← All vessels
GULFSTREAM II
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named GULFSTREAM II
GULFSTREAM II is a 1981 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1985, most recently in February 2026, along with 100 deficiencies and 2 casualty investigations between 2006 and 2007.
Records from 1985 to 2026. Most recent: inspection, 17 February 2026.
- Built
- 1981
- Last inspected
- 17 February 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 100 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2006–2007
Identity
633696
WYR6262
52542
Flag
UNITED STATES
367317030
Maury page id
psix-52542
Inspections, by type
…with no type recorded10
Years with a record
39 calendar years (1985–2026)
The 80 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.0 ft × 14.8 ft × 7.8 ft
Registered tonnagegross 36 / net 24
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE MANAGEMENT CORP · MEDLEY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCLEARWATER BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 12 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
24 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WYR6262MMSI 367317030 · active · compulsorily equipped · granted 11 October 2017, expires 25 November 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 80
17 February 2026
Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8290921
13 August 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8188603
15 August 2024
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7971355
13 February 2024
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7850324
19 July 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7746780
25 May 2022
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7444554
1 February 2022
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7377912
8 June 2021
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7199044
17 August 2020
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7024860
11 February 2020
Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6891326
31 October 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6846038
6 September 2019
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6805401
31 July 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6767071
21 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6507350
4 August 2018
Type not recorded
No type recorded · Station St Petersburg · USCG Southeast District (CGD-SE) · Activity 6502237
6 February 2018
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6325112
8 June 2017
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6152065
3 August 2016
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5960454
2 February 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5805366
27 August 2015
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5227791
29 May 2012
Administrative Inspection · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4326673
14 February 2012
Administrative Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4243912
19 September 2011
Inclining Experiment · Deadweight Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4148781
28 July 2011
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4097470
16 February 2010
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3696742
6 July 2009
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3525300
24 November 2008
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3368694
25 June 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3249777
13 February 2008
Hull Examination · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3146018
14 October 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3083192
30 May 2007
COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2944771
20 September 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2782799
12 June 2006
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2673099
14 February 2006
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2585412
15 June 2005
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2390494
17 September 2004
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2197824
19 February 2004
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2000428
20 November 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1951588
11 July 2003
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1840759
3 June 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1622823
22 February 2002
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1488104
23 April 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406911
3 April 2001
Type not recorded
No type recorded · Station Sand Key · USCG Southeast District (CGD-SE) · Activity 1520910
20 February 2001
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1058303
12 January 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1376441
22 March 2000
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1406677
26 April 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386573
23 June 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 727083
27 May 1998
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438737
23 April 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 209998
19 January 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1116535
28 April 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1425932
26 April 1996
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1078582
31 August 1995
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879957
27 April 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872154
29 April 1994
Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1168823
27 May 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 831784
24 May 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 32275
29 April 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1149924
2 April 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145932
1 December 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1133013
5 October 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 933427
1 June 1992
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946899
16 March 1992
Type not recorded
No type recorded · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 664474
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 937644
17 June 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1352386
6 May 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918029
7 January 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1210851
11 December 1990
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1235971
20 August 1990
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 920017
19 June 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1236854
2 May 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223425
26 July 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341895
28 June 1989
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1044855
6 June 1989
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039216
1 December 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1027960
27 April 1987
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1026241
6 June 1986
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297902
5 May 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1292518
7 May 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1288801
Deficiency record · 100
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2024
Resolved
A pre-engineered fixed gas fire extinguishing system
must: Automatically shut down all power ventilation
systems and all engines that draw intake air from within
the protected space. MI Observed the generator didn't
shut off when the pre-engineered fixed system was
activated. Afterwards the main engine didn't start when
attempting to get underway.
Vessel must rectify issue and provide a service report
for the pre-engineered system. Vessel must rectify prior
to the carriage of passengers.
46 CFR 181.420 (a)(3)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have the
vessel ready for inspection of lifesaving equipment and
systems, including the following: Inspection of each
lifejacket, work vest, and marine buoyant device. MI
Observed faded retro reflective tape on life jackets.
Vessel Operator has 3 days to rectify .
