Records from 1985 to 2026. Most recent: inspection, 25 March 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 69
25 March 2026
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8331894
4 March 2026
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319955
15 April 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112375
4 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7888376
27 December 2023
Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7841733
27 March 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7659951
11 April 2022
Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7425935
23 December 2021
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7371877
6 May 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7161981
27 May 2020
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6964665
11 February 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6906277
9 April 2019
DAPI Audit · Annual Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6658165
27 February 2018
Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6363043
25 October 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6294808
13 March 2017
DAPI Audit · Internal Structural Exam · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6103554
25 February 2016
Administrative Inspection · Annual Inspection · DAPI Audit · Hull Examination · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5823997
10 March 2014
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4821000
14 February 2011
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3944677
18 March 2010
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3700396
17 February 2009
Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3416756
27 March 2008
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3172035
26 February 2008
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3154141
30 March 2007
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2897332
13 March 2006
Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2600129
23 March 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2031047
10 March 2004
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2027635
21 October 2003
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1927833
19 May 2003
Simplified Stability Test
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1827619
1 April 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1772116
5 April 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1603296
16 October 2001
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1074349
12 April 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1061931
21 February 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1058920
7 April 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817217
19 October 1999
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1415273
2 April 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 786980
10 April 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1126748
24 October 1997
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1121891
10 April 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1091428
23 September 1996
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 825640
16 April 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1080110
2 November 1995
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1454269
10 April 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1179240
28 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1420915
30 August 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1398116
20 May 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1169962
3 May 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021253
13 April 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857783
19 April 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1151618
25 February 1993
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1147587
27 July 1992
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1270047
13 May 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261230
15 April 1992
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1267081
6 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269883
3 May 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899703
16 April 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1237816
24 April 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1227450
13 April 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906461
11 April 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1210636
23 March 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1209246
27 May 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198962
13 April 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198961
14 April 1987
Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1012069
27 January 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1314405
18 November 1986
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1326691
11 April 1986
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1307266
25 March 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1305071
23 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982974
17 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981115
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2026
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has lapsed its Drydock and Internal Structural Exam requirement. Prior to carriage of passengers, vessel shall recieve credit Drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2026
Resolution: Dry Dock inspection complete.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 April 2025
Resolved
"All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment." Bilge pump in forepeak was found inoperable. Repair bilge pump.
46 CFR 182.25-1 (OLD T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2025
Resolved
"Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: 1. Date of the drill and training; and 2. General description of the drill scenario and training topics." Vessel could not find written record of most recent drill. Provide proof of drill log.
46 CFR 185.524
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 April 2025
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Investigation after accident
Issued 16 April 2025
No resolution recorded
"Alcohol testing must be conducted on each individual engaged or employed on board the vessel who is directly involved in the [Serious Marine Incident]. The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred." Alcohol test kits kept in office. Put test kits on the vessel.
46 CFR 4.06-3
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 April 2025
Resolved
"Each inflatable buoyant apparatus must be equipped in
accordance with the manufacturer's approved servicing manual." IBA found with painter line attached to bottom shackle of arrangement. Attach painter line to weak link.
46 CFR 180.175(c)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 16 April 2025
Resolution: Reattached painter line
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 4 April 2024
Resolved
MI discovered exposed rotating machinery parts on each MDE.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2024
Resolution: Vessel's operator submitted satisfactory photograph of guard around all rotating machinery parts on MDEs in vessel's engine room.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024
Resolved
MI discovered that 02 portable fire extinguishers were on the deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 April 2024
Resolution: Vessel's operator submitted satisfactory photograph of each portable fire extinguisher onboard off the deck in a suitable bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 4 April 2024
Resolved
Vessel's IBA was not stowed in its proper location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2024
Resolution: Vessel installed IBA in its proper location.
