Records from 1985 to 2023. Most recent: inspection, 17 January 2023.
Inspection history · 89
17 January 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7622861
4 March 2022
Deficiency Check · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7405770
24 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7205917
30 October 2020
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7085937
19 October 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7079888
2 October 2020
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7070418
2 October 2020
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7074295
18 March 2020
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6928496
12 November 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6931444
29 October 2019
Deficiency Check · Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6844908
27 October 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6855146
24 September 2019
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6866212
5 June 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6680369
27 March 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6354447
6 February 2018
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6315945
6 March 2017
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6084302
14 June 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5903374
3 February 2016
Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5803243
20 May 2014
DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4838422
26 July 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4395589
26 January 2012
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4220024
12 February 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3679190
2 December 2009
DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3645931
3 December 2008
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3373781
11 September 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3322555
22 August 2008
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3306020
16 July 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3270006
15 May 2008
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3207614
5 April 2008
Re-Inspection · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3160360
14 March 2008
Construction Oversight · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3357007
13 July 2007
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2997439
3 April 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2898358
10 July 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2708245
5 July 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2671377
27 June 2006
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2690919
17 August 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2467998
5 May 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2337775
17 June 2004
Annual Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2106778
27 April 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2055466
31 March 2004
Drydock Extension · Internal Structural Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2034685
17 August 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1891829
30 May 2003
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1860605
21 May 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1798227
7 October 2002
Examination of Repairs · Damage Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1684123
19 September 2002
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1677715
11 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1607829
28 March 2002
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1598582
18 March 2002
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1619989
30 January 2002
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1482818
7 September 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1418767
23 December 1999
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1452601
23 July 1999
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369277
14 April 1998
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 789907
2 March 1998
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1455562
7 November 1997
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1120383
4 August 1997
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 119911
3 May 1997
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1386047
3 May 1996
MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1402311
19 May 1995
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1183369
2 May 1995
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1174936
3 April 1995
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363234
10 May 1994
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1385279
9 December 1993
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1158141
24 November 1993
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 845636
3 June 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 80216
30 May 1993
Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1452959
29 May 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 59567
18 May 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1452960
30 April 1993
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1354304
14 April 1993
Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1147997
8 December 1992
Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1393879
18 May 1992
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 944536
12 August 1991
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 933889
25 April 1991
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 905594
2 October 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 908609
14 August 1990
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1221143
17 May 1990
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1212875
15 August 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1042044
8 May 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1344891
27 April 1989
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1346274
20 May 1988
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1044386
15 April 1988
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1338194
17 April 1987
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1320718
17 November 1986
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1327690
10 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015741
13 August 1986
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 994550
23 May 1986
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 989047
12 May 1986
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1293914
30 April 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 983306
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 March 2022
Resolved
Crop and renew hard inset on stbd bow.
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: After further investigation the inset was found to be purely cosmetic (only impacted filler material used during production to achive desired hull shape) and does not impact hull/watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 March 2022
Resolved
Skydeck port and stbd handrail and decking deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: Handrail and decking properly repaired by boat yard.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 March 2022
Resolved
2nd deck port and stbd amidship supports deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 14 March 2023
Resolution: This item was not verified to be repaired or resolved by a [name withheld] administratively cleared and entered as special note.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 4 March 2022
Resolved
Stbd aft entry point handrail and deck deteriorated.
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: Handrail and deck attachment fitting repaired by yard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 4 March 2022
Resolved
Port spiral aft glass broken.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 14 March 2023
Resolution: This item was not verified to be repaired or resolved by a [name withheld] administratively cleared and entered as special note.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 4 March 2022
Resolved
Skydeck entry point to bridal room wood step rotted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: Bridal room entry wooden step repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 March 2022
Resolved
Identify tank with missing cap under bridal room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: Tank removed from service.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 March 2022
Resolved
Remove fire hazard/load in E/R bilge, make ready for inspection.
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: O/O removed fire hazard/load from engine room and had bilges professionally cleaned.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 4 March 2022
Resolved
Repair or replace watertight hatch for bow thruster space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 14 March 2023
Resolution: This item was not verified to be repaired or resolved by a [name withheld] administratively cleared and entered as special note.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › UMS - Ship
Issued 4 March 2022
Resolved
Remove bag around bilge pick up in the bow thruster room.
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 15 March 2022
Resolution: Bag removed from bilge.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 4 March 2022
Resolved
Service Co2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 March 2022
Resolved 14 March 2023
Resolution: This item was not verified to be repaired or resolved by a [name withheld] administratively cleared and entered as special note.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 May 2021
Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the [name withheld] discovered galley fire extinguisher to be missing approved bracket.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 24 June 2021
Resolution: Received photo of installed fire extinguisher with bracket.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 May 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following tests and inspections of the hull structure and its appurtenances: (1) Examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck.
MI discovered pin hole leak under STBD MDE Exhaust hull penetration allowing water ingress. Provide repair proposal for plan review approval.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 22 June 2021
Resolved 4 August 2021
Resolution: Inspected clad weld repair to pin hole. Repair appeared satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 May 2021
Resolved
All electrical installations shall be to the satisfaction of the [name withheld] on the bridge, MI discovered multiple dead end cables, missing light fixture in overhead, and wires not properly supported around the operators station. DC volt meters missing labels.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 4 August 2021
Resolution: Dead end wires removed, renewed overhead lighting fixture, DC Volt meter replaced and all wire runs properly supported.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 May 2021
Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector.