46 CFR 176.808 (a)(2)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 August 2024
Resolved
Vessels described by 46 CFR 175.110(c) must have an
interconnected fire detection system in compliance with
§ 181.450 installed in all enclosed areas where
passengers and crew have routine access, including
accommodation spaces and machinery spaces. Vessel
didn't have a fire detection in the bathroom area.
Vessel must keep the door open until fire detection is
installed in the bathroom.
46 CFR 181.405 (c)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 August 2024
Resolved
At each initial and subsequent inspection for
certification of a vessel, the owner or managing
operator shall be prepared to conduct tests and have the
vessel ready for inspection of electrical equipment and
systems, including the following: Inspection of all
cable as far as practicable without undue disturbance of
the cable or electrical apparatus. MI Observed a cracked
electrical outlet in the starboard bathroom.
46 CFR 176.806 (a)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 August 2024
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: Vessel did not have
charts on-board.
46 CFR 184.420
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 August 2024
Resolved
Portable and semi-portable extinguishers must be
inspected and maintained in accordance with NFPA 10
(incorporated by reference, see § 175.600 of this
chapter) as amended here:(ii) Monthly inspections
required by NFPA 10 may be conducted by the owner,
operator, person-in-charge, or a designated member of
the crew. Vessel did not have a monthly maintenance log
for fire extinguishers.
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 2 August 2023
Resolved
A suitable rescue boat shall be required except when, in the opinion of the Officer in Charge, Marine Inspection, the vessel is of such design and operating characteristics that the vessel itself provides a fully satisfactory rescue platform.
46 CFR 180.10-35(a)
MI observed vessel did not have rescue platform to properly bring unconscious passenger on board during MOB drill. Vessel must provide an approved type rescue platform IAW local work instruction and demonstrate the recovery of a PIW in the presence of a CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 August 2023
Resolved
An interconnected detection and alarm system must: (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system.
46 CFR 181.450(a)(2)
MI observed vessel does not have interconnected fire detection and alarm system installed on board.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 2 August 2023
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of the individual who was directly involved in the SMI.
46 CFR 4.06-15(a)(1)
MI observed alcohol testing swabs on board were expired and vessel Capt must store in an area that is within temperature rating as noted on swab package.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 August 2023
Resolved
Each life preserver carried on a vessel must have at least 200 sq. cm (31 sq. in) of retroreflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides.
46 CFR 180.25-25(a)
MI observed six of the vessel's adult personal floatation devices had deteriorating retroreflective material that must be replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 August 2023
Resolved
Each life float and buoyant apparatus must be secured to the vessel by a painter and float-free link. The float-free link must be (iii) Secured to the painter at one end and secured to the vessel on the other end.
46 CFR 180.20(a)(1)
MI observed both float-free links for the vessel's life floats were not attached to the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 August 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc.
46 CFR 177.35-15(a)
MI observed the accessory belt of the vessel's generator is missing a safety guard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023
Resolved
The certification of inspection shall, in general, be framed under glass or other transparent material and posted in a conspicuous place.
46 CFR 176.01-40(a)
MI observed vessel's COI was not posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 August 2023
Resolved
If a stability letter is issued in accordance with the requirements in 170.120 of this chapter, it must be posted under glass of other suitable transparent material in the pilothouse of the vessel.
46 CFR 185.12-1(a)
MI observed vessel's stability letter was not posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 July 2023
Resolved
On vessels described by 46 CFR 175.110(c), flammable items not otherwise covered by the regulations of this subchapter, such as rechargeable batteries, including lithium ion batteries utilized for commercial purposes, must be handled, stored, and operated in a way that mitigates the risk of hazardous conditions.
46 CFR 185.364
MI observed vessel Capt did not include use of potentially hazardous items in passenger safety brief.
There shall be one dedicated and labeled area where passenger/crew electronics can be charged.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 May 2022
Resolved
A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter.
MI observed that life ring's plug was wasted. The life ring no longer meets the USCG Q specification.
46 CFR 180.70 (a)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 25 May 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided.
MI discovered that 01 child life jacket was made from kapok and wasted, 01 adult foam life jacket was wasted.
46 CFR 180.71(a)(b)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 25 May 2022
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended.
MI observed that rudder post is actively leaking water at the packing gland. The rate of leakage is estimated to be more than 1 gallon per hour.
