HUNTER is a 1975 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in March 2026, along with 31 deficiencies — 1 with no resolution recorded —.

Records from 2016 to 2026. Most recent: inspection, 25 March 2026.

Built
1975
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDQ9095
Flag
UNITED STATES
Maury page id
psix-52547

Documentation record

Registered dimensions (L × B × D)53.1 ft × 16.6 ft × 7.1 ft
Registered tonnagegross 43 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderROSE BROTHERS BOAT WORKS · HARKERS ISLAND, NC, UNITED STATES · built 1975
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBROOKLYN, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 28 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it43 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 16

25 March 2026 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8331894
4 March 2026 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319955
15 April 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112375
4 April 2024 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7888376
27 December 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7841733
27 March 2023 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7659951
11 April 2022 Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7425935
23 December 2021 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7371877
6 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161981
27 May 2020 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6964665
11 February 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6906277
9 April 2019 DAPI Audit · Annual Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6658165
27 February 2018 Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363043
25 October 2017 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294808
13 March 2017 DAPI Audit · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6103554
25 February 2016 Administrative Inspection · Annual Inspection · DAPI Audit · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5823997

Deficiency record · 31

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2026 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has lapsed its Drydock and Internal Structural Exam requirement. Prior to carriage of passengers, vessel shall recieve credit Drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2026
Resolution: Dry Dock inspection complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2025 Resolved
"All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment." Bilge pump in forepeak was found inoperable. Repair bilge pump. 46 CFR 182.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2025 Resolved
"Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: 1. Date of the drill and training; and 2. General description of the drill scenario and training topics." Vessel could not find written record of most recent drill. Provide proof of drill log. 46 CFR 185.524
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Investigation after accident
Issued 16 April 2025 No resolution recorded
"Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the [Serious Marine Incident]. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred." Alcohol test kits kept in office. Put test kits on the vessel. 46 CFR 4.06-3
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 April 2025 Resolved
"Each inflatable buoyant apparatus must be equipped in accordance with the manufacturer's approved servicing manual." IBA found with painter line attached to bottom shackle of arrangement. Attach painter line to weak link. 46 CFR 180.175(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 April 2025
Resolution: Reattached painter line
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 4 April 2024 Resolved
MI discovered exposed rotating machinery parts on each MDE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2024
Resolution: Vessel's operator submitted satisfactory photograph of guard around all rotating machinery parts on MDEs in vessel's engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
MI discovered that 02 portable fire extinguishers were on the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2024
Resolution: Vessel's operator submitted satisfactory photograph of each portable fire extinguisher onboard off the deck in a suitable bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 April 2024 Resolved
Vessel's IBA was not stowed in its proper location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2024
Resolution: Vessel installed IBA in its proper location.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 4 April 2024 Resolved
Vessel's engine room was found with 3-4 inches of sitting water. Bilge pump in space was found to work.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2024
Resolution: Vessel submitted satisfactory photograph of engine room with no found sitting water. Deck in engine room appears to be in good condition.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2023 Resolved
Individual power bilge pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Bridge alarm panel labeling did not match the vessels current bilge pump configuration. Relabel bridge panel to indicate correct bilge pumps. 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2023 Resolved
Individual power bilge pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. High level alarm on bridge for lazarette, audible alarm was inoperative. Repair audible alarm.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2023 Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck. Fire extinguishers in crew quarters were not permanently unted. Install correct mounts for fire extinguishers. 46 CFR 181.500(d)
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel installed new fire extinguisher brackets and provided photographic evidence. Cleared Def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2023 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel's life jacket storage is improperly marked for the number of childrens life jackets. Correct numbering to match number of jackets onboard. 46 CFR 185.604(f)
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel relabled life jacket storage to indicate the correct number of life jackets are being stowed. Verrified rectification via photographic evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessel's port and starboard navigation lights have a film of paint or corrosion over the lens. Repair or replace navigation light lens covers. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel cleaned and reinstalled navagation light covers. Verrified rectification via photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 April 2023 Resolved
Each inflatable liferaft required on a vessel by this part must have a capacity of 6 persons or more. Vessel must install liferaft and hydrostatic release. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel reinstalled life raft and hydrostatic release. Verrified rectification via photographic evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2023 Resolved
During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination. STBD shaft seal has excessive leakage. Repair shaft STBD shaft seal. 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2023 Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Clip on floating waterlight was seized. Repair or replace seized clip.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 19 April 2023
Resolution: Vessel provided photographic evidence showing the correct installation of new clip on floating waterlight.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 April 2022 Resolved
Each item of lifesaving equipment must be in serviceable condition. Man-overboard drill maybe required to be conducted under simulated emergency conditions.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: rescue platform was modified to retrieve man overboard from the side of the vessel rather than from the rear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2022 Resolved
Electrical equipment must be maintained to protect from electrical hazard. Exposed electrical wire in FWD cabin port side.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: frayed wire has been taped up and insulated properly
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 11 April 2022 Resolved
Rail Courses must have no open space more than 12 inches in hight. VSL missing lower cable around pilot house port side rail.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: cable on pilothouse railing has been replaced
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 May 2021 Resolved
Pre-engineered fixed fire EXT system must be capable of automatically shutdown of all power ventilation and all engines that draw intake air from within the space. Engines failed to shutdown Cite – 46CFR181.420(a)(3) Action – 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021 Resolved
Provisions must be made for closing all supply ducts, cowls, or scoops for a space protected by fixed fire ext system. Machinery ventilation was missing supply duct covers. Cite – 46CFR182.465(h) Action 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Electrical equipment on vessel must be installed and maintained to protect passengers and crew and vessel from hazards caused by electrical equipment. Vessel installed new batteries and battery charger. Battery continuously charging at 50amps. Cite - 46CFR183.200 (b) Action - 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2021 Resolved
Marine employers shall ensure all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs or alcohol. Alcohol test strips were expired Cite - 46CFR16.240 Action - 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021 Resolved
Abandon ship and man overboard drills shall be logged. No logbook on vessel Cite – 46CFR185.520(f) Action - -16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 May 2021 Resolved
Monthly Epirb test shall be logged. No logbook on vessel Cite 46CFR185.728(c) Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 6 May 2021 Resolved
Sewage overboard discharge must be secured when within 3nm of shore. No method of securing sewage overboard discharge. Cite – 33CFR159.7 Action – 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Cable and wire must be listed by UL as UL Boat or UL Marine Cable. 2 power strips in bunk room Cite – 46CFR183.340(d) Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2021 Resolved
Vessel must have on board a valid FCC Safety Certificate. Certificate not present Cite – 47CFR80.401 Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 May 2021 Resolved
Operation of transmitters of any ship must be performed by person holding MROP. No person able to provide MROP Cite 47CFR80.154 Action – 50c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
Resolution: Received email from o/o of MROP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021 Resolved
Repairs/alterations that affect vessel safety must be approved by OCMI. Provide manufacturer data sheets for LED lights, batteries, and battery charger Cite – 46CFR176.700 Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
Resolution: Cleared.

Ownership record