Abandon Ship and Fire Drill shall be conducted in the presence of the attending MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2021
Resolved 4 August 2021
Resolution: Conducted satisfactory tabletop fire and abandon ship drills.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 May 2021
Resolved
Inop Port MDE J/W Temperature and L/O PSI Gauges.
46 CFR 182.15-2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 June 2021
Resolved 4 August 2021
Resolution: Replaced Port MDE J/W Temp and L/O PSI Gauges. OPS Tested SAT.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 October 2020
Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. The port side damper/closure does not work. Repair closure and prove proper operation to an attending marine inspector. 46CFR181.20-35
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Vessel repaired closure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2020
Resolved
A vessel more than 65 feet in length must carry a minimum of three lifebuoys of not less than 24 inches in diameter. Each ring buoy on a vessel must be approved in accordance with 46 CFR 160.050; be readily accessible; be stowed in a way that it can be readily cast loose. Life ring on the upper deck is heavily deteriorated. Replace life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: Life Ring replaced with brand new one with retro and name of vessle stenciled on.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2020
Resolved
At least one ring buoy must be fitted with a lifeline. Each lifeline on a ring buoy must: be buoyant; be of at least 60 feet in length; be non kinking; have a diameter of at least 5/16 inch; have a breaking strength of at least 1,124 pounds; and be of a dark color synthetic or be resistant to deterioration from UV light. Lifeline is heavily deteriorated. Replace lifeline.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 19 October 2020
Resolution: Vessel replaced lifeline.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 October 2020
Resolved
The discharge ends of vent pipes shall be fitted with removeable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. The vent pipes for the fuel tank do not have a flame screens or flame arresters installed. Install a 30 x 30 mesh flame screen on the vent pipes for the fuel tank. 46CFR182.20-35
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 2 November 2020
Resolution: Installed 30 x 30 mesh flame screen.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
At each initial and subsequent inspection for certification, reinspection, and at every other vessel inspection the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. A light fixture in the engine room is missing a cover. Install/replace lighting fixture cover. 46CFR176.25-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: New light fixture installed with cover.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces. Penetrations in the engine room bulkhead are not filled allowing vapors to enter other spaces. Fill penetrations/holes in the engine room bulkhead. 46CFR177.405
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: Hole in bulkhead was filled with a bolt washer and nut tightened down.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 October 2020
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent content and instructions. The first aid kit is not approved and some of the contents are expired. Place approved, unexpired first aid kit onboard. 46CFR184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: Replaced first aid kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 October 2020
Resolved
Bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. The bilge foot in the lower accomodation space is cracked and corroded. Replace broke bilge foot. 46CFR80.1005
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: Replaced bilge foot with new piping and bilge suction strainer.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2020
Resolved
The bridge to bridge radiotelephone station will be inspected on vessels subject to the regular inspections pursuant to the requirements of the Communications Act. Vessel does not have a valid bridge to bridge certificate. Provide valid bridge to bridge certificate. 47CFR80.1005
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 21 October 2020
Resolution: Vessel has valid bridge to bridge certificate.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2020
Resolved
A power driven vessel underway shall exhibit: a masthead light forward. Vessel's masthead light is inoperable. Repair/replace masthead light. 33CFR83.23
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 30 October 2020
Resolution: Replaced bulb and mast head light is lit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 October 2020
Resolved
Every vessel subject to the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician once every 5 years. Radiotelephony Certificate is expired. Provide valid Radiotelephony Certificate. 47CFR80.903
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2020
Resolved 21 October 2020
Resolution: Vessel has valid radiotelephony certificate.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 October 2020
Resolved
Vessel shall be inspected for compliance with the standard required by Subchapter T. For items not covered, inspections shall be IAW standard acceptable by the OCMI as good marine practice. MI found the starboard side outter engine shaft seal to be leaking. Make proper repairs to the shaft seal. Vessel required to visually inspect the packing glad/shaft seal, shaft and associated components prior to getting underway, upon return and before departing the vessel for the day and make log entry.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 October 2020
Resolved 16 October 2020
Resolution: Vessel replaced packing and lubriacted packing glad. Observed operation while underway, all satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 October 2020
Resolved
Propulsion machinery must be suitable in type and design for proulsion requirements of the hull in which it is installed and capable of operating at a constant marine load under such requirements without exceeding its designed limitations. Vessel expereinced a loss of propulsion and had to get towed back to berth while underway with passengers. Vessel must prove proper operation of the engines prior to the carraige of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 October 2020
Resolved 3 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and vessel from electrical hazards. Replace burnt cable over port MDE.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2019
Resolved 1 November 2019
Resolution: Burnt electrical cable was replaced over the port Main Diesel Engine.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019
Resolved
Internal combustion engine exhaust, boiler and galley uptakes and similar sources of ignition must be kept clear of and suitably insulated from combustable material. Replace oil soaked lagging on STBD MDE.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2019
Resolved 1 November 2019
Resolution: The oil soaked lagging on starboard Main Diesel Engine was replaced.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019
Resolved
Internal combustion engine exhaust, boiler and galley uptakes and similar sources of ignition must be kept clear of and suitably insulated from combustable material. All exhaust piping in vincinity of Port MDE need to have proper exhaust lagging.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2019
Resolved 1 November 2019
Resolution: Proper exhaust lagging was fixed onto and in vicinity of the port Main Diesel Engine exhaust.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 June 2019
Resolved
An adult life jacket must be provided for each person carried onboard. Life jacket count came out to be 156 total out of 185 as per the COI. Provide 29 life jackets to bring the total adult life jacket count to 185 as per COI.