46 CCR 181.610
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 25 May 2022
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear", unless such markings are deemed unnecessary by the Officer in Charge, Marine Inspection."
MI discovered that all 4 escape hatches on the vessel are not properly marked.
46 CFR 185.30-15
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 25 May 2022
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Medical certificates must be issued and will remain current for the following periods of time, unless otherwise noted on the certificate.
MI discovered that the master's medical certificate is expired.
46 CFR 15.401(c)
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 May 2022
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space.
Audible alarm not functioning for laz and steering spaces.
46 CFR 182.530
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 August 2020
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Replace expired ammonia inhalants, aspirin, and eye-wash.
46CFR184.710
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 August 2020
Resolved
Each ring buoy must be marked in clearly legible block capital letters with the vessel's name.
Place name of vessel on ring life buoy.
46CFR195.604(b)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart, and in a manner to prevent chaffing. 46CFR183.340(a)
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 11 February 2020
Resolved
Each lighting fixture globe, lens must have a guard or be made of high strength material. 46CFR183.410(a)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 February 2020
Resolved
All cable and wire must be protected by metal covering or other suitable means. 46CFR183.340(6)
Engineering › Bilge Water Management System › Valve
Issued 8 June 2017
Resolved
Install shutoff valves on submersible electric bilge discharge lines as close to hull and as high above water line as possible iaw 46CFR182.520(e)(7).
Lifesaving › Lifebuoys › Approval
Issued 8 June 2017
Resolved
Replace ringe life bouy with USCG approved 24" ring life bouy iaw 46CFR180.30-1(a).
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 June 2017
Resolved
Waterlight for battery expired, replace with new iaw 46CFR180.30-1(b). Restricted to daytime operations.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 June 2017
Resolved
Make VHF-FM radio DSC capable iaw 46CFR184.502.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 August 2015
Resolved
Properly install machinery belt guards on the front of the Main Diesel Engine. 46 CFR 177.960
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 August 2015
Resolved
Install individual audible/visual alarms for each space requiring bilge high level alarms. 46 CFR 182.530
Construction/Loadline › Structures › Scuttle
Issued 27 August 2015
Resolved
Attached a captive chain or device to the forepeak hatch. 46 CFR 171.124
Operations/Management › Passenger Operations › Safety Orientation
Issued 27 August 2015
Resolved
Post life jacket placards for type of child sized life jackets on board. 46 CFR 185.516
Operations/Management › Passenger Operations › Safety Orientation
Issued 29 May 2012
Resolved
Upper deck not marked for maximum number of passengers. Provide markings for maximum number of passengers IAW stability test. 46CFR185.602(g)
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2011
Resolved
Provide current navigation charts (current to within one year as per OCMI) as per 46 CFR 184.420.
Stability › Incline Test › General
Issued 13 February 2008
Resolved
Conduct simplified stability test.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 February 2008
Resolved
Show proper operation of engine shut-down system utilizing the fixed fire fighting system in test mode.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 February 2008
Resolved
Show proper underway operations of new propulsion engine.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 30 May 2007
Resolved
Provide a drug/alcohol testing device. O/O claims he knew nothing about the requirement and ordered a kit while onboard from APCA.
Engineering › Bilge Water Management System › Pump
Issued 30 May 2007
Resolved
Provide a 5 GPM portable hand pump. Hand pump onboard could not get a vacuum.
Communications › Radio Communications › EPIRB
Issued 30 May 2007
Resolved
Prior to the carriage of passengers past 20 NM from a harbor of safe refuge, provide a new EPIRB antenna. The antenna is cracked in several places. Vessel has 100% LF's onboard to operate out to 20NM's.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 May 2007
Resolved
Provide a rescue platform and prove proper man overboard recovery. Vessel is utilizing the LF that is on the bow for a rescue platform.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 September 2004
Resolved
REPLACE HOSE CLAMPS ON SHAFT BOOT PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 September 2004
Resolved
REPLACE RETROFLECTIVE MATERIAL ON 3 CHILD SIZE LIFE JACKETS PRIOR TO CARRIAGE OF PASSENGERS.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 17 September 2004
Resolved
ADJUST EMERGENCY PROCEDURES TO REFLECT ACTUAL PROCEDURE FOR EACH EMERGENCY SITUATION.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 September 2004
Resolved
Owner/Operator failed to make vessel available for annual inspection w/in 3 months before or after each anniversary date of issuance of the COI.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 11 July 2003
Resolved
Replace engine securing relay prior to the carriage of passengers.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 11 July 2003
Resolved
Prior to the carriage of passengers, replace retro-reflective tape as needed on life preservers.