09 - Working and Living Conditions › 091 - Living Conditions › Drainage
Issued 4 April 2024
Resolved
Vessel's engine room was found with 3-4 inches of sitting water. Bilge pump in space was found to work.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 April 2024
Resolution: Vessel submitted satisfactory photograph of engine room with no found sitting water. Deck in engine room appears to be in good condition.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2023
Resolved
Individual power bilge pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation.
Bridge alarm panel labeling did not match the vessels current bilge pump configuration. Relabel bridge panel to indicate correct bilge pumps. 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 17 April 2023
Resolved
Individual power bilge pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation.
High level alarm on bridge for lazarette, audible alarm was inoperative. Repair audible alarm.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 April 2023
Resolved
The frame or support of each semi-portable fire extinguisher permitted by paragraph (a) of this section must be welded or otherwise permanently attached to a bulkhead or deck.
Fire extinguishers in crew quarters were not permanently unted. Install correct mounts for fire extinguishers. 46 CFR 181.500(d)
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel installed new fire extinguisher brackets and provided photographic evidence. Cleared Def.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 April 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets.
Vessel's life jacket storage is improperly marked for the number of childrens life jackets. Correct numbering to match number of jackets onboard. 46 CFR 185.604(f)
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel relabled life jacket storage to indicate the correct number of life jackets are being stowed. Verrified rectification via photographic evidence.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 April 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Vessel's port and starboard navigation lights have a film of paint or corrosion over the lens. Repair or replace navigation light lens covers. 46 CFR 183.420
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel cleaned and reinstalled navagation light covers. Verrified rectification via photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 April 2023
Resolved
Each inflatable liferaft required on a vessel by this part must have a capacity of 6 persons or more.
Vessel must install liferaft and hydrostatic release. 46 CFR 180.200.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 18 April 2023
Resolution: Vessel reinstalled life raft and hydrostatic release. Verrified rectification via photographic evidence.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2023
Resolved
During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
STBD shaft seal has excessive leakage. Repair shaft STBD shaft seal. 46 CFR 176.610.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 20 April 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2023
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip.
Clip on floating waterlight was seized. Repair or replace seized clip.
Action required: 705 - Other - as specified
Due 20 April 2023
Resolved 19 April 2023
Resolution: Vessel provided photographic evidence showing the correct installation of new clip on floating waterlight.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 11 April 2022
Resolved
Each item of lifesaving equipment must be in serviceable condition. Man-overboard drill maybe required to be conducted under simulated emergency conditions.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: rescue platform was modified to retrieve man overboard from the side of the vessel rather than from the rear.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 April 2022
Resolved
Electrical equipment must be maintained to protect from electrical hazard. Exposed electrical wire in FWD cabin port side.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: frayed wire has been taped up and insulated properly
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 11 April 2022
Resolved
Rail Courses must have no open space more than 12 inches in hight. VSL missing lower cable around pilot house port side rail.
Action required: 705 - Other - as specified
Resolved 20 April 2022
Resolution: cable on pilothouse railing has been replaced
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 May 2021
Resolved
Pre-engineered fixed fire EXT system must be capable of automatically shutdown of all power ventilation and all engines that draw intake air from within the space.
Engines failed to shutdown
Cite – 46CFR181.420(a)(3)
Action – 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2021
Resolved
Provisions must be made for closing all supply ducts, cowls, or scoops for a space protected by fixed fire ext system.
Machinery ventilation was missing supply duct covers.
Cite – 46CFR182.465(h)
Action 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021
Resolved
Electrical equipment on vessel must be installed and maintained to protect passengers and crew and vessel from hazards caused by electrical equipment.
Vessel installed new batteries and battery charger. Battery continuously charging at 50amps.
Cite - 46CFR183.200 (b)
Action - 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2021
Resolved
Marine employers shall ensure all persons directly involved in a serious marine incident are chemically tested for evidence of dangerous drugs or alcohol.
Alcohol test strips were expired
Cite - 46CFR16.240
Action - 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2021
Resolved
Abandon ship and man overboard drills shall be logged.