Action required: 705 - Other - as specified
Resolved 5 June 2019
Resolution: Provided 29 Life jacket to bring total to 185 as per COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2019
Resolved
Observed unsafe practices, fire hazard and other hazardous situation. Port inboard MDE was leaking oit from the tubo onto the exhaust causing a possible fire hazard. Make repairs to MDE to stop oil leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2019
Resolution: Deficiency rectified to the satisfaction of the attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2019
Resolved
Observed unsafe practicews, firwe hazard and other hazardous situation. Port outboard MDE was excessively leaking coolant from the exhaust manifold. Make repairs to MDE to stop coolant leak.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2019
Resolution: Replaced exhaust manifold gasket. Leak stopped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2019
Resolved
Protection from hot piping. Exhaust lagging was missing throught the engine room. Replace missing exhaust lagging.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2019
Resolution: Replaced missing lagging.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 June 2019
Resolved
Rails must be installed on all decks accesible to passengers and crew. Port quarter removable railing is damaged and no longer fits in it support tubes. Make permanent repairs to port quarter railing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2019
Resolution: Permanent repair to railing complete.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 June 2019
Resolved
Watertight bulkheads. Starboard forward engine room watertight bulkhead has open cable holes. Make bulkhead watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 June 2019
Resolution: Plugged holes whith white 5200.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 5 June 2019
Resolved
Sanitary inspection. Excessive grease was found on a junction box behind galley range hood causing a fire hazard. Remove grease from junction box and area behind the range hood.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Area behind range hood was free of grease.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 June 2019
Resolved
Opening in the shell of the vessel. All shaft packing were leaking excessively. Make adjustments to packing to slow shaft packing leakage down to a managable drip.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2019
Resolution: Replaced all shaft packing. Leaking was to an acceptable drip.
Construction/Loadline › Structures › Ventilators
Issued 7 March 2018
Resolved
Vent boxes on outboard sides of vessel show wastage. Make watertight.
Action required: 705 - Other - as specified
Due 7 April 2018
Resolved 15 April 2020
Resolution: Renewed see narrative for details.
Fire Fighting › Grease Extraction Hood › General
Issued 6 February 2018
Resolved
Prove proper installation and operation of galley hood wet chemical extinguishing system IAW manufactures manual. To include shutdowns required by NFPA 17A. Prior to operation of any protected galley equipment.
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Proper operation of gally hood demonstrated.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 March 2017
Resolved
Provide 10 additional lifejackets to replace those that were deterioriated. The number of passengers permitted is reduced to 140 until this item is corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 6 March 2017
Resolution: Corrected during inspection.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 6 March 2017
Resolved
Provide 2 additional child lifejackets to replace those that were deterioriated. The number of passengers less than 90 pounds is limited to the number of child lifejackets carried.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 6 March 2017
Resolution: Corrected during inspection.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 3 February 2016
Resolved
Provide operable grey water system. The grey water holding tank was altered so that it was discharging through the vent, the submersible pump had failed and dumped aprox. 150 gallons of grey water in the bilge.
Condition: Improper Installation
Due 7 March 2016
Resolved 3 February 2016
Resolution: Vessel crew reconfigured installation of grey water system back to original design.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 May 2014
Resolved
Replace 45 adult size lifejackets.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 1 June 2014
Resolution: Vessel purchased new lifejackets meeting the number required on board.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 May 2014
Resolved
Cap pipe in forward sewage tank.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 22 May 2014
Resolution: Vessel captain provided evidence of proper repairs.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 May 2014
Resolved
Lock overboard handle for sewage discharge.
Action required: 705 - Other - as specified
Due 20 June 2014
Resolved 21 May 2014
Resolution: Owner removed handle for overboard on the spot making it impossible to open.
Engineering › Bilge Water Management System › Pump
Issued 26 January 2012
Resolved
Provide proof of operation of the bilge pumping system.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Resolution: Operator proved proper operation of the bilge pumping system.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 26 January 2012
Resolved
Provide plans for the vessel sewage system and prove operational test of the system.
Action required: 705 - Other - as specified
Due 24 February 2012
Resolved 24 February 2012
Resolution: Provided plans for vessel sewage system and proved proper operational test of the system satisfactorily.
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008
Resolved
Replace fwd bow starboard side wasted metal, Approx 7' by 5' area
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Area of metal was replace as new
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 15 May 2008
Resolved
Replace port inboard prop
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Prop was renewed
Construction/Loadline › Hull › Hull Plating
Issued 15 May 2008
Resolved
Prepare bow truster room plating for inspection, grind area. If needed prepare and paint area afterwards.
