM II is a 1981 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1985, most recently in February 2026, along with 100 deficiencies and 2 casualty investigations between 2006 and 2007.

Records from 1985 to 2026. Most recent: inspection, 17 February 2026.

Built
1981
Last inspected
17 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYR6262
Flag
UNITED STATES
367317030
Maury page id
psix-52542

Inspections, by type

…with no type recorded10
Years with a record 39 calendar years (1985–2026)
The 80 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 14.8 ft × 7.8 ft
Registered tonnagegross 36 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE MANAGEMENT CORP · MEDLEY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYR6262MMSI 367317030 · active · compulsorily equipped · granted 11 October 2017, expires 25 November 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 80

17 February 2026 Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290921
13 August 2025 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8188603
15 August 2024 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7971355
13 February 2024 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7850324
19 July 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7746780
25 May 2022 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7444554
1 February 2022 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7377912
8 June 2021 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199044
17 August 2020 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024860
11 February 2020 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6891326
31 October 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6846038
6 September 2019 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6805401
31 July 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6767071
21 August 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6507350
4 August 2018 Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 6502237
6 February 2018 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325112
8 June 2017 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6152065
3 August 2016 DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5960454
2 February 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5805366
27 August 2015 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5227791
29 May 2012 Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4326673
14 February 2012 Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4243912
19 September 2011 Inclining Experiment · Deadweight Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4148781
28 July 2011 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4097470
16 February 2010 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3696742
6 July 2009 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3525300
24 November 2008 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3368694
25 June 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3249777
13 February 2008 Hull Examination · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3146018
14 October 2007 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3083192
30 May 2007 COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2944771
20 September 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2782799
12 June 2006 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2673099
14 February 2006 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2585412
15 June 2005 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2390494
17 September 2004 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2197824
19 February 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2000428
20 November 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1951588
11 July 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1840759
3 June 2002 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1622823
22 February 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1488104
23 April 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406911
3 April 2001 Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 1520910
20 February 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058303
12 January 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376441
22 March 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406677
26 April 1999 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386573
23 June 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 727083
27 May 1998 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438737
23 April 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 209998
19 January 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116535
28 April 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1425932
26 April 1996 Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078582
31 August 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879957
27 April 1995 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872154
29 April 1994 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1168823
27 May 1993 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 831784
24 May 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 32275
29 April 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149924
2 April 1993 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145932
1 December 1992 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1133013
5 October 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 933427
1 June 1992 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946899
16 March 1992 Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 664474
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937644
17 June 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352386
6 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918029
7 January 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210851
11 December 1990 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235971
20 August 1990 Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920017
19 June 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236854
2 May 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223425
26 July 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341895
28 June 1989 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1044855
6 June 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039216
1 December 1987 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027960
27 April 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1026241
6 June 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297902
5 May 1986 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1292518
7 May 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1288801