No logbook on vessel
Cite – 46CFR185.520(f)
Action - -16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 6 May 2021
Resolved
Monthly Epirb test shall be logged.
No logbook on vessel
Cite 46CFR185.728(c)
Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 6 May 2021
Resolved
Sewage overboard discharge must be secured when within 3nm of shore.
No method of securing sewage overboard discharge.
Cite – 33CFR159.7
Action – 701c
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021
Resolved
Cable and wire must be listed by UL as UL Boat or UL Marine Cable.
2 power strips in bunk room
Cite – 46CFR183.340(d)
Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 May 2021
Resolved
Vessel must have on board a valid FCC Safety Certificate.
Certificate not present
Cite – 47CFR80.401
Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2021
Resolved 24 May 2021
Resolution: Operator rectified deficiency
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 6 May 2021
Resolved
Operation of transmitters of any ship must be performed by person holding MROP.
No person able to provide MROP
Cite 47CFR80.154
Action – 50c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
Resolution: Received email from o/o of MROP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2021
Resolved
Repairs/alterations that affect vessel safety must be approved by OCMI.
Provide manufacturer data sheets for LED lights, batteries, and battery charger
Cite – 46CFR176.700
Action – 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2021
Resolution: Cleared.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 February 2009
Resolved
Repair broken handrail stanchion port side just forward of the cabin and two broken welds on the starboard side handrail just forward of the cabin. Both items are to be repaired or renewed by 15APR09.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 7 April 2009
Resolution: port stanchion repaired by over sizing bolt holes and using larger hardware. Starboard cracked stanchions were repaired with sleeves.
Construction/Loadline › Hull › Side Shell
Issued 26 February 2008
Resolved
Various amounts of angel hair noted in the engine room, mostly on the port and stbd side shell.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 March 2008
Resolved 27 March 2008
Resolution: Angel hair noticed was only superficial and did not affect the structure of the vessel, all sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 26 February 2008
Resolved
Owner needs to conduct u/w check ride prior to carrying passengers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 27 July 2008
Resolution: U/w check ride conducted, all sat.
Construction/Loadline › Hull › Side Shell
Issued 13 March 2006
Resolved
Remove angel hair from affected areas in engine room and preserve as necessary.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 4 April 2006
Resolution: Attended vessel. Angel hair has been scraped and areas treated with white vinegar.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 March 2006
Resolved
Renew engine shaft enclosure in aft engine room bulkhead, starboard side.
Action required: 705 - Other - as specified
Due 13 April 2006
Resolved 4 April 2006
Resolution: Attended vessel and examined satisfactory installation of new enclosure.
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Repair leaking rudder posts
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 March 2004
Resolved 29 March 2004
Resolution: Proceeded underway. Rudder posts sat.
Construction/Loadline › Hull
Issued 23 March 2004
Resolved
Repair leak in #2 compartment. Second and Third bay.
Due 23 March 2004
Resolved 29 March 2004
Resolution: Vessel hauled out of water. Replaced oakum on 18 inch section below starboard spray rail. Proceeded underway to inspection compartment. No leaks observed. All sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 10 March 2004
Resolved
Service all fire fighting extinguishers. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2004
Resolved 23 March 2004
Resolution: Serviced all fire fighting extinguishers.
Construction/Loadline › Penetrations
Issued 10 March 2004
Resolved
Install lanyards on all exterior hatches.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2004
Resolved 23 March 2004
Resolution: Installed lanyards.
Engineering
Issued 10 March 2004
Resolved
Install caps/plugs on elbow's for engine room vents.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2004
Resolved 23 March 2004
Resolution: Installed caps for engine room vents.
Operations/Management
Issued 21 October 2003
Resolved
Vessel granted a one-year credit drydock due to fastner removal due by October 31, 2004. O/O opted for one year credit dry dock in lieu of fastner removal this dry dock inspection.