Action required: 705 - Other - as specified
Due 15 June 2008
Resolved 26 May 2009
Resolution: Bow thuster compartment plating has been ground and painted.
Construction/Loadline › Structures › Ventilators
Issued 15 May 2008
Resolved
Weld holes in force ventilation in the engine room
Action required: 705 - Other - as specified
Resolved 17 June 2008
Resolution: Area was fire caulked. Area is still in question due to no vent closures.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 May 2008
Resolved
Replace main windows, 4 port fwd, and one starboard fwd.
Action required: 705 - Other - as specified
Resolved 22 August 2008
Resolution: Replaced 4 windows, 4 port fwd, and one stbd.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 July 2007
Resolved
Provide USCG approved B-II 10 lb (minimum) fire extinguisher permanently mounted in the galley.
Action required: 705 - Other - as specified
Due 13 August 2007
Resolved 13 August 2007
Resolution: Mounted.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 July 2007
Resolved
Provide stowage segregation for child/adult lifejackets, in accordance with 46 CFR 180.78 (a) 5
Action required: 705 - Other - as specified
Due 13 August 2007
Resolved 13 August 2007
Resolution: Completed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 13 July 2007
Resolved
Excell oil and water throughout the engine room bilge.
Action required: 705 - Other - as specified
Due 13 July 2007
Resolved 13 July 2007
Resolution: Bilges cleaned.
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2006
Resolved
Provide signage for lower watt light bulbs in all 4 heads.
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 11 August 2006
Resolution: Signage provided for lower watt light bulbs in all 4 heads
Electrical › Lighting (service) › Lighting Fixture
Issued 10 July 2006
Resolved
Provide shields for 2 lights in passageway outside of heads to prevent excessive heat.
Action required: 705 - Other - as specified
Due 11 August 2006
Resolved 11 August 2006
Resolution: Shields provided for 2 lights in passageway outside of heads.
Construction/Loadline › Hull › Side Shell
Issued 7 July 2006
Resolved
Make permanent repairs to hole in side shell and wasted window opening (4th window) on starboard side of vessel.
Action required: 705 - Other - as specified
Due 31 January 2007
Resolved 3 April 2007
Resolution: Repaired.
Construction/Loadline › Penetrations › Pipe Flange
Issued 7 July 2006
Resolved
Provide stuffing tubes and make watertight the penetrations for Christmas light wiring in lazarette bulkheads. Also provide one line electrical diagram of Christmas light system for approval.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 9 August 2006
Resolution: Properly sealed penetration in hull. No stuffing tubes and electrical diagram of Christmas light system required.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 7 July 2006
Resolved
Seal hole in collision bulkhead near deck, port side.
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 9 August 2006
Resolution: Sealed hole in collision bulkhead near deck, port side.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 July 2006
Resolved
Provide enclosures for wiring connections made behind bulkhead for lights serving heads (4).
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 9 August 2006
Resolution: Provided enclosures for wiring connections made behind bulkhead for lights serving heads (4).
Engineering › Thrusters › Piping
Issued 7 July 2006
Resolved
Provide systems drawings for approval on bow thruster installation. Must be completed before system can be used.
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 24 October 2008
Resolution: Completed plan review, oversight of installation and operational testing.
Fire Fighting › Fire Pumps › Capacity
Issued 5 July 2006
Resolved
Fire pump could not deliver sufficent water pressure.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2006
Resolved 7 July 2006
Resolution: New fire pump installed and tested. All satisfactory.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 5 July 2006
Resolved
CO2 actuation cable assembly
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2006
Resolved 7 July 2006
Resolution: Repaired Engine Room CO2 activation cable system to provide proper operation.
Engineering › Bilge Water Management System › Not Installed
Issued 5 July 2006
Resolved
Bilge alarm float switch in MSD space inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2006
Resolved 6 July 2006
Resolution: Bilge float repaired.
Fire Fighting › Grease Extraction Hood › General
Issued 5 July 2006
Resolved
Range Guard out of service inspection perdicity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 7 July 2006
Resolution: Galley Range Guard properly serviced.
Fire Fighting › Structural - B Class Divisions › Main Galleys
Issued 5 July 2006
Resolved
Provide B-15 behind cooking appliances in galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 7 July 2006
Resolution: Area within 30" of cooking areas is of A-0 construction.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 5 July 2006
Resolved
Mount/Install grills, stoves, ovens, dishwasher and fryer to prevent movement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 9 August 2006
Resolution: Mounted grills, stoves, ovens, dishwasher and fryer to prevent movement.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 5 July 2006
Resolved
Remove accumulated grease from behind cooking appliances.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 9 August 2006
Resolution: Removed accumulated grease from behind cooking appliances.
Fire Fighting › Grease Extraction Hood › General
Issued 5 July 2006
Resolved
Provide proper fire suppression for fryer.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 7 July 2006
Resolution: Serviced range system.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 5 July 2006
Resolved
Remove improperly installed electrical shore tie connection.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 9 August 2006
Resolution: Removed improperly installed electrical shore tie connection.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 5 July 2006
Resolved
Provide draft marks.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 14 July 2006
Resolution: Painted draft marks.