Deficiency record · 100

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2024 Resolved
A pre-engineered fixed gas fire extinguishing system must: Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI Observed the generator didn't shut off when the pre-engineered fixed system was activated. Afterwards the main engine didn't start when attempting to get underway. Vessel must rectify issue and provide a service report for the pre-engineered system. Vessel must rectify prior to the carriage of passengers. 46 CFR 181.420 (a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2024
Resolved 16 August 2024
Resolution: Reinspected system with service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each lifejacket, work vest, and marine buoyant device. MI Observed faded retro reflective tape on life jackets. Vessel Operator has 3 days to rectify . 46 CFR 176.808 (a)(2)
Action required: 705 - Other - as specified
Due 15 August 2024
Resolved 16 August 2024
Resolution: Life jackets serviced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2024 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel didn't have a fire detection in the bathroom area. Vessel must keep the door open until fire detection is installed in the bathroom. 46 CFR 181.405 (c)
Action required: 705 - Other - as specified
Due 15 August 2024
Resolved 16 August 2024
Resolution: Vessel installe smoke detection in bathroom.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment and systems, including the following: Inspection of all cable as far as practicable without undue disturbance of the cable or electrical apparatus. MI Observed a cracked electrical outlet in the starboard bathroom. 46 CFR 176.806 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 16 August 2024
Resolution: Outlet was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 August 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Vessel did not have charts on-board. 46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 22 August 2024
Resolution: Received pictures of new charts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended here:(ii) Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Vessel did not have a monthly maintenance log for fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2024
Resolved 16 August 2024
Resolution: Vessel Operator created a fire extinguisher check log.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 2 August 2023 Resolved
A suitable rescue boat shall be required except when, in the opinion of the Officer in Charge, Marine Inspection, the vessel is of such design and operating characteristics that the vessel itself provides a fully satisfactory rescue platform. 46 CFR 180.10-35(a) MI observed vessel did not have rescue platform to properly bring unconscious passenger on board during MOB drill. Vessel must provide an approved type rescue platform IAW local work instruction and demonstrate the recovery of a PIW in the presence of a CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Conducted MOB using rescue sling system; all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2023 Resolved
An interconnected detection and alarm system must: (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. 46 CFR 181.450(a)(2) MI observed vessel does not have interconnected fire detection and alarm system installed on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Interconnected fire detection system operates SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 2 August 2023 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of the individual who was directly involved in the SMI. 46 CFR 4.06-15(a)(1) MI observed alcohol testing swabs on board were expired and vessel Capt must store in an area that is within temperature rating as noted on swab package.
Action required: 705 - Other - as specified
Due 9 August 2023
Resolved 8 August 2023
Resolution: Swabs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2023 Resolved
Each life preserver carried on a vessel must have at least 200 sq. cm (31 sq. in) of retroreflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides. 46 CFR 180.25-25(a) MI observed six of the vessel's adult personal floatation devices had deteriorating retroreflective material that must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: Retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2023 Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and float-free link. The float-free link must be (iii) Secured to the painter at one end and secured to the vessel on the other end. 46 CFR 180.20(a)(1) MI observed both float-free links for the vessel's life floats were not attached to the vessel.
Action required: 705 - Other - as specified
Due 9 August 2023
Resolved 8 August 2023
Resolution: Link installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. 46 CFR 177.35-15(a) MI observed the accessory belt of the vessel's generator is missing a safety guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 8 August 2023
Resolution: Guard installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023 Resolved
The certification of inspection shall, in general, be framed under glass or other transparent material and posted in a conspicuous place. 46 CFR 176.01-40(a) MI observed vessel's COI was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: COI posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023 Resolved
