Records from 1984 to 1994. Most recent: inspection, 17 May 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
17 May 1994
Administrative
Administrative · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1422365
21 May 1993
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1134654
14 May 1992
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 957194
24 May 1991
COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1229405
17 May 1990
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 903442
26 May 1989
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1347637
8 May 1989
Hull Examination
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1206948
23 May 1988
COI Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1353139
1 April 1988
Administrative
Administrative · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 993052
12 May 1987
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1023078
16 May 1986
Deficiency Check
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 993728
8 May 1986
Re-Inspection
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1297261
22 May 1985
Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 984473
22 March 1985
Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1290037
28 September 1984
Type not recorded
No type recorded · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 975214
Engineering
Issued 21 May 1993
Resolved
Clean flame screens in both port and starboard fuel tank vents as required by 46CFR182.15-35(d) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Remark the first aid kit in the passenger cabin prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Navigation
Issued 21 May 1993
Resolved
Prove the operation of the masthead light as required by Rule 22 in 33USC2022(c) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Accommodation/Occupational Safety
Issued 21 May 1993
Resolved
Secure the toilet to the deck prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Fire Fighting
Issued 21 May 1993
Resolved
Replace the fire hose to the portable fire pump as required by 46CFR181.10-5(a) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Provide five (5) adult personal flotation devices as required by 46CFR180.25-5(a) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Mark adult and children lifejacket stowage locations with the type and number of lifejackets as required by 46CFR180.25-15(b) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Provide six (6) current orange smoke flares as required by 46CFR180.35- 5(a)(1) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Accommodation/Occupational Safety
Issued 21 May 1993
Resolved
Post a "Discharge of Garbage Prohibited" placard in a conspicuous location as required by 33CFR151.59(b) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Repair grab line on ring life buoy as required by 46CFR160.050-4(c) prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 21 May 1993
Resolved
Replace the batteries and prove the operation of the EPIRB, waterlights, and flashlights prior to the compliance date.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Navigation
Issued 8 May 1986
Resolved
PROVIDE NEW BATTERIES FOR EPIRB.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Construction/Loadline
Issued 8 May 1986
Resolved
RENEW WASTED GASKET ON FORWARD HATCH.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Electrical
Issued 8 May 1986
Resolved
PROVIDE EMERGENCY FLASHLIGHT WITH LENS COVER.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Lifesaving
Issued 8 May 1986
Resolved
RENEW WASTED LIFELINE ON BUOYANT APPARATUS
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Navigation
Issued 8 May 1986
Resolved
PROVIDE LENS COVER FOR STERN LIGHT. REPLACE BURNED THROUGH LENS COVER ON ANCHOR LIGHT.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Documentation
Issued 8 May 1986
Resolved
MAKE LEGIBLE THE EMERGENCY CHECK-OFF LIST IN CABIN.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Lifesaving
Issued 8 May 1986
Resolved
REPAIR WATERLIGHT ON BUOYANT APPARATUS.
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Accommodation/Occupational Safety
Issued 8 May 1986
Resolved
CAP OFF VALVE OPPOSITE RESTROOM IN CABIN, PORT SIDE AFT.(JUST ABOVE DECK).
Condition: Unknown
Due 8 May 1986
Resolved 8 May 1986
Construction/Loadline
Issued 28 September 1984
Resolved
PRIOR TO REFLOATING THE VESSEL, EFFECT REPAIRS TO THE AREA OF THE HULL APPROX 4-5' AFT OF THE WATERLINE AT THE KEEL. NOTIFY THE USCG MARINE INSP OFFICE PRIOR TO COMMENCING REPAIRS, AND SCHEDULE VISITS BY A USCG INSPECTORDURING THE COMPLETION OF REPAIRS.
Condition: Unknown
Due 28 September 1984
Resolved 28 September 1984