Due 31 October 2004
Resolved 10 March 2004
Resolution: Conducted 24-month credit dy-dock this date
Construction/Loadline › Hull
Issued 21 October 2003
Resolved
Conduct fastener removal for Coast Guard inspection.
Due 31 October 2004
Resolved 10 March 2004
Resolution: Conducted fastener inspection this date. All sat.
Construction/Loadline › Penetrations
Issued 21 October 2003
Resolved
Remove/Replace valve and handle on overboard for well box.
Due 31 October 2004
Resolved 10 March 2004
Resolution: Replace gate valve with new ball valve. Inspected sat.
Construction/Loadline › Structures
Issued 21 October 2003
Resolved
Replace both overhead beams above port and stdb MDE's
Due 31 October 2004
Resolved 10 March 2004
Resolution: Replaced both overhead beams located above MDE''s
Engineering
Issued 21 October 2003
Resolved
Scrape and preserve all angel hair in engine room.
Due 31 October 2004
Resolved 10 March 2004
Resolution: Completed.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 21 October 2003
Resolved
Replace both MDE's intake gate valves. LEGACY COMPONENT DESC: Valve
Due 31 October 2004
Resolved 10 March 2004
Resolution: Installed 2 new ball valves for both MDE''s. Valves inspected sat.
Engineering
Issued 21 October 2003
Resolved
Cap dead-end valve on transom.
Due 31 October 2004
Resolved 10 March 2004
Resolution: Installed cap on dead-end valve on transom.
Lifesaving
Issued 1 April 2003
Resolved
Prior to carrying passengers, proof operation of bilge alarm in # 1 compartment and fire pump.
Due 1 April 2003
Resolved 2 April 2003
Resolution: Observed visual and audible bilge alarm in # 1 comparment and operation of fire pump. All tests sat.
Engineering
Issued 1 April 2003
Resolved
Repair wet exhaust bracket on starboard side in lazarette.
Due 21 April 2003
Resolved 2 April 2003
Resolution: Repaired wet exhaust bracket.
Engineering
Issued 1 April 2003
Resolved
Repair leaking rudder port rudder post.
Due 21 April 2003
Resolved 2 April 2003
Resolution: Tightened port rudder post packing. All sat.
Navigation
Issued 1 April 2003
Resolved
Update charts for vessel operational area.
Due 21 April 2003
Resolved 2 April 2003
Resolution: Purchased all new charts for area.
Stability
Issued 1 April 2003
Resolved
Repair in-kind, forward bulkhead, lower portion in engine room on port side.
Due 21 April 2003
Resolved 2 April 2003
Resolution: Repaired lower portion on forward engine room bulkhead.
Lifesaving
Issued 5 April 2002
Resolved
Replace retro-tape on 3 adult and 1 child life jacket.
Due 11 April 2002
Resolved 11 April 2002
Resolution: Purchased 3 new adult and 1 child life jacket.
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 April 2002
Resolved
Remount electrical cable in second compartment for anchoring system.
Due 11 April 2002
Resolved 11 April 2002
Resolution: Remounted electrical cable.
Construction/Loadline › Penetrations
Issued 5 April 2002
Resolved
Seal engine room bulkhead penterations.
Due 11 April 2002
Resolved 11 April 2002
Resolution: Sealed all engine room bulkhead pentrations.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 April 2002
Resolved
Re-splice line on ring bouy.
Due 11 April 2002
Resolved 11 April 2002
Resolution: Respliced line on ring bouy.
Construction/Loadline
Issued 12 April 2001
Resolved
Prove proper operation of high water bilge alarms.
Condition: Unknown
Due 20 April 2001
Resolved 27 April 2001
Fire Fighting
Issued 12 April 2001
Resolved
Raise location of pre-engineered fixed fire fighting bottle to a point as high as practicable in the engine room.
Condition: Unknown
Due 15 May 2001
Resolved 27 April 2001
Engineering
Issued 12 April 2001
Resolved
Replace elbo fitting on generator cooling water exhaust.