If a stability letter is issued in accordance with the requirements in 170.120 of this chapter, it must be posted under glass of other suitable transparent material in the pilothouse of the vessel. 46 CFR 185.12-1(a) MI observed vessel's stability letter was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: Stability letter posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2023 Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions. 46 CFR 185.364 MI observed vessel Capt did not include use of potentially hazardous items in passenger safety brief. There shall be one dedicated and labeled area where passenger/crew electronics can be charged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Passenger instructions for potentially hazardous items posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2022 Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. MI observed that life ring's plug was wasted. The life ring no longer meets the USCG Q specification. 46 CFR 180.70 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: The operator purchased a new USCG approved life ring and placed it into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2022 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI discovered that 01 child life jacket was made from kapok and wasted, 01 adult foam life jacket was wasted. 46 CFR 180.71(a)(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: One new CG approved adult lifejacket was purchased by the owner and placed onboard for service.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2022 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI observed that rudder post is actively leaking water at the packing gland. The rate of leakage is estimated to be more than 1 gallon per hour. 46 CCR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: The operator replaced the packing gland for the rudder tube and tightened the rudder post packing to prevent leakage.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 25 May 2022 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection." MI discovered that all 4 escape hatches on the vessel are not properly marked. 46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: All emergency escape hatches are marked with the required markings.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 May 2022 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate. MI discovered that the master's medical certificate is expired. 46 CFR 15.401(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 8 June 2022
Resolution: The master/owner applied for a new medical card through the USCG REC.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2022 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space. Audible alarm not functioning for laz and steering spaces. 46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: The owner installed an audible and visual bilge high water alarm for the laz space and steering space. The alarm is located at the operating station. MI witnessed a satisfactory test of the alarm.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 August 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Replace expired ammonia inhalants, aspirin, and eye-wash. 46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vsl rep replaced expired ammonia inhalents, aspirin, and eye-wash.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2020 Resolved
Each ring buoy must be marked in clearly legible block capital letters with the vessel's name. Place name of vessel on ring life buoy. 46CFR195.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vsl rep put vsl name on ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in a manner to prevent chaffing. 46CFR183.340(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed metal supports.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 February 2020 Resolved
Each lighting fixture globe, lens must have a guard or be made of high strength material. 46CFR183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed guard for lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020 Resolved
All cable and wire must be protected by metal covering or other suitable means. 46CFR183.340(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed cover for electrical connections.
Engineering › Bilge Water Management System › Valve
Issued 8 June 2017 Resolved
Install shutoff valves on submersible electric bilge discharge lines as close to hull and as high above water line as possible iaw 46CFR182.520(e)(7).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 October 2017
Resolution: Three ball valves installed.
Lifesaving › Lifebuoys › Approval
Issued 8 June 2017 Resolved
Replace ringe life bouy with USCG approved 24" ring life bouy iaw 46CFR180.30-1(a).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 8 June 2017
Resolution: Vessel rep purchased new approved ring life bouy prior to the departure of the marine inspectors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2017 Resolved
Waterlight for battery expired, replace with new iaw 46CFR180.30-1(b). Restricted to daytime operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 June 2017
Resolution: Vessel rep purchased valid battery for waterlight prior to the departure of marine inspectors.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2017 Resolved
Make VHF-FM radio DSC capable iaw 46CFR184.502.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 19 June 2017
Resolution: Vessel rep proved VHF-FM radio has DSC capabilities, MMSI entered.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 August 2015 Resolved
Properly install machinery belt guards on the front of the Main Diesel Engine. 46 CFR 177.960
Due 27 September 2015
Resolved 25 September 2015
Resolution: Fabricated and installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 August 2015 Resolved
Install individual audible/visual alarms for each space requiring bilge high level alarms. 46 CFR 182.530
Due 27 September 2015
Resolved 25 September 2015
Resolution: Fabricated and Installed.
Construction/Loadline › Structures › Scuttle
Issued 27 August 2015 Resolved
Attached a captive chain or device to the forepeak hatch. 46 CFR 171.124
Due 27 September 2015
Resolved 27 August 2015
Resolution: Corrected on the spot.
Operations/Management › Passenger Operations › Safety Orientation
Issued 27 August 2015 Resolved
Post life jacket placards for type of child sized life jackets on board. 46 CFR 185.516
Due 27 September 2015
Resolved 25 September 2015
Resolution: Printed instructions displayed.
Operations/Management › Passenger Operations › Safety Orientation
