Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 11 May 2026
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2026
Resolved 11 May 2026
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 May 2026
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. The life float had a fracture on the seam. Repair the fracture.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2026
Resolved 3 June 2026
Resolution: Lifefloat was repaired with an [name withheld] type approved repair kit and was repainted with approved brand paint.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 31 May 2025
Resolved
Marine employers must establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who: Occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. The vessel was found employing 01 crewmember onboard that is not part of the chemical testing program established by the marine employer.
46 CFR 16.230 (a)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2025
Resolution: Vessel provided documentation on consortium and crew list found satisfactory to attending marine inspector.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 May 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. Forward compartment hight bile water visual alarm was found inoperable. 46 CFR 182.530.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 23 May 2025
Resolution: LED was disconnected, it was reconnected and tested fully operational.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 May 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Tide tables; and Current tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel was missing tides and current publications. 46 CFR 184.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 23 May 2025
Resolution: Current tables have been provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide an approved first aid kit. 46 CFR 184.710.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 23 May 2025
Resolution: New first aid kit has been provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2025
Resolved
The lights prescribed in these Rules (Subpart C) shall have an intensity as specified in Annex I to these Rules (33 CFR part 84), so as to be visible at the following minimum ranges, in a vessel of less than 12 meters in length: A white, red, green or yellow all-round light, 2 miles. Vessel all around light was found not to be "all around and it has 3 separate LED diodes and two of those were found inoperative. 33CFR83.22(c)(v).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 June 2025
Resolved 23 May 2025
Resolution: A new all around light was provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 May 2024
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instruction. There are two openings one port and one stbd in the forward engine room bulkhead. Make the openings in the forward bulk head of the engine room and around the exhaust vapor tight. Insure no other through hull penetrations are open. 46 CFR 181.420 (a)(b) Code 17.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and they installed new gaskets and locking mechanism.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 May 2024
Resolved
A hatch exposed to the weather must be watertight. Make engine room hatch, and smaller access hatch forward of the main hatch of the engine room water and airtight to prevent the ingress of water and air, and prevent CO fire extinguishing agent to escape engine room compartment if activated. 46 CFR 179.360 Code 17C.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and they installed new gaskets and locking mechanism.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 9 May 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Port and starboard supply ducts (manual dampers) were found not closing properly an airtight seal. 46 CFR 182.465/Code17C.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and they installed new gaskets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 02 adult sized life jackets were missing, vessel is limited to 26 persons. 46 CFR 180.71 (a)/Code 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership, they purchased and put in service new life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 May 2024
Resolved
A vessel on an limited coastwise must carry: Six hand red flare distress signals and six hand orange smoke distress signals approved in accordance with § 160.037 in subchapter Q of this chapter. Vessel is missing 03 oranges distress signals, vessel is limited to a lakes, bays and founds routes until the correct amount of distress signals is on board. 46 CFR 180.68 (a)(1)(2)/Code16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and new distress signals are onboard.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Vessel was found not having complete publications as above-mentioned. 46 CFR 184.420/Code16C.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and all publications are now onboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Visual Led high bilge water alarm was not working in the steering room. 46 CFR 182.530 (a)(1)/Code 16C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and a new ligth was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Engine room submersible bilge pump was found not in compliance with UL approval. 46 CFR 182.520 (e)(1)/Code16C
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 21 May 2024
Resolution: Conducted satisfactory deficiency check with vessel ownership and they installed new bilge pump with accurate UL approval.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2019
Resolved
A vessel must undergo an annual inspection within 3 months before or after each anniversary date. SPV [name withheld] did not complete an annual exam by December 25, 2019, which was 3 months after its anniversary date.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 December 2019
Resolved 9 May 2024
Resolution: Vessel completed COI exam 2024 Activity 7904794.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 December 2019
Resolved
A vessel must undergo a drydock examination every two years. SPV [name withheld] did not complete a drydock exam by its due date of December 31, 2019.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2020
Resolved 9 May 2024
Resolution: Vessel completed a dry dock in YR2024, credit granted MAY2024.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 September 2018
Resolved
07 lifejackets need their retro-reflective tape replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Operator sent in pictures of retro-reflective tape being replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 26 September 2018
Resolved
Vessel needs to properly label location of where child and adult life jackets are stored separately.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2018
Resolution: Operators sent in pictures of proper labeling of lifejacket stowage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 September 2018
Resolved
There are loose wires located behing the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 October 2018
Resolution: General manager sent in photos of loose wires being properly secured.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 26 September 2018
Resolved
Vessel's radio is missing MMSI correct number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 November 2018
Resolution: Received photos from general manager of the correct MMSI number entered into the vessel's radio.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 January 2018
Resolved
Provide valid Certificate of Documentation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2018
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 17 January 2018
Resolved
Provide valid drug and alcohol program enrollment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2018
Documentation › Certificates/Documents › Stability Letter
Issued 17 January 2018
Resolved
Provide onboard and properly post the vessel's stability letter.
