Records from 2006 to 2026. Most recent: inspection, 17 February 2026.
Inspection history · 19
17 February 2026
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290921
13 August 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8188603
15 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7971355
13 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7850324
19 July 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7746780
25 May 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7444554
1 February 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7377912
8 June 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199044
17 August 2020
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024860
11 February 2020
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6891326
31 October 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6846038
6 September 2019
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6805401
31 July 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6767071
21 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6507350
4 August 2018
Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 6502237
6 February 2018
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325112
8 June 2017
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6152065
3 August 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5960454
2 February 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5805366
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2024
Resolved
A pre-engineered fixed gas fire extinguishing system
must: Automatically shut down all power ventilation
systems and all engines that draw intake air from within
the protected space. MI Observed the generator didn't
shut off when the pre-engineered fixed system was
activated. Afterwards the main engine didn't start when
attempting to get underway.
Vessel must rectify issue and provide a service report
for the pre-engineered system. Vessel must rectify prior
to the carriage of passengers.
46 CFR 181.420 (a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 August 2024
Resolved 16 August 2024
Resolution: Reinspected system with service report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have the
vessel ready for inspection of lifesaving equipment and
systems, including the following: Inspection of each
lifejacket, work vest, and marine buoyant device. MI
Observed faded retro reflective tape on life jackets.
Vessel Operator has 3 days to rectify .
46 CFR 176.808 (a)(2)
Action required: 705 - Other - as specified
Due 15 August 2024
Resolved 16 August 2024
Resolution: Life jackets serviced.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an
interconnected fire detection system in compliance with
§ 181.450 installed in all enclosed areas where
passengers and crew have routine access, including
accommodation spaces and machinery spaces. Vessel
didn't have a fire detection in the bathroom area.
Vessel must keep the door open until fire detection is
installed in the bathroom.
46 CFR 181.405 (c)
Action required: 705 - Other - as specified
Due 15 August 2024
Resolved 16 August 2024
Resolution: Vessel installe smoke detection in bathroom.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have the
vessel ready for inspection of electrical equipment and
systems, including the following: Inspection of all
cable as far as practicable without undue disturbance of
the cable or electrical apparatus. MI Observed a cracked
electrical outlet in the starboard bathroom.
46 CFR 176.806 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 16 August 2024
Resolution: Outlet was replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 August 2024
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: Vessel did not have
charts on-board.
46 CFR 184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2024
Resolved 22 August 2024
Resolution: Received pictures of new charts.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024
Resolved
Portable and semi-portable extinguishers must be
inspected and maintained in accordance with NFPA 10
(incorporated by reference, see § 175.600 of this
chapter) as amended here:(ii) Monthly inspections
required by NFPA 10 may be conducted by the owner,
operator, person-in-charge, or a designated member of
the crew. Vessel did not have a monthly maintenance log
for fire extinguishers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2024
Resolved 16 August 2024
Resolution: Vessel Operator created a fire extinguisher check log.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 2 August 2023
Resolved
A suitable rescue boat shall be required except when, in the opinion of the Officer in Charge, Marine Inspection, the vessel is of such design and operating characteristics that the vessel itself provides a fully satisfactory rescue platform.
46 CFR 180.10-35(a)
MI observed vessel did not have rescue platform to properly bring unconscious passenger on board during MOB drill. Vessel must provide an approved type rescue platform IAW local work instruction and demonstrate the recovery of a PIW in the presence of a CG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Conducted MOB using rescue sling system; all SAT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2023
Resolved
An interconnected detection and alarm system must: (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system.
46 CFR 181.450(a)(2)
MI observed vessel does not have interconnected fire detection and alarm system installed on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Interconnected fire detection system operates SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 2 August 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of the individual who was directly involved in the SMI.
46 CFR 4.06-15(a)(1)
MI observed alcohol testing swabs on board were expired and vessel Capt must store in an area that is within temperature rating as noted on swab package.
Action required: 705 - Other - as specified
Due 9 August 2023
Resolved 8 August 2023
Resolution: Swabs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2023
Resolved
Each life preserver carried on a vessel must have at least 200 sq. cm (31 sq. in) of retroreflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides.
46 CFR 180.25-25(a)
MI observed six of the vessel's adult personal floatation devices had deteriorating retroreflective material that must be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: Retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2023
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and float-free link. The float-free link must be (iii) Secured to the painter at one end and secured to the vessel on the other end.