Issued 29 May 2012 Resolved
Upper deck not marked for maximum number of passengers. Provide markings for maximum number of passengers IAW stability test. 46CFR185.602(g)
Condition: Improper/Lack of Maintenance
Due 30 June 2012
Resolved 8 June 2012
Resolution: POC provided picture of new marking placed on ladder proceeding to upper deck stating that a max of 5 pax allowed.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2011 Resolved
Provide current navigation charts (current to within one year as per OCMI) as per 46 CFR 184.420.
Due 4 August 2011
Resolved 3 August 2011
Resolution: Owner provided current navigation charts for operating area.
Stability › Incline Test › General
Issued 13 February 2008 Resolved
Conduct simplified stability test.
Action required: 705 - Other - as specified
Due 10 October 2009
Resolved 8 December 2011
Resolution: MSC issued deadwt survey stability letter of this date.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 February 2008 Resolved
Show proper operation of engine shut-down system utilizing the fixed fire fighting system in test mode.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 February 2008 Resolved
Show proper underway operations of new propulsion engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 February 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 May 2007 Resolved
Provide a drug/alcohol testing device. O/O claims he knew nothing about the requirement and ordered a kit while onboard from APCA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 19 June 2007
Resolution: New test kit were purchased and onboard.
Engineering › Bilge Water Management System › Pump
Issued 30 May 2007 Resolved
Provide a 5 GPM portable hand pump. Hand pump onboard could not get a vacuum.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2007
Resolved 19 June 2007
Resolution: New portable pump was purchased and onboard.
Communications › Radio Communications › EPIRB
Issued 30 May 2007 Resolved
Prior to the carriage of passengers past 20 NM from a harbor of safe refuge, provide a new EPIRB antenna. The antenna is cracked in several places. Vessel has 100% LF's onboard to operate out to 20NM's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 19 June 2007
Resolution: New antenna was purchased and installed on the EPIRB.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2007 Resolved
Provide a rescue platform and prove proper man overboard recovery. Vessel is utilizing the LF that is on the bow for a rescue platform.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 July 2007
Resolved 8 August 2007
Resolution: Rescue platform was fabricated by the owner and a satisfactory test was witnessed by a CG Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 September 2004 Resolved
REPLACE HOSE CLAMPS ON SHAFT BOOT PRIOR TO CARRIAGE OF PASSENGERS.
Due 17 October 2004
Resolved 27 October 2004
Resolution: Fax Documentation.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 September 2004 Resolved
REPLACE RETROFLECTIVE MATERIAL ON 3 CHILD SIZE LIFE JACKETS PRIOR TO CARRIAGE OF PASSENGERS.
Due 17 October 2004
Resolved 27 October 2004
Resolution: Fax Documentation.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 September 2004 Resolved
ADJUST EMERGENCY PROCEDURES TO REFLECT ACTUAL PROCEDURE FOR EACH EMERGENCY SITUATION.
Due 17 October 2004
Resolved 27 October 2004
Resolution: Fax Documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2004 Resolved
Owner/Operator failed to make vessel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI.
Due 17 September 2004
Resolved 17 September 2004
Resolution: Inspector attended vessel and conducted annual inspection.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 July 2003 Resolved
Replace engine securing relay prior to the carriage of passengers.
Condition: Unknown
Due 11 July 2003
Resolved 11 July 2003
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 11 July 2003 Resolved
Prior to the carriage of passengers, replace retro-reflective tape as needed on life preservers.
Condition: Improper/Lack of Maintenance
Due 11 July 2003
Resolved 11 July 2003
Engineering › Fuel Oil Service System
Issued 11 July 2003 Resolved
Repair fuel oil leak coming from discharge fitting on the PORT fuel oil tank. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 11 August 2003
Resolved 25 February 2004
Resolution: CORRECTED.
Lifesaving › Lifebuoys
Issued 3 June 2002 Resolved
REPAIR/REPLACE LIFERING PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 10 June 2002
Resolved 11 July 2003
Engineering › Fuel Oil Service System
Issued 3 June 2002 Resolved
INSTALL METALLIC VALVE ON FUEL STRAINERS. VALVES MUST BE PLUGGED OR CAPPED TO PREVENT LEAKAGE. LEGACY COMPONENT DESC: Filter
Condition: Improper Installation
Due 3 July 2002
Resolved 11 July 2003
Fire Fighting › Fire Hoses
Issued 3 June 2002 Resolved
INSTALL LENGTH OF HOSE LONG ENOUGH TO REACH EACH AREA OF VESSEL (MINIMUM 50 FEET) PRIOR TO CARRIAGE OF PASSENGERS.. LEGACY COMPONENT DESC: Length
Condition: Improper Installation
Due 10 June 2002
Resolved 11 July 2003
Engineering
Issued 12 January 2001 Resolved
PROVIDE MACHINERY GUARDS FOR MAIN PROPULSION ENGINES.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Documentation
Issued 12 January 2001 Resolved
PROVIDE PROOF OF VALID FCC RADIO SAFETY CERTIFICATE. VSLS IS RESTRICTED TONO MORE THAN 1,000 FT FROM SHORE UNTILL REQUIREMENT IS CLEARED.
Condition: Unknown
Due 13 January 2001
Resolved 5 February 2001
Lifesaving
Issued 12 January 2001 Resolved
PROVIDE CREW EMERGENCY TRAINING AND EMERGENCY EQUIPMENT LOG BOOK.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Lifesaving
Issued 12 January 2001 Resolved
PROVIDE CLIP FOR RING LIFE BUOY LIGHT LINE.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Lifesaving
Issued 12 January 2001 Resolved
RENEW YELLOW PULL LINE ON EPIRB.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Navigation
Issued 12 January 2001 Resolved
PROVIDE TIDE AND CURRENT TABLES FOR OPERATIONAL AREA.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Fire Fighting
