Records from 2016 to 2026. Most recent: inspection, 21 May 2026.
Inspection history · 16
21 May 2026
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8377426
22 July 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8090930
29 May 2025
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087886
18 July 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873660
20 July 2023
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7740853
17 April 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7623015
12 August 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411380
3 May 2021
COI Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161250
15 April 2021
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150993
21 July 2020
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6904155
18 July 2019
Annual Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637842
25 April 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637750
13 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375214
29 June 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105367
20 April 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105909
5 May 2016
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829895
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2026
Resolved
Retroreflective tape on 3 lifejackets is unserviceable
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: Applied new retroreflective tape to life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 May 2026
Resolved
The lifejacket placard was for a different model than the type the vessel carried.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 May 2026
Resolution: The new donning placard was posted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 May 2026
Resolved
The step for the swim ladder on the transom had a damaged weld.
Action required: 705 - Other - as specified
Resolved 22 May 2026
Resolution: The weld has been repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 July 2025
Resolved
Each ring life buoy must be marked with Type II retroreflective material. Renew the worn retroreflective tape on the current life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 August 2025
Resolved 23 July 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 July 2023
Resolved
Each hatch exposed to the weather must be watertight. The inspection port for the emergency fuel shutoff was not provided with a gasket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 10 August 2023
Resolution: Inspection port for the emergency fuel shutoff was renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 20 July 2023
Resolved
Each hatch cover must— (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or to other devices to prevent its loss. The hatch for the steering compartment was not secured to the deck and had open screw holes preventing the hatch from being watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 10 August 2023
Resolution: Aft steering compartment hatch was secured to the deck and made watertight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 July 2023
Resolved
Through hull fittings and shutoff valves must be metallic. Protection from mechanical damage must be specifically considered and all protective covering or shields must be installed to the satisfaction of the cognizant OCMI.The installed fuel shutoff valve handle located at the tank was plastic and not provided any protection.
Old T 46 CFR 182.40-1
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 August 2023
Resolved 10 August 2023
Resolution: The fuel shutoff handle was replaced with a metallic handle.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 August 2022
Resolved
The installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection. Portable fire extinguisher BII in the pilot house is missing its bracket. Properly mount fire extinguisher and bracket.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 September 2022
Resolved 30 August 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 August 2022
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the 3 months before or after each anniversary date. Vessel has not completed an annual inspection within the 3 month time frame.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2022
Resolved 18 August 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2021
Resolved
Individual power pumps must have a light or other visual means at the control point to indicate operation. Auto bilge pump light not operational.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2021
Resolution: Witnessed operational bilge pump light.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 May 2021
Resolved
A vessel must carry a first aid kit approved under 160.041 or a kit with equivalent contents and instructions. First aid kit has expired asprin and burn cream.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2021
Resolution: Obtained unexpired asprin and burn cream.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 May 2021
Resolved
Each vessel on a lakes, bays, and sounds route must carry 3 handheld red flares and 3 orange smoke signals (can substitute red hand flares). Only 3 red handheld flares are onboard. Provide 3 additional.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 May 2021
Resolution: Vessel rep provided an additional 3 red handheld flares.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 May 2021
Resolved
Each vessel must be equipped with at least 2 operable portable battery lights. Provide 2 portable lights, one is onboard and one is missing.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 May 2021
Resolution: Vessel representative provided the required portable lights.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 May 2021
Resolved
A vessel must comply with requirements of 33 CFR parts 151, 155, and 156. Garbage placard is faded, renew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: They have obtained and posted a new garbage placard.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 May 2021
Resolved
Prior to departure on a voyage, the passenger count must be communicated verbally or in writing and available ashore at the vessel's normal berthing location or with a representative [name withheld] process on keeping passenger count onshore for all scenarios.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2021
Resolution: Vessel representative has a new process to keep track of passenger count. No matter the time of day, they text [name withheld] the passenger count upon getting underway.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 3 May 2021
Resolved
A vessel must comply with the applicable requirements for any radio installation issued by the FCC as set forth in 47 CFR 80. Master must have an FCC operators permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2021
Resolution: Provided copies of marine operator permits for masters who run the vessel.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 3 May 2021
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, and man overboard conditions. Modify emergency instructions specific for vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 May 2021
Resolution: A vessel specific set of emergency instructions has been posted at the operating station.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 July 2019
Resolved
Mast lights not IAW with nave rule for visability.
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 18 July 2019
Resolved 18 July 2019
Resolution: New lights installed on mast.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 18 July 2019
Resolved
Aft scupper non return device missing.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 18 July 2019
Resolved 18 July 2019
Resolution: New non return device installed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 July 2019
Resolved
First aid kit expired and missing supplies.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 July 2019
Resolved 18 July 2019
Resolution: New first aid kit placed in service.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 5 May 2016
Resolved
Portable fire extinguishers were not serviced, service fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2016
Resolved 12 May 2016
Communications › Radio Communications › VHF Radiotelephone
Issued 5 May 2016
Resolved
Set up VHF radio with MMSI number.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 19 May 2016
Resolution: Properly entered MMSI # in radio.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 5 May 2016
Resolved
Provide up to date publications.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 12 May 2016