Records from 1985 to 2026. Most recent: inspection, 20 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
20 April 2026
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8350882
8 May 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8112636
15 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7904765
12 May 2023
Internal Structural Exam · Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7680366
7 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7445143
19 April 2021
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7178515
4 May 2020
Construction Oversight
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6947829
9 April 2020
Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6923912
19 April 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6653538
19 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6726637
3 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6372446
4 April 2017
Internal Structural Exam · DAPI Audit · Drydock Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6083309
2 May 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5866997
15 May 2014
Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4842898
6 June 2012
Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4335625
26 March 2009
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3439957
25 March 2008
Deficiency Check · Simplified Stability Test · Re-Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3171202
6 March 2007
Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2882549
21 April 2006
Hull Examination · Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2630529
12 April 2005
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2331847
30 April 2003
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1780602
25 April 2002
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1494452
23 April 2001
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1412274
25 April 2000
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1429337
20 May 1998
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1126936
23 May 1997
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 781954
23 April 1996
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 840618
20 April 1995
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1357385
20 April 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1359886
30 April 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1407174
30 March 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1454021
20 March 1992
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1322658
1 April 1991
Hull Examination · COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1231443
11 May 1990
Drydock Extension
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 918592
12 April 1990
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1231944
17 April 1989
Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1031377
19 April 1988
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1032111
26 October 1987
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1328502
28 May 1986
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 984912
15 April 1986
Re-Inspection · Credit Drydock
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1306609
12 April 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 985912
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 8 May 2025
Resolved
Equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Seal the fwd engine room bulkhead penetrations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2025
Resolved 28 May 2025
Resolution: Received objective evidence of penetrations sealed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2024
Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. No closure devices were provided for the 3 ER ventilation ducts.
OLD T 46 CFR 181.20-35
Action required: 10 - Deficiency Rectified
Due 15 May 2024
Resolved 15 May 2024
Resolution: Closure stuffings provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2023
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit medicine expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 15 May 2023
Resolution: Unexpired medicine and a tourniquet have been placed in first aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2023
Resolved
Each ring life buoy must be marked with Type II retroreflective material. No retro tape on the ring life buoy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 15 May 2023
Resolution: Retroreflective tape has been placed on the ring life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2023
Resolved
Remote fuel shutoff must be marked in clearly legible letters at least 1-in high with the purpose of the valve. No markings to indicate fuel shutoff.
Action required: 10 - Deficiency Rectified
Resolved 12 May 2023
Resolution: Emergency fuel shutoff was properly marked.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 June 2022
Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. Portable extinguishers shall be installed on a hanger or bracket intended for such purpose. Vessel fire extinguishers are not mounted.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 7 June 2022
Resolution: Fire extinguishers have been mounted to the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 June 2022
Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operations. Vessel waterlight does not work. Vessel is limited to daylight operations until light is working.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 June 2022
Resolved 15 June 2022
Resolution: Waterlight battery has been replaced and is working properly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 April 2019
Resolved
Engineroom hatch not weather tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 29 April 2019
Resolution: New hatch gasket installed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 April 2019
Resolved
Fuel shut off at tank not accessible in an emergency.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 May 2019
Resolved 29 April 2019
Resolution: Access established for emergency fuel shut off at fuel tank.
Documentation › Certificates/Documents › Stability Letter
Issued 27 March 2008
Resolved
Complete a simplified stability test.
Action required: 705 - Other - as specified
Due 28 April 2008
Resolved 2 May 2008
Resolution: Vessel underwent stab test.
Documentation › Certificates/Documents › Stability Letter
Issued 26 March 2008
Resolved
Provide and post copy of current stability letter.
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Stab letter issued.
Documentation › Certificates/Documents › FCC SSL
Issued 26 March 2008
Resolved
Provide copy of FCC safety certificate for marine radio.
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Noted FCC safety cert in place from Cay electronics.
Communications › Radio Communications › VHF Radiotelephone
Issued 26 March 2008
Resolved
Prove all licensed masters have marine radio operator permits (FCC).
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Noted licenses for all masters.
Construction/Loadline › Penetrations › Pipe Flange
Issued 26 March 2008
Resolved
Minimize or completely stop leak at packing gland for rudder.
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Rudder packing noted to be leak free.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2008
Resolved
Update medical kit.
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Med kit noted to be current.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 March 2008
Resolved
Prove magnetic compass light properly operates.