Issued 12 January 2001 Resolved
PROVIDE PROPER VENT CLOSURES FOR ENGINE ROOM VENTS FOR FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Lifesaving
Issued 12 January 2001 Resolved
PROVIDE MEANS TO RETRIEVE HELPLESS PERSON FROM WATER.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Lifesaving
Issued 12 January 2001 Resolved
UP-DATE CREW EMERGENCY INSTRUCTIONS FOR RETRIEVAL OF PERSON IN WATER.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Fire Fighting
Issued 26 April 1999 Resolved
CONVERT CURRRENT FIXED FIREFIGHTING SYSTEM TO COMPLY WITH ALARM REQUIREMENTS.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Documentation
Issued 26 April 1999 Resolved
PROVIDE FCC OPERATORS LICENSE.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Lifesaving
Issued 26 April 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Documentation
Issued 26 April 1999 Resolved
INITIATE: DRILL/TRNG LOG IAW 46 CFR 185.520 AND 185.524; EPIRB MAINTENANCE AND INSPECTION OF LIFESAVING EQUIP LOGS IAW 46 CFR 185 SUBPART G.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Lifesaving
Issued 26 April 1999 Resolved
SCHEDULE U/W MOB AND FIREFIGHTING DRILLS UNDER USCG EVAL.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Documentation
Issued 26 April 1999 Resolved
COMPLY WITH REQUIREMENTS ON DRUG CONSORTIUM AUDIT FORM.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Documentation
Issued 26 April 1999 Resolved
PROVIDE DOCUMENT STICKER FOR 1999.
Condition: Unknown
Due 19 August 1999
Resolved 19 August 1999
Documentation
Issued 26 April 1996 Resolved
PROVIDE AN ONE HOUR DRUG AWARENESS TRAINING FOR ALL LICENSED PERSONS.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Navigation
Issued 26 April 1996 Resolved
PROVIDE A BOX FOR FCC RADIO BATTERY.
Condition: Unknown
Due 8 July 1996
Resolved 8 July 1996
Engineering
Issued 29 April 1993 Resolved
Renew fuel vent flame screens.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Engineering
Issued 29 April 1993 Resolved
Re-label emergency fuel shutdown.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Navigation
Issued 1 June 1992 Resolved
Replace lens on both NAV lts.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Lifesaving
Issued 1 June 1992 Resolved
STENCIL 10 PFD'S WITH VESSELS NAME.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Documentation
Issued 1 June 1992 Resolved
Provide FCC operators license.
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Lifesaving
Issued 1 June 1992 Resolved
Provide 406 MHZ EPIRB or class A EPIRB manufactured after 01OCT88._x001C_
Condition: Unknown
Due 1 June 1992
Resolved 1 June 1992
Engineering
Issued 11 December 1990 Resolved
REPLACE SHAFT LOG HOSE CLAMPS.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Construction/Loadline
Issued 11 December 1990 Resolved
FOAM SEAL E/R FWD BHD, PORT LOWER.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Navigation
Issued 11 December 1990 Resolved
RENEW EPIRB BATTERY PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Electrical
Issued 11 December 1990 Resolved
CRIMP TYPE SPLICES ONLY TO BE USED BILGE PUMP WIRING.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Lifesaving
Issued 11 December 1990 Resolved
REPAIR RING BUOY WATER LIGHT AND PROVIDE 60' LINE ATTACHED TO RING BUOY.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Lifesaving
Issued 11 December 1990 Resolved
REPAIR PORT WATER LIGHT ON LIFEFLOAT AND ATTACH BOTH LIGHTS WITH 18' LINE TO FLOAT.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Construction/Loadline
Issued 11 December 1990 Resolved
INSTALL CAPTIVE CHAIN BOW HATCH.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Construction/Loadline
Issued 11 December 1990 Resolved
REPAIR DAMAGE STERN END OF KEEL.
Condition: Unknown
Due 11 December 1990
Resolved 11 December 1990
Electrical
Issued 19 June 1990 Resolved
SUMMIT A SKETCH OF WIRING SYSTEM SHOWING HOW AIR CONDITIONERS ARE CONNECTEDAND WHERE AMMETER IS. SHOW WIRE SIZE AND TYPE CIRCUIT BREAKER SIZE.
Condition: Unknown
Due 19 June 1990
Resolved 19 June 1990
Electrical
Issued 2 May 1990 Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF S/S GENERATOR.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
RENEW FLOAT-FREE LINKS ON BOTH LIFEFLOATS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 28 June 1989 Resolved
SEPARATE FUEL SHUT-OFF VALVES FROM FUEL TANK COMPARTMENT.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Navigation
Issued 28 June 1989 Resolved
MARK EPIRB WITH VESSEL'S NAME.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Electrical
Issued 28 June 1989 Resolved
PROVIDE COVER FOR GENERATOR START BATTERY.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 28 June 1989 Resolved
PROVIDE 60' OF LINE ATTACHED TO RING BUOY.
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Documentation
Issued 6 June 1989 Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Documentation
Issued 6 June 1989 Resolved
DRYDOCK DUE 06DEC90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Deck/Cargo
Issued 6 June 1989 Resolved
RENEW WASTED WATER TANK HOSE CLAMPS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 6 June 1989 Resolved
REPAIR LOOSE SHAFT LOG HOSE.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Construction/Loadline
Issued 6 June 1989 Resolved
INSTALL CAPTURE CHAINS ON ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 6 June 1989 Resolved
INSTALL HEAT SHIELD KITS FOR 2 RACOR FUEL FILTERS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Electrical
Issued 6 June 1989 Resolved
MOUNT THE GENERATOR MUFFLER.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Electrical
Issued 6 June 1989 Resolved
REPAIR GENERATOR MUFFLER INLET HOSE CONNECTION.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989

Casualty record · 2

20 September 2006Routine · role: Involved in a Marine Casualty · activity 2782799
14 October 2007Routine · role: Involved in a Marine Casualty · activity 3083192
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record