46 CFR 180.20(a)(1)
MI observed both float-free links for the vessel's life floats were not attached to the vessel.
Action required: 705 - Other - as specified
Due 9 August 2023
Resolved 8 August 2023
Resolution: Link installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
46 CFR 177.35-15(a)
MI observed the accessory belt of the vessel's generator is missing a safety guard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 8 August 2023
Resolution: Guard installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023
Resolved
The certification of inspection shall, in general, be framed under glass or other transparent material and posted in a conspicuous place.
46 CFR 176.01-40(a)
MI observed vessel's COI was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: COI posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023
Resolved
If a stability letter is issued in accordance with the requirements in 170.120 of this chapter, it must be posted under glass of other suitable transparent material in the pilothouse of the vessel.
46 CFR 185.12-1(a)
MI observed vessel's stability letter was not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 August 2023
Resolved 8 August 2023
Resolution: Stability letter posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2023
Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
46 CFR 185.364
MI observed vessel Capt did not include use of potentially hazardous items in passenger safety brief.
There shall be one dedicated and labeled area where passenger/crew electronics can be charged.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2023
Resolved 3 November 2023
Resolution: Passenger instructions for potentially hazardous items posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2022
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter.
MI observed that life ring's plug was wasted. The life ring no longer meets the USCG Q specification.
46 CFR 180.70 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: The operator purchased a new USCG approved life ring and placed it into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided.
MI discovered that 01 child life jacket was made from kapok and wasted, 01 adult foam life jacket was wasted.
46 CFR 180.71(a)(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: One new CG approved adult lifejacket was purchased by the owner and placed onboard for service.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2022
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended.
MI observed that rudder post is actively leaking water at the packing gland. The rate of leakage is estimated to be more than 1 gallon per hour.
46 CCR 181.610
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: The operator replaced the packing gland for the rudder tube and tightened the rudder post packing to prevent leakage.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 25 May 2022
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection."
MI discovered that all 4 escape hatches on the vessel are not properly marked.
46 CFR 185.30-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2022
Resolved 8 June 2022
Resolution: All emergency escape hatches are marked with the required markings.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 May 2022
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate.
MI discovered that the master's medical certificate is expired.
46 CFR 15.401(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 8 June 2022
Resolution: The master/owner applied for a new medical card through the USCG REC.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space.
Audible alarm not functioning for laz and steering spaces.
46 CFR 182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 16 June 2022
Resolution: The owner installed an audible and visual bilge high water alarm for the laz space and steering space. The alarm is located at the operating station. MI witnessed a satisfactory test of the alarm.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Replace expired ammonia inhalants, aspirin, and eye-wash.
46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vsl rep replaced expired ammonia inhalents, aspirin, and eye-wash.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2020
Resolved
Each ring buoy must be marked in clearly legible block capital letters with the vessel's name.
Place name of vessel on ring life buoy.
46CFR195.604(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 August 2020
Resolved 31 August 2020
Resolution: Vsl rep put vsl name on ring buoy.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in a manner to prevent chaffing. 46CFR183.340(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed metal supports.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 February 2020
Resolved
Each lighting fixture globe, lens must have a guard or be made of high strength material. 46CFR183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed guard for lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020
Resolved
All cable and wire must be protected by metal covering or other suitable means. 46CFR183.340(6)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2020
Resolved 24 February 2020
Resolution: Operator installed cover for electrical connections.
Engineering › Bilge Water Management System › Valve
Issued 8 June 2017
Resolved
Install shutoff valves on submersible electric bilge discharge lines as close to hull and as high above water line as possible iaw 46CFR182.520(e)(7).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 30 October 2017
Resolution: Three ball valves installed.
Lifesaving › Lifebuoys › Approval
Issued 8 June 2017
Resolved
Replace ringe life bouy with USCG approved 24" ring life bouy iaw 46CFR180.30-1(a).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 8 June 2017
Resolution: Vessel rep purchased new approved ring life bouy prior to the departure of the marine inspectors.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2017
Resolved
Waterlight for battery expired, replace with new iaw 46CFR180.30-1(b). Restricted to daytime operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 8 June 2017
Resolution: Vessel rep purchased valid battery for waterlight prior to the departure of marine inspectors.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2017
Resolved
Make VHF-FM radio DSC capable iaw 46CFR184.502.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 19 June 2017
Resolution: Vessel rep proved VHF-FM radio has DSC capabilities, MMSI entered.