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 5 July 2006
Resolved
Renew wasted anchor line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 9 August 2006
Resolution: Renewed wasted anchor line.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 5 July 2006
Resolved
Provide air cleaner to stbd MDE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 August 2006
Resolved 14 August 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 July 2006
Resolved
Provide protective guard to air compressor belt/pulley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 9 August 2006
Resolution: Protective guard to air compressor belt/pulley installed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 July 2006
Resolved
Provide handle and securing device to emergency exit glass door.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 August 2006
Resolved 9 August 2006
Resolution: Handle and securing device to emergency exit glass door installed.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 July 2006
Resolved
Secure handrail to stairway to second deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 14 July 2006
Resolution: Secured handrail.
Communications › Internal Communications System › Sound-powered Telephone
Issued 5 July 2006
Resolved
Provide proper installation and operation of public addrerss system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2006
Resolved 9 August 2006
Resolution: Provided proper installation and operation of public address system.
Electrical › Electric Generation Source (service) › Switch
Issued 5 July 2006
Resolved
Properly mount light switch in galley.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 9 August 2006
Resolution: Light switch in galley mounted.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 5 July 2006
Resolved
Provide secure mounting for dishwasher.
Condition: Improper Installation
Due 6 August 2006
Resolved 9 August 2006
Resolution: Dishwasher mounted and secure.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 July 2006
Resolved
Blank off open holes in electrical box in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 9 August 2006
Resolution: Holes in electrical box in engine room blanked off.
Electrical › Electrical Distribution System (service) › Switch
Issued 5 July 2006
Resolved
Properly mount public address system controls in A/C space and on bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 July 2006
Resolved 9 August 2006
Resolution: Properly mounted public address system controls in A/C space and on bridge.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 5 July 2006
Resolved
Provide protection from exposure/water to dishwater motor and electrical connections.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 August 2006
Resolved 9 August 2006
Resolution: Dishwasher motor and electrical connections are mounted as per the manufacture and used as intended.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2006
Resolved
Provide gauging report for 10' x 10' area of bottom plating below wing void opening in starboard head.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 27 June 2006
Resolution: Provided audio gaugings.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2006
Resolved
Provide gauging report of under body of vessel below heads. Extend gauging until consistent readings of .187" or greater are attained.
Action required: 705 - Other - as specified
Due 10 July 2006
Resolved 10 July 2006
Resolution: Provided gauging report.
Construction/Loadline › Hull › Bottom Plating
Issued 27 June 2006
Resolved
Provide permanent repair to existing areas with >25% wastage and any such areas identified by additional gauging reports.
Action required: 705 - Other - as specified
Due 14 July 2006
Resolved 13 July 2006
Resolution: Permanent repairs made.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 27 June 2006
Resolved
Provide means to shield wall and ceiling coverings from heat being produced by lights in heads (4) and passageway lights (2) outside of heads.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 9 August 2006
Resolution: Lower watt light bulb installed to prevent excessive heat by lights in heads (4). Passageway lights (2) not cleared. Additional deficiency issued.
Construction/Loadline › Hull › Side Shell
Issued 27 June 2006
Resolved
Make side shell plating around 4th window on starboard side available for inspection by removing window.
Action required: 705 - Other - as specified
Due 27 July 2006
Resolved 7 July 2006
Resolution: Cleared and reissued in combination with other repair.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 May 2005
Resolved
The firefighting on board the vessel had had not been serviced and dates on fixed firefighting/semi-portables were expired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 5 May 2005
Resolution: Marine Fire Protection came out and serviced the fixed firefighting and semi portables.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 5 May 2005
Resolved
Repair/replace high water bilge alarm in engine compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 June 2005
Resolved 5 May 2005
Resolution: Replaced high water bilge alarm in engine compartment.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 May 2005
Resolved
Label emergency exit from engine room on outside of hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 17 August 2005
Resolution: Labeled emergency exit from engine room on outside of hatch.
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 5 May 2005
Resolved
Permanently install missing electrical receptacle cover on bridge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 17 August 2005
Resolution: Permanently installed missing electrical cover on bridge.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 5 May 2005
Resolved
Provide a Station Bill for vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 June 2005
Resolved 17 August 2005
Resolution: Provided Station Bill.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 June 2004
Resolved
Replace three children's life jackets and two adult life jackets in poor condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 17 June 2004
Resolution: Went out and purchased the two adult life jackets and three children life jackets during inpsection.
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 17 June 2004
Resolved
Clean grease from galley ventilation hoods.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 25 June 2004
Resolution: Cleaned.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 17 June 2004
Resolved
Label electrical panel in engine room.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: Labeled electrical panel in engine room.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 17 June 2004
Resolved
On bridge: Properly label all used bilge alarm indicators and repair bilge alarm in forward void.
Due 24 June 2004
Resolved 25 June 2004
Resolution: Completed satisfactorily.
Documentation › Certificates/Documents › FCC SSL
Issued 17 June 2004
Resolved
Provide/renew an updated Safety Radio Telephony Certificate.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 26 June 2004
Resolution: Faxed copy of new certificate.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 June 2004
Resolved
Post new COI under glass.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: Posted new COI.