Condition: Unknown
Due 20 April 2001
Resolved 27 April 2001
Lifesaving
Issued 10 April 1997
Resolved
VESSEL MUST OBTAIN APPROVED FIRST AID KIT IAW 46 CFR 184.710.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Lifesaving
Issued 10 April 1997
Resolved
VSL LIFEFLOAT MUST BE RE-INSTALLED AND MARKED WITH VESSELS NAME PRIOR TO VESSEL SAILING.
Condition: Unknown
Due 30 April 1997
Resolved 11 April 1997
Construction/Loadline
Issued 2 November 1995
Resolved
MAKE VSL AVAILABLE FOR UNDERWAY EXAM DUE TO REPAIRED PLANKS FOUND DURING CREDIT DRYDOCK.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
REPAIR TWO CRACKED PLANKS #33 AND #34 DOWN FROM THE GUNWALE ON THE STARBOARD SIDE 18" AFT OF THE STEM.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Construction/Loadline
Issued 2 November 1995
Resolved
REPAIR FOUR CRACKED PLANKS, 49" FROM THE STEM ON THE STARBOARD SIDE, 14" TO22" DOWN FROM THE GUNWALE.
Condition: Unknown
Due 15 November 1995
Resolved 15 November 1995
Navigation
Issued 10 April 1995
Resolved
PROVIDE DOCUMENTATION OF CREW TRAINING PER EMPLOYEE ASSISTANCE PROGRAM OF CHEMICAL DRUG TESTING REGULATIONS (46 CFR 16).
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 10 April 1995
Resolved
PROVIDE MAGNETIC COMPASS DEVIATION TABLE.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 10 April 1995
Resolved
VESSEL RESTRICTED TO 7 PERSONS UNTIL 23 ADULT AND 4 CHILD LIFEJACKETS PROVIDED.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Electrical
Issued 10 April 1995
Resolved
REPAIR ELECTRICAL GROUND STRAP ON FORWARD BULKHEAD OF ENGINE COMPARTMENT.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 10 April 1995
Resolved
MARK LIFEJACKET STOWAGE.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Lifesaving
Issued 10 April 1995
Resolved
DEMONSTRATE EMERGENCY DRILLS (FIRE, MAN OVERBOARD).
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Construction/Loadline
Issued 10 April 1995
Resolved
REPLACE PORT AFT MAIN DECK HATCH RETAINING LINE.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Documentation
Issued 10 April 1995
Resolved
PROVIDE RECORDKEEPING LOG PER MARPOL ANNEX V GARBAGE REGULATIONS.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Fire Fighting
Issued 10 April 1995
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 10 April 1995
Resolved
PROVIDE SSB RADIO PRIOR TO OPERATING ON OCEANS ROUTE.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Navigation
Issued 13 April 1994
Resolved
PROVIDE CURRENT TIDAL CURRENT INFORMATION FOR THE ROUTE PERMITTED BY THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Navigation
Issued 13 April 1994
Resolved
PROVIDE CURRENT NAVIGATION CHARTS FOR THE ROUTE PERMITTED ON THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Lifesaving
Issued 13 April 1994
Resolved
PRIOR TO CARRYING MORE THAN 44 ADULT PASSENGERS, PROVIDE 4 ADDITIONAL USCG APPROVED TYPE I LIFEJACKETS.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Lifesaving
Issued 13 May 1992
Resolved
PROVIDE CLASS "A" EPIRB MFG AFTER 01OCT88 OR UPGRADE TO MEET FCC REGULATIONS. VESSEL RESTRICTED TO COASTWISE ROUTE NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL EPIRB PROVIDED._x001C_ _x001C_
Condition: Unknown
Due 13 May 1992
Resolved 13 May 1992
Navigation
Issued 15 April 1992
Resolved
PROVIDE CLASS "A" EPIRB MFG AFTER 01OCT88 OR UPGRADED TO MEET FCC REGULATIONS. VESSEL RESTRICTED TO COASTWISE ROUTE NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL EPIRB PROVIDED.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Fire Fighting