Engineering › Fuel Oil Service System
Issued 11 July 2003
Resolved
Repair fuel oil leak coming from discharge fitting on the PORT fuel oil tank. LEGACY COMPONENT DESC: Piping
Lifesaving › Lifebuoys
Issued 3 June 2002
Resolved
REPAIR/REPLACE LIFERING PRIOR TO CARRIAGE OF PASSENGERS. LEGACY COMPONENT DESC: Buoyant Lifeline
Engineering › Fuel Oil Service System
Issued 3 June 2002
Resolved
INSTALL METALLIC VALVE ON FUEL STRAINERS. VALVES MUST BE PLUGGED OR CAPPED TO PREVENT LEAKAGE. LEGACY COMPONENT DESC: Filter
Fire Fighting › Fire Hoses
Issued 3 June 2002
Resolved
INSTALL LENGTH OF HOSE LONG ENOUGH TO REACH EACH AREA OF VESSEL (MINIMUM 50 FEET) PRIOR TO CARRIAGE OF PASSENGERS.. LEGACY COMPONENT DESC: Length
Engineering
Issued 12 January 2001
Resolved
PROVIDE MACHINERY GUARDS FOR MAIN PROPULSION ENGINES.
Documentation
Issued 12 January 2001
Resolved
PROVIDE PROOF OF VALID FCC RADIO SAFETY CERTIFICATE. VSLS IS RESTRICTED TONO MORE THAN 1,000 FT FROM SHORE UNTILL REQUIREMENT IS CLEARED.
Lifesaving
Issued 12 January 2001
Resolved
PROVIDE CREW EMERGENCY TRAINING AND EMERGENCY EQUIPMENT LOG BOOK.
Lifesaving
Issued 12 January 2001
Resolved
PROVIDE CLIP FOR RING LIFE BUOY LIGHT LINE.
Lifesaving
Issued 12 January 2001
Resolved
RENEW YELLOW PULL LINE ON EPIRB.
Navigation
Issued 12 January 2001
Resolved
PROVIDE TIDE AND CURRENT TABLES FOR OPERATIONAL AREA.
Fire Fighting
Issued 12 January 2001
Resolved
PROVIDE PROPER VENT CLOSURES FOR ENGINE ROOM VENTS FOR FIXED FIRE FIGHTING SYSTEM.
Lifesaving
Issued 12 January 2001
Resolved
PROVIDE MEANS TO RETRIEVE HELPLESS PERSON FROM WATER.
Lifesaving
Issued 12 January 2001
Resolved
UP-DATE CREW EMERGENCY INSTRUCTIONS FOR RETRIEVAL OF PERSON IN WATER.
Fire Fighting
Issued 26 April 1999
Resolved
CONVERT CURRRENT FIXED FIREFIGHTING SYSTEM TO COMPLY WITH ALARM REQUIREMENTS.
Documentation
Issued 26 April 1999
Resolved
PROVIDE FCC OPERATORS LICENSE.
Lifesaving
Issued 26 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation
Issued 26 April 1999
Resolved
INITIATE: DRILL/TRNG LOG IAW 46 CFR 185.520 AND 185.524; EPIRB MAINTENANCE AND INSPECTION OF LIFESAVING EQUIP LOGS IAW 46 CFR 185 SUBPART G.
Lifesaving
Issued 26 April 1999
Resolved
SCHEDULE U/W MOB AND FIREFIGHTING DRILLS UNDER USCG EVAL.
Documentation
Issued 26 April 1999
Resolved
COMPLY WITH REQUIREMENTS ON DRUG CONSORTIUM AUDIT FORM.
Documentation
Issued 26 April 1999
Resolved
PROVIDE DOCUMENT STICKER FOR 1999.