Fire Fighting › Fire Hydrants › Location/Position
Issued 17 June 2004
Resolved
Remove tables blocking CO2 bottles in the Lazarette.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: corrected on the spot.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 17 June 2004
Resolved
Emergency exit in engine room is blocked and needs to be clear.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: Cleared emergency exit in engine room of obstructions.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 17 June 2004
Resolved
Mount extinguisher in bracket.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: Mounted extinguisher into bracket.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 June 2004
Resolved
Remove household extension cord above batteries in engine room.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 17 June 2004
Resolution: Removed household extension cord above batteries in engine room.
Fire Fighting › Remote Fuel Shutoff › General
Issued 17 June 2004
Resolved
Fix emergency fuel shut off valves for engine room.
Condition: Improper/Lack of Maintenance
Due 17 June 2004
Resolved 17 June 2004
Resolution: Fixed emergency fuel shut off valves in engine room.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 June 2004
Resolved
Install a battery box cover in engine room on starboard battery bank.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 25 June 2004
Resolution: Completed satisfactorily.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 June 2004
Resolved
Permanently install missing electrical receptacle covers in bathrooms.
Condition: Improper/Lack of Maintenance
Due 24 June 2004
Resolved 25 June 2004
Resolution: Completed satisfactorily
Construction/Loadline › Hull › Bottom Plating
Issued 27 April 2004
Resolved
Starboard holding tank leaking through bottom hull plating. Required operator to crop and renew steel plate on bottom hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2004
Resolved 25 June 2004
Resolution: Hull plating repaired satisfactorily.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 April 2004
Resolved
Noticed several lighting fixtures broken. Required operator to replace all broken globe lights in lazerette and fore peak area of vessel.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 30 April 2004
Resolution: Broken lighting fixtures replaced as required.
Engineering › Steering Gear System
Issued 31 March 2004
Resolved
Make aft compartment available for insp in way of rudder and steering gear weld repairs. LEGACY COMPONENT DESC: Rudder Stock
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 29 April 2004
Resolution: Weld repairs to rudder post completed and tested satisfactory.
Engineering › Bilge Water Management System
Issued 31 March 2004
Resolved
Make available for inspection rusted bilge piping in MSD compartment. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 29 April 2004
Resolution: Rusted bilge piping in MSD compartment removed.
Construction/Loadline › Hull
Issued 31 March 2004
Resolved
Make fwd compartment dry and free of sludge and rust for thorough inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 29 April 2004
Resolution: All rust scale removed. Primer used to coat all previously rusted areas to prevent further rusting.
Construction/Loadline › Penetrations
Issued 31 March 2004
Resolved
Repair crack in rudder post near bottom hull plating.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 29 April 2004
Resolution: Crack repaired in bottom hull plating and tested using high pressure hose.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 31 March 2004
Resolved
Properly mount CO2 portable fire ext in galley. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 27 April 2004
Resolution: CO2 portable fire extinguisher properly mounted in galley
Electrical › Electrical Distribution System (service)
Issued 8 May 2003
Resolved
Provide approved electrical drawings for all equipment in the galley. Do not use galley for cooking until approval letter is provided. LEGACY COMPONENT DESC: Plan Approval
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 30 May 2003
Resolution: Recieved approved plans.
Documentation › Logs/Records
Issued 8 May 2003
Resolved
Provide service report for galley range fire suppression system. Do not use galley for cooking until this discrepancy is cleared. LEGACY COMPONENT DESC: Installed Galley Firefighting
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 8 May 2003
Resolution: Invoice provided.
Engineering › Compressed Air System (control) › Valve
Issued 8 May 2003
Resolved
Repair faulty relief valve on pneumatic control system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 17 June 2004
Resolution: Repaired faulty relief valve on phuematic control system.
Electrical › Electric Generation Source (service)
Issued 8 May 2003
Resolved
Provide covers for all battery boxes in engineroom. LEGACY COMPONENT DESC: Engineroom Batteries
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 30 May 2003
Resolution: Found sat
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 8 May 2003
Resolved
Properly mount bracket for portable CO2 extinguisher in the galley. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 17 June 2004
Resolution: Properly mounted bracket for portable CO2 exinguisher in the galley.
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 May 2003
Resolved
Conduct and log man overboard and fire drills IAW 46 CFR 185.524. LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2004
Resolution: Vessel is now conducting and logging man overboard and fire drills.
Documentation › Markings/Placards › Capacity Marking
Issued 8 May 2003
Resolved
Move instruction placard from inside STBD PFD locker to an area visible by passengers. LEGACY COMPONENT DESC: PFD donning instructions
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 17 June 2004
Resolution: Removed STBD PFD placard to an area visible for the passengers.
Engineering › Steering Gear System › Rudder Stock
Issued 7 October 2002
Resolved
Repair the steering gear. A repair proposal must be approved prior to commencing repairs. A verbal repair proposal accepted by the attending marine inspector is acceptable.
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 17 June 2004
Resolution: Repaired the steering gear.
Construction/Loadline › Hull › Bottom Plating
Issued 7 October 2002
Resolved
Repair crack in bottom hull plating in way of the rudder posts. A repair proposal must be approved prior to commencing repairs. A verbal repair proposal accepted by the attending marine inspector is acceptable.
