Documentation record
Registered dimensions (L × B × D)60.7 ft × 20.0 ft × 5.7 ft
Registered tonnagegross 64 / net 43
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTUART, FL, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portATLANTIC HIGHLANDS, NJ
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it64 - Regulatory (Subpart C or D), Gross Ton
43 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 18 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
3 April 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8341388
11 December 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8281696
15 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8062614
11 December 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8045636
12 December 2023
COI Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837867
15 May 2023
In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7688489
12 January 2023
Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7620005
14 December 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7578700
6 December 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7358590
31 March 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166053
15 January 2021
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7125276
22 May 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6960749
13 May 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6689682
17 January 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6611544
11 April 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6389853
24 March 2017
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6110773
12 January 2017
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6069716
7 April 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848939
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 December 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI noticed approximately 35 adult lifejackets deteriorated and unserviceable. Replace all deteriorated lifejackets to the satisfaction of the attending marine inspector. Vsl is restricted to 60 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 April 2026
Resolution: Attended vessel. 38 lifejackets were replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 11 December 2025
Resolved
Each survival craft must be: Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Vsls float free link was missing tag and unable to determine its breaking strength. Replace float free link in accordance with 46 CFR 160.073(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 18 December 2025
Resolution: Vsl provided objective evidence via photograph of weak link that was purchased and placed in service, sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 11 December 2025
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from the weather deck, valve hand broke during testing. Replace valve handle to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 December 2025
Resolved 11 December 2025
Resolution: Valve handle was replaced, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 December 2023
Resolved
(a) All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Bilge suction in Compartment 1 is missing a strainer on the suction end.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 January 2024
Resolved 5 January 2024
Resolution: Strainer re-installed
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 December 2023
Resolved
(a)As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible; Electronic charts not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 January 2024
Resolved 5 January 2024
Resolution: Charts updated.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2023
Resolved
(g) Owners and operators, and personnel serving on the following small vessels engaged exclusively on domestic, near-coastal voyages are ... not subject to further requirements for the purposes of the STCW Convention: (1) Small passenger vessels subject to subchapter T or K of 46 CFR chapter I. E. Medical Emergency. 1. Red Cross certified in first aid and CPR. (Minimum of 50% of required deckhands)
Action required: 10 - Deficiency Rectified
Due 9 January 2024
Resolved 12 December 2023
Resolution: Produced red cross cert's
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 12 December 2023
Resolved
The equipment required for lifefloats and buoyant apparatus must meet the following specifications: (1) Lifeline and pendants. The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Lifeline strap deteriorated on life float identified.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 January 2024
Resolved 5 January 2024
Resolution: Strap replaced with repair.