Documentation
Issued 26 April 1996
Resolved
PROVIDE AN ONE HOUR DRUG AWARENESS TRAINING FOR ALL LICENSED PERSONS.
Navigation
Issued 26 April 1996
Resolved
PROVIDE A BOX FOR FCC RADIO BATTERY.
Engineering
Issued 29 April 1993
Resolved
Renew fuel vent flame screens.
Engineering
Issued 29 April 1993
Resolved
Re-label emergency fuel shutdown.
Navigation
Issued 1 June 1992
Resolved
Replace lens on both NAV lts.
Lifesaving
Issued 1 June 1992
Resolved
STENCIL 10 PFD'S WITH VESSELS NAME.
Documentation
Issued 1 June 1992
Resolved
Provide FCC operators license.
Lifesaving
Issued 1 June 1992
Resolved
Provide 406 MHZ EPIRB or class A EPIRB manufactured after 01OCT88._x001C_
Engineering
Issued 11 December 1990
Resolved
REPLACE SHAFT LOG HOSE CLAMPS.
Construction/Loadline
Issued 11 December 1990
Resolved
FOAM SEAL E/R FWD BHD, PORT LOWER.
Navigation
Issued 11 December 1990
Resolved
RENEW EPIRB BATTERY PRIOR TO CARRYING PASSENGERS.
Electrical
Issued 11 December 1990
Resolved
CRIMP TYPE SPLICES ONLY TO BE USED BILGE PUMP WIRING.
Lifesaving
Issued 11 December 1990
Resolved
REPAIR RING BUOY WATER LIGHT AND PROVIDE 60' LINE ATTACHED TO RING BUOY.
Lifesaving
Issued 11 December 1990
Resolved
REPAIR PORT WATER LIGHT ON LIFEFLOAT AND ATTACH BOTH LIGHTS WITH 18' LINE TO FLOAT.
Construction/Loadline
Issued 11 December 1990
Resolved
INSTALL CAPTIVE CHAIN BOW HATCH.
Construction/Loadline
Issued 11 December 1990
Resolved
REPAIR DAMAGE STERN END OF KEEL.
Electrical
Issued 19 June 1990
Resolved
SUMMIT A SKETCH OF WIRING SYSTEM SHOWING HOW AIR CONDITIONERS ARE CONNECTEDAND WHERE AMMETER IS. SHOW WIRE SIZE AND TYPE CIRCUIT BREAKER SIZE.
Electrical
Issued 2 May 1990
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF S/S GENERATOR.
Lifesaving
Issued 2 May 1990
Resolved
RENEW FLOAT-FREE LINKS ON BOTH LIFEFLOATS.
Engineering
Issued 28 June 1989
Resolved
SEPARATE FUEL SHUT-OFF VALVES FROM FUEL TANK COMPARTMENT.
Navigation
Issued 28 June 1989
Resolved
MARK EPIRB WITH VESSEL'S NAME.
Electrical
Issued 28 June 1989
Resolved
PROVIDE COVER FOR GENERATOR START BATTERY.
Lifesaving
Issued 28 June 1989
Resolved
PROVIDE 60' OF LINE ATTACHED TO RING BUOY.
Documentation
Issued 6 June 1989
Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE.
Documentation
Issued 6 June 1989
Resolved
DRYDOCK DUE 06DEC90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Deck/Cargo
Issued 6 June 1989
Resolved
RENEW WASTED WATER TANK HOSE CLAMPS.
Engineering
Issued 6 June 1989
Resolved
REPAIR LOOSE SHAFT LOG HOSE.
Construction/Loadline
Issued 6 June 1989
Resolved
INSTALL CAPTURE CHAINS ON ALL WEATHER DECK HATCHES.
Engineering
Issued 6 June 1989
Resolved
INSTALL HEAT SHIELD KITS FOR 2 RACOR FUEL FILTERS.
Electrical
Issued 6 June 1989
Resolved
MOUNT THE GENERATOR MUFFLER.
Electrical
Issued 6 June 1989
Resolved
REPAIR GENERATOR MUFFLER INLET HOSE CONNECTION.
Casualty record · 2
20 September 2006Routine · role: Involved in a Marine Casualty · activity 2782799
14 October 2007Routine · role: Involved in a Marine Casualty · activity 3083192
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.