Issued 15 April 1992
Resolved
PROVIDE ONE B-I PORTABLE FIRE EXTINGUISHER FOR WHEELHOUSE PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Navigation
Issued 15 April 1992
Resolved
PROVIDE FOLLOWING UPDATED/CORRECTED PUBLICATIONS AND CHARTS: CHARTS FOR VESSEL'S OPERATING AREA DESCRIBED ON THE CERTIFICATE OF INSPECTION PRIOR TOCARRYING PASSENGERS.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Lifesaving
Issued 15 April 1992
Resolved
TOTAL PERSONS ONBOARD RESTRICTED TO 32 UNTIL 18 TYPE I ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 15 April 1992
Resolved 15 April 1992
Electrical
Issued 16 April 1991
Resolved
PROVIDE A OPERATIONAL TEST OF (2) RPM GAUGES FOR THE MAIN DIESEL ENGINES_x001C_ PRESENTLY INOPERABLE.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Lifesaving
Issued 16 April 1991
Resolved
PROVIDE TWO ADULT PFD'S WHERE MISSING. UNTIL THIS REQUIREMENT IS CLEARED THE VESSEL IS LIMITED TO 48 TOTAL PERSONS.
Condition: Unknown
Due 16 April 1991
Resolved 16 April 1991
Electrical
Issued 24 April 1990
Resolved
DEMONSTRATE OPERATION OF THE SERVICE GENERATOR AFTER REPAIRS. SUBMIT PLANSFOR APPROVAL IF GENERATOR IS REPLACED WITH ONE OF GREATER OUTPUT.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Navigation
Issued 11 April 1989
Resolved
PROVIDE REPLACEMENT LENSE COVERS FOR THE PORT AND STARBOARD RUNNIG LIGHTS, AND THE MAST LIGHT.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Accommodation/Occupational Safety
Issued 11 April 1989
Resolved
PROVIDE NATURAL LOW VENTILATION TO THE ENGINE COMPARTMENT AND THE FUEL TANKCOMPARTMENT WHERE MISSING.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989
Resolved
PROVIDE ONE (1) ADULT PFD.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Engineering
Issued 18 November 1986
Resolved
REPAIRS VESSEL'S ENGINE SO AS TO ELIMINATE ALL OIL LEAKING INTO THE BILGE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Engineering
Issued 18 November 1986
Resolved
MAKE ENGINE ROOM BILGES FREE OF OIL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Engineering
Issued 18 November 1986
Resolved
PROVIDE DOUBLE CLAMPS ON ALL HOSES FOR THROUGH HULL FITTINGS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986
Resolved
INSTALL DOGS ON CENTERLINE MANHOLE COVER FOR AFT VOID. (46CFR171.124)
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986
Resolved
FREE UP AND MAKE OPERATIONAL ALL DOGS ON STARBOARD SIDE AFT VOID.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986
Resolved
INSTALL DOG ON FORWARD VOID HATCH. (46CFR171.124)
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Electrical
Issued 25 March 1986
Resolved
PROPERLY SECURE FORWARD STARBOARD BATTERY BOX AND BATTERIES.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Construction/Loadline
Issued 25 March 1986
Resolved
REPAIR HOLES TO COLLISION BULKHEAD.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Construction/Loadline
Issued 25 March 1986
Resolved
REMOVE WATER FROM FORWARD BILGE IN #2 COMPARTMENT AND CLEAR DRAINAGE TO BILGE PUMP.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Electrical
Issued 25 March 1986
Resolved
REPAIR AND PROVE PROPER OPERATION OF BILGE PUMP IN #2 COMPARTMENT.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986
Electrical
Issued 25 March 1986
Resolved
RENEW VALVE HANDLE TO GENERATOR EXHAUST/COOLING OVERBOARD VALVE.
Condition: Unknown
Due 25 March 1986
Resolved 25 March 1986