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 2 May 2008
Resolution: Mag compass light noted to be properly operating.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 April 2006
Resolved
Properly repair the MDE R/W suction line ensure all R/W system components are in satisfactory condition and to conduct an underway operational test of the engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 April 2006
Resolved 27 April 2006
Lifesaving › Lifebuoys › Serviceable
Issued 21 April 2006
Resolved
Replace deteriorated life ring.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 13 April 2005
Resolved
Prior to operating launch, operators must complete pre-employment screening for drug program.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 19 May 2005
Resolution: Operator provided evidence of negative pre-employment drug test results.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 April 2005
Resolved
Provide Drug/Alcohol Program verification from Newport Alliance. Renewed paperwork, but has not received documentation verifying renewal at time of inspection.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Consortium membership verification provided.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 12 April 2005
Resolved
Secure child life preservers in separate area or bag and clearly mark the new location.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Child lifejackets were stowed in a clearly marked location separate from adult lifejackets. Stowage location was under the seat in the forward part of the vessel.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 April 2005
Resolved
Repair ventilation flap and make compartment airtight (engine room).
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Observed ventilation flap working properly. Vessel operator had re-connected controlling wire.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 12 April 2005
Resolved
SEcure rope on anchor chain.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Observed rope attaches to anchor chain.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 April 2005
Resolved
Label all areas/boxes where life jackets are located with numbers.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Lifejacket locations were labeled with number of life jackets inside.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 12 April 2005
Resolved
Provide two working flashlights.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Observed two working flashlights on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2005
Resolved
Secure hanging bonding wire to rudder.
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 13 May 2005
Resolution: Observed bonding wire connected to rudder.
Lifesaving › Lifejacket/PFD (General)
Issued 30 April 2003
Resolved
MARK VESSELS NAME ON THROWABLE RING BUOY. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 30 April 2003
Resolution: STENCILED PRIOR TO COMPLETING INSPECTION.
Engineering › Fuel Oil Service System › Valve
Issued 30 April 2003
Resolved
MARK LOCATION OF EMERGENCY SHUT OFF FUEL VALVE ON DECK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 30 April 2003
Resolution: CORRECTED PRIOR TO COMPLETION OF INSPECTION.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 April 2003
Resolved
REPLACED (5) TYPE II PFD'S, STRAPES AND RETRO TAPE NOT IN SERVICABLE CONDITION.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2003
Resolved 30 April 2003
Resolution: PFD''S REMOVED AND REPLACED WITH NEW, PFD''S STENCILED WITH VESSEL NAME ON THE SPOT.
Documentation
Issued 25 April 2002
Resolved
PROVIDE DOCUMENTATION FOR DRUG/ALCOHOL AUDIT
Due 13 May 2002
Resolved 15 May 2002
Documentation
Issued 25 April 2002
Resolved
PROVIDE EMERGENCY INSTRUCTIONS AS PER 46CFR185.510
Due 13 May 2002
Resolved 15 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 25 April 2002
Resolved
LABEL STORAGE AREA FOR CHILD LIFEJACKETS
Due 13 May 2002
Resolved 15 May 2002
Lifesaving › Lifebuoys
Issued 25 April 2002
Resolved
LABEL RING BUOY WITH NAME OF VESSEL, APPLY RETRO-REFLECTIVE TAPE, AND PROVIDE A WATERLIGHT WITH 3' OF LINE AND A NON-CORROSIVE CLIP.
Condition: Improper/Lack of Maintenance
Due 13 May 2002
Resolved 15 May 2002
Lifesaving
Issued 25 April 2002
Resolved
PROVIDE DONNING PLACARD FOR LIFEJACKETS
Due 13 May 2002
Resolved 15 May 2002
Engineering
Issued 25 April 2002
Resolved
PROVIDE METAL BOWL UNDER FUEL STRAINER
Due 13 May 2002
Resolved 15 May 2002
Unknown
Issued 23 April 2001
Resolved
Provide vessel with required documents and logs.
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Unknown
Issued 23 April 2001
Resolved
Restricrted from carrying passengers without operators enrolled in drug testing program.
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Lifesaving
Issued 15 April 1986
Resolved
PROVIDE ONE (1) ADDITIONAL ADULT PFD ON BOARD.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Documentation
Issued 15 April 1986
Resolved
PROVIDE AND POST ON BOARD THE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986