Action required: 705 - Other - as specified
Due 18 October 2002
Resolved 17 June 2004
Resolution: Repaired crack in bottom hull plating in way of the rudder posts.
Lifesaving
Issued 7 September 2000
Resolved
Provide rescue boat in accordance with 46 CFR 117.210 to the satisfaction of the attending Marine Inspector. To be completed prior to carrying passengers for hire.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 September 2000
Resolved 7 March 2002
Accommodation/Occupational Safety
Issued 23 December 1999
Resolved
REPLACE SECURING TIES FOR MAIN DECK DODGERS. SECURING TIES PARTED WITH MINIMAL IMPACT AND DOES NOT MEET REQUIREMENTS IAW 46CFR177.900
Condition: Unknown
Due 3 January 2000
Resolved 3 January 2000
Documentation
Issued 23 July 1999
Resolved
OBTAIN AND POST STABILITY LETTER DATED 17MAY93 FROM MSC PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Accommodation/Occupational Safety
Issued 23 July 1999
Resolved
PROVE PROPER OPERATION OF TYPE II MSD OR CAPACITY MEETS REQUIREMENTS FOR TYPE III MSD IAW 33 CFR 159 PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 July 1999
Resolved 2 September 1999
Documentation
Issued 23 July 1999
Resolved
PROVIDE LABEL FOR 01 PASSENGER DECK LIMITING PASSENGERS AS PER VSL STABILITY LETTER PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 24 July 1999
Resolved 19 August 1999
Documentation
Issued 23 July 1999
Resolved
PROVIDE EMERGENCY EVACUATION PLAN IAW 36 CFR 116.520 PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Documentation
Issued 23 July 1999
Resolved
PROVIDE PROOF ENROLLED IN A DRUG AND ALCOHOL TESTING PROGRAM PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Unknown
Issued 23 July 1999
Resolved
PROVIDE RECORD OF CREW TRAINING PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Lifesaving
Issued 23 July 1999
Resolved
PROVIDE PASSENGER SAFETY ORIENTATION PRESENTATION PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Fire Fighting
Issued 23 July 1999
Resolved
COMPLETE FIRE AND MOB DRILLS PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Lifesaving
Issued 23 July 1999
Resolved
PROVIDE 2X50 PERSON TBA'S WITH PROOF OF SERVICE REPORT PRIOR TO CARRIAGE OFPASSENGERS FOR HIRE.
Condition: Unknown
Due 24 July 1999
Resolved 30 July 1999
Documentation
Issued 23 July 1999
Resolved
PROVIDE RECORDS SHOWING MIN REQUIRED FIRST AID/CPR TRAINIG FOR CREW PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Navigation
Issued 2 March 1998
Resolved
Correct location of stern light so it is visible throughout the required arc. To be corrected NLT 14APR98.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Lifesaving
Issued 2 May 1995
Resolved
CONDUCT DRILLS IN ACCORDANCE WITH 46 CFR 185.25-5 AND 46 CFR 185.25-10 TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR TO BE COMPLETED NO LATERTHAN 20 MAY 95.
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Electrical
Issued 10 May 1994
Resolved
MARK ALL EMERGENCY LIGHTING FIXTURES WITH RED INDICATORS.
Condition: Unknown
Due 20 May 1994
Resolved 7 September 1994
Engineering
Issued 10 May 1994
Resolved
LAG EXHAUST MANIFOLDS TO EXHAUST UPTAKES/RISERS.
Condition: Unknown
Due 1 June 1994
Resolved 7 September 1994
Documentation
Issued 10 May 1994
Resolved
PROVIDE/POST WRITTEN WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 20 May 1994
Resolved 7 September 1994
Electrical
Issued 10 May 1994
Resolved
PROPERLY BLOCK/STOW STARTING BATTERIES STBD SIDE OF ENG RM.
Condition: Unknown
Due 20 May 1994
Resolved 7 September 1994
Construction/Loadline
Issued 30 May 1993
Resolved
VEE OUT WELD IN FRACTURED AREA, DRILL STOP, AND REWELD THE SIX INCH DAMAGEDPLATE AREA IN THE HULL ON THE STARBOARD SIDE IN THE LUGGAGE HOLD FORWARD. PERFORM A NDT TEST ON THE WELD REPAIR. THE NDT TEST TO BE WITNESSED BY A CG INSPECTOR.
Condition: Unknown
Due 3 June 1993
Resolved 25 June 1993
Documentation
Issued 30 April 1993
Resolved
VESSEL SHALL NOT CARRY PASSENGERS UNTIL A NEW STABILITY LETTER HAS BEEN PROVIDED.
Condition: Unknown
Due 15 June 1993
Resolved 15 June 1993
Documentation
Issued 12 August 1991
Resolved
PROVIDE LETTER OF DESIGNATION FOR SENIOR DECKHAND, TO [name withheld], WA.
Condition: Unknown
Due 31 August 1991
Resolved 31 August 1991
Documentation
Issued 25 April 1991
Resolved
PROVIDE VALID FCC SAFETY RADIOTELEPHONY CERTIFICATE WITH PROPER CALL SIGN FOR VESSEL.