Action required: 705 - Other - as specified
Due 23 January 2018
Resolved 17 January 2018
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 17 January 2018
Resolved
Provide servicing documentation for one of the two BII Fire Extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: Vessel rep provided proper servicing documentation for fire extinguishers.
Lifesaving › Lifefloat › Float-free Link
Issued 17 January 2018
Resolved
Provide appropriate size and properly install float free link on the life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: Float free link was installed properly.
Lifesaving › Lifefloat › Serviceable
Issued 17 January 2018
Resolved
Renew or repair lifefloat. Interior netting is torn and hand line rings are deteriorating and/or are broken/breaking.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: Interior netting on life float was repaired.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 January 2018
Resolved
Renew expired lifefloat water light battery.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 26 September 2018
Resolution: Battery was replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 January 2018
Resolved
Re-stencil name of vessel on lifebuoy.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 26 September 2018
Resolution: Name of vessel was clearly labled on lifebuoy.
Lifesaving › Hand Flares › Expired
Issued 17 January 2018
Resolved
Provide proper amount of distress signals.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2018
Resolution: Vessel had proper amount of distress signals on board.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 17 January 2018
Resolved
Properly mark the number and size of lifejacket storage.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 26 September 2018
Resolution: Lifejacket storage was properly labled.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 January 2018
Resolved
Remove water from inside battery boxes.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 26 September 2018
Resolution: Battery boxes were found dry.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 January 2018
Resolved
Clean out fuel tank/sewage compartment.
Action required: 705 - Other - as specified
Due 24 January 2018
Resolved 26 September 2018
Resolution: Compartment found in clean condition.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2018
Resolved
Relocate or raise stern light so that it is visable IAW the navigation rules. Restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 26 September 2018
Resolution: Light was properly installed.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 January 2018
Resolved
Three (03) lifejackets found in unserviceable condition. Limited to carrying no more than 25 persons onboard.
Action required: 705 - Other - as specified
Resolved 26 September 2018
Resolution: Lifejackets were found in proper condition.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 January 2018
Resolved
Properly hang wires in the fuel tank void space.
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 26 September 2018
Resolution: Wires were properly secured in fuel tank void space.
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Service
Issued 18 April 2017
Resolved
Provide annual service to fireboy system. No records onboard of last service record.
46CFR181.420
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2017
Resolved 21 April 2017
Resolution: Annual servicing report provided.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2017
Resolved
Provide 28 adult life jackets. 4 were found to be bad.
46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 21 April 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 18 April 2017
Resolved
Post all pages of the COI, only the first page is posted.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Communications › Radio Communications › VHF Radiotelephone
Issued 18 April 2017
Resolved
Provide Radio Station Authorization. Captain was unable to provide the certificate.
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 4 May 2017
Resolution: [name withheld] e-mailed a picture of the FCC document.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2017
Resolved
Provide approved First Aid Kit. Eyewash and burn cream are expired
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Lifesaving › Hand Flares › Storage
Issued 18 April 2017
Resolved
Provide watertight container for "DISTRESS SIGNALS." The current one leaks and is labeled incorrectly.
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 April 2017
Resolved
Add reflective tape IAW regulations to life jackets. Tape was coming off multiple life jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Lifesaving › Lifebuoys › Stowage
Issued 18 April 2017
Resolved
Provide proper length line for water light on life ring, currently has 8ft line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 April 2017
Resolved
Repair STBD Fire Damper. Gasket damaged allowing air leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 21 April 2017
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 18 April 2017
Resolved
Replace waterlight for life float. Current one is age degraded and not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 21 April 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 April 2017
Resolved
Child size life jackets must be stowed in a location apropriatly marked and seperate.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 21 April 2017
Engineering › Bilge Water Management System › Pump
Issued 18 April 2017
Resolved
Replace (2) bilge pumps with UL rated bilge pumps. FWD compartment and Aft compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 21 April 2017
Lifesaving › Lifefloat › Serviceable
Issued 14 April 2017
Resolved
Replace 14 man life float. Current one is age degraded and not serviceable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 2 May 2017
Resolution: Owner replaced age degraded life float with used serviceable life float.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 July 2016
Resolved
Install pre-engineered fire extinguisher override switch on the operating station according to the manufacturer's instruction.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2016
Resolved 29 July 2016
Resolution: Connected manuafacturer's override switch at the operating station.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 July 2016
Resolved
Fix dead end wiring in engine room and lazarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Dead end wiring was fixed throughout vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 27 July 2016
Resolved
Replace welding cable with Marine Grade Cable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Welding cable was replaced by boat cable throughout vessel.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 July 2016
Resolved
Stow child life jackets separately from adults.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 29 July 2016
Resolution: Placed the child life jackets on a separate net.
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 27 July 2016
Resolved
Fix leaking port shaft bearing/packing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Packing was tightened on drip-less bearing.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 27 July 2016
Resolved
Post emergency instructions specific to vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2016
Resolved 4 August 2016
Resolution: Vessel specific emergency instructions were posted in the vessel.