Condition: Unknown
Due 25 April 1991
Resolved 25 April 1991
Construction/Loadline
Issued 14 August 1990
Resolved
CONDUCT DRY SEARCH AT THE END OF EACH VOYAGE IN BOTH COMPARTMENTS WHERE TEMPORARY REPAIRS EXISTED AND LOG IN THE SHIPS LOG BOOK.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Construction/Loadline
Issued 14 August 1990
Resolved
REMOVE TEMPORARY REPAIR LOCATED STARBOARD SIDE FORWARD OF BULKHD NO.6, APPROXAMENTELY 1FT UP FROM THE SHIP'S KEEL AND MAKE IT PERMANENT REPAIR.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Construction/Loadline
Issued 14 August 1990
Resolved
REMOVE TEMPORARY REPAIR LOCATED AT FRAMES 7 AND 8 PORTSIDE BELOW THE WATER LINE AND MAKE IT PERMANENT REPAIR.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Accommodation/Occupational Safety
Issued 8 May 1989
Resolved
REMOVE CRITERION MILLS INC."HAMPTON CARPET COLOR #4601, ROLL #22581, AB" THIS CARPET DOSE NOT MEET USCG STANDARDS FOR FLAMMABILITY TEST OF 0.81 WATTS/SQ. CM. FOR CRITICAL RADIANT FLUX. THIS CARPET IS 0.34 WATTS/SQ. CM. NEW CARPET MUST MEET USCG SPECS BEFORE INSTALLATION.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Unknown
Issued 27 April 1989
Resolved
PROVIDE DOCUMENTATION ON NEW INSTALATION OF SHIPS SERVICE AIR RECIEVERS ANDSHOW PROPER OPERATION OF UNIT AND RELIEF VALVES PRIOR TO 12 MAY 1989 TO THESATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Electrical
Issued 27 April 1989
Resolved
INSTALL PERMANENT ELECTRICAL SUPPLY TO RESCUE BOAT DAVIT FOR OPERATION OF ELECTRIC WINCH IN ACCORDANCE WITH 46 CFR SUBCHAPTER T PRIOR TO THE CARRIAGEOF PASSENGERS OR 26 MAY 89 TO THE SATISFACTION OF THE ATTENDING C.G. MARINEINSPECTOR.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Documentation
Issued 27 April 1989
Resolved
MASTER TO PRESENT VESSEL DOCUMENT TO C.G. MARINE INSPECTOR PRIOR TO 12MAY89WHILE INSPECTOR ON BOARD VESSEL.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Accommodation/Occupational Safety
Issued 27 April 1989
Resolved
PROVIDE DOCUMENTATION STATING ACCEPTABILITY OF NEWLY INSTALLED CARPET PRIORTO 12 MAY 1989 TO THE SATISFATION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Accommodation/Occupational Safety
Issued 27 April 1989
Resolved
PROVIDE VERIFICATION OF OPERATION, AS CERTIFIED, OF THE MARINE SANITATION DEVICE PRIOR TO 12 MAY 1989 TO THE SATISFACTION OF THE ATTENDING C.G. MARINE INSPECTOR.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Electrical
Issued 15 April 1988
Resolved
REPLACE BATTERY OR PROVE OPERATION OF EMERGENCY LIGHTING IN UPPER CABIN DECK.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Navigation
Issued 15 April 1988
Resolved
REPLACE STERN LIGHT.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Fire Fighting
Issued 15 April 1988
Resolved
SERVICE FIXED CO2 FIRE PROTECTION SYSTEM FOR ENGINE ROOM.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Lifesaving
Issued 15 April 1988
Resolved
LIFERAFTS TO BE PLACED ON BOARD THE VESSEL PRIOR TO CARRYING PASSENGERS ON BOARD AFTER ANNUAL INSPECTION.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 17 April 1987
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL TRIPS AND VERSPEED TRIPS FOR BOTH AUXILIARY GENERATORS
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Construction/Loadline
Issued 17 April 1987
Resolved
MAKE WATERTIGHT WITH CONTINUOUS WELD BULKHEAD #6
Condition: Unknown
Due 17 April 1987
Resolved 17 April 1987
Engineering
Issued 23 May 1986
Resolved
TWO AIR RECEIVERS ON BOARD FOR MAIN PROPULSION CONTROL AIR NEED TO HAVE A HYDROSTATIC TEST
Condition: Unknown
Due 23 May 1986
Resolved 23 May 1986
Electrical
Issued 12 May 1986
Resolved
PROVIDE PROPER INSTALLATION OF WIRING TO GALLEY INTERCOM STATION.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Engineering
Issued 12 May 1986
Resolved
PROVIDE AND INSTALL GUARDS ON FLYWHEELS FOR #'S 2,3 AND 4 MAIN ENGINS
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Engineering
Issued 12 May 1986
Resolved
PROVE PROPER OPERATION OF WHEELHOUSE ALARM SYSTEM TO #4 MAINE ENGINE.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Lifesaving
Issued 12 May 1986
Resolved
PROVIDE CG APPROVED LIGHT TO RING BUOY.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986
Fire Fighting
Issued 12 May 1986
Resolved
PROVE PROPER OPERATION OF FIRE/BILGE PUMP ON #1 MAIN ENGINE.
Condition: Unknown
Due 12 May 1986
Resolved 12 May 1986